HomeMy WebLinkAboutTechnical Information Report
STORMWATER DRAINAGE TECHNICAL REPORT
FOR
12955 Old Meridian Remodel
12955 Old Meridian St.
Carmel, IN 46032
Prepared by:
JPS Consulting Engineers
9365 Counselors Row Suite 116
Indianapolis, IN 46240
16 August 2019
Revised 12 December 2019
Certified by:
TABLE OF CONTENTS
I.Foreword
II.Site Location
III.Existing Conditions
IV.Storm Sewer Design
V.Site Run-Off
VI.Stormwater Detention
VII.Stormwater Quality
VIII.Summary
Appendix A Vicinity & Location Map
Appendix B Soil and Floodplain Map
Appendix C Storm Sewer Calculations
Appendix D Inlet Capacity Calculations
Appendix E Site Runoff Calculations
Appendix F BMP Sizing Calculations
STORMWATER DRAINAGE TECHNICAL REPORT
I. Foreword
The proposed project consists of a new 5,940 square foot single storyu retail/commercial building for
future build-out. The project is located south Main St on the east side of Old Meridian St.
Construction will take place on a currently developed lot and part of an existing strip mall. The northern
portion of the existing building and site improvements on the site will be demolished and the new
addition and parking will be reconstructed to fit the new addition. A new dumpster and loading berth will
also be constructed. Stormwater quantity will continue to be addressed by the existing dry detention
basin that exists to the south of the construction site. Stormwater quality will continue to be handled by
the existing dry detention basin which functions as a stormwater quality measure. An additional
structural BMP will be added to the project to treat the majority of the disturbed impervious area.
Bentley PondPack was used for all hydrologic modeling for the overall site project run-off. Hydraflow
Storm Sewers computer program was used to verify the capacity of the existing storm sewers. All input
and calculation reports are included in the various appendixes and discussed in more detail in the
following sections.
This report contains information on the stormwater management for the project including proposed
stormwater conveyance/pipe design, and stormwater quality for the project. The proposed stormwater
management is intended to meet the City of Carmel Stormwater Technical Standards Manual.
II. Site Location
The project is located 12955 Old Meridian St just south of Main Street. The project will demolish a
portion of the existing building and site improvements on site and construct a new building addition and
reconstruct the parking lot. The project site is bordered by Old Meridian St to the west, Carmel Middle
School to the east, an empty lot to the north and a strip mall to the south. Land use for the bordering
parcels is summarized below:
A site location and vicinity maps and a zoning map are included in Appendix A for reference.
III. Existing Conditions
The existing property is a currently developed property with a strip mall building and parking lot. Existing
drainage is generally split east and west. The lot generally surface drains to various inlets on the outskirts
of the property. The inlets on the east side of the site are installed right before the grade drops off and no
curb is installed. During periods of intense rains, run-off bypasses the inlet and drains onto adjacent
Direction Land Use Carmel Zoning
North Empty Lot UC
South BRU Carmel RE Commercial UC
West KG Main LLC UC
East Carmel Middle School R-1
properties and ruts out the existing grass. The storm inlets on the property all drain into an existing dry
detention basin and stormwater quality measure on the south side of the property.
Per the FEMA FIRM Map there are no special flood hazards present at this site. The existing soils on site
are Brookston silty clay loam, Br, and Miami silt loam, MmB2. Soil and the FEMA FIRM flood map for the
site are included in Appendix B.
IV. Storm Sewer Design
The storm sewer system for the new addition has been modeled for gravity flow with the Hydraflow Storm
Sewers software using the Rational Method and a 10-year frequency design storm. The only new storm
system is the roof drain from the new addition. Runoff coefficients were determined by land use and
adjusted to the next least pervious soil classification per Camel Stormwater Technical Standards
Manual. The majority of storm pipes are existing and have been remodeled to verify capacity. As is shown
in the following section, the run-off generated by this project will reduce the run-off generated so pipe
capacity should not be a problem. The system has been modeled past the next downstream pipe to
include all the pipes to the outlet into the existing detention system in the calculations. Existing storm
as-built information was updated per information that was on the original C0-4 but too small to read
when printed out. This information was transferred over to C0-5 and made larger so it was legible. In
addition, some field verification was conducted to verify pipe direction and inverts where necessary. All
existing inlets will be cleaned per notes on the plans, to remove the noted debris found in the structures.
Design storm values are per the Carmel Stormwater Technical Standards Manual. The storm sewer
calculations are included in Appendix C. In addition, inlets have been sized to calculate the gutter spread
to ensure that each existing inlet can accommodate the drainage watershed without being inundated.
Per the Carmel Stormwater Technical Standards, each inlet was analyzed at 50% clogged. All of the inlets
were able to handle the flows from their respective watersheds without flooding the roadway and allowing
a 10ft travel lane. Inlet capacity calculations are included in Appendix D.
V. Site Run-Off
As a result of this project, run-off leaving the site will be decreased. The limits of hard surface around the
building are reduced and the building area is also reduced. The existing soil infiltrating groups are already
at the lowest soil Hydrologic Group. Per the soils map, the existing soil hydrologic group values are as
follows:
Per the Carmel Stormwater Technical Standards Manual, the soil groups were changed to the next less
infiltrating group for the purpose of determining the post construction run-off. Since the existing soils
were in the D, hydrologic group, the soil properties were not changed to the D hydrologic group. The
characteristics of the proposed soil is summarized in the following table:
Soil Symbol Soil Name Soil Hydrologic
Group
Impervious Cn
Value
Pervious Cn Value
Br Brookston Silty
Clay Loam D 98 80
MmB2 Miami Silt Loam D 98 80
The pre and post construction run-off leaving the site and flowing into the drainage pond is summarized
below:
These values represent the run-off generated by the existing conditions and as a result of this project and
draining into the existing dry detention basin.
The Cn values were calculated using the following formula:
𝐶𝑁=
(𝐶𝑁𝑖𝑚𝑜𝑒𝑟𝑢𝑖𝑜𝑢𝑟× 𝑖𝑙𝑜𝑒𝑟𝑟𝑖𝑜𝑟𝑟𝑎𝑟𝑒𝑎)× (𝐶𝑁𝑜𝑒𝑟𝑢𝑖𝑜𝑢𝑟× 𝑜𝑒𝑟𝑟𝑖𝑜𝑟𝑟𝑎𝑟𝑒𝑎)
𝑇𝑜𝑟𝑎𝑙 𝐴𝑟𝑒𝑎
For the pre developed condition the values was calculated as follows:
𝐶𝑁= (98 × 0.63)+(80 × 0.06)
0.69 =96
For the post- developed condition the values were calculated as follows:
𝐶𝑁= (98 × 0.56)+(80 × 0.13)
0.69 =95
Run-off calculations are provided in Appendix E.
VI. Stormwater Detention
Stormwater Detention is currently being provided for the parcel by an existing dry detention basin and
stormwater quality measure. As was calculated in the previous section, this project is reducing the run-
off leaving the site as a result of the smaller building area and reduced hardscape in the parking lot.
Since the detention basin currently functions with the existing run-off rates, the reduced run-off rates will
be able to be detained by the existing detention basin without modifications. The existing detention basin
will continue to treat the run-off generated by this construction project and will continue to meet its
previously approved stormwater quantity flow rates. No modifications or changes to the dry detention
basin are proposed.
Soil Hydrologic Group Impervious Cn
Value
Pervious Cn Value
Group D 98 80
Pervious
Area
Impervious
Area
Cn Value 2 Year Run-
off
10 Year Run-
off
100 Year
Run-off
Pre-
Developed 0.06ac 0.63ac 96 2.23 cfs 3.30 cfs 5.67 cfs
Post-
Developed 0.13ac 0.56ac 95 2.14 cfs 3.22 cfs 5.61 cfs
VII. Stormwater Quality
Post construction stormwater quality treatment for the site will be provided by quality measures installed
with this project. Per the City of Carmel Stormwater Manual, two stormwater quality measures are
required for this project. The first BMP will continue to be the existing detention basin and modified
wetland. The existing detention basin has areas of extended wet conditions and substantial wetland type
plant growth. The basin currently acts as a stormwater quality measure and no modifications are
proposed to the basin to allow it to continue to function as a stormwater quality measure for this project
and the rest of the parcel.
The second required stormwater quality measure will be provided by a new structural BMP Aquaswirl Unit
AS-4. This unit will treat the disturbed and newly installed impervious area of the project before the run-
off enters the existing stormwater quality measure at the existing detention basin. The water quality flow
through structural BMP was calculated as outlined in Chapter 700 of the Carmel Stormwater Manual.
The water quality flow rate is summarized below:
The water quality curve number was determined using the Percent Impervious and Exhibit 701-1. Based
on the Indianapolis Approved BMP list and maximum treatment flows, an Aquaswirl AS-4 BMP will be
used. Refer to Appendix F for calculations on sizing the BMP. The Operation & Maintenance Manual for
this new BMP will be provided under separate cover.
VIII. Summary
The 12955 Old Meridian St Remodel project will include the demolition of a portion of the existing
building and parking lot and the construction of a new building addition, reworking of the parking lot,
and the reuse of the existing storm sewers and infrastructures to drain the new building and the
reconstructed parking lot. The project will generate lower run-off and collect water on-site and run it
through the existing detention basin. All drainage for the project is designed per the City of Carmel
Stormwater Technical Manual. The existing storm sewers have been checked to verify they will continue
to convey the 10-year design storm run-off rates. Run-off from the site will decrease in the post developed
condition. This decrease in run-off will continue to be detained by the existing detention basin on the
site. The existing detention basin serves as an existing BMP and an additional structural AS-4 6 BMP unit
will be provided to meet the Carmel requirements.
Total Treatment Area Percent Impervious Water Quality Curve
Number
Water Quality
Treatment Rate
0.48 ac 92% 99 0.60cfs
APPENDIX A: LOCATION & VICINITY MAPS
LOCATION MAP
PROJECT LOCATION
VICINITY MAP
ADDITION
W MAIN STREET
EDWARD ROSE DEVELOPMENT
ZONING: PUD
LAND USE: OFFICE BUILDING
ZONING:UC
LAND USE:
APARTMENTS
OLD MERIDIAN STREETZONING: UC
LAND USE:
COMMERCIAL
ZONING: R-1
LAND USE:
CARMEL MIDDLE
SCHOOL
APPENDIX B: SOIL AND FLOODPLAIN MAPS
USGS The National Map: Orthoimagery. Data refreshed April, 2019.
National Flood Hazard Layer FIRMette
0 500 1,000 1,500 2,000250Feet
Ü86°9'6.30"W 39°58'51.41"N 86°8'28.84"W 39°58'23.84"N
SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT
SPECIAL FLOODHAZARD AR EAS
Without Base Flood Elevation (BFE)Zone A, V, A99With BFE or Depth Zone AE, AO, AH, VE, AR
Regulator y Floodway
0.2% Annual Chance Flood Hazard, Areasof 1% annual chance flood with averagedepth less than one foot or with drainageareas of less than one square mile Zone X
Future Conditions 1% AnnualChance Flood Hazard Zone XArea with Reduced Flood Risk due toLevee. See Notes.Zone X
Area with Flood Risk due to Levee Zone D
NO SCREE N Area of Minimal Flood Hazard Zone X
Area of Undetermined Flood Hazard Zone D
Channel, Culver t, or Storm SewerLevee, Dike, or Floodwall
Cross Sections with 1% Annual Chance17.5 Water Surface ElevationCoastal Transect
Coastal Transect BaselineProfile BaselineHydrographic Feature
Base Flood Elevation Line (BFE)
Effective LOMRs
Limit of StudyJurisdiction Boundar y
Digital Data Available
No Digital Data Available
Unmapped
This map complies with FEMA's standards for the use of digital flood maps if it is not void as described below. The basemap shown complies with FEMA's basemap accuracy standards
The flood hazard information is derived directly from theauthoritative NFHL web ser vices provided by FEMA. This mapwas exported on 8/16/2019 at 11:32:38 AM and does notreflect changes or amendments subsequent to this date andtime. The NFHL and effective information may change orbecome superseded by new data over time.
This map image is void if the one or more of the following mapelements do not appear: basemap imagery, flood zone labels,legend, scale bar, map creation date, community identifiers,FIRM panel number, and FIRM effective date. Map images forunmapped and unmodernized areas cannot be used forregulatory purposes.
Legend
OTHER AREAS OFFLOOD HAZARD
OTHER AREAS
GENERALSTRUCTURES
OTHERFEATURES
MAP PANELS
8
1:6,000
B 20.2
The pin displayed on the map is an approximate point selected by the user and does not represent an authoritative proper ty location.
Soil Map—Hamilton County, Indiana
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
8/16/2019
Page 1 of 3442550044255104425520442553044255404425550442556044255704425580442559044256004425610442550044255104425520442553044255404425550442556044255704425580442559044256004425610572870572880572890572900572910572920572930572940572950
572870 572880 572890 572900 572910 572920 572930 572940 572950
39° 58' 39'' N 86° 8' 48'' W39° 58' 39'' N86° 8' 44'' W39° 58' 35'' N
86° 8' 48'' W39° 58' 35'' N
86° 8' 44'' WN
Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 16N WGS84
0 25 50 100 150
Feet
0 5 10 20 30
Meters
Map Scale: 1:567 if printed on A portrait (8.5" x 11") sheet.
Soil Map may not be valid at this scale.
MAP LEGEND MAP INFORMATION
Area of Interest (AOI)
Area of Interest (AOI)
Soils
Soil Map Unit Polygons
Soil Map Unit Lines
Soil Map Unit Points
Special Point Features
Blowout
Borrow Pit
Clay Spot
Closed Depression
Gravel Pit
Gravelly Spot
Landfill
Lava Flow
Marsh or swamp
Mine or Quarry
Miscellaneous Water
Perennial Water
Rock Outcrop
Saline Spot
Sandy Spot
Severely Eroded Spot
Sinkhole
Slide or Slip
Sodic Spot
Spoil Area
Stony Spot
Very Stony Spot
Wet Spot
Other
Special Line Features
Water Features
Streams and Canals
Transportation
Rails
Interstate Highways
US Routes
Major Roads
Local Roads
Background
Aerial Photography
The soil surveys that comprise your AOI were mapped at
1:15,800.
Warning: Soil Map may not be valid at this scale.
Enlargement of maps beyond the scale of mapping can cause
misunderstanding of the detail of mapping and accuracy of soil
line placement. The maps do not show the small areas of
contrasting soils that could have been shown at a more detailed
scale.
Please rely on the bar scale on each map sheet for map
measurements.
Source of Map: Natural Resources Conservation Service
Web Soil Survey URL:
Coordinate System: Web Mercator (EPSG:3857)
Maps from the Web Soil Survey are based on the Web Mercator
projection, which preserves direction and shape but distorts
distance and area. A projection that preserves area, such as the
Albers equal-area conic projection, should be used if more
accurate calculations of distance or area are required.
This product is generated from the USDA-NRCS certified data as
of the version date(s) listed below.
Soil Survey Area: Hamilton County, Indiana
Survey Area Data: Version 19, Sep 7, 2018
Soil map units are labeled (as space allows) for map scales
1:50,000 or larger.
Date(s) aerial images were photographed: Aug 1, 2018—Sep
30, 2018
The orthophoto or other base map on which the soil lines were
compiled and digitized probably differs from the background
imagery displayed on these maps. As a result, some minor
shifting of map unit boundaries may be evident.
Soil Map—Hamilton County, Indiana
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
8/16/2019
Page 2 of 3
Map Unit Legend
Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI
Br Brookston silty clay loam, 0 to
2 percent slopes
0.4 36.0%
MmB2 Miami silt loam, 2 to 6 percent
slopes, eroded
0.6 64.0%
Totals for Area of Interest 1.0 100.0%
Soil Map—Hamilton County, Indiana
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
8/16/2019
Page 3 of 3
APPENDIX C: STORM SEWER CALCULATIONS
PIVJPS Consulting Engineers - K:\Civil Projects\19JPSC26 Meridian Design Center\Drawings\BASIN.dwg August 17, 2019 - 2:57 PM Nvergatos
STORMINLETBASIN MAPNO SCALENBVNBVNBVSTMCONSTRUCTIONDOCUMENTS19 AUGUST 201919JPSC26EX. BASIN 1TOTAL AREA: 0.17acIMPERVIOUS: 0.15acPERVIOUS: 0.02acEX. BASIN 2TOTAL AREA: 0.17acIMPERVIOUS: 0.15acPERVIOUS: 0.02acROOFTOTAL AREA: 0.13acIMPERVIOUS: 0.13acEXISTING INLETTOTAL AREA: 0.25acIMPERVIOUS: 0.25ac
1
E
xistin
g Inl
e
t t
o
D
ete
ntio
n
2
EXISTING MH to EXISTING INLET3
EX BASIN 2 to EXISTING MH4
EX BASIN 1 to EX BASIN 25RO
OF to EX BA
S
I
N 2
Outfall
EXISTING INLET
EXISTING MH
EX BASIN 2
EX BASIN 1
ROOF
Hydraflow Storm Sewers Plan
Project File: 12955 Meridian Storm Calcs.stm Number of lines: 5 Date: 12-12-2019
Hydraflow Storm Sewers 2008 v12.01
Storm Sewer Summary Report Page 1
Line Line ID Flow Line Line Line Invert Invert Line HGL HGL Minor HGL Dns Junction
No. rate size shape length EL Dn EL Up slope down up loss Junct line Type
(cfs) (in) (ft) (ft) (ft) (%) (ft) (ft) (ft) (ft) No.
1 Existing Inlet to Detention 3.39 12 Cir 42 847.24 848.03 1.881 848.02 848.81 n/a 849.49 i End DropGrate
2 EXISTING MH to EXISTING INLET 2.55 12 Cir 39 848.53 848.97 1.128 849.49 849.65 n/a 850.13 i 1 Manhole
3 EX BASIN 2 to EXISTING MH 2.58 12 Cir 43 849.15 850.48 3.080 850.13 851.16 n/a 851.65 i 2 DropGrate
4 EX BASIN 1 to EX BASIN 2 0.97 12 Cir 95 850.68 852.40 1.811 851.65 852.82 n/a 853.00 i 3 DropGrate
5 ROOF to EX BASIN 2 0.82 10 Cir 67 851.53 852.20 1.000 851.88 852.60 n/a 852.80 i 3 Manhole
Project File: 12955 Meridian Storm Calcs.stm Number of lines: 5 Run Date: 12-12-2019
NOTES: Return period = 10 Yrs. ; i - Inlet control.
Hydraflow Storm Sewers 2008 v12.01
Storm Sewer Inventory Report Page 1
Line Alignment Flow Data Physical Data Line ID
No.
Dnstr Line Defl Junc Known Drng Runoff Inlet Invert Line Invert Line Line N J-loss Inlet/
line length angle type Q area coeff time El Dn slope El Up size shape value coeff Rim El
No. (ft) (deg) (cfs) (ac) (C) (min) (ft) (%) (ft) (in) (n) (K) (ft)
1 End 42 -136 DrGrt 0.00 0.15 0.90 5.0 847.24 1.88 848.03 12 Cir 0.012 1.50 851.95 Existing Inlet to
2 1 39 88 MH 0.00 0.00 0.00 0.0 848.53 1.13 848.97 12 Cir 0.012 0.70 855.06 EXISTING MH to EXI
3 2 43 -41 DrGrt 0.00 0.17 0.82 5.0 849.15 3.08 850.48 12 Cir 0.012 1.41 852.72 EX BASIN 2 to EXIS
4 3 95 -1 DrGrt 0.00 0.17 0.82 5.0 850.68 1.81 852.40 12 Cir 0.012 1.00 854.49 EX BASIN 1 to EX B
5 3 67 -68 MH 0.00 0.13 0.90 5.0 851.53 1.00 852.20 10 Cir 0.013 1.00 856.20 ROOF to EX BASIN 2
Project File: 12955 Meridian Storm Calcs.stm Number of lines: 5 Date: 12-12-2019
Hydraflow Storm Sewers 2008 v12.01
Structure Report Page 1
Struct Structure ID Junction Rim Line Out Line InStructure
No. Type Elev.
Size Shape Invert Size Shape InvertShape Length Width
(ft) (in) (ft) (in) (ft)(ft) (ft)
1 EXISTING INLET DropGrate 851.95 Cir 4.00 4.00 12 Cir 848.03 12 Cir 848.53
2 EXISTING MH Manhole 855.06 Cir 4.00 4.00 12 Cir 848.97 12 Cir 849.15
3 EX BASIN 2 DropGrate 852.72 Cir 4.00 4.00 12 Cir 850.48 12 Cir 850.68
10 Cir 851.53
4 EX BASIN 1 DropGrate 854.49 Cir 4.00 4.00 12 Cir 852.40
5 ROOF Manhole 856.20 Cir 4.00 4.00 10 Cir 852.20
Project File: 12955 Meridian Storm Calcs.stm Number of Structures: 5 Run Date: 12-12-2019
Hydraflow Storm Sewers 2008 v12.01
Storm Sewer Tabulation Page 1
Station Len Drng Area Rnoff Area x C Tc Rain Total Cap Vel Pipe Invert Elev HGL Elev Grnd / Rim Elev Line ID
coeff (I) flow full
Line To Incr Total Incr Total Inlet Syst Size Slope Dn Up Dn Up Dn Up
Line
(ft) (ac) (ac) (C) (min) (min) (in/hr) (cfs) (cfs) (ft/s) (in) (%) (ft) (ft) (ft) (ft) (ft) (ft)
1 End 42 0.15 0.62 0.90 0.14 0.53 5.0 6.7 6.4 3.39 5.29 5.15 12 1.88 847.24 848.03 848.02 848.81 847.64 851.95 Existing Inlet to De
2 1 39 0.00 0.47 0.00 0.00 0.40 0.0 6.5 6.4 2.55 4.10 3.90 12 1.13 848.53 848.97 849.49 849.65 851.95 855.06 EXISTING MH to
3 2 43 0.17 0.47 0.82 0.14 0.40 5.0 6.3 6.5 2.58 6.77 3.91 12 3.08 849.15 850.48 850.13 851.16 855.06 852.72 EX BASIN 2 to EXI
4 3 95 0.17 0.17 0.82 0.14 0.14 5.0 5.0 7.0 0.97 5.19 2.19 12 1.81 850.68 852.40 851.65 852.82 852.72 854.49 EX BASIN 1 to EX
5 3 67 0.13 0.13 0.90 0.12 0.12 5.0 5.0 7.0 0.82 2.19 3.43 10 1.00 851.53 852.20 851.88 852.60 852.72 856.20 ROOF to EX BASI
Project File: 12955 Meridian Storm Calcs.stm Number of lines: 5 Run Date: 12-12-2019
NOTES: Intensity = 57.92 / (Inlet time + 9.10) ^ 0.80; Return period = 10 Yrs. ; c = cir e = ellip b = box
Hydraflow Storm Sewers 2008 v12.01
Inlet Report Page 1
Line Inlet ID Q = Q Q Q Junc Curb Inlet Grate Inlet Gutter Inlet Byp
No CIA carry capt byp type line
Ht L area L W So W Sw Sx n Depth Spread Depth Spread Depr No
(cfs) (cfs) (cfs) (cfs) (in) (ft) (sqft) (ft) (ft) (ft/ft) (ft) (ft/ft) (ft/ft) (ft) (ft) (ft) (ft) (in)
1 EXISTING INLET 0.94 0.00 0.94 0.00 DrGrt 4.0 4.00 2.00 2.00 2.00 Sag 2.00 0.020 0.020 0.013 0.12 13.54 0.12 13.54 0.0 Off
2 EXISTING MH 0.00 0.00 0.00 0.00 MH 4.0 4.00 2.00 2.00 2.00 Sag 2.00 0.020 0.020 0.013 0.00 0.00 0.00 0.00 0.0 1
3 EX BASIN 2 0.97 0.82 1.79 0.00 DrGrt 4.0 4.00 2.00 2.00 2.00 Sag 2.00 0.020 0.020 0.013 0.18 19.71 0.18 19.71 0.0 2
4 EX BASIN 1 0.97 0.00 0.97 0.00 DrGrt 4.0 4.00 2.00 2.00 2.00 Sag 2.00 0.020 0.020 0.013 0.12 13.79 0.12 13.79 0.0 3
5 ROOF 0.82 0.00 0.00 0.82 MH 4.0 4.00 2.00 2.00 2.00 Sag 2.00 0.050 0.020 0.013 0.00 0.00 0.00 0.00 0.0 3
Project File: 12955 Meridian Storm Calcs.stm Number of lines: 5 Run Date: 12-12-2019
NOTES: Inlet N-Values = 0.01 ;Intensity = 57.92 / (Inlet time + 9.10) ^ 0.80; Return period = 10 Yrs. ; * Indicates Known Q added. All curb inlets are Horiz throat.
Hydraflow Storm Sewers 2008 v12.01
Hydraulic Grade Line Computations Page 1
Line Size Q Downstream Len Upstream Check JL Minor
coeff loss
Invert HGL Depth Area Vel Vel EGL Sf Invert HGL Depth Area Vel Vel EGL Sf Ave Enrgy
elev elev head elev elev elev head elev Sf loss
(in) (cfs) (ft) (ft) (ft) (sqft) (ft/s) (ft) (ft) (%) (ft) (ft) (ft) (ft) (sqft) (ft/s) (ft) (ft) (%) (%) (ft) (K) (ft)
1 12 3.39 847.24 848.02 0.78 0.66 5.15 0.41 848.43 n/a 42 848.03 848.81 0.78** 0.66 5.15 0.41 849.22i n/a n/a n/a 1.50 n/a
2 12 2.55 848.53 849.49 0.96 0.78 3.29 0.17 849.66 n/a 39 848.97 849.65 j 0.68** 0.57 4.50 0.32 849.96i n/a n/a n/a 0.70 n/a
3 12 2.58 849.15 850.13 0.98 0.78 3.30 0.17 850.30 n/a 43 850.48 851.16 j 0.68** 0.57 4.53 0.32 851.48i n/a n/a n/a 1.41 n/a
4 12 0.97 850.68 851.65 0.97 0.78 1.25 0.02 851.67 n/a 95 852.40 852.82 j 0.42** 0.31 3.12 0.15 852.97i n/a n/a n/a 1.00 n/a
5 10 0.82 851.53 851.88 0.35* 0.22 3.72 0.22 852.10 n/a 67 852.20 852.60 0.40** 0.26 3.14 0.15 852.75i n/a n/a n/a 1.00 n/a
Project File: 12955 Meridian Storm Calcs.stm Number of lines: 5 Run Date: 12-12-2019
Notes: * Normal depth assumed.; ** Critical depth.; j-Line contains hyd. jump. ; c = cir e = ellip b = box
Hydraflow Storm Sewers 2008 v12.01
MyReport Page 1
Line Inlet Drng Flow Vel Capac Runoff Line Line Vel Invert Invert Gnd/Rim Cover Gnd/Rim Cover n-val
No. ID Area Rate Dn Full Coeff Size Length Up Up Dn El Up Up El Dn Dn Pipe
(ac) (cfs) (ft/s) (cfs) (C) (in) (ft) (ft/s) (ft) (ft) (ft) (ft) (ft) (ft)
1 EXISTING INLET 0.15 3.39 5.15 5.29 0.90 12 42 5.15 848.03 847.24 851.95 2.92 847.64 -0.60 0.012
2 EXISTING MH 0.00 2.55 3.29 4.10 0.00 12 39 4.50 848.97 848.53 855.06 5.09 851.95 2.42 0.012
3 EX BASIN 2 0.17 2.58 3.30 6.77 0.82 12 43 4.53 850.48 849.15 852.72 1.24 855.06 4.91 0.012
4 EX BASIN 1 0.17 0.97 1.25 5.19 0.82 12 95 3.12 852.40 850.68 854.49 1.09 852.72 1.04 0.012
5 ROOF 0.13 0.82 3.72 2.19 0.90 10 67 3.14 852.20 851.53 856.20 3.17 852.72 0.36 0.013
Project File: 12955 Meridian Storm Calcs.stm Number of lines: 5 Date: 12-12-2019
NOTES: i Inlet control; ** Critical depth
Hydraflow Storm Sewers 2008
APPENDIX D: INLET CAPACITY CALCULATIONS
Project Name: Structure:
Job Number: 19JPSC26 Date:
Design Depth of Water Over Grate (ft.): 0.50 % Plugged: 50%0.50
Casting:3405 Perimeter (ft): 7.90 Open Area (sf): 1.50
Solve For Qi Allowable:
Note: Formulas Obtained From Neenah Foundry Company Inlet Capacity Worksheets
Transitional Flow Eqn: Qi = ((QOrifice + QWeir)/2) x .80 = ((2.6+4.6)/2) x .80 = 2.6 cfs
Orifice Flow Eqn:Weir Flow Eqn:
Qi =[( 0.6)(A)(Pp)] x [(2)(g)(h)]1/2 Qi =3.3(P)(Pp)(dw)1.5
Where:Where:
Qi = Inlet Capacity (CFS)Qi = Inlet Capacity (CFS)
A = Fee open area of grate (sf)P = Perimeter of Grate Opening (ft)
g = 32.2 (ft per sec/sec)dw = Depth Of Water Above Grate
h = Head (ft) (Water Depth)Pp = Percent Plugged
Pp = Percent Plugged
Qi = 2.6 cfs allowable Qi = Use Orifice Flow Equation 2.6
2.6 4.60
Allowable Inlet Flow = 2.6 cfs
Solve For Q Actual:
Rational Formula:Q10 = C x I x A
Where:
Q10 = Flow from 10 year storm event
C = Runoff Coefficient (unitless)
I = Rainfall intensity (in/hr)
A = Watershed area (ac)
C = 0.82
I = 6.12 in/hr T.C. =5.0 min
A = 0.17 ac 0.9
Actual Inlet Flow = 0.9 cfs
Q Comparison Result:Casting Is Sufficient
Note: At this depth, transitional flow is anticipated. The allowable inlet flow shown is 80% of
the average of the weir and orifice flow due to vortex action. This adjustment value obtained
from Neenah Foundry technical division.
Discharge vs. Depth on Grate Calculation
12955 Old Meridian Remodel EX BASIN 1
For Inlets In Sag Conditions
16-Aug-19
Project Name: Structure:
Job Number: 19JPSC26 Date:
Design Depth of Water Over Grate (ft.): 0.50 % Plugged: 50%0.50
Casting:3405 Perimeter (ft): 7.90 Open Area (sf): 1.50
Solve For Qi Allowable:
Note: Formulas Obtained From Neenah Foundry Company Inlet Capacity Worksheets
Transitional Flow Eqn: Qi = ((QOrifice + QWeir)/2) x .80 = ((2.6+4.6)/2) x .80 = 2.6 cfs
Orifice Flow Eqn:Weir Flow Eqn:
Qi =[( 0.6)(A)(Pp)] x [(2)(g)(h)]1/2 Qi =3.3(P)(Pp)(dw)1.5
Where:Where:
Qi = Inlet Capacity (CFS)Qi = Inlet Capacity (CFS)
A = Fee open area of grate (sf)P = Perimeter of Grate Opening (ft)
g = 32.2 (ft per sec/sec)dw = Depth Of Water Above Grate
h = Head (ft) (Water Depth)Pp = Percent Plugged
Pp = Percent Plugged
Qi = 2.6 cfs allowable Qi = Use Orifice Flow Equation 2.6
2.6 4.60
Allowable Inlet Flow = 2.6 cfs
Solve For Q Actual:
Rational Formula:Q10 = C x I x A
Where:
Q10 = Flow from 10 year storm event
C = Runoff Coefficient (unitless)
I = Rainfall intensity (in/hr)
A = Watershed area (ac)
C = 0.82
I = 6.12 in/hr T.C. =5.0 min
A = 0.17 ac 0.9
Actual Inlet Flow = 0.9 cfs
Q Comparison Result:Casting Is Sufficient
Note: At this depth, transitional flow is anticipated. The allowable inlet flow shown is 80% of
the average of the weir and orifice flow due to vortex action. This adjustment value obtained
from Neenah Foundry technical division.
Discharge vs. Depth on Grate Calculation
For Inlets In Sag Conditions
12955 Old Meridian Remodel EX BASIN 2
16-Aug-19
APPENDIX E: SITE RUNOFF CALCULATIONS
PREDEVELOPEDBASIN MAPNO SCALENBVNBVNBVPRECONSTRUCTIONDOCUMENTS19 AUGUST 201919JPSC26TOTAL AREA: 0.69acIMPERVIOUS: 0.63acPERVIOUS: 0.06ac
NEW BUILDING ADDITION5,940 SQ FTFINISHED FLOOR ELEVATION: 856.20TJPS Consulting Engineers - K:\Civil Projects\19JPSC26 Meridian Design Center\Drawings\BASIN.dwg August 17, 2019 - 2:29 PM Nvergatos
POSTDEVELOPEDBASIN MAPNO SCALENBVNBVNBVPOSTCONSTRUCTIONDOCUMENTS19 AUGUST 201919JPSC26TOTAL AREA: 0.69acIMPERVIOUS: 0.56acPERVIOUS: 0.13ac
Table of Contents
22Unit Hydrograph Summary, 100 years
22Unit Hydrograph Summary, 100 years
18Unit Hydrograph Summary, 10 years
18Unit Hydrograph Summary, 10 years
14Unit Hydrograph Summary, 2 years
14Unit Hydrograph Summary, 2 years
CM-1
10Time-Depth Curve, 2 years
10Time-Depth Curve, 2 years
6Time-Depth Curve, 100 years
6Time-Depth Curve, 100 years
2Time-Depth Curve, 10 years
2Time-Depth Curve, 10 years
Time-Depth - 1
1Master Network Summary
12955 Old Meridian Remodel
Subsection: Master Network Summary
Catchments Summary
Peak Flow
(ft³/s)
Time to Peak
(hours)
Hydrograph
Volume
(ac-ft)
Return
Event
(years)
ScenarioLabel
2.2311.9000.1302Pre-Development 2
year
CM-1
2.1411.9000.1222Post-Development 2
year
CM-1
3.2211.9000.18710Post-Development 10
year
CM-1
3.3011.9000.19610Pre-Development 10
year
CM-1
5.6711.9000.347100Pre-Development 100
year
CM-1
5.6111.9000.337100Post-Development
100 year
CM-1
Node Summary
Peak Flow
(ft³/s)
Time to Peak
(hours)
Hydrograph
Volume
(ac-ft)
Return
Event
(years)
ScenarioLabel
2.2311.9000.1302Pre-Development 2
year
O-1
2.1411.9000.1222Post-Development 2
year
O-1
3.2211.9000.18710Post-Development 10
year
O-1
3.3011.9000.19610Pre-Development 10
year
O-1
5.6711.9000.347100Pre-Development 100
year
O-1
5.6111.9000.337100Post-Development
100 year
O-1
Page 1 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 10 year stormLabel: Time-Depth - 1
Return Event: 10 yearsSubsection: Time-Depth Curve
Time-Depth Curve: 10 year storm
10 year stormLabel
hours0.000Start Time
hours0.100Increment
hours24.000End Time
years10Return Event
CUMULATIVE RAINFALL (in)
Output Time Increment = 0.100 hours
Time on left represents time for first value in each row.
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Time
(hours)
0.00.00.00.00.00.000
0.00.00.00.00.00.500
0.10.10.00.00.01.000
0.10.10.10.10.11.500
0.10.10.10.10.12.000
0.10.10.10.10.12.500
0.20.10.10.10.13.000
0.20.20.20.20.23.500
0.20.20.20.20.24.000
0.20.20.20.20.24.500
0.30.30.30.20.25.000
0.30.30.30.30.35.500
0.30.30.30.30.36.000
0.40.40.40.30.36.500
0.40.40.40.40.47.000
0.50.40.40.40.47.500
0.50.50.50.50.58.000
0.60.50.50.50.58.500
0.60.60.60.60.69.000
0.70.70.70.60.69.500
0.80.70.70.70.710.000
0.90.80.80.80.810.500
1.01.01.00.90.911.000
2.21.61.41.21.111.500
2.82.72.72.62.512.000
2.92.92.92.82.812.500
3.03.03.03.03.013.000
3.13.13.13.13.113.500
3.23.23.23.23.114.000
3.33.23.23.23.214.500
3.33.33.33.33.315.000
3.43.43.33.33.315.500
3.43.43.43.43.416.000
3.43.43.43.43.416.500
Page 2 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 10 year stormLabel: Time-Depth - 1
Return Event: 10 yearsSubsection: Time-Depth Curve
CUMULATIVE RAINFALL (in)
Output Time Increment = 0.100 hours
Time on left represents time for first value in each row.
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Time
(hours)
3.53.53.53.53.517.000
3.53.53.53.53.517.500
3.63.53.53.53.518.000
3.63.63.63.63.618.500
3.63.63.63.63.619.000
3.63.63.63.63.619.500
3.73.73.73.73.620.000
3.73.73.73.73.720.500
3.73.73.73.73.721.000
3.73.73.73.73.721.500
3.83.83.83.73.722.000
3.83.83.83.83.822.500
3.83.83.83.83.823.000
3.83.83.83.83.823.500
(N/A)(N/A)(N/A)(N/A)3.824.000
Page 3 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 10 year stormLabel: Time-Depth - 1
Return Event: 10 yearsSubsection: Time-Depth Curve
Time-Depth Curve: 10 year storm
10 year stormLabel
hours0.000Start Time
hours0.100Increment
hours24.000End Time
years10Return Event
CUMULATIVE RAINFALL (in)
Output Time Increment = 0.100 hours
Time on left represents time for first value in each row.
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Time
(hours)
0.00.00.00.00.00.000
0.00.00.00.00.00.500
0.10.10.00.00.01.000
0.10.10.10.10.11.500
0.10.10.10.10.12.000
0.10.10.10.10.12.500
0.20.10.10.10.13.000
0.20.20.20.20.23.500
0.20.20.20.20.24.000
0.20.20.20.20.24.500
0.30.30.30.20.25.000
0.30.30.30.30.35.500
0.30.30.30.30.36.000
0.40.40.40.30.36.500
0.40.40.40.40.47.000
0.50.40.40.40.47.500
0.50.50.50.50.58.000
0.60.50.50.50.58.500
0.60.60.60.60.69.000
0.70.70.70.60.69.500
0.80.70.70.70.710.000
0.90.80.80.80.810.500
1.01.01.00.90.911.000
2.21.61.41.21.111.500
2.82.72.72.62.512.000
2.92.92.92.82.812.500
3.03.03.03.03.013.000
3.13.13.13.13.113.500
3.23.23.23.23.114.000
3.33.23.23.23.214.500
3.33.33.33.33.315.000
3.43.43.33.33.315.500
3.43.43.43.43.416.000
3.43.43.43.43.416.500
Page 4 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 10 year stormLabel: Time-Depth - 1
Return Event: 10 yearsSubsection: Time-Depth Curve
CUMULATIVE RAINFALL (in)
Output Time Increment = 0.100 hours
Time on left represents time for first value in each row.
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Time
(hours)
3.53.53.53.53.517.000
3.53.53.53.53.517.500
3.63.53.53.53.518.000
3.63.63.63.63.618.500
3.63.63.63.63.619.000
3.63.63.63.63.619.500
3.73.73.73.73.620.000
3.73.73.73.73.720.500
3.73.73.73.73.721.000
3.73.73.73.73.721.500
3.83.83.83.73.722.000
3.83.83.83.83.822.500
3.83.83.83.83.823.000
3.83.83.83.83.823.500
(N/A)(N/A)(N/A)(N/A)3.824.000
Page 5 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 100 year stormLabel: Time-Depth - 1
Return Event: 100 yearsSubsection: Time-Depth Curve
Time-Depth Curve: 100 year storm
100 year stormLabel
hours0.000Start Time
hours0.100Increment
hours24.000End Time
years100Return Event
CUMULATIVE RAINFALL (in)
Output Time Increment = 0.100 hours
Time on left represents time for first value in each row.
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Time
(hours)
0.00.00.00.00.00.000
0.10.10.00.00.00.500
0.10.10.10.10.11.000
0.10.10.10.10.11.500
0.20.20.20.10.12.000
0.20.20.20.20.22.500
0.30.20.20.20.23.000
0.30.30.30.30.33.500
0.30.30.30.30.34.000
0.40.40.40.40.44.500
0.40.40.40.40.45.000
0.50.50.50.50.55.500
0.60.60.50.50.56.000
0.60.60.60.60.66.500
0.70.70.70.70.67.000
0.80.70.70.70.77.500
0.80.80.80.80.88.000
0.90.90.90.90.98.500
1.01.01.01.00.99.000
1.11.11.11.11.19.500
1.31.31.21.21.210.000
1.51.41.41.41.310.500
1.81.71.61.61.511.000
3.72.82.32.01.811.500
4.74.64.54.44.312.000
4.94.94.94.84.712.500
5.15.15.15.05.013.000
5.35.25.25.25.213.500
5.45.45.35.35.314.000
5.55.55.55.45.414.500
5.65.65.65.55.515.000
5.75.75.65.65.615.500
5.75.75.75.75.716.000
5.85.85.85.85.816.500
Page 6 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 100 year stormLabel: Time-Depth - 1
Return Event: 100 yearsSubsection: Time-Depth Curve
CUMULATIVE RAINFALL (in)
Output Time Increment = 0.100 hours
Time on left represents time for first value in each row.
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Time
(hours)
5.95.95.95.85.817.000
5.95.95.95.95.917.500
6.06.06.06.05.918.000
6.06.06.06.06.018.500
6.16.16.16.16.119.000
6.16.16.16.16.119.500
6.26.26.26.26.120.000
6.26.26.26.26.220.500
6.36.36.26.26.221.000
6.36.36.36.36.321.500
6.36.36.36.36.322.000
6.46.46.46.46.322.500
6.46.46.46.46.423.000
6.56.46.46.46.423.500
(N/A)(N/A)(N/A)(N/A)6.524.000
Page 7 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 100 year stormLabel: Time-Depth - 1
Return Event: 100 yearsSubsection: Time-Depth Curve
Time-Depth Curve: 100 year storm
100 year stormLabel
hours0.000Start Time
hours0.100Increment
hours24.000End Time
years100Return Event
CUMULATIVE RAINFALL (in)
Output Time Increment = 0.100 hours
Time on left represents time for first value in each row.
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Time
(hours)
0.00.00.00.00.00.000
0.10.10.00.00.00.500
0.10.10.10.10.11.000
0.10.10.10.10.11.500
0.20.20.20.10.12.000
0.20.20.20.20.22.500
0.30.20.20.20.23.000
0.30.30.30.30.33.500
0.30.30.30.30.34.000
0.40.40.40.40.44.500
0.40.40.40.40.45.000
0.50.50.50.50.55.500
0.60.60.50.50.56.000
0.60.60.60.60.66.500
0.70.70.70.70.67.000
0.80.70.70.70.77.500
0.80.80.80.80.88.000
0.90.90.90.90.98.500
1.01.01.01.00.99.000
1.11.11.11.11.19.500
1.31.31.21.21.210.000
1.51.41.41.41.310.500
1.81.71.61.61.511.000
3.72.82.32.01.811.500
4.74.64.54.44.312.000
4.94.94.94.84.712.500
5.15.15.15.05.013.000
5.35.25.25.25.213.500
5.45.45.35.35.314.000
5.55.55.55.45.414.500
5.65.65.65.55.515.000
5.75.75.65.65.615.500
5.75.75.75.75.716.000
5.85.85.85.85.816.500
Page 8 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 100 year stormLabel: Time-Depth - 1
Return Event: 100 yearsSubsection: Time-Depth Curve
CUMULATIVE RAINFALL (in)
Output Time Increment = 0.100 hours
Time on left represents time for first value in each row.
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Time
(hours)
5.95.95.95.85.817.000
5.95.95.95.95.917.500
6.06.06.06.05.918.000
6.06.06.06.06.018.500
6.16.16.16.16.119.000
6.16.16.16.16.119.500
6.26.26.26.26.120.000
6.26.26.26.26.220.500
6.36.36.26.26.221.000
6.36.36.36.36.321.500
6.36.36.36.36.322.000
6.46.46.46.46.322.500
6.46.46.46.46.423.000
6.56.46.46.46.423.500
(N/A)(N/A)(N/A)(N/A)6.524.000
Page 9 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 2 year stormLabel: Time-Depth - 1
Return Event: 2 yearsSubsection: Time-Depth Curve
Time-Depth Curve: 2 year storm
2 year stormLabel
hours0.000Start Time
hours0.100Increment
hours24.000End Time
years2Return Event
CUMULATIVE RAINFALL (in)
Output Time Increment = 0.100 hours
Time on left represents time for first value in each row.
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Time
(hours)
0.00.00.00.00.00.000
0.00.00.00.00.00.500
0.00.00.00.00.01.000
0.10.10.00.00.01.500
0.10.10.10.10.12.000
0.10.10.10.10.12.500
0.10.10.10.10.13.000
0.10.10.10.10.13.500
0.10.10.10.10.14.000
0.20.20.20.20.14.500
0.20.20.20.20.25.000
0.20.20.20.20.25.500
0.20.20.20.20.26.000
0.30.30.20.20.26.500
0.30.30.30.30.37.000
0.30.30.30.30.37.500
0.30.30.30.30.38.000
0.40.40.40.40.48.500
0.40.40.40.40.49.000
0.50.50.50.40.49.500
0.50.50.50.50.510.000
0.60.60.60.60.510.500
0.70.70.70.60.611.000
1.51.10.90.80.811.500
1.91.91.91.81.812.000
2.02.02.02.02.012.500
2.12.12.12.12.113.000
2.22.22.12.12.113.500
2.22.22.22.22.214.000
2.32.32.22.22.214.500
2.32.32.32.32.315.000
2.32.32.32.32.315.500
2.42.42.42.32.316.000
2.42.42.42.42.416.500
Page 10 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 2 year stormLabel: Time-Depth - 1
Return Event: 2 yearsSubsection: Time-Depth Curve
CUMULATIVE RAINFALL (in)
Output Time Increment = 0.100 hours
Time on left represents time for first value in each row.
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Time
(hours)
2.42.42.42.42.417.000
2.42.42.42.42.417.500
2.52.52.52.52.418.000
2.52.52.52.52.518.500
2.52.52.52.52.519.000
2.52.52.52.52.519.500
2.52.52.52.52.520.000
2.62.62.62.62.520.500
2.62.62.62.62.621.000
2.62.62.62.62.621.500
2.62.62.62.62.622.000
2.62.62.62.62.622.500
2.62.62.62.62.623.000
2.72.72.72.62.623.500
(N/A)(N/A)(N/A)(N/A)2.724.000
Page 11 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 2 year stormLabel: Time-Depth - 1
Return Event: 2 yearsSubsection: Time-Depth Curve
Time-Depth Curve: 2 year storm
2 year stormLabel
hours0.000Start Time
hours0.100Increment
hours24.000End Time
years2Return Event
CUMULATIVE RAINFALL (in)
Output Time Increment = 0.100 hours
Time on left represents time for first value in each row.
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Time
(hours)
0.00.00.00.00.00.000
0.00.00.00.00.00.500
0.00.00.00.00.01.000
0.10.10.00.00.01.500
0.10.10.10.10.12.000
0.10.10.10.10.12.500
0.10.10.10.10.13.000
0.10.10.10.10.13.500
0.10.10.10.10.14.000
0.20.20.20.20.14.500
0.20.20.20.20.25.000
0.20.20.20.20.25.500
0.20.20.20.20.26.000
0.30.30.20.20.26.500
0.30.30.30.30.37.000
0.30.30.30.30.37.500
0.30.30.30.30.38.000
0.40.40.40.40.48.500
0.40.40.40.40.49.000
0.50.50.50.40.49.500
0.50.50.50.50.510.000
0.60.60.60.60.510.500
0.70.70.70.60.611.000
1.51.10.90.80.811.500
1.91.91.91.81.812.000
2.02.02.02.02.012.500
2.12.12.12.12.113.000
2.22.22.12.12.113.500
2.22.22.22.22.214.000
2.32.32.22.22.214.500
2.32.32.32.32.315.000
2.32.32.32.32.315.500
2.42.42.42.32.316.000
2.42.42.42.42.416.500
Page 12 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 2 year stormLabel: Time-Depth - 1
Return Event: 2 yearsSubsection: Time-Depth Curve
CUMULATIVE RAINFALL (in)
Output Time Increment = 0.100 hours
Time on left represents time for first value in each row.
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Time
(hours)
2.42.42.42.42.417.000
2.42.42.42.42.417.500
2.52.52.52.52.418.000
2.52.52.52.52.518.500
2.52.52.52.52.519.000
2.52.52.52.52.519.500
2.52.52.52.52.520.000
2.62.62.62.62.520.500
2.62.62.62.62.621.000
2.62.62.62.62.621.500
2.62.62.62.62.622.000
2.62.62.62.62.622.500
2.62.62.62.62.623.000
2.72.72.72.62.623.500
(N/A)(N/A)(N/A)(N/A)2.724.000
Page 13 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 2 year stormLabel: CM-1
Return Event: 2 yearsSubsection: Unit Hydrograph Summary
2 year stormStorm Event
years2Return Event
hours24.000Duration
in2.7Depth
hours0.083Time of Concentration
(Composite)
acres0.690Area (User Defined)
hours0.011Computational Time
Increment
hours11.922Time to Peak (Computed)
ft³/s2.19Flow (Peak, Computed)
hours0.050Output Increment
hours11.900Time to Flow (Peak
Interpolated Output)
ft³/s2.14Flow (Peak Interpolated
Output)
Drainage Area
95.000SCS CN (Composite)
acres0.690Area (User Defined)
in0.5Maximum Retention
(Pervious)
in0.1Maximum Retention
(Pervious, 20 percent)
Cumulative Runoff
in2.1Cumulative Runoff Depth
(Pervious)
ac-ft0.122Runoff Volume (Pervious)
Hydrograph Volume (Area under Hydrograph curve)
ac-ft0.122Volume
SCS Unit Hydrograph Parameters
hours0.083Time of Concentration
(Composite)
hours0.011Computational Time
Increment
483.432Unit Hydrograph Shape
Factor
0.749K Factor
1.670Receding/Rising, Tr/Tp
Page 14 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 2 year stormLabel: CM-1
Return Event: 2 yearsSubsection: Unit Hydrograph Summary
SCS Unit Hydrograph Parameters
ft³/s9.38Unit peak, qp
hours0.056Unit peak time, Tp
hours0.222Unit receding limb, Tr
hours0.278Total unit time, Tb
Page 15 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 2 year stormLabel: CM-1
Return Event: 2 yearsSubsection: Unit Hydrograph Summary
2 year stormStorm Event
years2Return Event
hours24.000Duration
in2.7Depth
hours0.083Time of Concentration
(Composite)
acres0.690Area (User Defined)
hours0.011Computational Time
Increment
hours11.922Time to Peak (Computed)
ft³/s2.28Flow (Peak, Computed)
hours0.050Output Increment
hours11.900Time to Flow (Peak
Interpolated Output)
ft³/s2.23Flow (Peak Interpolated
Output)
Drainage Area
96.435SCS CN (Composite)
acres0.690Area (User Defined)
in0.4Maximum Retention
(Pervious)
in0.1Maximum Retention
(Pervious, 20 percent)
Cumulative Runoff
in2.3Cumulative Runoff Depth
(Pervious)
ac-ft0.130Runoff Volume (Pervious)
Hydrograph Volume (Area under Hydrograph curve)
ac-ft0.130Volume
SCS Unit Hydrograph Parameters
hours0.083Time of Concentration
(Composite)
hours0.011Computational Time
Increment
483.432Unit Hydrograph Shape
Factor
0.749K Factor
1.670Receding/Rising, Tr/Tp
Page 16 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 2 year stormLabel: CM-1
Return Event: 2 yearsSubsection: Unit Hydrograph Summary
SCS Unit Hydrograph Parameters
ft³/s9.38Unit peak, qp
hours0.056Unit peak time, Tp
hours0.222Unit receding limb, Tr
hours0.278Total unit time, Tb
Page 17 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 10 year stormLabel: CM-1
Return Event: 10 yearsSubsection: Unit Hydrograph Summary
10 year stormStorm Event
years10Return Event
hours24.000Duration
in3.8Depth
hours0.083Time of Concentration
(Composite)
acres0.690Area (User Defined)
hours0.011Computational Time
Increment
hours11.922Time to Peak (Computed)
ft³/s3.28Flow (Peak, Computed)
hours0.050Output Increment
hours11.900Time to Flow (Peak
Interpolated Output)
ft³/s3.22Flow (Peak Interpolated
Output)
Drainage Area
95.000SCS CN (Composite)
acres0.690Area (User Defined)
in0.5Maximum Retention
(Pervious)
in0.1Maximum Retention
(Pervious, 20 percent)
Cumulative Runoff
in3.3Cumulative Runoff Depth
(Pervious)
ac-ft0.188Runoff Volume (Pervious)
Hydrograph Volume (Area under Hydrograph curve)
ac-ft0.187Volume
SCS Unit Hydrograph Parameters
hours0.083Time of Concentration
(Composite)
hours0.011Computational Time
Increment
483.432Unit Hydrograph Shape
Factor
0.749K Factor
1.670Receding/Rising, Tr/Tp
Page 18 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 10 year stormLabel: CM-1
Return Event: 10 yearsSubsection: Unit Hydrograph Summary
SCS Unit Hydrograph Parameters
ft³/s9.38Unit peak, qp
hours0.056Unit peak time, Tp
hours0.222Unit receding limb, Tr
hours0.278Total unit time, Tb
Page 19 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 10 year stormLabel: CM-1
Return Event: 10 yearsSubsection: Unit Hydrograph Summary
10 year stormStorm Event
years10Return Event
hours24.000Duration
in3.8Depth
hours0.083Time of Concentration
(Composite)
acres0.690Area (User Defined)
hours0.011Computational Time
Increment
hours11.922Time to Peak (Computed)
ft³/s3.36Flow (Peak, Computed)
hours0.050Output Increment
hours11.900Time to Flow (Peak
Interpolated Output)
ft³/s3.30Flow (Peak Interpolated
Output)
Drainage Area
96.435SCS CN (Composite)
acres0.690Area (User Defined)
in0.4Maximum Retention
(Pervious)
in0.1Maximum Retention
(Pervious, 20 percent)
Cumulative Runoff
in3.4Cumulative Runoff Depth
(Pervious)
ac-ft0.197Runoff Volume (Pervious)
Hydrograph Volume (Area under Hydrograph curve)
ac-ft0.196Volume
SCS Unit Hydrograph Parameters
hours0.083Time of Concentration
(Composite)
hours0.011Computational Time
Increment
483.432Unit Hydrograph Shape
Factor
0.749K Factor
1.670Receding/Rising, Tr/Tp
Page 20 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 10 year stormLabel: CM-1
Return Event: 10 yearsSubsection: Unit Hydrograph Summary
SCS Unit Hydrograph Parameters
ft³/s9.38Unit peak, qp
hours0.056Unit peak time, Tp
hours0.222Unit receding limb, Tr
hours0.278Total unit time, Tb
Page 21 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 100 year stormLabel: CM-1
Return Event: 100 yearsSubsection: Unit Hydrograph Summary
100 year stormStorm Event
years100Return Event
hours24.000Duration
in6.5Depth
hours0.083Time of Concentration
(Composite)
acres0.690Area (User Defined)
hours0.011Computational Time
Increment
hours11.922Time to Peak (Computed)
ft³/s5.71Flow (Peak, Computed)
hours0.050Output Increment
hours11.900Time to Flow (Peak
Interpolated Output)
ft³/s5.61Flow (Peak Interpolated
Output)
Drainage Area
95.000SCS CN (Composite)
acres0.690Area (User Defined)
in0.5Maximum Retention
(Pervious)
in0.1Maximum Retention
(Pervious, 20 percent)
Cumulative Runoff
in5.9Cumulative Runoff Depth
(Pervious)
ac-ft0.337Runoff Volume (Pervious)
Hydrograph Volume (Area under Hydrograph curve)
ac-ft0.337Volume
SCS Unit Hydrograph Parameters
hours0.083Time of Concentration
(Composite)
hours0.011Computational Time
Increment
483.432Unit Hydrograph Shape
Factor
0.749K Factor
1.670Receding/Rising, Tr/Tp
Page 22 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 100 year stormLabel: CM-1
Return Event: 100 yearsSubsection: Unit Hydrograph Summary
SCS Unit Hydrograph Parameters
ft³/s9.38Unit peak, qp
hours0.056Unit peak time, Tp
hours0.222Unit receding limb, Tr
hours0.278Total unit time, Tb
Page 23 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 100 year stormLabel: CM-1
Return Event: 100 yearsSubsection: Unit Hydrograph Summary
100 year stormStorm Event
years100Return Event
hours24.000Duration
in6.5Depth
hours0.083Time of Concentration
(Composite)
acres0.690Area (User Defined)
hours0.011Computational Time
Increment
hours11.922Time to Peak (Computed)
ft³/s5.76Flow (Peak, Computed)
hours0.050Output Increment
hours11.900Time to Flow (Peak
Interpolated Output)
ft³/s5.67Flow (Peak Interpolated
Output)
Drainage Area
96.435SCS CN (Composite)
acres0.690Area (User Defined)
in0.4Maximum Retention
(Pervious)
in0.1Maximum Retention
(Pervious, 20 percent)
Cumulative Runoff
in6.0Cumulative Runoff Depth
(Pervious)
ac-ft0.347Runoff Volume (Pervious)
Hydrograph Volume (Area under Hydrograph curve)
ac-ft0.347Volume
SCS Unit Hydrograph Parameters
hours0.083Time of Concentration
(Composite)
hours0.011Computational Time
Increment
483.432Unit Hydrograph Shape
Factor
0.749K Factor
1.670Receding/Rising, Tr/Tp
Page 24 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: 100 year stormLabel: CM-1
Return Event: 100 yearsSubsection: Unit Hydrograph Summary
SCS Unit Hydrograph Parameters
ft³/s9.38Unit peak, qp
hours0.056Unit peak time, Tp
hours0.222Unit receding limb, Tr
hours0.278Total unit time, Tb
Page 25 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Index
Time-Depth - 1 (Time-Depth Curve, 2 years)...10, 11, 12, 13
Time-Depth - 1 (Time-Depth Curve, 100 years)...6, 7, 8, 9
Time-Depth - 1 (Time-Depth Curve, 10 years)...2, 3, 4, 5
T
Master Network Summary...1
M
CM-1 (Unit Hydrograph Summary, 2 years)...14, 15, 16, 17
CM-1 (Unit Hydrograph Summary, 100 years)...22, 23, 24, 25
CM-1 (Unit Hydrograph Summary, 10 years)...18, 19, 20, 21
C
Page 26 of 2627 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
APPENDIX F: BMP SIZING CALCULATIONS
TJPS Consulting Engineers - K:\Civil Projects\19JPSC26 Meridian Design Center\Drawings\BASIN.dwg August 17, 2019 - 2:29 PM Nvergatos
BMPBASIN MAPNO SCALENBVNBVNBVBMPCONSTRUCTIONDOCUMENTS19 AUGUST 201919JPSC26BMP BASINTOTAL AREA: 0.48acIMPERVIOUS: 0.44acPERVIOUS: 0.04acNEW STRUCTURALBMP
Table of Contents
6Unit Hydrograph (Hydrograph Table), 10 years
4Unit Hydrograph Summary, 10 years
CM-1
2Time-Depth Curve, 10 yearsTime-Depth - 1
1Master Network Summary
12955 Old Meridian Remodel
Subsection: Master Network Summary
Catchments Summary
Peak Flow
(ft³/s)
Time to Peak
(hours)
Hydrograph
Volume
(ac-ft)
Return
Event
(years)
ScenarioLabel
0.6011.9000.03510Water QualityCM-1
Node Summary
Peak Flow
(ft³/s)
Time to Peak
(hours)
Hydrograph
Volume
(ac-ft)
Return
Event
(years)
ScenarioLabel
0.6011.9000.03510Water QualityO-1
Page 1 of 927 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: Water QualityLabel: Time-Depth - 1
Return Event: 10 yearsSubsection: Time-Depth Curve
Time-Depth Curve: Water Quality
Water QualityLabel
hours0.000Start Time
hours0.100Increment
hours24.000End Time
years10Return Event
CUMULATIVE RAINFALL (in)
Output Time Increment = 0.100 hours
Time on left represents time for first value in each row.
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Time
(hours)
0.00.00.00.00.00.000
0.00.00.00.00.00.500
0.00.00.00.00.01.000
0.00.00.00.00.01.500
0.00.00.00.00.02.000
0.00.00.00.00.02.500
0.00.00.00.00.03.000
0.00.00.00.00.03.500
0.10.10.10.00.04.000
0.10.10.10.10.14.500
0.10.10.10.10.15.000
0.10.10.10.10.15.500
0.10.10.10.10.16.000
0.10.10.10.10.16.500
0.10.10.10.10.17.000
0.10.10.10.10.17.500
0.10.10.10.10.18.000
0.10.10.10.10.18.500
0.20.20.20.20.19.000
0.20.20.20.20.29.500
0.20.20.20.20.210.000
0.20.20.20.20.210.500
0.30.30.30.20.211.000
0.60.40.40.30.311.500
0.70.70.70.70.712.000
0.80.80.80.70.712.500
0.80.80.80.80.813.000
0.80.80.80.80.813.500
0.80.80.80.80.814.000
0.90.80.80.80.814.500
0.90.90.90.90.915.000
0.90.90.90.90.915.500
0.90.90.90.90.916.000
0.90.90.90.90.916.500
Page 2 of 927 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: Water QualityLabel: Time-Depth - 1
Return Event: 10 yearsSubsection: Time-Depth Curve
CUMULATIVE RAINFALL (in)
Output Time Increment = 0.100 hours
Time on left represents time for first value in each row.
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Depth
(in)
Time
(hours)
0.90.90.90.90.917.000
0.90.90.90.90.917.500
0.90.90.90.90.918.000
0.90.90.90.90.918.500
0.90.90.90.90.919.000
1.00.90.90.90.919.500
1.01.01.01.01.020.000
1.01.01.01.01.020.500
1.01.01.01.01.021.000
1.01.01.01.01.021.500
1.01.01.01.01.022.000
1.01.01.01.01.022.500
1.01.01.01.01.023.000
1.01.01.01.01.023.500
(N/A)(N/A)(N/A)(N/A)1.024.000
Page 3 of 927 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: Water QualityLabel: CM-1
Return Event: 10 yearsSubsection: Unit Hydrograph Summary
Water QualityStorm Event
years10Return Event
hours24.000Duration
in1.0Depth
hours0.083Time of Concentration
(Composite)
acres0.480Area (User Defined)
hours0.011Computational Time
Increment
hours11.922Time to Peak (Computed)
ft³/s0.61Flow (Peak, Computed)
hours0.050Output Increment
hours11.900Time to Flow (Peak
Interpolated Output)
ft³/s0.60Flow (Peak Interpolated
Output)
Drainage Area
99.000SCS CN (Composite)
acres0.480Area (User Defined)
in0.1Maximum Retention
(Pervious)
in0.0Maximum Retention
(Pervious, 20 percent)
Cumulative Runoff
in0.9Cumulative Runoff Depth
(Pervious)
ac-ft0.036Runoff Volume (Pervious)
Hydrograph Volume (Area under Hydrograph curve)
ac-ft0.035Volume
SCS Unit Hydrograph Parameters
hours0.083Time of Concentration
(Composite)
hours0.011Computational Time
Increment
483.432Unit Hydrograph Shape
Factor
0.749K Factor
1.670Receding/Rising, Tr/Tp
Page 4 of 927 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: Water QualityLabel: CM-1
Return Event: 10 yearsSubsection: Unit Hydrograph Summary
SCS Unit Hydrograph Parameters
ft³/s6.53Unit peak, qp
hours0.056Unit peak time, Tp
hours0.222Unit receding limb, Tr
hours0.278Total unit time, Tb
Page 5 of 927 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: Water QualityLabel: CM-1
Return Event: 10 yearsSubsection: Unit Hydrograph (Hydrograph Table)
Water QualityStorm Event
years10Return Event
hours24.000Duration
in1.0Depth
hours0.083Time of Concentration
(Composite)
acres0.480Area (User Defined)
HYDROGRAPH ORDINATES (ft³/s)
Output Time Increment = 0.050 hours
Time on left represents time for first value in each row.
Flow
(ft³/s)
Flow
(ft³/s)
Flow
(ft³/s)
Flow
(ft³/s)
Flow
(ft³/s)
Time
(hours)
0.000.000.000.000.002.700
0.000.000.000.000.002.950
0.000.000.000.000.003.200
0.000.000.000.000.003.450
0.000.000.000.000.003.700
0.000.000.000.000.003.950
0.000.000.000.000.004.200
0.000.000.000.000.004.450
0.000.000.000.000.004.700
0.000.000.000.000.004.950
0.000.000.000.000.005.200
0.000.000.000.000.005.450
0.010.000.000.000.005.700
0.010.010.010.010.015.950
0.010.010.010.010.016.200
0.010.010.010.010.016.450
0.010.010.010.010.016.700
0.010.010.010.010.016.950
0.010.010.010.010.017.200
0.010.010.010.010.017.450
0.010.010.010.010.017.700
0.010.010.010.010.017.950
0.010.010.010.010.018.200
0.010.010.010.010.018.450
0.010.010.010.010.018.700
0.010.010.010.010.018.950
0.010.010.010.010.019.200
0.010.010.010.010.019.450
0.020.010.010.010.019.700
0.020.020.020.020.029.950
0.020.020.020.020.0210.200
0.020.020.020.020.0210.450
0.030.030.030.030.0210.700
Page 6 of 927 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: Water QualityLabel: CM-1
Return Event: 10 yearsSubsection: Unit Hydrograph (Hydrograph Table)
HYDROGRAPH ORDINATES (ft³/s)
Output Time Increment = 0.050 hours
Time on left represents time for first value in each row.
Flow
(ft³/s)
Flow
(ft³/s)
Flow
(ft³/s)
Flow
(ft³/s)
Flow
(ft³/s)
Time
(hours)
0.030.030.030.030.0310.950
0.050.040.040.040.0411.200
0.150.100.070.050.0511.450
0.600.460.330.260.2011.700
0.100.150.320.480.5611.950
0.060.060.070.080.0812.200
0.040.040.040.050.0512.450
0.030.030.040.040.0412.700
0.030.030.030.030.0312.950
0.020.030.030.030.0313.200
0.020.020.020.020.0213.450
0.020.020.020.020.0213.700
0.020.020.020.020.0213.950
0.020.020.020.020.0214.200
0.020.020.020.020.0214.450
0.010.020.020.020.0214.700
0.010.010.010.010.0114.950
0.010.010.010.010.0115.200
0.010.010.010.010.0115.450
0.010.010.010.010.0115.700
0.010.010.010.010.0115.950
0.010.010.010.010.0116.200
0.010.010.010.010.0116.450
0.010.010.010.010.0116.700
0.010.010.010.010.0116.950
0.010.010.010.010.0117.200
0.010.010.010.010.0117.450
0.010.010.010.010.0117.700
0.010.010.010.010.0117.950
0.010.010.010.010.0118.200
0.010.010.010.010.0118.450
0.010.010.010.010.0118.700
0.010.010.010.010.0118.950
0.010.010.010.010.0119.200
0.010.010.010.010.0119.450
0.010.010.010.010.0119.700
0.010.010.010.010.0119.950
0.010.010.010.010.0120.200
0.010.010.010.010.0120.450
0.010.010.010.010.0120.700
0.010.010.010.010.0120.950
0.010.010.010.010.0121.200
Page 7 of 927 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Storm Event: Water QualityLabel: CM-1
Return Event: 10 yearsSubsection: Unit Hydrograph (Hydrograph Table)
HYDROGRAPH ORDINATES (ft³/s)
Output Time Increment = 0.050 hours
Time on left represents time for first value in each row.
Flow
(ft³/s)
Flow
(ft³/s)
Flow
(ft³/s)
Flow
(ft³/s)
Flow
(ft³/s)
Time
(hours)
0.010.010.010.010.0121.450
0.010.010.010.010.0121.700
0.010.010.010.010.0121.950
0.010.010.010.010.0122.200
0.010.010.010.010.0122.450
0.010.010.010.010.0122.700
0.010.010.010.010.0122.950
0.010.010.010.010.0123.200
0.010.010.010.010.0123.450
0.010.010.010.010.0123.700
(N/A)(N/A)(N/A)0.010.0123.950
Page 8 of 927 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
12955 Old Meridian Remodel
Index
Time-Depth - 1 (Time-Depth Curve, 10 years)...2, 3
T
Master Network Summary...1
M
CM-1 (Unit Hydrograph Summary, 10 years)...4, 5
CM-1 (Unit Hydrograph (Hydrograph Table), 10 years)...6, 7, 8
C
Page 9 of 927 Siemon Company Drive Suite 200 W
Watertown, CT 06795 USA +1-203-755-1666
8/17/2019
Bentley PondPack V8i
[08.11.01.56]
Bentley Systems, Inc. Haestad Methods Solution
Center12955 Old Meridian Remodel Run-Off.ppc
City of Indianapolis Stormwater Quality Unit (SQU)
Selection Guide
Pg. 2 01/02/19
Version 13.0
Manufactured
SQU SQU System Model
Max
Treatment
Flow
(cfs)
Max 10-yr
On-Line
Flow Rate
(cfs)
Cleanout
Depth
(Inches)
9000 7.59 N/A 30
11000 9.88 N/A 30
16000 15.59 N/A 30
PC1319 or 1319 CIP 19.04 N/A 30
PC1421 or 1421 CIP 22.92 N/A 30
1522 CIP 27.23 N/A 30
1624 CIP 32.00 N/A 30
1726 CIP 37.24 N/A 30
1827 CIP 42.96 N/A 30
1929 CIP 49.17 N/A 30
2030 CIP 55.90 N/A 30
2131 CIP 63.15 N/A 30
2233 CIP 70.94 N/A 30
2334 CIP 79.28 N/A 30
2436 CIP 88.18 N/A 30
2538 CIP 97.66 N/A 30
2639 CIP 107.72 N/A 30
2740 CIP 118.37 N/A 30
2842 CIP 129.64 N/A 30
2943 CIP 141.53 N/A 30
3045 CIP 154.05 N/A 30
3146 CIP 167.21 N/A 30
3349 CIP 195.49 N/A 30
3958 CIP 296.83 N/A 30
4060 CIP 316.23 N/A 30
Aqua-Swirl™
2,3
AS-2 0.26 N/A 24
AS-3 0.50 N/A 32
AS-4 0.98 N/A 32
AS-5 1.47 N/A 32
AS-6 2.32 N/A 32
AS-7 3.40 N/A 32
AS-8 4.75 N/A 32
AS-9 6.38 N/A 32
AS-10 8.30 N/A 32
AS-11 10.54 N/A 32
AS-12 13.10 N/A 32
AS-13 16.00 N/A 32