HomeMy WebLinkAboutE100.0R R R
R R R
R
R
R
R
R R
R
R
R
DM
DM
DM
SD
CO
SD
1'-10 1/2"
4'-10 1/8"
2'-0"2'-5 1/4"2'-3" 3/4"5'-6 3/4" 1'-3 5/16"4'-1 15/16" 7'-3 9/16"4'-9 15/16" 11'-11 13/16" 1'-2 1/4"
5 9/16"5'-4 7/16" 4'-9 15/16"UNFINISHED SPACE
UNFINISHED STORAGE
SPACE
BASEMENT BEDROOM
BASEMENT HALL
BASEMENT
BATH
SEMI FLUSH
TO REMAIN
FIELD VERIFY NEW CARBON MONOXIDE /
SMOKE DETECTOR LOCATION PER CODE
BASEMENT LIVING ROOM
CLOSET
SPACE ELECTRICAL OUTLETS PER CODE FOR
NEW BEDROOM
DM
USB
R
SD
GFCI
R
CO
FAN/CAN
LEGEND-ELECTRICAL
LIGHTING
6" LED CANS
SWITCHES
COMMUNICATION
MISCELLANEOUS
SMOKE DETECTOR
FIELD VERIFY EXISTING SMOKE DETECTORS AND
CARBON MONOXIDE DETECTORS ARE TO CODE; ANY
UPDATES TO BE DONE AS TIME AND MATERIALS
ALL WORK TO BE CONFORM TO THE NEC AND
ALL LOCAL APPLICABLE CODES.
EXACT DEVICE LOCATIONS SUBJECT TO JOB
CONDITIONS.
METER LOCATION TO BE DETERMINED BY
LOCAL UTILITY COMPANY.
GENERAL NOTES
OUTLETS
NEW OUTLETS
GFI OUTLET
WHITE OUTLET & SWITCH COVER PLATES
CEILING FAN
VANITY FIXTURE
WALL MOUNT
EXISTING BARE BULB AND
SEMI FLUSH LIGHTS TO
REMAIN
TERMINATE ANY TELEPHONE
JACKS OR CAT5 OUTLETS
HEATED FLOOR SYSTEM ON
DEDICATED CIRCUIT
USB OUTLET
NEW SWITCH
NEW DIMMER SWITCH
ASSUMED NEW CARBON
MONOXIDE DETECTOR
ASSUMED NEW SMOKE
DETECTOR
#1
of
10
Date:
3.5.20
Sheet:
Revision:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been
prepared by Case Design &
Remodeling solely for its use and
should not be reproduced or relied
upon by any other parties.
Dimensions shown or scaled are
subject to change per actual job
condition and must be verified.
Materials are to be supplied as
specified as equal or standard
when not uniquely specified.
Installed materials may vary in
appearance from drawings.
Reference manufacturer's product
data for actual appearance and
specifications.Goldman ResidenceBasement RemodelDana & Mitchell Goldman14051 Knightstown Dr. West, Carmel, IN 46033Approved By:
Date:
E101
FINAL
#4
2.27.20
6.15.20
7.6.20
Maggie Smith
Designer
msmith@caseindy.com
Sydney Spurgeon
Project Developer
sspurgeon@caseindy.com
ELECTRIC PLAN
SCALE: 1/4" = 1'
#2
#3
EELLEECCTTRRIICC NNOOTTEESS
BASEMENT BATHROOMBASEMENT BATHROOM
F/I (1) NEW VANITY SCONCE FIXTURE & (1) NEW RECESSED CAN ON NEW DIMMER
SWITCH
F/I (1) NEW EXHAUST FAN/ CAN COMBO ON NEW SWITCH
F/I (1) NEW GFCI OUTLETS AT VANITY
BASEMENT BEDROOMBASEMENT BEDROOM
F/I (5) NEW RECESSED CANS IN NEW LOCATION ON NEW DIMMER SWITCH
F/I (1) NEW CEILING MOUNT FAN IN NEW LOCATION ON NEW SWITCH
F/I (5) NEW OUTLETS IN NEW LOCATIONS
BASEMENT UNFINISHED SPACEBASEMENT UNFINISHED SPACE
F/I (2) NEW BARE BULBS ON RELOCATED SWITCH IN UNFINISHED STORAGE SPACE
RELOCATE EXISTING BULB & SWITCH TO NEW LOCATION
ELECTRICAL UPDATE 8.10.20 #5 8.10.20
08/10/20
Adam Schriner