Loading...
HomeMy WebLinkAboutM000.1RELEA51 Su6jec� � DATE: Mechanical Symbols and Abbreviations Abbreviations Drawing Symbols Sheet Metal Symbols ACC ACCU AFF AHU AS B BCC BDD BOD G CC CD CEF CFM CUH GHWP CHWR CHWS CT CP CW oa OOAS OSAC 0 EDB EWB EBR EC ECH ECR EDC EF EG EH ER ERV ESP EVC EWH F FD $D FLA FPM FPVAV FT FTR G GC GPM H HDR HRB HRU HP HWP HWR HWS HX N KEC LAT LS MAN MAU MFR MBH MC O/A OAL PD P51 RA RO RG RPM RTU SA SBCC SDG SP SR SVK TCC TSP UH VAV VD WB WT XT air cooletl contlenser air cooletl contlensing uni� above finish floor air hantlling unit airsaparator boller (hot water or steam7 branch cifcui�con�roller backdrak tlamper botlom of tluc� chiller cabine� convec�or ceii ng difluser (supply air) ceiling exhaustfan cubic �eet pe� minWe cebine� uni� hee�er (slechic or hw) chilletl water pump chilled water reWrn chilled watersupply coolingtower contleneata pump (s�eem) coltl water tlry bulb tlediwtetl outdoorairsys[em tluqless spli� air conditioner diameter en�ering airdry bulb en�ering airwelbulb electric baseboartlradia�ion Electrical Con�ractor elecVlc cabinetheatar eggcra[e grille eledric duct coil exhausifan axhaustgnlie exhaust hood axhaust reBister energyrecovery ventilator ex[emals[atic pressure evapora�ive cooler elec[ric well heater fumace �ire tlamper fire and smoke damper full loatl amps feetperminute fan powered variable air volume box �oo� fin Wbe radiation qas GenerelContractor gallons perminute humitlifier heavy dNy regis�er or grille heat recovery box variable refrigerent heat recovery uni� heat pump hot water pump hot water reW m hot water suppty heatexchanger inch kitchen equipment conVactor leaving air [emperaW re linear slot tliftuser manual make up air uni[ ManufacWrer 1000 BTUh Mechanical Contractor omsitle air ou�sitle air lower plaque di0user pountls persquareinch remm air round tli(fuser reNm air grille revolu0ans perminute roof �op uni� supply air sub branch cirwi� con�mller spiral tluc� grille sta[ic pressure supply register solenoid valve kl� TemperaWre Comml Conhacmr �o[als�a[ic pressure uni� heater variable airvolume box volume tlamper we� bulb weigh� expansian tank Mechanical General Notes APPLICABLE CODES AND ORDINANCES: Pmvitle all materials antl equipmen[ antl pedorm all labor requiretl to inslallcomplete antl operable mechanicalsystems asintlicated onthe tlrawings, as specilietl antl as requiretl by cotle. En�ire inslallation shall be in sVict accortlance wi[h applicable cotles and ordinances. Secure and pay for all required permits. Provide a minimum of 10'-0" between exhaust outlets. plumbing vents antl alloutside airintakes. Provide a minimum of 3'-0" beWeen exhaust outlets and operable wintlows or tloors. GanVactor shall not loca�e any tluc� or piping tlirectly over any elecVical panel. switchgeaq Iransformer, etc. Coordinate lowtions of tlucts antl piping wi�hthe ElecViwlConVactorto avoitl Nese mn�licts. AS-BUILT DRAWINGS: GonVector shall maln[ain a set o! tlrawinge �he� tlocumen[ �ieltl changes to [hese tlrawings. antl shall submit them to the ArchitecVEngineer as part of the pmlect close out. ARCHITECT: GanVactorshall be guitletl bythe Archi�ecfsreflec[etl ceiling planfor exactlowtion ofdifNsers,registers and grilles unless otherwise noted. Furnish all material and equipment as specified, excep� where specific substiWtionis proposed.antl reviewed bythe ArchitecVEngineer. GENERAL: Do not opera�e new HVAC systems until tlrywall santling is complete and primetl, and jobsite dust is no longer signilicanL Constmction dust is ex�remely tleVimen�al to �he long �erm operation of �he HVAC system. Provide temporary heating or cooling/dehumidifica�ion sys�ems during tons�mc�ion if it is desired or required. These drawinqsintlicaterequired sizes and poin�s of�erminationfor piping, ductwork. conduit, etc. The equipment shown illuslretes suggested routing, but all necessary offsels and fittings may not be shown. ConVactor shall install his work in a manner that will conform wi�h�he s�mcNre. Con�rac�orshall avoid obsVuc�ions,preserve head room and main�ain maximum clearance without atltlitional cost to the Owner. All dimensions shown on these plans are in fee� antl/or inches unless o�herwise notetl. Mechanical work shall be complete in every detail and all miscellaneous i�ems of ma�erial antl labor necessary �o comple�e the work tlescribetl,shown orreasonablyimplietl on drawings or specifications, shall be included in the contrect. ConVact document drawings tor mechanical work are diagremmatic antl are imentled �o convey scope antl general arrangement only. Install all mechanical equipment and appurtenances in accortlance wi�h ManulacNrers'recommenda�ions, con�rac� documen�s, and applicable cotles and regulations. Provide vibration isolation as specifietl for all mechanical equipment to prevent Vansmission of vibration �o buildinq strucNre. Coordina�e construc�ion of all mechanical work wi�h Archi�ecWral, StmcWral,Civil, ElecVicalwork, etc.,shown on otherconhact document drewinas. 0 FOR CONSTRUCTION :,a�,o,�ha,,,e,esPo��;,,a,o,�oo,,;�a,;�9,he 'k with the work of other conVacrors and Vades compliance with allregula�ions f S�a�e antl Local Codes City of Carmel �un��\i lo•rvalM��. 08/13/20 prior to �he installation. Mainlain a minimum of 6'-8" dearance to untlerside o! tlucts, contluits. suspendetl equipmenp etc., throughout access routes in mechanical moms. AO tests shall be completetl before any mechanical equipment or pipinginsulationis applied. Work shallinclutle s[atlup otallsystems,furnishing ofopereting antl mainlenence ineVucOons entl ona (1) year guarentea, cammancing on date of acceptance by the Owner or as otherwise specified. Where two or more items of the same type of equipmen[ are required. [he pmtluct of one ManufacWrer shall be usetl unless atherwise notetl. Coortlina[e all equipmenl connec[ions wiN ManufacWrers' certifietl drawings. Coordinate antl provide allduct[ransitions requiretllorfinal equipment connections �o furnishetl equipmenL Fieltl veri�y antl coordinate all tluct dimensions before (abriwtion. The locations of all i�ems shown on the tlrawings or called �or in �he specifiwtions [hat are not tle�ini�ely fixetl by tlimensions are appmximate only. The exact bcations necessary lo sewre the best conditions antl resulls mus� be tleterminetl by [he prolect site contli[ions antl shall have the approval ol the Engineer bePore being installetl. Oo not scale tlrawings. Allmiscellaneous steelrequiretl[o ensure properinstallation for equipment shall be Wmished and installed by the Mechanical ConVactor. All equipmen� shall be supportetl as tletailed, specifietl, andbr requiredto provitle a vibrationfreeinstallation. Mechanical equipmen� shall no[ be suppotletl hom me�al tleck. All mof mounted equipment curbs lor equipment pravidetl by the Mechanical Contrac�or shall be furnished by �he Mechanical ConVactorantlinstalletl bylhe General ConVactor. Lowtions antl sires of all flooq wall, and roo! openings shall be coordina�ed wi�h allo�herVades. All openings in lire walls due �o duchvork, piping, condui�, e�c., shall be lire stopped with a product similar to 3M or equal. Protluct shall be lis�ed by UL or FM and mee��he requirements oflocaland s�a�e cotles. All air conditioning condensate drain lines from each air handling unit or mopop uni� shall be piped full sire ol �he uni� drain oulle�, wi�h "P" hap, and piped to the nearest drain or mo! tleck. See details shown on the drawings or the contratt spetifications for depth of air conditioning contlensate Vaps. Retertotypicaltletails�or equipmentinstallalion. Furnish and install all equipment and material required to complete the installa�ion as shown on�he tlrawinqs. Equipment sizes, weights, poweq geomeVy and service space requirements may vary between tlilferent ManufacWrers. Consult appmved ManulacWrer drewings as submiVed and coordina�e wi�h [hese tlrawings. It shall be the ConVactoYs responsibility to bear the CO5�5 d550Cid�2d Wi�h�h15 COOIdIlIdIi011. Loca�e all mechanical equipmen� (RTUs, e�c.) for unobs�ruc�ed access [o uni� access panels, contmis, antl valving. Reter m mechanical details tor adtlitional equipment requirements. Power for all mof�op units shall be wiretl by [he ElecVical ConVactor and shall be placed on a dedicated cirail. Denotes sec[ion � �Sec�ion number s, M� �Shee�number Arrowindicates Direction Where seMion in which Section is cut s loca�ed Deno�es tle�ail � � pe�ail number o i M� �Sheetnumber Deno�es W here tletail Consimction � Statl poin� � Plan Notes'. SpeciYiciniormation asindicated on a tlrawing LeatleNine oiplan no�ereferencetl directetl ro item of plan note reference 1 :— Circie with numberintlicates a pian no�e refarenae, with �ha numbar Intlicating ihe item number ot ihe plan no�ereferencetl Generel Plan No�es: General information as i� perlains only �o the drawing i� is on General Notes: Generalintormation pertaining �o allihe tlrawings oflhe tliscipline it is on Loca[e roo�lop uni�s on root Coortlinate with s[mcWral plans. Set units as requiretl ro allow supply and re[um openings m dear mo! s�mcWre. Furnish antlinstallrain hoods onflues antlintake ducts above mof. Mechanical ConVactor shall Wmish antl ins[all a 3"x3"x%" sleel angle frame amuntl each mottop unit mo! opening Field weltl Games to [op of joists. Loca[e roo�lop uni�s on roof so tha� the duct dmps will clear the roof stmcWre. RELATED ELECTRICAL AND PLUMBING: Unlasa otherwise natetl ell low voltege witlng (24 volte) ahell be provided andinstalled bythe Mechanical ConVactor. Thisindudes fans, ratliant heaters, rooftop units, etc. Unlasa otherwise natetl line valte e wirin 120 volte or reater ahell 9 91 9 1 be pmvided and installed by the ElecVical ConVactor. Wiring should be concealetl at all times unless olhervuise notetl on �he plans. Contact the Engineer if concealment is not possible. All conVol wire and conduit shall comply with the National ElecVic Code (NEC) entl Divieion 16/26 of the apaclfiwtlone. Gontlensale tlrain pipe mn out shall be full size to the nearest tlrain. Referto"P"sheetsforrouting. Coordinateinstalla[ion ofgas pipingfor HVAC uni5 wi[h Plumbing GonVactor. Furnish antl install a gas cock at each unit connec�ion. Referta elecVical antl plumbing tlrawingsforatltlitionalcoortlination withthese drawings. Any uni� supplied with naWral or LP gas shall be Wmishetl wi�h pressureregulators by UnilManufac[urer. APPEARANCE: All equipment should be installed with great reqard to a neat finished P roduct. Whenever possible, wiring shoultl be muted in such a way as to minimize visibili�y. Con�ad the Engineer prior �o inslalling any equipmen� �ha� will no� be ableto beinstalletlin a neat,�irs�class manneq consistentwiththe ManufacWrer'sins�alla�ioninstruc�ions. RELATED GENERALCONSTRUCTION: Unless otherwise noted flashing of wof openings will be done by the General ConVactor. Deliver moltop unit antl exhaust fan curbs to GenerelConVadorforins�alla�ion. ContactGeneralCon�redor�o coortlina�e this potlion o! the work. Fire damper Volume damper Supply tli�tuser Suppty tluR nser ReWrn tlud riscr Supply ragister Lineardiffuser Flexible conneqion ReW rn air grille Exhausigrille Exhaus��an Square Elbow with Turmng Vanes Rac�angularta rountl tlucthansi0on Room thermos�a� or sensor Room humitlistat or sensor Motonzed tlamper SUBSTITUTIONS: Cost of any changes requiretl by Nis, or o[her hatles, due to substiWtion ol equipment other than the basis of design, shall be inclutletlinthe Mechanical Gonlractor's proposal. UTILITIES: Unless otherwise noted the lowl gas company shall provitle gas m[he builtling antl lurnish antl install the meler. Connection to the meter and extensian ofthe piping shallbe madein accortlance withthe utiliry company requirements. Contactlocalutility companyto arrange�or gas meterinslallation. Fumish antl installpiping antl specialties as requiretl m receive meter. Verifylocalcontli�ions atthe si[e. RELATED CONTROLS: Unless otherwise noted.loca�e all roomthermos[ats antl humitlistats 4'-0" (centerllne) above Mish flooc Notlty �he Englneer prior to ins�allatian of any moms where the above location cannot be mainlained orwherelhereis a queslion onlocation. All contml wiring and related conVol componen�s shoultl be concealed unless otherwise notetl on Ne plans. Contactthe Engineerif concealmentis notpossible. TEMPORARY SERVICE: Equipment providetl as patl o! this conVact should not be used for heating/coolingNenWatlon oftha pro�ectptlorto ell aentling baing complete, antl at leas� 1 coat o! pain� on all sur�aces. The inten� of this la to preven� tha infllVetlon of conaVuction tluatlnto �ha heefing / cooling coils and causing long term pedormance or reliability issues. � i�a � �Ofl❑� .......�........ .......m...... � � �� ...� ....... � 0 � � � 01P � � w� �� U � � �� U U� w � Q �� U 2 � � C U� LL + �� � W � r�n U VJ � CONSTRUCTIONDOCUMENTS aci amc° .. u�in9. udB �91D20 rrewsioms�ssueo ARCHITECT/ LANDSCAPE ARCHITECT: SITE ARCHITECTURE etinnam��. a�m�aaeatin�m�re PROJEQCONTHCT�. BRA�SMITH RA LEE�AP 13t4a EASTie6TH STREET NOBLESVILLE M.06060 PN'. 31] Wa e�20 EJr1AIC. brztl@sl�e-amM1IM1 �edure_mm STRIICTURALENGINEER: STRUCTURAL �ESIGN, INC. PROJECTCONTACT: CHARLES P.SCHAEFER,P.E. ]2]i W. 115 5$ SORE B NEW PALESTWE IN.46163 PH-0�I8B1 ]]08 EMAILIcsonaefer�siruo�tleslqn.rqm MEP ENGINEER: THE ENGINEERING COLLABORATNE PROJECTCONTACT: SHM HURT, P.E. 2410 EXECIITIVE DRIVE,SUITEIO� INDIANAPOLIS,IN.46241 PR 0�] 638 994� EMAIL'. sam�teemep.com NL i Z W G W � O a� Na Q � � J W aZ� W Z N M �W2r� � ` � o � T � Z � � � J O�WW 0�/ � � � LL X � Q mW�c� IHVAC GENERALNOTESI M 100 20�9-031I