Loading...
HomeMy WebLinkAboutE100.01901 North Roselle Road, Suite 1000Schaumburg, Illinois 60195Pulte Central Zone102/05/2016PLAN REVISIONS........................ PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2017 Joel Hampshire3/30/2015 GARAGE LEFT 3007-Turin TBD -- 01/02/2017 PLOTTED: January 3, 2017 / Mike Carney / 3007-IN-MEPP.DWG First Floor - Elevation 1 - TurinElectrical Plans6.10 \A1;26'-11{\H0.750000x;\S1#2;}" CHCH CH CH CH CHCH CH CH CH FIREPLACE NOTES:\P\P\pxt0;PROVIDE OUTSIDE COMBUSTION AIR TO THE FIREPLACE. ALL FACTRORY-BUILT OR MASONRY FIREPLACES SHALL BE EQUIPPED WITH AN EXTERIOR AIR SUPPLY ONLY TO ASSURE PROPER FUEL COMBUSTION.\P\ptz;\PTHE FIREPLACE CHASE SHALL BE FIRE STOPPED AT EACH FLOOR /CEILING LEVEL WHEN THE CHASE EXCEEDS THE HEIGHT OF A SINGLE STORY. \P\PTHE FIREPLACE CHASE SHALL BE INSULATED, WITH A MIN. OF AN R-13 UN-FACED INSULATION, UP TO THE FIRST FIRE STOP IN THE CHASE. \P\PTHE GAS LINE PENETRATING THE INTERIOR WALL OF THE FIREPLACE SHALL BE GROUTED SOLID. \A1;4'-1" S FAN/LIGHT, VENT \PTO EXT. RWP\PGFI 3S 220V GFI SGFI WP/GFI S3S R TO LIGHT ABOVE S SSGFI FAN, VENT TO EXT. GFI GFI S DWRGFISDISPS FIRST FLOOR ELECTRICAL PLAN1/4" = 1'-0" GFI DED. S SFAN, VENT \PTO EXT. SSS RS SSS S 3S R 3S3S S S GFI GFI GFI GFIGFIGFIGFIGFI DED. R RR R RR WP/GFIS3S 3S3S R 3S 3S TO LIGHT ABOVE 3S 3S 3S R R R PH TV TV PH S/C GFI GDOGDO SOPT. FAN, VENT \PTO EXT. \pxql,t1;{\T0.9;ALL ELECTRICAL INSTALLATION SHALL MEET THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE (N.E.C.). ALL MATERIAL AND EQUIPMENT SHALL BEAR THE LABEL OF APPROVAL OF THE UNDERWRITERS LABORATORIES, INC. AND MEET THE REQUIREMENTS OF THE N.E.C..\P\P1. STAIRWAYS WITHIN DWELLING UNITS SHALL HAVE AN ILLUMINATION LEVEL ON THE TREAD RUNS OF NOT LESS THAN 1 FOOTCANDLE. PROVIDE LIGHTING CONTROL AT EACH LEVEL. EXTERIOR STAIRWAYS SERVING A DWELLING UNIT SHALL HAVE A LIGHT IN THE IMMEDIATE VICINITY OF THE STAIR LANDING CLOSEST TO THE DWELLING UNIT. \P\P2. GFI PROTECTION SHALL BE PROVIDED FOR ALL 125 VOLT, SINGLE PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED IN THE FOLLOWING LOCATIONS:\P - BATHROOMS\P - GARAGE\P - OUTDOORS: BALCONIES, DECKS, AND PORCHES (INCLUDING INSIDE SCREENED ENCLOSURES)\P - UNFINISHED BASEMENT AREAS AND CRAWL SPACES, EXCEPT FOR LAUNDRY CIRCUIT AND SINGLE RECEPTACLE DEDICATED TO SUMP PUMPS\P - RECEPTACLES INTENDED TO SERVE KITCHEN COUNTER TOP SURFACES\P - RECEPTACUTILITY NOTESElectrical Schedule TableSymbol Type Additional Notes S/CS PCR 220VDWGFIPHTVWP/GFISDISPS3SDETECTOR - SMOKE/CARBON MONOXIDE COMBINATIONDETECTOR - SMOKEFAN - CEILING W/ LIGHTFAN - EXHAUSTFAN - EXHAUST W/ LIGHTFAN - EXHAUST-VENT TO EXTERIORLIGHT-CEILING-PULLCHAINLIGHT - CEILINGLIGHT - RECESSEDLIGHT - WALLOUTLET - 220VOUTLET - DISHWASHEROUTLET - DUPLEXOUTLET - DUPLEX-SPLIT WIREDOUTLET - GFIOUTLET - PHONEOUTLET - TVOUTLET - WATERPROOF-GFISWITCH - DISPOSALSWITCH - LIGHTSWITCH - THREE WAY UL APPROVED CEILING MOUNTED SMOKE /CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER R314.4)110V W/ BATTERY BACKUP\PINTERCONNECTEDFAN BOX PER NEC. PROVIDE 4-WIRE CABLE FROM SWITCH(ES) (CLG FAN OPTIONAL)50 CFM MIN INTERMITTENT FAN EXHAUST TO EXTERIORCAT 5ERG-6 2 can lights standard ilo hanging fixture Reference Elevation Pages for Electrical in this area not applicable in Indiana08/13/20 William Hohlt