PLOTTED: January 3, 2017 / Mike Carney / 3007-IN-MEPP.DWG First Floor - Elevation 1 - TurinElectrical Plans6.10
\A1;26'-11{\H0.750000x;\S1#2;}"
CHCH
CH
CH
CH
CHCH
CH
CH
CH
FIREPLACE NOTES:\P\P\pxt0;PROVIDE OUTSIDE COMBUSTION AIR TO THE FIREPLACE. ALL FACTRORY-BUILT OR MASONRY FIREPLACES SHALL BE EQUIPPED WITH AN EXTERIOR AIR SUPPLY ONLY TO ASSURE PROPER FUEL COMBUSTION.\P\ptz;\PTHE FIREPLACE CHASE SHALL BE FIRE STOPPED AT EACH FLOOR /CEILING LEVEL WHEN THE CHASE EXCEEDS THE HEIGHT OF A SINGLE STORY. \P\PTHE FIREPLACE CHASE SHALL BE INSULATED, WITH A MIN. OF AN R-13 UN-FACED INSULATION, UP TO THE FIRST FIRE STOP IN THE CHASE. \P\PTHE GAS LINE PENETRATING THE INTERIOR WALL OF THE FIREPLACE SHALL BE GROUTED SOLID.
\A1;4'-1"
S
FAN/LIGHT, VENT \PTO EXT.
RWP\PGFI
3S
220V
GFI
SGFI
WP/GFI
S3S
R
TO LIGHT ABOVE
S
SSGFI
FAN, VENT TO EXT.
GFI GFI
S
DWRGFISDISPS
FIRST FLOOR ELECTRICAL PLAN1/4" = 1'-0"
GFI
DED.
S
SFAN, VENT \PTO EXT.
SSS
RS
SSS
S
3S
R 3S3S
S
S
GFI
GFI
GFI GFIGFIGFIGFIGFI
DED.
R RR
R RR
WP/GFIS3S
3S3S
R
3S
3S
TO LIGHT ABOVE
3S
3S
3S
R
R
R
PH
TV
TV
PH S/C
GFI
GDOGDO
SOPT.
FAN, VENT \PTO EXT.
\pxql,t1;{\T0.9;ALL ELECTRICAL INSTALLATION SHALL MEET THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE (N.E.C.). ALL MATERIAL AND EQUIPMENT SHALL BEAR THE LABEL OF APPROVAL OF THE UNDERWRITERS LABORATORIES, INC. AND MEET THE REQUIREMENTS OF THE N.E.C..\P\P1. STAIRWAYS WITHIN DWELLING UNITS SHALL HAVE AN ILLUMINATION LEVEL ON THE TREAD RUNS OF NOT LESS THAN 1 FOOTCANDLE. PROVIDE LIGHTING CONTROL AT EACH LEVEL. EXTERIOR STAIRWAYS SERVING A DWELLING UNIT SHALL HAVE A LIGHT IN THE IMMEDIATE VICINITY OF THE STAIR LANDING CLOSEST TO THE DWELLING UNIT. \P\P2. GFI PROTECTION SHALL BE PROVIDED FOR ALL 125 VOLT, SINGLE PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED IN THE FOLLOWING LOCATIONS:\P - BATHROOMS\P - GARAGE\P - OUTDOORS: BALCONIES, DECKS, AND PORCHES (INCLUDING INSIDE SCREENED ENCLOSURES)\P - UNFINISHED BASEMENT AREAS AND CRAWL SPACES, EXCEPT FOR LAUNDRY CIRCUIT AND SINGLE RECEPTACLE DEDICATED TO SUMP PUMPS\P - RECEPTACLES INTENDED TO SERVE KITCHEN COUNTER TOP SURFACES\P - RECEPTACUTILITY NOTESElectrical Schedule TableSymbol
Type
Additional Notes
S/CS PCR 220VDWGFIPHTVWP/GFISDISPS3SDETECTOR - SMOKE/CARBON MONOXIDE COMBINATIONDETECTOR - SMOKEFAN - CEILING W/ LIGHTFAN - EXHAUSTFAN - EXHAUST W/ LIGHTFAN - EXHAUST-VENT TO EXTERIORLIGHT-CEILING-PULLCHAINLIGHT - CEILINGLIGHT - RECESSEDLIGHT - WALLOUTLET - 220VOUTLET - DISHWASHEROUTLET - DUPLEXOUTLET - DUPLEX-SPLIT WIREDOUTLET - GFIOUTLET - PHONEOUTLET - TVOUTLET - WATERPROOF-GFISWITCH - DISPOSALSWITCH - LIGHTSWITCH - THREE WAY
UL APPROVED CEILING MOUNTED SMOKE /CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER R314.4)110V W/ BATTERY BACKUP\PINTERCONNECTEDFAN BOX PER NEC. PROVIDE 4-WIRE CABLE FROM SWITCH(ES) (CLG FAN OPTIONAL)50 CFM MIN INTERMITTENT FAN EXHAUST TO EXTERIORCAT 5ERG-6
2 can lights standard ilo
hanging fixture
Reference Elevation Pages
for Electrical in this area
not applicable in Indiana08/13/20