HomeMy WebLinkAboutDepartment Report 08-18-201
CARMEL PLAN COMMISSION
DEPARTMENT REPORT
AUGUST 18, 2020
1. Docket No. PZ-2020-00076 DP/ADLS: Avant Phase II
The applicant seeks site plan and design approval for a multi-family building with 94 apartments. (14 townhome
plots are also shown on this DP, but additional applications will be filed for Secondary Plat & ADLS approval at a
later date.) The building is 135,243 gross sq. ft. and 4 stories/55’4” tall. The overall site is 3.82 acres in size. It is
located just north of 12890 Old Meridian Street (Avant Phase I) and is zoned PUD (The District Z-587-14). Filed
by Steven D. Hardin, Esq., with Faegre Drinker, on behalf of Edward Rose Development.
Project Overview:
The Petitioner proposes to construct the second phase of the Avant multi-family apartment development. Also included in
this development plan are 14 lots for future townhomes. To the immediate south of this building is the open space/pond
area for the entire PUD development. To the west are townhomes and the Fairfield Inn & Suites hotel. All land west and
south are zoned PUD, part of the same “The District” PUD. North is the Olivia mixed use development, zoned UC/Urban
Core. To the east across Old Meridian Street is the Meridian Design Center commercial buildings, home to Bru Burger
and Rise restaurant, under construction currently and zoned UC/Urban Core. Please refer to the Petitioner’s
informational packet for more details.
Planned Unit Development (PUD) Standards this project MEETS:
• Permitted uses – Multiple Family Dwellings and
Attached Dwellings
• Minimum building height – 28’ and 2 occupiable floors
required, 4 stories proposed
• Max. building height – 70’ allowed, 55’4” proposed
• Minimum Front Yard – 4’ required and 15.5’ south and
16’ east proposed
• Maximum Front Yard – up to 20’ allowed
• Minimum building footprint – 2,000 sq. ft. required;
33,520 sq. ft. proposed
• Max. building footprint – up to 200,000 sq. ft. allowed
• Side Yard setback – 4’ required, 10.3’ proposed on north
• Rear Yard setback – 5’ required, about 350’ proposed
• Bike parking – Long term – in compliance with UDO
and 1/3 of required spaces shall be covered – 75 spaces
required and 80 proposed (40 through Bike Garage and
40 through individual garages)
• Parking – 1 space per unit (94 units) – 94 spaces
required, 151 spaces proposed (131 surface and 20
garage)
• Architectural requirements –
o Building must have a base, middle and top
o Permitted materials – brick, fiber cement
siding, stone, glass, storefront, metal and
metal panels
o Variety of building materials and design
elements to create a pedestrian scale
o Secondary facades finished in colors
compatible with the colors of the Primary
Façade
o Building entrances defined
o Rooftop equipment screened
o Fiber cement not installed between ground
and bottom of first floor windows
o All upper level units have balcony
• Lighting complies with footcandle
requirements and is of uniform design
• Signage complies with UDO
• Trash enclosure compatible with the principal
building
PUD Standards NOT MET; therefore, variance must be requested or adjustments made:
1. Section 6.4. – Adjacent/adjoining parking lots shall be interconnected either by alley or internal driveway. No
vehicular connection to the north provided.
2. Bike parking – Short Term – In compliance with UDO – 0.1 space per bedroom required, 150 bedrooms
proposed, 15 spaces required, 10 spaces provided
2
Site Plan and Parking:
The proposed apartment building is very similar to what was shown in the PUD concept plan. It is a large (slightly
modified) L Shape structure pulled up to the corner of Fairfax Manor Drive and Old Meridian Street. Parking is tucked
behind the building with 131 surface parking spaces and 20 first floor garage spaces, that can be rented by the residents.
On-street parking is also existing/provided along both streets. There are 6 spaces directly in front of the apartment
building on Fairfax Manor Drive and 12 spaces in front of the future townhomes. There are 20 spaces along Old Meridian
Street. Vehicular access will be primarily from Fairfax Manor Drive. A secondary access point to Grand Vue Drive is
provided at the far west end of the property, behind the future townhomes proposed to the west. (Grand Vue Drive
connects to Main Street and is lined with townhomes.)
The site plan also shows where 14 townhomes are proposed to complete the streetscape of Fairfax Manor Drive. These are
intended to follow the development pattern of the other townhomes in Grand & Main. They will have garages accessed
from the rear (north) and front doors opening onto Fairfax Manor Drive. The design of these townhomes has not yet been
completed but will return to the Plan Commission for approval at a later date.
The dumpster enclosure is provided in the middle of the site, at the end of the driveway into the parking area from Fairfax
Manor Drive. This will be a large compactor and enclosed in a brick surround. Staff is working with the Petitioner to
enhance the architectural design of this enclosure, as it will be a main view as one enters the site. The Petitioner is
open to improving this by providing additional brick detailing or height to the structure.
Vehicular Connection to The Olivia development:
When The District PUD was originally brought before the Plan Commission in October of 2013, The Olivia was not yet
submitted as a project. Staff worked with the Developer, Edward Rose, at that time and said a vehicular connection
between this site and that site (to the north) would be required per the Old Meridian District masterplan. The Developer
agreed to show the connection on their Concept Plan and wrote a requirement for connectivity into their PUD (Section
6.4).
When The Olivia project came through a few months later, that Developer, Keystone Group, was told the same thing –
that a connection to the south (the District) is required. At that time, this parcel was not fully planned yet, and Keystone
Group did not want to put in a connection that didn’t work with the future development on the District side. Keystone
Group committed to providing a vehicular connection point, location to be determined and agreed upon with Edward
Rose, and had it recorded at with Hamilton County on October 27, 2014. The commitment states they will work with the
landowner to the south upon approval of a Development Plan for the south adjoining parcel. That time is now, and there is
hesitation to comply with their commitment.
A vehicular connection will provide for cross-site access and inter-connectivity, similar to the Michigan Road Overlay
Zone and other districts. It will be helpful in allowing residents, delivery services, and trash trucks to safely and
conveniently travel between properties rather than have to go back out onto Old Meridian Street. Staff is continuing to
work with both parties to find a location for a vehicular connection that will benefit everyone.
Engineering:
Detention and water quality for this project is handled through the large pond to the south of this proposed building. The
large pond was master planned for the entire Grand & Main project. The Petitioner will continue to work with the
Engineering Dept. through construction plans approval phases.
Active Transportation:
This development will provide the missing pieces of the Grand and Main project pedestrian network. 5’ wide sidewalks
will be provided along Fairfax Manor Drive to connect to existing sidewalks. A10’ wide concrete sidewalk will be
provided across this frontage along Old Meridian Street. The site plan currently shows a 16’ gap between the edge of
the sidewalk and the vehicular entry to Olivia. Petitioner, this connection must be made. Please revise plans to
complete this sidewalk.
First floor units will have sidewalks connecting them to the sidewalks along Old Meridian Street and Fairfax Manor
Drive. A sidewalk will be provided from the rear entry of the building across the parking lot to connect to the Olivia site
to the north. When the Olivia was built, the developer installed a sidewalk connection up to their south property line. This
pedestrian connection will now be completed, providing an alternative way to reach Main Street. Staff would like the
Petitioner to make this connection a fully protected sidewalk, by adjusting where the landscaping is placed in order to
3
have landscaping on both sides of the sidewalk.
Exterior bike parking (5 racks/10 spaces) is provided on the southeast side of the building. It is adjacent to the sidewalk
along Old Meridian Street and near the main pedestrian entry at the southwest corner of the building. 5 additional short-
term bicycle parking spaces are needed to comply with the UDO. A bike garage with room for 40 bikes is provided at
the northwest corner of the building. This garage space will also have a bike repair stand for residents to work on their
bike if needed. Residents can also utilize their garages on the first floor to store their bikes.
Architectural Design:
Avant Phase II is designed to complement the existing Avant apartment building to the south. It will not be an exact
match but will have similar features and design style (guided by PUD requirements). It will have many of the same
materials, including the use of oversized masonry units, brick, fiber cement siding/panels, metal panels, and metal wire
mesh for the balconies. Similar to Phase I, the ends of the buildings will have focal elements with the larger mixed red
fiber cement panels. Balconies or outdoor spaces will be provided for all the units.
The oversized masonry units will range from the first floor up to the third floor, depending on which side of the building
one is looking at. The PUD requires masonry materials as a base and does not allow for fiber cement to go all the way to
the ground. Off white and dark gray colored fiber cement panels will be used on the fourth floor on all sides and in the
rear on the second through fourth floors. The red fiber cement siding will be used at focal points of the building, primarily
the corners. Staff would like the Petitioner to examine using additional red fiber cement paneling on the rear (west)
elevation to break up the large amount of white on the façade. There are two single “bays” or “columns” where it
might look appropriate and not overdone.
Lighting:
Site lighting will match Avant Phase I with LED street lights and parking lot lights proposed. Down lights will be
installed along the face of the building under canopies. First floor units will have a sconce light on their patio. No other
building accent lighting is proposed. The photometric plan meets the 0.5 footcandle limit along the property lines.
Landscaping:
Street trees will be provided along Old Meridian Street and Fairfax Manor Drive. Trees will also be installed along the
north property line, which will help to enhance the view between the parking lot of the Olivia and this project. Building
base plantings will be provided around the exterior of the building where there is not communal plaza/patio space. First
floor units will have landscaping at their individual lawn/patio areas similar to Avant Phase I. There will be an outdoor
amenity green space/patio area on the north end of the project. This will include an additional sidewalk to the rear of the
property, outdoor seating area and grass area. The Urban Forester has not yet approved the landscape plan.
Signage:
Three signs are proposed for Avant Phase II. This project is a Residential Complex and is allowed one sign per entrance at
50 sq. ft. per the UDO. All three entrance signs are 48.77 sq. ft. A Spandrel Panel will still need to be identified, and Staff
is working on that with the Petitioner. The south Entrance is proposed to have two signs, similar to the entrance for Avant
Phase I.
DOCS Remaining Comments/Concerns:
1. Enhanced trash enclosure design
2. Vehicular connection to the north needed
3. Pedestrian connection with ADA ramp all the way to The Olivia’s vehicular entrance
4. Adjust sidewalk connection through parking lot to be a fully protected walk
5. 5 additional short term bicycle parking spaces
6. Rear façade – additional color exploration to break up expansive white façade
Recommendation:
The Department of Community Services recommends the Plan Commission sends this item to the Commercial
Committee meeting on Tuesday, September 1, 2020 for further review and discussion.