Loading...
HomeMy WebLinkAboutCCRR-Load-Table-ReportCode Compliance Research Report CCRR-1102 Issue Date: 12-20-2017 Renewal Date: 01-01-2019 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 6 April 2017 SFT-CCRR-OP-40b DIVISION: 06 00 00 - WOOD, PLASTIC, AND COMPOSITES Section: 06 11 13 Engineered Wood Products REPORT HOLDER: Woodtone Specialties Inc. 4175 Crozier Road Armstrong, BC V0E 1B6 Canada www.woodtonespecialties.com REPORT SUBJECT: RealPost™ and AbsolutePost™ 1.0 SCOPE OF EVALUATION 1.1 This Research Report addresses compliance with the following Codes: • 2015 and 2012 International Building Code® (IBC) • 2015 and 2012 International Residential Code® (IRC) NOTE: This report references 2015 Code sections with [2012] Code sections shown in brackets where they differ. 1.2 RealPost and AbsolutePost have been evaluated for the following properties (see Table 1): • Structural 1.3 RealPost and AbsolutePost have been evaluated for the following uses (see Table 1): • Structural wood-based products as alternative to sawn lumber • Columns for load-bearing and non-load-bearing applications 2.0 STATEMENT OF COMPLIANCE RealPost and AbsolutePost comply with the Codes listed in Section 1.1, for the properties stated in Section 1.2, and uses stated in Section 1.3, when installed as described in this report, including the Conditions of Use stated in Section 6. 3.0 DESCRIPTION 3.1 RealPost and Absolute Post: RealPost columns are manufactured from SPF and AbsolutePost from Western red cedar lumber that has been finger-jointed, edge- laminated, and pressed into columns. The columns are offered in nominal sizes of 4 × 4, 6 × 6, and 8 × 8 inches, with actual dimensions, respectively, of 3-1/2 × 3-1/2, 5-1/2 × 5-1/2, and 7-1/4 × 7-1/4 inches. The columns have lengths up to 40 feet. The adhesives used for finger-jointing lumber and laminating of posts conform with ASTM D2559 and ASTM D7247. 4.0 PERFORMANCE CHARACTERISTICS 4.1 Structural Load-Bearing: Columns were tested for compression parallel to the grain. Calculated allowable column loads are based upon ANSI/AWC NDS-2015 National Design Specification (NDS) Chapter 3.6 Compression Members. 5.0 INSTALLATION 5.1 General: RealPost and AbsolutePost must be installed in accordance with the manufacturer’s published installation instructions, the applicable Code, and this Research Report. A copy of the manufacturer’s instructions must be available on the jobsite during installation. 5.2 Application: RealPost and AbsolutePost are intended to be used as light structural columns for load-bearing and non-load-bearing columns in buildings of combustible construction under normal temperature service conditions where the moisture content in use will be a maximum of 19%, regardless of the moisture content at the time of manufacture. Allowable design loads for axial capacity are shown in Tables 2 and 3. Structural load-bearing columns are limited to the sizes and lengths shown in Tables 2 and 3, intended for axial loading only. Non-load-bearing columns may be any size and length manufactured for architectural appearance around structural supports. Code Compliance Research Report CCRR-1102 Page 2 of 5 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 6 April 2017 SFT-CCRR-OP-40b 6.0 CONDITIONS OF USE 6.1 Installation must comply with this Research Report, the manufacturer’s published installation instructions, and the applicable Code. In the event of a conflict, this report governs. 6.2 Allowable loads in Tables 2 and 3 assume untreated application and normal temperature where the moisture content in use will be a maximum of 19%, with factors being 1.00. For other conditions see NDS-2015. No further increases are permitted for other load duration factors. Structural design must be in accordance with Section 4.1 of this report where design loads determined in accordance with the IBC and IRC, as applicable, must not exceed the loads show in Tables 2 and 3. 6.3 RealPost and AbsolutePost are for above ground use. Wet service conditions are beyond the scope of this report. Columns are used only in buildings of Type V-B construction under the IBC, and buildings constructed under the IRC; and for Type III-B construction under the IBC where combustible building elements are allowed. 6.4 Columns are manufactured under a quality control program with inspections by Intertek Testing Services NA, Inc. (AA-647). 7.0 SUPPORTING EVIDENCE 7.1 Reports of tests in accordance with ASTM D5456. 7.2 Data in accordance with the ICC-ES Acceptance Criteria for Structural Wood-Based Products AC47 – June 2017 for Advanced Engineered Lumber. 8.0 IDENTIFICATION Columns are identified with the manufacturer’s name (Woodtone), address and telephone number, the product name (RealPost or AbsolutePost), the Intertek Mark as shown below, and the Code Compliance Research Report number (CCRR-1102). 9.0 OTHER CODES This section is not applicable. 10.0 CODE COMPLIANCE RESEARCH REPORT USE 10.1 Approval of building products and/or materials can only be granted by a building official having legal authority in the specific jurisdiction where approval is sought. 10.2 Code Compliance Research Reports shall not be used in any manner that implies an endorsement of the product by Intertek. 10.3 Reference to the https://bpdirectory.intertek.com is recommended to ascertain the current version and status of this report. This Code Compliance Research Report (“Report”) is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Report. Only the Client is authorized to permit copying or distribution of this Report and then only in its entirety, and the Client shall not use the Report in a misleading manner. Client further agrees and understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of the subject and/or product described herein. This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification and this Report does not represent authorization for the use of any Intertek certification marks. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Code Compliance Research Report CCRR-1102 Page 3 of 5 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 6 April 2017 SFT-CCRR-OP-40b TABLE 1 - PROPERTIES EVALUATED PROPERTY 2015 IBC SECTION1 2015 IRC SECTION1 Compression parallel to the grain 2303.1.10 R502.1.5, R602.1.5, R802.1.4 1 Section numbers may be different for earlier versions of the International codes. TABLE 2 – COLUMN CENTRICAL AXIAL ALLOWABLE LOAD (LBS), NORMAL DURATION (100%)1, 2, 3 Moisture Content 12% Length (ft) SPF Western Red Cedar 4 × 4 6 × 6 8 ×8 4 × 4 6 × 6 8 ×8 4 18016 39999 56386 19509 44171 62288 6 11228 36247 51633 11719 39676 56661 8 6744 30415 44642 6980 32552 48078 10 4409 23063 35044 4553 24167 36888 12 3092 17068 26366 3190 17731 27447 14 2284 12902 20064 2355 13357 20793 16 1755 10031 15646 1809 10366 16181 18 1390 7999 12500 1432 8259 12911 20 1127 6519 10197 1162 6727 10525 22 n/a 5410 8469 n/a 5581 8738 24 n/a 4560 7142 n/a 4703 7366 Moisture Content 15% Length (ft) SPF Western Red Cedar 4 × 4 6 × 6 8 ×8 4 × 4 6 × 6 8 ×8 4 16691 36209 51010 18247 40280 56788 6 10976 33130 47068 11510 36581 52084 8 6692 28591 41633 6935 30910 45288 10 4392 22387 33768 4538 23609 35820 12 3085 16823 25893 3184 17527 27054 14 2280 12795 19860 2352 13267 20622 16 1753 9976 15545 1807 10320 16095 18 1388 7968 12443 1431 8233 12862 20 1126 6500 10162 1161 6710 10496 22 n/a 5398 8446 n/a 5570 8718 24 n/a 4552 7126 n/a 4695 7353 Code Compliance Research Report CCRR-1102 Page 4 of 5 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 6 April 2017 SFT-CCRR-OP-40b TABLE 2 - CONTINUED1, 2, 3 Moisture Content 19% Length (ft) SPF Western Red Cedar 4 × 4 6 × 6 8 ×8 4 × 4 6 × 6 8 ×8 4 14912 31577 44442 16234 34745 48919 6 10544 29177 41360 11089 31965 45362 8 6603 25956 37451 6848 28054 40639 10 4363 21253 31684 4509 22490 33723 12 3072 16398 25074 3171 17116 26259 14 2274 12614 19512 2346 13088 20283 16 1749 9885 15374 1803 10230 15926 18 1386 7917 12348 1429 8182 12768 20 1125 6469 10106 1160 6679 10439 22 n/a 5378 8410 n/a 5550 8682 24 n/a 4538 7102 n/a 4682 7328 1 The cross-sectional areas for the columns are as follows: 4 × 4 = 11.79 in2; 6 × 6 = 23.00 in2; 8 × 8 = 23.94 in2 2 Horizontal loading is not permitted 3Allowable loads assume untreated application and normal temperature service conditions where the moisture content in use will be a maximum of 19%, with factors being 1.00. For other conditions see NDS- 2015. No further increases are permitted for other load duration factors. TABLE 3 – COLUMN ECCENTRICAL AXIAL ALLOWABLE LOAD (LBS), NORMAL DURATION (100%)1, 2, 3 Moisture Content 12% Length (ft) SPF Western Red Cedar 4 × 4 6 × 6 8 ×8 4 × 4 6 × 6 8 ×8 4 9062 19556 28098 9264 20077 28890 6 6696 17288 26090 6804 17684 26804 8 4767 14630 23763 4850 14898 24337 10 3485 11937 21148 3553 12130 21575 12 2637 9658 18376 2693 9821 18680 14 2057 7882 15726 2103 8025 15983 16 1646 6514 13437 1684 6641 13666 18 1345 5455 11538 1377 5568 11746 20 1118 4627 9969 1146 4726 10156 22 n/a 3968 8336 n/a 4056 8551 24 n/a 3436 7082 n/a 3516 7269 Code Compliance Research Report CCRR-1102 Page 5 of 5 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 6 April 2017 SFT-CCRR-OP-40b TABLE 3 - CONTINUED1, 2, 3 Moisture Content 15% Length (ft) SPF Western Red Cedar 4 × 4 6 × 6 8 ×8 4 × 4 6 × 6 8 ×8 4 8814 18836 26969 9062 19469 27936 6 6628 16782 25148 6753 17270 26002 8 4749 14364 23054 4836 14691 23733 10 3479 11831 20672 3547 12050 21198 12 2634 9614 18109 2691 9786 18484 14 2055 7860 15591 2101 8008 15885 16 1644 6501 13371 1683 6630 13614 18 1344 5447 11499 1377 5561 11715 20 1118 4621 9944 1146 4722 10136 22 n/a 3964 8336 n/a 4053 8549 24 n/a 3433 7082 n/a 3514 7267 Moisture Content 19% Length (ft) SPF Western Red Cedar 4 × 4 6 × 6 8 ×8 4 × 4 6 × 6 8 ×8 4 8426 17771 25319 8684 18404 26281 6 6504 16000 23723 6642 16506 24582 8 4718 13906 21939 4807 14270 22651 10 3467 11638 19894 3537 11877 20458 12 2629 9534 17652 2685 9713 18068 14 2052 7821 15359 2098 7971 15668 16 1643 6480 13251 1681 6610 13499 18 1343 5434 11429 1375 5549 11651 20 1117 4613 9902 1145 4713 10096 22 n/a 3958 8336 n/a 4047 8547 24 n/a 3429 7082 n/a 3509 7265 1 The cross-sectional areas for the columns are as follows: 4 × 4 = 11.79 in2; 6 × 6 = 23.00 in2; 8 × 8 = 23.94 in2 2 Horizontal loading is not permitted. End loads are limited to a max. eccentricity of 0.60 in. for 4 × 4 column, 1.06 in. for 6 × 6, and 1.49 in. for 8 × 8 column. 3 Allowable loads assume untreated application and normal temperature service conditions where the moisture content in use will be a maximum of 19%, with factors being 1.00. For other conditions see NDS-2015. No further increases are permitted for other load duration factors.