Loading...
HomeMy WebLinkAboutLEGACY RIDGE 123 - LR123 (AS DESIGNED)Indiana 2�2� Perfarman�e �ompliance Praperty 6757 FELT�N WAY CARMEL, IN 46033 Madel: 35D0 Community: LEGACY RIaGE 123 LEGACY RIDGE 123 LR123 (AS QESIGNEQ} ❑rganixatian TSI Energy Solutions Matthew Timmons 6uilder LENNAR HOMES Ins e�tion 5tatus _ T���nergyS�lutir�ns p Results are projected This report is based an a proposed design and does not confirm field enforcement of design elements. Annual Energy Cost Design Heating Cooling Water Heating Mechanical Ventilatian 5ubTotal - Used to determine �omplian�e Lights & Appliances wlout Ventilation �nsite generation Total 11D5 11 D2.4.12 11 D2.5 11 D2.5 Requirements � � � � � � � � Performance-based compliance passes by 4.5°io Air Leakage Testing Area-weighted average fenestration SHGC Area-weighted a�erage fenestration Ll-Factor 11D4.1 Lighting Equipment Efficiency f�landatory Checklist �'�andatory code requirements that are not checked by Ekotrope must be met. 11D3.6 Mechanical Ventilation Rate 1103.6.1 hlechanical Ventilation Efficacy Indiana 2020 Performance $1,462 $266 $398 $28 $2,154 $943 $0 $3,�97 As aesigned $1,393 $255 $398 $10 $2,D57 $943 $0 $3,D�� Air sealing is 4.00 AGH at 50 Pa. It must not exceed 5.0� ACH at 5a Pa. Design ex�eeds requirements fvr Indiana 202� Perfvrman�e compliance hy 4.5°Io. As a 3rd party extension of the code jurisdi�tion utilizing these reports, I certify that this energy code complian�e document has been created in accordan�e with the requirements of Chapter 4 of the adopted Intemational Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certiTy that the building design des�ribed herein is consistent with the building plans, specifications, and other �al�ulations submitted �tiith the permit application. If rating is Confirmed, I �ertiTy that the address referenced abo�e has been inspected.+tested and that the mandatory pro�isions of the IECC have 6een installed to meet or ex�eed the intent of the IECC or will be verified as such by another party. Name ❑rganizatian Matthew Timmons TSI Energy 5olutions Signature: Date: 6112f2D at 10:57 Af�9 Ekotrope RATER - Vers�on 3.2.3.2458 Indiana 202� Perforinance compliance results calculated using Ekotrope RATER's energ}� and code compliance algorithm, including appropriate amendments. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are 6ased on data entered 6y Ekotrope users. Ekotrope disclaims all lia6ility for the information shown on this report. ���7 F E LT� hl �II�AY Ceiling Attic, R-38 Abawe Grade Walls R-1fi Foundation Walls R-11 Framed Floor R-38 Slab R-�.� Perimeter, R-0.0 Under Ilnfiltration 4 ACH50 Window U-Value: fl.33, SHGC: 0.31 Building Features Duct 5upply R-25.�, Return R-25.Q Duct Leakage ta Outside 4 CFM251 10� ft2 Tatal auct Leakage 8 CFM251 100 ft2 (Past-Canstructiony Heating Furnace • IVatural Gas • 95.5AF1lE Cooling Air Conditianer • Electri� • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3ro party ext�r7sion of tne code junsd�ci�on ut�lizir7g these reports, I cert�fy that ihis energy code can7pliar7ce documeryt has been created in accoraance �aith the requiren�er7ts of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent �tiith the building plans. specifications, and other calculations submitted with the permit application. If rating is Confrmed: I certiTy that the address referenced above has been inspected.+tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent ofthe IEGC or vrill be verifed as such by another party. Name: Matthew Timmans Signature: Organization: TSI Energy Solutior�s Date: 6f1z120 at 1D:57AM o rope - Version 3.2.3.2458 Irdiara 2C2ii Certiicate camr wnce r�s.alts calculated usina Fko=rope �.ATER's energy and code complia�c� �Inari:lim. including aor�opriate ainerdme�ts E4::�tr:��� P..=.TER is a RESNETHcc-edited HFRS R?trg Tool. =.1 resul°s are based on d.=.:._. �n � a: :�: EF:otr:�:� ��s�rs. -E:o�r��:e : a=1a -is all lial: :.: i� t a in-c ma:ic� a�o::n o� 1� a r=��c �. CARM E L, 1 N 4G�33 Builder: LENNAR HDMES Madel: 35�U Community: LEGACY RIDGE 123 This repart is based an a propased design and does nat confirm field enfar�ement �f design elements. Energy �ode Inspectian Checklist Praperty 6757 FELT�N WAY CARMEL, IN 46033 Madel: 35D0 Community: LEGACY RIaGE 123 ❑rganixatian TSI Energy Solutions Matthew Timmons 6uilder LENNAR HOMES LEGACY RIDGE 123 LR123 (AS QESIGNEQ} �eneral Building Infvrmatian Canditioned Area �sq ft} Canditioned Valume (�ubic ft) Insulated Shell Area (sq ft� 5,4�6 48,�a8 9,5D7 Ins e�tion 5tatus _ T���nergyS�lutir�ns p Results are projected The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will �hange in the field frorn what has been modeled. The inspection pro�ess should identify any �hanges and ensure that the home cantinues to meet the applicable energy code. 51ab � Name: BSMT�1,712 s.f., 174 ft. exterior perimetery R-0 perimeter insulation, R-� under slab insulatian. Framed Flvar � Name: DUER GARAGE (428 s.f.} R-0 continuous insulation, R-38 cavity insulation Insulatian Grade: I � Name: DUERAMBIENT (14 s.f.} R-0 continuous insulation, R-38 cavity insulatian Insulation Grade: I Fvundatian Wall � Name: C�NDlAM6 �Exterior Perimeter [ft]: 131, HeightAbave Grade [ft]: 1, aepth Below Grade [ft]: 8} R-11 continuous insulation, R-0 cavity insulation Insulation Grade: I Feet from top af wall to tap of insulation: 0, Feet from top of wall to bottam of insulation: 4 � Name: C�NDlGAR �Exterior Perimeter [ft]: �3, Height Above Grade [ft]: 1, Depth 6elow Grade [ft]: 8} R-11 cantinuous insulation, R-0 cavity insulation Insulation Grade: I Feet from tap af wall to tap of insulatian: 0, Feet from top of wall to bottom of insulatian: 4 Above �rade Wall Energy �ode Inspectian Checklist Property ❑rganixatian 6757 FELT�N WAY TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Madel: 35D0 Community: LEGACY RIaGE 123 6uilder LENNAR HOMES LEGACY RIDGE 123 LR123 (AS QESIGNEQ} � Name: C�NDlAM6 �2,387 s.f.} R-3 continuous insulation, R-13 cavity insulatian Insulation Grade: I � Name: CaNDlAMB 2?C6 �27D s.f.} R-3 continuous insulation, R-19 cavity insulatian Insulation Grade: I � Name: C�NDlGAR �387 s.f.} R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I � Name: C�NDlATTIC �218 s.f.} R-3 continuous insulati�n, R-13 cavity insulatian Insulation Grade: I Rim Jaist � Name: C�N DlAM 6�27D s.f. y R: 13.575 � Name: C�NDlGAR �43 s.f.y R: 1 D.876 � Name: CaNDlATTIC �58 s.f.� R: 1 D.876 �eiling 1 Raof � Name: SECONa (2,1�4 s.f.] R-27.�5 continuaus insulation, R-1 D.15 �avity insulation Insulati�n Grade: I apaque Dvar � Name: FR�NT (20 s.f.} U: 0.182 � Name: GARAGE (18 s.f.} U: 0.182 Ins e�tion 5tatus _ T���nergyS�lutir�ns p Results are projected 2 Energy �ode Inspectian Checklist Property ❑rganixatian 6757 FELT�N WAY TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Madel: 35D0 Community: LEGACY RIaGE 123 6uilder LENNAR HOMES LEGACY RIDGE 123 LR123 (AS QESIGNEQ} �lazing Inspe�tion 5tatus Results are projected � Name: FR�NT (127 s.f.}, U: 0.330, SHGC: 0.31, Drientation: SOUTH_EAST � Name: BAGK (ii4 s.f.}, Ll: D.33D, SHGC: 0.31, Drientation: NORTH_WEST � Name: BAGK 2X6 �i7 s.f.}, Ll: D.33D, SHGC: 0.31, �rientation: NORTH_WEST � Name: BAGK 2X6 Ga (18 s.f.}, U: 0.330, SHGG: 0.31, Orientation: NDRTH_1NEST � Name: RIGHT 51�E �83 s.f.}, lJ: 0.330, SHGC: 0.31, ❑rientation: N�RTH_EAST � !�! � Name: RIGHT SI�E 65MT �16 s.f.�, lJ: a.33a, SHGC: 0.31, ❑rientation: N�RTH_EAST Name: LEFT SIaE �59 s.f.�, Ll: 0.33D, SHGC: D.31, Drientation: SDLITH_WEST Name: LEFT BSMT (16 s.f.), U: 0.330, SHGC: 0.31, �rientation: SDUTH_WEST 5kylight Nane Present Me�hanical Ventilativn � Mechanical ventilation system rated for, and capable of, providing cantinuous �entilation. System shall include automatic timing controls. System type: Exhaust �nly, 24 hrslday, 12 UVatts Mechanical Equiprnent � Fuel-fired air distribution {1} • Natural Gas • 10D°/o Heating Laad @ 95.5AFUE � Air conditioner (2} • Electric • 1 DD°Io Caoling Load [�7a 13 SEER � Water Heating �3} • Electric • 100°Io Hot lNater Laad a� 0.93 Energy Factor + TS��nergyS�lutir�ns 3 Energy �ode Inspectian Checklist Praperty 6757 FELT�N WAY CARMEL, IN 46033 Madel: 35D0 Community: LEGACY RIaGE 123 ❑rganixatian TSI Energy Solutions Matthew Timmons 6uilder LENNAR HOMES LEGACY RIDGE 123 LR123 (AS QESIGNEa} Air Leakage Cvntrvl Ins e�tion 5tatus _ T���nergyS�lutir�ns p Results are projected � Test Status: 6lower-door tested House is air-sealed as to achieve 3,227 CFM�O �4.00 AGH50] or less at final blower-door test. Infiltration Requirements for IECC in Climate Zone 5 2a09 IECC Infiltration limit for the design hame is 7 ACHS�. 2a12 IECC Infiltration limit for the design hame is 3 ACHS�. 2a15 IECC Infiltration limit for the design hame is 3 ACHS�. 2�18 IECC Infiltration limit for the design home is 3 ACH��. Duct Leakage Duct 5ystem 1 NOT entirely within ��nditioned spa�e, testing required Leakage to ❑utside specified as: � CFM251 1 DD ftz Total Leakage spe�ified as: 8 CFM251 1D� ft2 �Post-Constru�tion} Duct Leakage Cvde Requirements fvr IECC 2009 IECC: Postconstruction Leakage Test: auct Leakage ta Dutdaars �= 8 CFM251 100 sq ft CFR. Rough in Test with AHLl: Total auct Leakage �= 6 CFM251 100 sq ft CFA. Rough in Test without AHU: Tatal Duct Leakage �= 4 CFM25 ! 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstructian Leakage Test: Tatal au�t Leaka�e �= 4 CFM25 J 100 sq ft CFA. Rough in Test with AHU: Tatal auct Leakage �= 4 CFM25 I 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage r= 3 CFM25 ! 100 sq ft CFA. 2015 Performance Path �Cost Campliance}: Leakage testing is required UNLESS all ducts and air handlers are lo�ated entirely within the thermal envelope. There is no passlfail threshold for duct leakage on the performance path. Project Notes 4 Building 5ummary Property G757 FELTON WAY CARI,�EL. IN 45033 h9odel: 3500 Communitv: LEGACY RIDGE 123 LEGACY RI�GE 123 LR123 �AS aESIGNE�} General Building Informatian Number Of Bedrooms Number Df Floors Conditioned FlaorArea [sq. ft.] Has Ele�tric VehiGe Ready 5pa�e Unconditioned; atta�hed garage7 Canditioned Volume [�u. ft.] Total Units in Building Residence Type Flaar Number �vladel Cammunity Climate Zone Foundatian Wall Name CaND.�Ah46 C�M D.'GAR Qrganixation Inspectian Status TSI Energy Solutions Results are proje�ted I,�atthew Timmons Builder LENNAR HDf•;1E5 4 2 5,44�i ND Yes 48;408 1 5ingle family detached 35�0 LEGAGY RIDGE 123 5A r TSICner�,�S�l�atir�ns Liqrary Type Height Aba�e Grade Depth Below Grade R-11 Drapetl, 4f[ 1 8 R-11 Draped, 4f[ 1 8 Perimeter 131 43 Foundatian Wall Lihrary List Name Feet From Wall Top To Feat From Wall Top To Is Fully Insulated Continuous R-value Cantinuauslnsulation Continuauslnsulation Top Battam R-11 Draped, 4R p 4 No 11.0� Slab Name Library Type BSh�1T Llninsulated Locatian Enclosing Exposed Exterior Conditioned Space Exposed Exterior Conditioned Space Ca�ity R-value Effective Insulation R• value N.'A N.+A Perimeter FloorGrade CarpetR Exposed SurtaceArea Location Enclosing Masonry Area 174 Below Grade D � 1,712.D f[� Exposed Exterior Conditioned Space Slab Lihrary List Name Wall Construction Slah Completel�r UnderslaG Perimeter Perimeter Thermal Break Effective R-value rype Insulated. Insulation Width [Yt] Insulation Depth [fi] �nsu�ation R Value Uninsulated �,Nood Frame ? Dther fVo 0 0 D No 6.00 � Building 5ummary Property Qrgan ixation G757 FELTON WAY TSI Energy Solutians CARI,�EL. IN 45033 I,�atthewTimmons h9odel: 3500 Communitv: LEGACY RIDGE 123 Builder LENNAR HDf•;1E5 LEGACY RI�GE 123 LR123 �AS aESIGNE�} Framed Flvar Name Liqrary Type Carpet R OUERAh�61ENT R-38. GRi 1.23 DVER GARAGE R-38. GR1 1.23 Framed Flvar Library List Name R-38. GR1 Rim Joist Name CaN D.`Af•;16 CD N D.� ATTI C C�M D'GAR Rim J�ist Library List Name G1 R-13. DS6 G1 R-13. R-3.0 Wall Name CaN D.'AF;16 CaND.+AP:16 2X6 Effective R•value 33.825 Lihrary rype G1 R-13. R-3.0 G1 R-13. DS6 G1 R-13. �S6 Effective Insulation R-value 1 �. 876 13. 575 Library Type G 1 R-13 BATT. R-3.0 G1 R-19. R-3.D 27C6 Inspectian Status Results are proje�ted Floor Grade Above Grade Above Grade SurtaceArea 270. � ft� 58. � ft� 43.0 ft� Surface Colar h�ledium F�ledium r TSICner�,�S�l�atir�ns Surface Area Location 14.D ft� Exposed Exterior a2a.o n= Llnconditioned, attached garage Locatian Exposed Exterior Unconditioned. atta�hed garage Unconditioned. atta�hed garage Surtace Area 2.387.D fI� ��a.o n= Location Exposed Exterior Exposed Exterior � Building 5ummary Property G757 FELTON WAY CARI,�EL. IN 45033 h9odel: 3500 Communitv: LEGACY RIDGE 123 LEGACY RI�GE 123 LR123 �AS aESIGNE�} Qrgan ixation TSI Energy Solutians I,�atthew Timmons Builder LENNAR HDf•;1E5 Name Library Type CDND.'ATTIC G1 R-13 BATT. R-3.0 CaND.'GAR G1 R-13Gar4^Jalls Wa�ll Library List Name Effective R-value G1 R-13 6ATT. R-3.0 15.12 G1 R-13 GarVdalls 11.141 G1 R-19. R-3.02X6 20217 Inspectian Status Results are proje�ted 5urtace Colar F�ledium F�ledium r TSICner�,�S�l�atir�ns Surtace Area Lacation 218. D f[� Atti� 387.D f[� Unconditioned. attached garage Glazing Name Library Type Wall Assignment Foundation Wall 4varhang Depth Dverhang Ft To Oyerhang Ft To Orientation SurfaceArea Assignment Top Bottom BRCK LI-.33. SHGC-.31 COND.+AP;1B D � 0 Narthwest 174.� ft� BACK 2X6 11-.33. SHGC-.31 CDNa+AF�1B 27C6 D � 0 Narthwest 77.� ft� BACK 2X6 GD lJ-.33. SHGC-.31 CONa+AI,�B 27C6 D 0 0 Narthwest 18.0 ft� FRDNT lJ-.33. SHGC-.31 COND.+AF;1B D � 0 Southeast iz�.o n= LEFT BSf�1T lJ-.33. SHGC-.31 CDNQ+Ah�1B D � 0 Southt��est 16.� ft� LEFT SI�E 11-.33. SHGC-.31 COND.+AI;1B D � 0 Southwest 59.� ft� RIGHT SI�E 11-.33. SHGC-.31 COND.+AP;1B D � 0 Nor[heast 83.� ft� RIGHT SIDE BSP�1T 11-.33. SHGC-.31 CDNa+AI�1B D � 0 Nor[heast 16.� ft� Glazing Library List � � Name Shgc U-factor lJ-.33. SHGC-.31 D.31 �.330 � Building 5ummary Property G757 FELTON WAY CARI,�EL. IN 45033 h9odel: 3500 Communitv: LEGACY RIDGE 123 LEGACY RI�GE 123 LR123 �AS aESIGNE�} Skylight Skylight Library List Qrgan ixation TSI Energy Solutians I,�atthew Timmons Builder LENNAR HDf•;1E5 None Present None Present ❑paque Davr Name Library Type Wall Assignment Foundation Wall Assignment FRDNT Fiberglass+'Steel COND.+AP;1B Door GARAGE Fiberglass+'Steel COND.+GAR Door ❑paque Davr Library List Name Fiberglass.+Steel Door Ravf Insulatian Name SECOND Effective L!-factor 0.182 Inspectian Status ' TS��ner�,�S�l�atir�ns Results are proje�ted Emittance Solar SurtaceColor SurtaceArea Location Ahsorptance 0.9 0.75 P;ledium 20.6 ft� Exposed Exterior 0.9 0.75 1;ledium 18.6 ft� Exposed Exterior Liqrary Type Attic ExteriorArea [s.f.] Clay or Concrete Raof Tiles R-38 Blo�ti�n. GR1 2.154 No Surtace Color F;ledium Rovf Insulati�n Lihrary List � Name Has Radiant Barrier Effective R-value R-38 Blown. GR1 Na 38.268 Surface Area 2.154. � f[� Location Atti� � Building 5ummary Property G757 FELTON WAY CARI,�EL. IN 45033 h9odel: 3500 Communitv: LEGACY RIDGE 123 LEGACY RI�GE 123 LR123 �AS aESIGNE�} I Whale House Infiltrativn Infiltration 4 ACH at 50 Pa Qrgan ixation TSI Energy Solutians I,�atthew Timmons Builder LENNAR HDf•;1E5 Measurement rype Blower-door tested Inspectian Status Results are proje�ted Shelter Class 4 r TSICner�,�S�l�atir�ns Mechanical Ventifation * Ventilation Type Ventilatian Rate [ft� f Dperational hours per day Fan Watts Runs once every three Energy Recovery Percent Minute] hours Exhaust �nly 91.96 CFI,� {unmeasured} 24 12 U"Jatts Yes 0 Lighting °4 Interior Fluorescent =5 Interior LED Lighting i Exterior Fluorescent l Exterior LEO Lighting °� Garage Fluorescent =�� Garage LED Lighting Lighting Lighting Lighting 0 1 D� D 10 � 0 1 il0 ❑nsite Generation None Present ❑nsite Generation Library List None Present Solar Generativn None Present Solar Generativn Library List None Present � Building 5ummary Property G757 FELTON WAY CARI,�EL. IN 45033 h9odel: 3500 Communitv: LEGACY RIDGE 123 LEGACY RI�GE 123 LR123 �AS aESIGNE�} C�nditivning Equipment Name Liqrary Type Air conditioner (21 CA13NA036 Fuel-fired air 9155A48�86517 distribution {11 �M1later Heating [31 ENT 50 1 D� Qrganixation Inspectian Status r TSICner�,�S�l�atir�ns TSI Energy Solutions Results are proje�ted I,�atthew Timmons Builder LENNAR HDf•;1E5 Heating Percent Load Cooling Percent Load Hot Water Percent Load Location 04n 100°n 0°a 1 DO°I Qo� 0% �°o �91� 1 � D°io Conditioned Space Conditioned Space Conditioned Space �Equiprnent Type: 915SA4808�517 Fuel Ty;�e fVa�ural Gas �Distri�utian Type Farced Air MatorType PSG {Single Speed} Heating Efficiency 95.5AFUE Heating Capacity [kBtu.�h] 78 Use default EAE No EAE [kWh] 946 Equiprnent Type: CA13NAa3fi Fuel Tyae Electric Distri�utian Type Farced Air MatorType PSG {Single Speed} Caaling Efficien�y 13 SEER Cooling Capa�ity jkBtu.�h] 342 Equiprnent Type: ENT 5a 1fl� Fuel Ty;�e Distributian Type Hot Water Efficien�y Tank Capacity {gal.} Hot Water Capa�ity [kBtu,'h] Recavery Efficiency Eiectric Hydranic Delivery {Radiant] 0.93 Energy Factor 5� 15.4 0.98 � Building 5ummary Property G757 FELTON WAY CARI,�EL. IN 45033 h9odel: 3500 Communitv: LEGACY RIDGE 123 LEGACY RI�GE 123 LR123 �AS aESIGNE�} Distributian 5ystem Distri�utian Type Heating Equipment Caaling Equipment Sq. Feet Served # Return Grilles Supply Duct R Value Return Duct R Value Supply DuctArea [ftz] Return �uct Area [ftZ] Leakage ta Outdaars TotalLeakage Total Leakage Duct Test Conditions Use Default Flaw Rate Duct 1 Duct Lacation Percent 5upply Rrea Percent ReturnArea Duct 2 Duct Lacation Percent 5upply Rrea Percent ReturnArea Duct 3 Duct Lacation Percent 5upply Rrea Percent ReturnArea Duct 4 Duct Lacation Percent 5upply Rrea Percent ReturnArea Duct 5 Duct Lacation Percent 5upply Rrea Percent ReturnArea Duct 6 Duct Lacation Percent 5upply Rrea Percent ReturnArea Ceiling Fan Has Ceiling Fan Cfm Per Wari Qrganixation Inspectian Status TSI Energy Solutions Results are proje�ted I,�atthew Timmons Builder LENNAR HDf•;1E5 Farced Air Fuel-fired air distributian [1] Air canditioner {2j 5446 4 25 25 1470.42 14892 4 CFIv125 � 10� ftZ 435.�i8 CFf4125 Post-Canstruction Yes Conditianed 5pace �4 sa Attic {well vented; under insulation} 40 4L3 Conditianed Space 0 ❑ Conditianed 5pace 0 4 Conditianed 5pace 0 ❑ Conditianed 5pace 4 0 No �oo r TSICner�,�S�l�atir�ns Building 5ummary Property G757 FELTON WAY CARI,�EL. IN 45033 h9odel: 3500 Communitv: LEGACY RIDGE 123 LEGACY RI�GE 123 LR123 �AS aESIGNE�} Water ❑istrihutivn Qrganixation Inspectian Status TSI Energy Solutions Results are proje�ted I,�atthew Timmons Builder LENNAR HDf•;1E5 Water Fixture Type 5tandard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 1�� At Least R3 Pipe Insulatian? No Hot Water Recirculation System7 No Recirculation System Pipe Loop Length [ft] 3� Drain Water Heat Recovery7 No Clvthes Dryer Fuel Ty;�e Cef Field Utilization �s Outside Conditianed 5pace Clothes DryerAvailable Electric Timer Contrals No Yes Clvthes Washer La��el E: i�: �y .3ati: ��: Electric Rate Annual Gas Cost Gas Rate Capacity Imef Is Outside Conditianed 5pace Clothes WasherAvailable ?��4 k'��rh Year 5�7.68; kWh 523.0� 5�.58rTherm 2.874 0.33052632 ND Yes Appliances and Contrals Prooramr�a�le thermastat? Dishwasher �ize Dishwasher Efficiency Dishwasher Outside Canditioned 5pa�e7 Range'Duen Fuel Canvectian Dven7 Inductian Range7 Range'Dven flutside Gonditioned Space7 Refrigeratar Gonsumption Refrigeratar Outside Conditianed 5pace7 Yes 27� kWh ND EI ectric No No ND 7�9 kWhr'Year ND N�tes r TSICner�,�S�l�atir�ns