Loading...
HomeMy WebLinkAboutJG 288 - 2nd floor ewp layoutrequired for cantilever.BCI joist blocking 23/32" min. plywood/OSB into each flange. Nail with 8d nails or rimboard closure. ® F05 See Boise literature for Nail Boise Rimboard nail into each flange. to BCI joist with 8d Bo ise R i mboa r d vertical load capacity. ® F07 vertical load capacity.See Boise literature forF07-A of Boise joist & rimboard for total vertical load capacity. Sum vertical load capacities F07-C (stacked over wall below) Load bearing wall above See Boise literature for vertical load capacity. BCI Joist Blocking® F06 above to bearing below. Solid block all posts from F08 required for cantilever.BCI / AJS joist blocking LVL Rim 8d nails @ 6" o.c. ® Inverted hanger F05-A against top flange with 1/8" Boise Rim Board Web Stiffener for 14" & 16" joists. 5 - 3" (10d) nails gap between bottom flange 1/8" Stiffeners are required on both sides - Hangers with side nailing. - Any hanger with sides not containing the top flange with 3 - 3" (10d) - Web stiffener nailed of the joist. 11 7/8" joists, and nails for 9 1/2" and of the web when : Point Load from above > 1500 lbs. (Factored) Install web stiffeners tight For Point Load from above: F16-E 2x block (stacked over wall below) 1/16" Load bearing wall aboveF09 10-10d nails. Nail with Filler block. Install tight to top flange. mount hanger load exceeds 250 lbs. Backer block required where top Backer block (12" wide min.) Nail with 10- 10d nails. Install tight to top flange. Joist hanger F10 (see literature)Filler Block Contact Boise EWP Engineering for specific conditions. Connection valid for all applications. Nailing 12" OCWeb-Filler Connection Double BCI Joist®F58 Start Framing Here 16" O.C Spacing Connector Summary PlotID Qty Manuf Product Flange H1 2USP SKH1720LNone H2 1 USP SKH1720LReverse H3 2USP SKH1720R None H4 30 USP THF17140 None H5 1 NA N/A None H7 2 HUS 179None H8 24 IHF1714 None H9 3 IHF3514 None H10 3 SKH1720LNone H11 2 SKH1720R None Products PlotID Length Product Plies Net Qty Fab Type FJ1 42' 0" 14" BCI® 4500s-1.8 1 13 MFD FJ2-2 42' 0" 14" BCI® 4500s-1.8 2 4 MFD FJ3 28' 0" 14" BCI® 4500s-1.8 1 1 MFD FJ4 24' 0" 14" BCI® 4500s-1.8 1 4 MFD FJ5 22' 0" 14" BCI® 4500s-1.8 1 1 MFD FJ6 20' 0" 14" BCI® 4500s-1.8 1 6 MFD FJ7-3 20' 0" 14" BCI® 4500s-1.8 3 3 MFD FJ8 18' 0" 14" BCI® 4500s-1.8 1 1 MFD FJ16 16' 0" 14" BCI® 4500s-1.8 1 1 MFD FJ9 12' 0" 14" BCI® 4500s-1.8 1 4 MFD FJ10 8' 0" 14" BCI® 4500s-1.8 1 7 MFD FJ11 6' 0" 14" BCI® 4500s-1.8 1 2 MFD FJ15 6' 0" 14" BCI® 4500s-1.8 1 1 MFD FJ12 4' 0" 14" BCI® 4500s-1.8 1 19 MFD FJ13 2' 0" 14" BCI® 4500s-1.8 1 3 MFD FJ14 28' 0" 14" AJS® 24 1 1 MFD FJ15 22' 0" 14" AJS® 24 1 1 FF FJ15 22' 0" 14" AJS® 24 1 4 MFD BM-42 4' 0" 14" BCI® 4500s-1.8 1 1 FF BM-43 4' 0" 14" BCI® 4500s-1.8 1 1 FF BM-4 14' 0" 1-3/4" x 9-1/4" VERSA-LAM® 2.0 3100 SP 2 2 FF BM-29 10' 0" 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 2 2 FF BM-23 22' 0" 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 2 2 FF BM-25 22' 0" 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 2 2 FF BM-12 12' 0" 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 2 2 FF BM-6 12' 0" 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 2 2 FF BM-18 8' 0" 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 1 1 FF BM-28 8' 0" 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 1 1 FF BM-16 8' 0" 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 2 2 FF BM-13 6' 0" 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 1 1 FF BM-19 6' 0" 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 1 1 FF BM-20 6' 0" 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 1 1 FF BM-7 32' 0" 1-3/4" x 16" VERSA-LAM® 2.0 3100 SP 2 2 FF BM-17 10' 0" 1-3/4" x 16" VERSA-LAM® 2.0 3100 SP 2 2 FF BM-33 10' 0" 2x12 SP No.1 1 1 FF BM-35 10' 0" 2x12 SP No.1 1 1 FF BM-36 10' 0" 2x12 SP No.1 1 1 FF BM-38 10' 0" 2x12 SP No.1 1 1 FF BM-40 10' 0" 2x12 SP No.1 1 1 FF BM-37 10' 0" 2x12 SP No.1 2 2 FF BM-39 7' 0" 2x12 SP No.1 1 1 FF Girder by other 34' 0" 3 1/2" x 1' 0" Generic Material 1 1 FF 2x by other 10' 0" 3 1/2" x 1' 0" Generic Material 1 3 FF Ca1 12' 0" 1" x 14" BC RIM BOARD OSB 1 11 FF Ca2 12' 0" 1" x 14" BC RIM BOARD OSB 1 2 FF Ca3 12' 0" 1" x 14" BC RIM BOARD OSB 1 2 FF Ca4 12' 0" 1" x 14" BC RIM BOARD OSB 1 2 FF Bk1 2' 0" 14" BCI® 4500s-1.8 1 18 FF Bk2 2' 0" 14" BCI® 4500s-1.8 1 11 MFD2x by otherBM-4 2x by otherBM-6 BM-7BM-12 BM-13BM-16 BM-17 BM-18 BM-19BM-20BM-23 2x by otherGirder by otherBM-25BM-28 BM-29BM-33BM-35BM-36BM-37BM-38BM-39 BM-40 BM-42 BM-43 Ca4Ca1Ca1Ca1 Ca1Ca1 Ca1Ca1 Ca3Ca2 Bk2Ca1Ca1 Bk2 Ca1 Ca1Ca1H4H4 Bk2Bk2Bk2Bk2Bk2Bk2FJ15FJ11FJ11FJ1FJ7-3FJ3FJ13 FJ13FJ13FJ14FJ15FJ5FJ8FJ12 FJ12FJ16H8 H8 H8 H10H11H10H8 H9 H4 H4FJ15 FJ9 FJ1FJ1 FJ1 FJ10 FJ6 FJ4 FJ2-2 FJ12Bk1 Bk1 Bk1Bk2Bk2Bk2H8 H11 H7H7 H4H1 H3H2 H4 H5 H4 H4 H41X1X 1X1X 1X1X 1' 7"1' 1" By: Date: Scale:1/4"=1' BC FRAMER RIMBOARD IS NOT TO BE CUT. IF A PIECE OF RIMBOARD ENDS BETWEEN TWO JOISTS, BUTT THE NEXT PIECE UP TO IT. Boise I-Joist can be offset up to 3" to avoid vertical plumbing. Joist 3" max C L Joist 3" max C L OJ-AFASTEN ALL2-PLYLVL'S UP TO 11-7/8" WITH 2ROWS OF 16DSINKER NAILS @12" OC STAGGERED FASTEN ALL2-PLYLVL'S 14"-18" 3ROWS OF 16DSINKER NAILS @12" OC STAGGERED FASTEN ALL2-PLYLVL'S 20"-24" WITH 2ROWS OF 16DSINKER NAILS @12" OC STAGGERED FASTEN ALL3-PLYLVL'S UP TO 11-7/8" WITH 2ROWS OF 16DSINKER NAILS @12" OC STAGGERED, FROM BOTH SIDES FASTEN ALL3-PLYLVL'S 14"-18" 3ROWS OF 16DSINKER NAILS @12" OC STAGGERED, FROM BOTH SIDES FASTEN ALL3-PLYLVL'S 20"-24" WITH 2ROWS OF 16DSINKER NAILS @12" OC STAGGERED, FROM BOTH SIDES FASTEN ALL4-PLYLVL'S UP TO 18" WITH 2ROWS OF 1/2" STAGGEREDTHROUGH BOLTS @12" OC STAGGERED FASTEN ALL4-PLYLVL'S 20"-24" WITH 3ROWS OF 1/2" STAGGEREDTHROUGH BOLTS @12" OC STAGGERED ALL1/2" BOLTS , CAN BE REPLACEDWITH SDW22634SCREWS UNLESS OTHERWISE NOTED ON THE LAYOUT FOR ALLCONNECTION DETAILS Revision Date: Revision Date:2NDFLR FRAMINGCarter Lumber, Franklin INSigma - Hertig08/17/20 Adam Schriner