Loading...
HomeMy WebLinkAboutLiving Room BeamsORIGINAL DESIGN NOTES CONTRACTOR SHALL: VERIFY ALL PLAN DIMENSIONS ARE CORRECT BEFORE CONSTRUCTION AND NOTIFY THE ENGINEER WITH THE CONTACT INFORMATION ON THIS SHEET IN WRITING IF ANY DISCREPANCIES EXIST AND AWAIT THE ENGINEER OR RECORDS DIRECTION BEFORE CONTINUING CONSTRUCTION. DATE:DESCRIPTION: REV: BY: Notes: REVISION:DRAWING NO: PROJECT NO: DRAWN:DATE: CHECKED: TITLE: SCALE AT: CLIENT: SITE: STATUS: DESIGNER: RICHARD CLAYBORN, PE 3 DHS--- Living Room Beam 3040 Rolling Springs Drive Carmel IN 46033 RICHARD W CLAYBORN, PE 6003 FERN VALLEY ROAD LOUISVILLE KY 40228 502-345-4147 Gennifer Grogg 3040 Rolling Springs Drive Carmel IN 46033 Hamilton County, Indiana For Construction LIVING ROOM BEAM DETAIL 2" x10" Perimeter band board Common existing floor joist 8'-2" Approx Estimated Dimension Field Verify6'-5" Existing CMU Wall Original CMU Wall Install 4 new 2" x 6" Columns 2 @ full height adjacent to beam 2@ bottom of beam bearing min 4.5" of beam remove and replace existing 2" x4" column Typical EA End of beam Secure to Exterior 2" x 4" wall entire length Proposed New 48" Width Reversed Staircase from original direction Relocate HVAC Floor Supply as need due to stair rough opening Install new 2" x 10" band board at cut ends Install new load bearing wall Relocate Electrical Install Temporary Falsework under rafters before demo designed by contractor, do not perform work under snow loading Wall to be removed Install 2 EA 1.75" x 18" x 20' LVL Ridge Beams. Contractor to verify span length, plus 9" End bearing to clear span length (4.5" Min End Bearing EA End) before ordering length Place Under Existing Double 2" x 12" Ridge. Secure with Simpson Install 4 new 2" x 6" Columns 2 @ full height adjacent to beam 2@ bottom of beam bearing min 4.5" of beam remove and replace existing 2" x4" columns Typical EA End of beam Secure to Exterior 2" x 4" wall entire length Existing Double 2" x 12" Ridge Board LIVING ROOM BEAM SECTION 4 EA - 2" x 6" with 1EA -12" Plywood Shim Ridge Beam Bottom Brace @ 45 Degree Attach to each common rafter and bottom of beam Trim out beam and bracing with drywall Common studs hidden for clarity Secure top ridge board to bottom ridge beam with simpson straps every 16" on center as well as nails Install Beam Braces @ 45 Degree to Bottom Beam 1/21/2020 12:42:43 AMInstall W 8 x 48 Steel I beam in this span only beneath the load bearing wall from CMU wall to CMU wall. Shim bottom of beam with steel plates such that top of beam is fully supporting plywood floor. Steel Shims beneath W8 x 48 Steel I beam to raise beam Install solid blocking at exterior wall install steel W8 x 48 beam in utility room span Steel Shims beneath W8 x 48 Steel I beam to raise beam Install solid blocking injoist cavity below exterior wall column inset 2" x 6" wall to the exterior wall to allow full depth column bearing on block wall below. Detail shows 2" x 4" wall before removal DESIGN ENGINEER - JANUARY 24, 2020 1" 1-24-2020 RWC RWC 08/18/20 William Hohlt