HomeMy WebLinkAboutStaircase DetailPROPOSED CONSTRUCTION 1. Contractor to verify all dimensions on plan sheet are correct and layout will work. Ensure basement floor finish remains concrete, and upstairs finish floor is same thickness as finish stair material for dimensions to be accurate. Notify engineer immediately if discrepancy is found because this design will no longer be valid. 2. Contractor to verify floor joists are 2" x 10" lumber to ensure dimensions are accurate. Notify engineer immediately if discrepancy is found because this design will no longer be valid. 3. Install 4 stringers constructed from 2" x 12" lumber. Exact length of stringers exceed 16' lumber by 916". Contractor has option of using 18' lumber for exact dimension or placing a 1.25" vertical riser in lieu of 3 4" riser to fully support first tread. 4. Construct load bearing wall along length of staircase to support trimmed floor joists on double top plate. Place 2" x 4" stringer stiffener on side adjacent to framed wall for spacing and to aid finishing. 5. Ensure 5" Minimum of stringer material is left at back of step to uncut edge after stair layout. Do not overcut tread or risers into lumber. 6. Relocate electrical and HVAC as needed. ORIGINAL DESIGN NOTES CONTRACTOR SHALL: VERIFY ALL PLAN DIMENSIONS ARE CORRECT BEFORE CONSTRUCTION AND NOTIFY THE ENGINEER WITH THE CONTACT INFORMATION ON THIS SHEET IN WRITING IF ANY DISCREPANCIES EXIST AND AWAIT THE ENGINEER OR RECORDS DIRECTION BEFORE CONTINUING CONSTRUCTION. DATE:DESCRIPTION: REV: BY: Notes: REVISION:DRAWING NO: PROJECT NO: DRAWN:DATE: CHECKED: TITLE: SCALE AT: CLIENT: SITE: STATUS: DESIGNER: RICHARD CLAYBORN, PE STAIRCASE DETAIL 2 DHS--- Stiarcase Layout 3040 Rolling Springs Drive Carmel IN 46033 RICHARD W CLAYBORN, PE 6003 FERN VALLEY ROAD LOUISVILLE KY 40228 502-345-4147 Gennifer Grogg 3040 Rolling Springs Drive Carmel IN 46033 Hamilton County, Indiana For Construction 4'-0" 11"1'-3 1/2"1'-3 1/2"1'-3 1/2" 3'-10 1/2"4'-0"13'-9 3/4"3/4" 3 1/2" 4'-0"STRINGER STIFFENER 4 EA 48" x 48" Landing Area at bottom of stairs Direction to upstairs Direction to upstairs 2" x 12" x 16' Stringer Spaced Max 18" O.C. 2" x 4" Stringer Stiffener 2" x 4" Stringer Stiffener 2" x 4" Stringer Stiffener 2" x 4" Stringer Stiffener 2" x 12" x 48" Tread Cut to 11" Width 1" x 8" x 48" Riser Trim to 6-7/8" 2" x 4" x 14' Stringer Brace Fastened to adjacent side of framed wall 2" x 4" x 48" Pressure Treated Kickboard anchor in concrete 8'-6 1/4" TOTAL RISE ROUGH FRAMING13'-9 3/4" TOTAL RUN ROUGH FRAMING ADD NOSING FOR FINISHED LENGTH7'-1 3/16"(6'-8" MIN HEADROOM FROM FINISHEDFLOOR TO FINISHED CEILING)13'-9 3/4" MINIMUM FINISHED OPENING LENGTH OF STAIRCASE ADD ONE ADDITIONAL FLOOR JOIST SPAN FOR MINIMUM LENGTH Unit run equal to 11" use construction adhesive and screws Unit rise equal to 6-13/16" use construction adhesive and screws 2" x 12" x 16' Stringer Length Typical EA Stringer Handrail projects up to 3-1/2" into the width of stairs 34" to 38" Handrail height above finished stairs Framed load brearing wall along length of staircase to support floor above without need for a beam Trim existing floor joist to increase stairway width to 48" Rest Floor joists on new 2" x 4" framed stud wall Pressure treated 2" x 4" bottom plate 11 1/4" 6 1 3 / 1 6 "11"14'-11 1/16"3 1/2" 9 1/4"5 5/ 1 6 " 1 1 / 2" 6 7 / 1 6 " 5 7/16" (5" Minimum Req) 1' -0 1/ 8 "10 1/16" 3 3/8"16'-0 9/16" Contractor can use 16'-0" lumber with a 1.25" true board at first stepCOMMON STRINGER 4 EA 15'-1 1/4"14'-11 1/16"3 1/2"1'-0" Max Distancefrom End of Stringer1'-0" Max Distancefrom End of Stringer7'-8" CONTRACTOR TO VERIFY THISCONCRETE TO DRYWALL CEILING DIMENSIONExisting Wall at end of landing, ensure layout provides min 48" from finished nosing to wall before construction. 2" x 4" Stringer Stiffener Nail with 10d (0.128" x 3") nails at 12" on center, staggered, Min 3 4" from each edge, Min 2" from end Typical 1" x 6-1316" x 48" (3 4" Thick) Riser Trim board Typical 2" x 12" x 48" Tread board trimmed to 11"3' -0 " Extend handrail 12" at the bottom of the landing Handrail must continue slope for depth of one tread beyond last riser vertical face Space staircase away from wall sufficient amount to allow column load path to basement Mid span support wall for staircase 6'-9 1/8" 6'-9 1/8"1/20/2020 12:42:23 PMDESIGN ENGINEER - JANUARY 24, 2020 1" 1-24-2020 RWC RWC 08/18/20 William Hohlt