Loading...
HomeMy WebLinkAboutPenn Mark I - AI - BF - 9-12-19Ryan Fireprotection Inc. 9740 E. 148th St. Noblesville, IN 46060 Phone: 800-409-7606 Account Information Facility Name: Penn Mark I Property Type: Not Specified Location Code: IZEBTJN Service Address: 11595 North Meridian Street, Carmel, IN, 46032 Mailing Name: Kevin Fredrick Phone: 317-744-3088 Mailing Address: 11555 North Meridian Street, Carmel, IN, 46032 Assembly Information Type: RPZ Assembly Description: Backflow (Penthouse device) Manufacturer: WILKINS Model: 975XL2 Serial Number: 4291801 Size: 3/4" Type of Service: Domestic Type of Protection: Containment Meter #: Check Valve #1 Initial Test: Pass Fail Held at (PSID): 10.2 Closed Tight Leaked Check Valve #2 Initial Test: Pass Fail Held at (PSID): 10.0 Closed Tight Leaked Differential Pressure Relief Valve Initial Test: Pass Fail Opened at (PSID): 2.7 Did not open Tester Information Comments: The above is certified to be true at the time of testing Service Restored: Yes No Company Name: Ryan Fireprotection Inc. Company Address: 9740 E. 148th St., Noblesville, IN, 46060 Test Gauge: Bill Rumbaugh - Midwest 845-5 (01061633, Last: 9/14/2018, Next: 9/14/2019) Inspected By: Bill Rumbaugh Date of Test: 9/12/2019 Phone #: 800-409-7606 Tester Signature:Certification License: BF97-1197 Form 2015-01 Backflow Page 1 of 1 Ryan Fireprotection Inc. 9740 E. 148th St. Noblesville, IN 46060 Phone: 800-409-7606 Account Information Facility Name: Penn Mark I Property Type: Not Specified Location Code: IZEBTJN Service Address: 11595 North Meridian Street, Carmel, IN, 46032 Mailing Name: Kevin Fredrick Phone: 317-744-3088 Mailing Address: 11555 North Meridian Street, Carmel, IN, 46032 Assembly Information Type: RPZ Assembly Description: Backflow (Domestic #3) Manufacturer: WILKINS Model: 975XL Serial Number: 3249669 Size: 2" Type of Service: Domestic Type of Protection: Containment Meter #: Check Valve #1 Initial Test: Pass Fail Held at (PSID): 6.3 Closed Tight Leaked Check Valve #2 Initial Test: Pass Fail Held at (PSID): 5.7 Closed Tight Leaked Differential Pressure Relief Valve Initial Test: Pass Fail Opened at (PSID): 2.6 Did not open Tester Information Comments: The above is certified to be true at the time of testing Service Restored: Yes No Company Name: Ryan Fireprotection Inc. Company Address: 9740 E. 148th St., Noblesville, IN, 46060 Test Gauge: Bill Rumbaugh - Midwest 845-5 (01061633, Last: 9/14/2018, Next: 9/14/2019) Inspected By: Bill Rumbaugh Date of Test: 9/12/2019 Phone #: 800-409-7606 Tester Signature:Certification License: BF97-1197 Form 2015-01 Backflow Page 1 of 1 Ryan Fireprotection Inc. 9740 E. 148th St. Noblesville, IN 46060 Phone: 800-409-7606 Account Information Facility Name: Penn Mark I Property Type: Not Specified Location Code: IZEBTJN Service Address: 11595 North Meridian Street, Carmel, IN, 46032 Mailing Name: Kevin Fredrick Phone: 317-744-3088 Mailing Address: 11555 North Meridian Street, Carmel, IN, 46032 Assembly Information Type: RPZ Assembly Description: Backflow (Domestic #2) Manufacturer: WILKINS Model: 975XL Serial Number: 3228778 Size: 2" Type of Service: Domestic Type of Protection: Containment Meter #: Check Valve #1 Initial Test: Pass Fail Held at (PSID): 0 Closed Tight Leaked Repairs and Materials Used Final Test CV #1 Final Test: Pass Fail Held at (PSID): 0 Closed Tight Leaked Check Valve #2 Initial Test: Pass Fail Held at (PSID): 0 Closed Tight Leaked Repairs and Materials Used Final Test CV #2 Final Test: Pass Fail Held at (PSID): 0 Closed Tight Leaked Differential Pressure Relief Valve Initial Test: Pass Fail Opened at (PSID): 2.4 Did not open Tester Information Comments: The above is certified to be true at the time of testing Service Restored: Yes No Company Name: Ryan Fireprotection Inc. Company Address: 9740 E. 148th St., Noblesville, IN, 46060 Test Gauge: Bill Rumbaugh - Midwest 845-5 (01061633, Last: 9/14/2018, Next: 9/14/2019) Inspected By: Bill Rumbaugh Date of Test: 9/12/2019 Phone #: 800-409-7606 Tester Signature:Certification License: BF97-1197 Form 2015-01 Backflow Page 1 of 1 Ryan Fireprotection Inc. 9740 E. 148th St. Noblesville, IN 46060 Phone: 800-409-7606 Account Information Facility Name: Penn Mark I Property Type: Not Specified Location Code: IZEBTJN Service Address: 11595 North Meridian Street, Carmel, IN, 46032 Mailing Name: Kevin Fredrick Phone: 317-744-3088 Mailing Address: 11555 North Meridian Street, Carmel, IN, 46032 Assembly Information Type: RPZ Assembly Description: Backflow (Domestic #1) Manufacturer: WILKINS Model: 975XL Serial Number: 3738908 Size: 1 1/2" Type of Service: Irrigation Type of Protection: Containment Meter #: 68825156 Check Valve #1 Initial Test: Pass Fail Held at (PSID): 0 Closed Tight Leaked Repairs and Materials Used Final Test CV #1 Final Test: Pass Fail Held at (PSID): 0 Closed Tight Leaked Check Valve #2 Initial Test: Pass Fail Held at (PSID): 0 Closed Tight Leaked Repairs and Materials Used Final Test CV #2 Final Test: Pass Fail Held at (PSID): 0 Closed Tight Leaked Differential Pressure Relief Valve Initial Test: Pass Fail Opened at (PSID): 3.3 Did not open Tester Information Comments: The above is certified to be true at the time of testing Service Restored: Yes No Company Name: Ryan Fireprotection Inc. Company Address: 9740 E. 148th St., Noblesville, IN, 46060 Test Gauge: Bill Rumbaugh - Midwest 845-5 (01061633, Last: 9/14/2018, Next: 9/14/2019) Inspected By: Bill Rumbaugh Date of Test: 9/12/2019 Phone #: 800-409-7606 Tester Signature:Certification License: BF97-1197 Form 2015-01 Backflow Page 1 of 1 Ryan Fireprotection Inc. 9740 E. 148th St. Noblesville, IN 46060 Phone: 800-409-7606 Account Information Facility Name: Penn Mark I Property Type: Not Specified Location Code: IZEBTJN Service Address: 11595 North Meridian Street, Carmel, IN, 46032 Mailing Name: Kevin Fredrick Phone: 317-744-3088 Mailing Address: 11555 North Meridian Street, Carmel, IN, 46032 Assembly Information Type: DCV Assembly Description: Backflow (Fire System Backflow) Manufacturer: WILKINS Model: 350A Serial Number: U23072 Size: 6" Type of Service: Fire Type of Protection: Containment Meter #: Check Valve #1 Initial Test: Pass Fail Held at (PSID): 0 Closed Tight Leaked Repairs and Materials Used Final Test CV #1 Final Test: Pass Fail Held at (PSID): 0 Closed Tight Leaked Check Valve #2 Initial Test: Pass Fail Held at (PSID): 3.7 Closed Tight Leaked Tester Information Comments: The above is certified to be true at the time of testing Service Restored: Yes No Company Name: Ryan Fireprotection Inc. Company Address: 9740 E. 148th St., Noblesville, IN, 46060 Test Gauge: Bill Rumbaugh - Midwest 845-5 (01061633, Last: 9/14/2018, Next: 9/14/2019) Inspected By: Bill Rumbaugh Date of Test: 9/12/2019 Phone #: 800-409-7606 Tester Signature:Certification License: BF97-1197 Form 2015-01 Backflow Page 1 of 1