Loading...
HomeMy WebLinkAbout01367IN_E6MECHANICAL EQUIPMENT ELECTRICAL CONNECTION SCHEDULE ITEM E�UIPMENT CHARACTERISTICS DISLbNNECT SNITCH DESCRIPTION CIRCUIT FEEDER REMARNS N�� VOLTS PH MG� SIZE PL FUSE FEATURES 1� CU-1 208 1 12 C-D,29 2�12 & 1�12G - 3�4" C. 30 2 15 3R COMPLETE CONNECTION BETWEEN INDOOR AND OUTDOOR UNIT. SEAL, CORE AN� RRE CAULK OCU-2 208 1 12 C-J1,bS 2�12 & 1�f12G - 3/4° C. 30 2 �5 3R PENETRATIONS AS NEEDED. �CU-3 208 1 12 C-30,32 2�12 & 1�12G - 3�4° C. 30 � 15 3R �� NOiE GOORDINATE EXM.T LOCATIONS AN� ELECTFICAL REOUIREMENTS OF ALL MECHANICAL EQUIPI�ENT NOTE: EXISiING POWEF POLES AND GON�OLAS BEING RELOGATED BASED ON THE FlNAL MEFCHANDISE PLAN. GC SHALL COORDINAiE WITH RNAL MERCHANDISE PLAN TO IDENTIFYING GONDOLAS AND POWER POLES TO BE RELOCATED AND SHALL RELOCATE AS REQUIRED- RECONNECT GONDOLA WIRING CHASE CIRCWT> TO EXISTING CIRCUITS. VERIFY CHASE IS WORKING AFTER INSTALLATION_ � ��� pharmacy� HUB�ADA/SSSI�ACO STORE NUI�BER 01367 13090 PETTIGRU DR. CARMEL, IN- 46032 CAPCODE (90�113�88�114) CS PRO�IECT NUMBBT 138457 ARCHITECT OF RECORD� C� CONSULTANT ENGINEER� CONSULTANT� SEAL� HEALTHHUB GENERALNOTES i. aeoNoe HosPirn� caaoe w�eiNc, s. iNsrn� Hosvira� cenoe, iso�nreo RECEPTACLES AND SWITCHES FOR THE �ROUND RECEPTACLES SIMIUR i0 LEVITON "HEALiHHUB". INSiALL WIRING AND a8300-IG iYPICAL FOR RECEPTACLES IN DEVICES IN ACCORDANCE N7TH NEC ARTICLE HEALTHHUB. CABLING PoR 1HESE sn. a�cearnc�s Mnv us� emio cnNouir oe iYPE HCF-90 CABLE (MC CABLE IS NOi 2 REfER TO LOW VOLTAGE SPEC MANUAL ACCEPTABLE). (REDBOOK) PoR ADDIiIONAL WFORMATION_ 6. CONiRACiOR i0 VEPoFY E%ISTENCE OF S ALL HEALTHHUB CIRCUITS SHALL BE ON A VOICE CABMEi (WHIiE CABMEi} IF NO DEDICAiED CIRCUIi. WHIiE CABWET EXISiS ALL GkAY JACKS SHOWN IN iH15 FIGURE WILL BE REPLACED 4 CONNECT HEALTHHUB IJGHTING TO WIiH 6LACK JACKS AND CPBLES RUN i0 EIAS�iIMER ALONG WITH OiHER REiAIL iHE FUIL SIZE CABWEI. EIiHER i OR 8'. IJGHiING KEYED NOTES - HEALTHHUB POWER Pi PROVIDE MOiOR-RATED DISCONNECT SWITCH MOUNTED AT 18� AFF POR INSTANTANEOUS WATER HEATER. CONNECT TO DEDICATED GFCI 30A-2P CIRCUIi BREAKER WIiH 2 g10 & 1 #10(G) - 3/4" C. pp JUNCTION BOX MUUNT AT 53" AFF FOR UNDERCABWET LIGHiS- CUNNECT 10 ROOM'S CEILING LIGHiING CIRGUIL P3 PRGVIDE POWER TO LEARNING TABLE VIA POwER GROP WITH ALL COMPONENiS WGLUDIN6 BUi NOi LIMIiED i0 SiRAIN RELIEF FOR A COMPLETE AND STATIONARY INSTALLATIGN. J-BOx TO BE FWSH MOUNTED WITH CBLING GRID AND SEWRED TO STRUCTURE ABOVE PROVIDE A DUPLEX RECEPTACLE MOUNTED UNDERSIDE OF COUNTER CONNECTEfI TO POWER DROP. TIE UP WITH CABLE TIES OR CLIPS AS REQUIRED TO MAKE CLEAN AND TIDY ROUTING OP CABLES. P4 PROVIDE FWSH MOUNTED DUPLEX RECEPTACLE FOR CHARGIN� TABLE. PS RELOCATE� PROVIDE WIRING CHASE TO BE AS MANUFACTURED BY WEIDENBACH-BROWN WITH ALL COMPONENTS PoR A COMPLETE AND SiAiIONARY MSiALLAiION_ PROVIDE JUNCiION BOX 6" ABOVE CEILING FpF WIRING CHASE CONNECTION. VERIFY LENGTH OF WIRING CHASE REUUIRED PRIOR TO ORDERING. pd PROVIDE 1/2"C AND PULL WIRE FROM 6" ABOVE CBLING TO SINGLE GANG JUNCTION BOX LOCATED 40"" AFF FOR VOWME CONTROL. P� ALARM PUSH BUTTON. PROVIDE JUNCTION BOX WITH 3/4"C WITH PULLVNRE TO 6" ABOVE CEIIJN6. P8 DEDICATED GFCI DUPLEX RECEPTACLE FOR DRAIN PUMP. COORDINATE WITH MECHANICAL TRP,DE FOR PLACEMENT. GC TO COORDINATE WITH CVS VENDOR FOR RELOCATION /RBNSTALLATION OF ALL CAMERAS, MOTION DETECTOR$ SECURITY EQUIPMENT MCWDING FlRE ALARM EOUIPMENT. REVISIONS: 04-13-2020 PERMIT SET DRAWING BY: S. BEBA CVS PROJECi MANAGER: E ROSARIO DATE 04-13-2020 JOB NUMBER: JCDi19.0397.00 TITLE HEALTHHUB POWER PLAN SHEET NUMBER: E6 COMMENTS: DATE: � _ �un��\i lo•rvalM��_ 08�20�2�