(E)SUPPLY
DIFFUSER
250 CFM
(ttP. 4)
EIAPLOYEE
(E)SOPPLY
DIFFOSER
100 CFM
� -
_ MANA�
� 1
(E)TRANSFER
GRILLE�� I
�... � �, — �.
HALL
(E)UNIT
HEATER
/�
RG-1 O6
� � 8"NK
SD-1 150 CFM
8"NK 3O
150 CFM �
I
8"0
SO-1 AHU-3 O
8"NK 0 CEILING 5
RECESSE� CU O
Za� �� 0 MOUNTED I
RG-1
- -� - 8"NK OO
2�0 CFM
i � , �(E)17•6 f10'0
/
= i
� ii RECEIVING
i RHC-2
�, s�ac-i
i 8"VC
200 CFM
__ �, .i � I-T�� _.... ��.
O4 CU-1
MOUNTED
ON R00 �
� RHC-1
� AHU-1 O
�j (E)SUPPLY CEIIJNG
DIFFUSER RECESSE�
100 CFM �
150 CFM I (E)SUPPLY II�_II
L DIFFUSER
. 100 CFM
�� (E)12"x12�•
TRANSFER DUCT
�� �
\,
PHARMACY
AREA
(E)RETURN
GRILLE
CONSULT
� ,� AH�_zo
CEILING 5
RECESSED
SD-1 3
8'"NK O �
200 CFM
I
�(E)18"0
O6 RG-1
8"NK
200 CFM � R"m
100 CFM
�z� MECHANICAL NEW WORK PLAN �
MZ ��y.._�._o..
NEW WORK NOTES BY SYMBOL
�j EHISTWG DIFFUSER TO BE LOCAIE� AS O INSTALL NEW CEILING MOUN7ED AIR
SHOWN AN� REBALANCE� TO AIR HAN�LING UNIT PER MANUFACTURER
FLOW SHOWN ON PLAN. RECOMMEN�ATIONS. 7HE MECHANICAL
CON7RACTOR TO FURNISH CON�ENSAIE
O2 EHISTWG SUPPLY AIR �IFFUSER TO BE PUMP FOR EACH AIR HAN�LER UNIT
REBALANCE� TO AIRFLOW AS SHOWN AS WELL AS CONDENSATE DRAIN
ON PLAN. PIPING. REFER TO PWMBING �RAWINGS
FOR CONDENSATE DRNN PIPING.
O3 NEW SUPPLY AIR OIFFUSER TO BE
INSTALLEO AS SHOWN, EH7END NEW O6 NEW REIURN AIR GRILLE TO BE
SUPPLY DUCTWORK TO EXIS7ING INSTALLED AS SHOWN. EXTEN� NEW
SUPPLY NR DUCT IAAIN OF EHISTING RETURN �UCTWORK TO EXISTING
RTU. NEW SUPPLY �UCiWORK SHALL RETURN AIR �UCT MAIN OF EXISTING
BE INSULATE�. BALANCE NEW AIR R7U. BALANCE TO CFM LIS7ED ON
DIFFUSER TO CFM LIS7ED ON PLAN. PLAN. COOR�INAIE WI7H O7HER ABOVE
COOR�INATE WI7H O7HER ABOVE CEILING 7RADE5 FOR ROUTING
CEILING TRA�ES FOR ROUPNG REQUIREMENTS. MECHANICAL
REOUIREMENTS. MECHANICAL CON7RACTOR SHALL VERIFY LOCATION
CONTRACTOR SHALL VERIFY LOCAPON OF EXIS7ING �UCT MAIN PRIOR TO
OF DUCT MAIN PRIOR TO BID�ING. BID�ING.
�4 INSTALL NEW ROOF TOP CONDENSYNG
UNIT PER MANUFACTURERS
RECOMMEN�ATIONS. ENSURE ALL ROOF
PENE7RAPONS ARE SEALE� WATER
PGHT. COOR�INATE LOCATION WI7H
EHISTWG ROOF TOP EQUIPMENT
(E)SUPPLY 7HE �RAWWGS AND SPEQRCATIONS ARE PRODUCE� REPRESENPNG WORK TO BE
DIFFUSER DONE IN ACCOR�ANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL
550 CFM CODES. THE LOCAL CODE AUTHORITY HAS THE AUTHORITY TO
INTERPRET CODE REQUIREMENTS IN THEIR JURISDICTION. THESE
INTERPRETATIONS MAY VARY FROM WFORMATION PRESENTED IN THE
DOCUMENTS. THE CONTRACTOR SHALL WFORM THE OWNER'S
REPRESENTATIVE AND THE ARCHITECT-ENGMEEER, OF RECORD, OF
THE DIFFERENCES AND SHALL PROCEED WITH THE WORK UPON
RECEIVING THEIR AGREEMENT WITH THE LOCAL CODE
RHC
WAITING
SENSOR TO BE
CONNECTED TO
EXISTING EMS
SYSTEIA.
12"0
CU=1 O
n�ouNTEo
ON ROOF
�(E)SUPPLY
DIFFUSER
550 CFM
NOTES
1. GENERAL NOiES ARE APPLICABLE i0 9. REFER TO �ETAIL 3/M1 FOR
ALL HVAC DRAWINGS. �IFFUSER/GRILLE WSTALLA710N.
2. PERPoRM WORK IN ACCORDANCE W1TH �0. CVS/PHARMACY HAS ENTERED INTO A
iHE LATEST EDITIONS, REVISIONS, NATIONAL ACCOUNT AGREEIAENT WITH
AMENDMENiS, OR SUPPLEMENTS OF CPC FOR FURNISHING THE ENERGY
APPLICABLE SiATUTES, ORDINANCES, MANAGEMENT SYSTEM SPECIFlED ON
CODES OR REGULATIONS OF FEDERAL, SHEET E8. FOR FURTHER WFORMATION,
SiATE, AND LOCAL AUiHORITIES HANNG CALL CPC AT (800) 829-2724. AS
JURISDICTION M EFFECT ON THE DAiE pqRT OF THIS SYSTEM, TEMPORARY
BIDS ARE RECENE�. THERMOSTATS FOR iHE ROOFTOP UNITS
3. WHERE APPROVED STANDARDS HAVE SHALL BE PRONDED BY THE HVAC
BEEN ESTABL6HED BY OSHA, CONiRACTOR TO lEST AND BALANCE
UNDERWRIiERS LABORATOPoES, AMERICAN THE HVAC EOUIPMENT PRIOR TO FINAL
CODES, ASA, ASHRAE, ARI, NEC, STAIE INSTALLA7ION OF SENSORS BY THE EMS
FlRE WSURANCE REGULATION BODY, CONiRACTOR. CONiRACTOR SHALL
NFPA OR OTHERS. VERIFY TEMPORARY iHERMOSTATS ARE
MOUNTED AT LOCAiIONS INDICATED.
4. THESE STANDARDS SHALL BE PoLLOWED �� 7HE DRAWINGS AND SPECIFICA7ION5 ARE
WHETHER OR NOT INDICAiED ON iHE PRODUCED REPRESENTING WORK TO BE
DRAWING AND SPECIFlCATIONS. DONE IN ACCORDANCE WI7H ALL
5. ALL DUCT TO BE OF 2" PRESSURE APPLICABLE FEDERAL, STATE AND LOCAL
CLASS, UNLESS NOTEO OTHERWISE. CODES. THE LOCAL CODE AU7HORITY
HAS THE AU7HORITY TO INTERPRET CODE
6. LIGHT FIHIDRE LOCATIONS TAKE REQUIREMENTS IN THEIR JURISDICTION.
PRECEDENCE OVER �IFFUSER AN� GRILLE THESE INTERPRETATIONS MAY VARY
LOCATIONS LOCATE �IFFUSERS AND FROM INFORMATION PRESEN7ED IN THE
GRILLES TO ACWMMODATE LIGHTING DOCUMEM4 THE CON7RACTOR SHALL
LAYOUT MFORM THE OWNER'S REPRESENTAPVE
AN� THE ARCHITECT-ENGMEER, OF
7. �UCT SIZES SHOWN ARE NET FREE RECORD, OF THE �IFFERENCES ANO
AREA SHALL PROCEE� R77H 7HE WORK UPON
RECEIVING THEIR AGREEMENT WITH THE
S. �UCTWORK SHALL NOT BE SUPPORTE� LOCAL CODE AU7HORITY INTERPRETA710N.
FROM BRIDGING. DO NOT USE FASTENERS
THAT PENE7RAlE ROOF DEG(.
LEGEND
OT AHU REMOIE CONTROLLER
EMS SENSOR: EMERSON CLIMATE TECH SOLUTIONS-
� coNTncT: (eoo) aze-z�za
1O NOIES BY SYMBOL
� SUPPLY AIR DIFFUSERS:
(METALAIRE SERIES 57�0 FINISH WHITE.
PRONDE FRAME SUITABLE FOR LAY-IN CEILWG)
� REIURN AIR DIFNSERS.
(METALAIRE SERIES CC1 FlNISH WHITE.
PRONDE FRAME SUITABLE FOR LAY-IN CEILING)
CFM CUBIC FEET NK NECK
PER MINUIE AFF ABOVE FINISHE�
�N. DOWN FLOOR
C� CONOENSAIE �RAW EHH. EXHAUST
SA SUPPLY AIR REQ'D RE�UIRE�
RA REIDRN AIR �MPR �AMPER
F� FIRE �AMPER 5� SUPPLY AIR �IFFUSER
RG RETURN AIR GRILLE
DEMOLITION NOTES BY SYMBOL
OA REIAOVE EXISTWG SUPPLY AIR OC REMOVE E%ISTING WALL MOUNTED AIR
DIFFUSER AND SUPPLY AIR DUCTWORN CONDITIONING UNIT AND ASSOCIATED
AS SHOWN. ROOF MOUNTED CONDENSING UNIT.
REIAOVE ALL WIRING AND PIPING.
OB REIAOVE EXISTWG SUPPLY AIR REFER TO ARCHITECTURAL iRADES
DIFFUSER AND RETAW FOR FOR ALL PATCHING RE�UIREMENTS.
RELOCATION.
OD REIAOVE TRANSFER GRILLES AND ANY
CONNECTING DUCTWORK. COORDINATE
PATCHING OF WALL WI7H
ARCHITECTORAL TRA�ES.
�(E)12"fl �
�(e)te"m ro (e) ero
RETURN MAIN
(E)20"4
�
\
�
ID (E) RTU
�(E)12°0
REiAIL
AREA
�'��
pharmacyn
HUB/ADA/SSSI/ACO
STORE NUMBER 01367
13090 PETTIGRU DR.
CARMEL, IN. 46032
CAPCODE (90�113�88�114)
CS PRo,IECT NUMBER 138457 I
ARCHITECT OF RECORD�
r1
LJ
CONSULTANT ENGINEER�
CONSULTANT�
SEAL�
REVISIONS:
04-13-2020
DRAWING BY:
CVS PROJECT MANAGER:
DATE:
JOB NUMBER:
TITLE
SHEET NUMBER:
PERMIT SET
R. McCARTHY
E. ROSARIO
04-13-2020
JCDT19.0397.00
MECHANICAL