HomeMy WebLinkAbout01367IN_M2. _____� _____ � L_____J L______J �� (E)SUPPLY DIFFUSER 250 CFM (ttP. 4) EIAPLOYEE (E)SOPPLY DIFFOSER 100 CFM � - _ MANA� � 1 (E)TRANSFER GRILLE�� I �... � �, — �. HALL (E)UNIT HEATER /� RG-1 O6 � � 8"NK SD-1 150 CFM 8"NK 3O 150 CFM � I 8"0 SO-1 AHU-3 O 8"NK 0 CEILING 5 RECESSE� CU O Za� �� 0 MOUNTED I RG-1 - -� - 8"NK OO 2�0 CFM i � , �(E)17•6 f10'0 / = i � ii RECEIVING i RHC-2 �, s�ac-i i 8"VC 200 CFM __ �, .i � I-T�� _.... ��. O4 CU-1 MOUNTED ON R00 � � RHC-1 � AHU-1 O �j (E)SUPPLY CEIIJNG DIFFUSER RECESSE� 100 CFM � 150 CFM I (E)SUPPLY II�_II L DIFFUSER . 100 CFM �� (E)12"x12�• TRANSFER DUCT �� � \, PHARMACY AREA (E)RETURN GRILLE CONSULT � ,� AH�_zo CEILING 5 RECESSED SD-1 3 8'"NK O � 200 CFM I �(E)18"0 O6 RG-1 8"NK 200 CFM � R"m 100 CFM �z� MECHANICAL NEW WORK PLAN � MZ ��y.._�._o.. NEW WORK NOTES BY SYMBOL �j EHISTWG DIFFUSER TO BE LOCAIE� AS O INSTALL NEW CEILING MOUN7ED AIR SHOWN AN� REBALANCE� TO AIR HAN�LING UNIT PER MANUFACTURER FLOW SHOWN ON PLAN. RECOMMEN�ATIONS. 7HE MECHANICAL CON7RACTOR TO FURNISH CON�ENSAIE O2 EHISTWG SUPPLY AIR �IFFUSER TO BE PUMP FOR EACH AIR HAN�LER UNIT REBALANCE� TO AIRFLOW AS SHOWN AS WELL AS CONDENSATE DRAIN ON PLAN. PIPING. REFER TO PWMBING �RAWINGS FOR CONDENSATE DRNN PIPING. O3 NEW SUPPLY AIR OIFFUSER TO BE INSTALLEO AS SHOWN, EH7END NEW O6 NEW REIURN AIR GRILLE TO BE SUPPLY DUCTWORK TO EXIS7ING INSTALLED AS SHOWN. EXTEN� NEW SUPPLY NR DUCT IAAIN OF EHISTING RETURN �UCTWORK TO EXISTING RTU. NEW SUPPLY �UCiWORK SHALL RETURN AIR �UCT MAIN OF EXISTING BE INSULATE�. BALANCE NEW AIR R7U. BALANCE TO CFM LIS7ED ON DIFFUSER TO CFM LIS7ED ON PLAN. PLAN. COOR�INAIE WI7H O7HER ABOVE COOR�INATE WI7H O7HER ABOVE CEILING 7RADE5 FOR ROUTING CEILING TRA�ES FOR ROUPNG REQUIREMENTS. MECHANICAL REOUIREMENTS. MECHANICAL CON7RACTOR SHALL VERIFY LOCATION CONTRACTOR SHALL VERIFY LOCAPON OF EXIS7ING �UCT MAIN PRIOR TO OF DUCT MAIN PRIOR TO BID�ING. BID�ING. �4 INSTALL NEW ROOF TOP CONDENSYNG UNIT PER MANUFACTURERS RECOMMEN�ATIONS. ENSURE ALL ROOF PENE7RAPONS ARE SEALE� WATER PGHT. COOR�INATE LOCATION WI7H EHISTWG ROOF TOP EQUIPMENT (E)SUPPLY 7HE �RAWWGS AND SPEQRCATIONS ARE PRODUCE� REPRESENPNG WORK TO BE DIFFUSER DONE IN ACCOR�ANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL 550 CFM CODES. THE LOCAL CODE AUTHORITY HAS THE AUTHORITY TO INTERPRET CODE REQUIREMENTS IN THEIR JURISDICTION. THESE INTERPRETATIONS MAY VARY FROM WFORMATION PRESENTED IN THE DOCUMENTS. THE CONTRACTOR SHALL WFORM THE OWNER'S REPRESENTATIVE AND THE ARCHITECT-ENGMEEER, OF RECORD, OF THE DIFFERENCES AND SHALL PROCEED WITH THE WORK UPON RECEIVING THEIR AGREEMENT WITH THE LOCAL CODE RHC WAITING SENSOR TO BE CONNECTED TO EXISTING EMS SYSTEIA. 12"0 CU=1 O n�ouNTEo ON ROOF �(E)SUPPLY DIFFUSER 550 CFM NOTES 1. GENERAL NOiES ARE APPLICABLE i0 9. REFER TO �ETAIL 3/M1 FOR ALL HVAC DRAWINGS. �IFFUSER/GRILLE WSTALLA710N. 2. PERPoRM WORK IN ACCORDANCE W1TH �0. CVS/PHARMACY HAS ENTERED INTO A iHE LATEST EDITIONS, REVISIONS, NATIONAL ACCOUNT AGREEIAENT WITH AMENDMENiS, OR SUPPLEMENTS OF CPC FOR FURNISHING THE ENERGY APPLICABLE SiATUTES, ORDINANCES, MANAGEMENT SYSTEM SPECIFlED ON CODES OR REGULATIONS OF FEDERAL, SHEET E8. FOR FURTHER WFORMATION, SiATE, AND LOCAL AUiHORITIES HANNG CALL CPC AT (800) 829-2724. AS JURISDICTION M EFFECT ON THE DAiE pqRT OF THIS SYSTEM, TEMPORARY BIDS ARE RECENE�. THERMOSTATS FOR iHE ROOFTOP UNITS 3. WHERE APPROVED STANDARDS HAVE SHALL BE PRONDED BY THE HVAC BEEN ESTABL6HED BY OSHA, CONiRACTOR TO lEST AND BALANCE UNDERWRIiERS LABORATOPoES, AMERICAN THE HVAC EOUIPMENT PRIOR TO FINAL CODES, ASA, ASHRAE, ARI, NEC, STAIE INSTALLA7ION OF SENSORS BY THE EMS FlRE WSURANCE REGULATION BODY, CONiRACTOR. CONiRACTOR SHALL NFPA OR OTHERS. VERIFY TEMPORARY iHERMOSTATS ARE MOUNTED AT LOCAiIONS INDICATED. 4. THESE STANDARDS SHALL BE PoLLOWED �� 7HE DRAWINGS AND SPECIFICA7ION5 ARE WHETHER OR NOT INDICAiED ON iHE PRODUCED REPRESENTING WORK TO BE DRAWING AND SPECIFlCATIONS. DONE IN ACCORDANCE WI7H ALL 5. ALL DUCT TO BE OF 2" PRESSURE APPLICABLE FEDERAL, STATE AND LOCAL CLASS, UNLESS NOTEO OTHERWISE. CODES. THE LOCAL CODE AU7HORITY HAS THE AU7HORITY TO INTERPRET CODE 6. LIGHT FIHIDRE LOCATIONS TAKE REQUIREMENTS IN THEIR JURISDICTION. PRECEDENCE OVER �IFFUSER AN� GRILLE THESE INTERPRETATIONS MAY VARY LOCATIONS LOCATE �IFFUSERS AND FROM INFORMATION PRESEN7ED IN THE GRILLES TO ACWMMODATE LIGHTING DOCUMEM4 THE CON7RACTOR SHALL LAYOUT MFORM THE OWNER'S REPRESENTAPVE AN� THE ARCHITECT-ENGMEER, OF 7. �UCT SIZES SHOWN ARE NET FREE RECORD, OF THE �IFFERENCES ANO AREA SHALL PROCEE� R77H 7HE WORK UPON RECEIVING THEIR AGREEMENT WITH THE S. �UCTWORK SHALL NOT BE SUPPORTE� LOCAL CODE AU7HORITY INTERPRETA710N. FROM BRIDGING. DO NOT USE FASTENERS THAT PENE7RAlE ROOF DEG(. LEGEND OT AHU REMOIE CONTROLLER EMS SENSOR: EMERSON CLIMATE TECH SOLUTIONS- � coNTncT: (eoo) aze-z�za 1O NOIES BY SYMBOL � SUPPLY AIR DIFFUSERS: (METALAIRE SERIES 57�0 FINISH WHITE. PRONDE FRAME SUITABLE FOR LAY-IN CEILWG) � REIURN AIR DIFNSERS. (METALAIRE SERIES CC1 FlNISH WHITE. PRONDE FRAME SUITABLE FOR LAY-IN CEILING) CFM CUBIC FEET NK NECK PER MINUIE AFF ABOVE FINISHE� �N. DOWN FLOOR C� CONOENSAIE �RAW EHH. EXHAUST SA SUPPLY AIR REQ'D RE�UIRE� RA REIDRN AIR �MPR �AMPER F� FIRE �AMPER 5� SUPPLY AIR �IFFUSER RG RETURN AIR GRILLE DEMOLITION NOTES BY SYMBOL OA REIAOVE EXISTWG SUPPLY AIR OC REMOVE E%ISTING WALL MOUNTED AIR DIFFUSER AND SUPPLY AIR DUCTWORN CONDITIONING UNIT AND ASSOCIATED AS SHOWN. ROOF MOUNTED CONDENSING UNIT. REIAOVE ALL WIRING AND PIPING. OB REIAOVE EXISTWG SUPPLY AIR REFER TO ARCHITECTURAL iRADES DIFFUSER AND RETAW FOR FOR ALL PATCHING RE�UIREMENTS. RELOCATION. OD REIAOVE TRANSFER GRILLES AND ANY CONNECTING DUCTWORK. COORDINATE PATCHING OF WALL WI7H ARCHITECTORAL TRA�ES. �(E)12"fl � �(e)te"m ro (e) ero RETURN MAIN (E)20"4 � \ � ID (E) RTU �(E)12°0 REiAIL AREA �'�� pharmacyn HUB/ADA/SSSI/ACO STORE NUMBER 01367 13090 PETTIGRU DR. CARMEL, IN. 46032 CAPCODE (90�113�88�114) CS PRo,IECT NUMBER 138457 I ARCHITECT OF RECORD� r1 LJ CONSULTANT ENGINEER� CONSULTANT� SEAL� REVISIONS: 04-13-2020 DRAWING BY: CVS PROJECT MANAGER: DATE: JOB NUMBER: TITLE SHEET NUMBER: PERMIT SET R. McCARTHY E. ROSARIO 04-13-2020 JCDT19.0397.00 MECHANICAL PLANS & NOTES M2 COMMENTS: