Loading...
HomeMy WebLinkAbout01367IN_M3SPIN-IN MSULATED RIGID METAL DUCT AND ELBOw INSULATED REX DUCT SEISMIC RESTRAINT. MIN. 2 ON OPPOSITE CORNERS. (MIN) WSULATED SUPPLY AIR TRUNK DUCT - REFER TO PLAN INSULATED SPW-IN FITTING WITH MANUAL DAMPER AND ACCESSIBLE INDICATING HAN�LE - TYPICAL INSULATED _ DRAW-BAND CLAMP - FLEX DUCT TYPICAL EACH END SEISMIC RESTRAINT. MIN. 2 ON OPPOSITE CORNERS. MAX OFFSET ALLOWABLE: 2-WCHES PER FOOT OF FLEXIBLE DUCT LENGTH CLAMP - 1 END MAX OFFSET ALLOWABLE: 2-MCHES PER FOOT OF FLEXIBLE DUCT LENGTH INSULATE TOP OF DIFFUSER (MAY BE OMITiED WHERE CEILING CAVITY IS USED AS A RETURN � AIR PLENUM) - TYPICAL �CBLING AIR DEVICE - �CEIIJNG TYPICAL LONG RUN SIDE TAP INSTALLATION CEILING DIFFUSER/RETURN �z� GRILLE CONNECTION DETAIL M3 NOT TO SCALE MAW SUPPLY DUCT OR SUB-MAIN 1/4 W. 4" � MIN. BRANCH DUCT PROVIDE VOWME DAMPER (OBMVD) W SUPPLY AIR DUCT BOTTOM TAP INSTALLATION z"x2"xi/a ANGLE OR UNISTFUT VO UNE DAMPEd f�il �CONICALTAP ROUND BRANCH MAIN SUPPLY DUCT (OR SUB-MAIN) RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM��_ DATE: OH/ZO/2O TWO SHEET MI SELF TAPPING SCREWS ROUND DUCTWORK MAW SUPPLV TWO SHEI SELF TAF oucr (oR scRews SUB-MAIN) RECTANGULAR TO ROUND SIDE DUCT TAKE-OFF 18 GAUGE VOWME DAMPER WITH LOCKING QUADRANT SET (TYR FOR ALL SUPPLY/RETURN/ EXHAUST AIR BRANCH DUCT) OFF DETAILS ROUND DUCTWOF JOIST RECTANGULAR DUCTWORK DUCT SUPPORT PA3ALLEL TO TRUSSES NOTES: 7. ALL DUCT & SUPPORTS PER UMC. �� DUCT HANGER DETAIL M3 NOT TO SCALE MINI SPLIT SYSTEM SCHEDULE weF�ow e�ecTeicn� TAG MANUFACTURER MODEL NUMBER CFM LOW/1AED/HIGH MCA MOCP EER/SEER HSPF REIAARKS VOLT/PHASE AHU-1 MITSUBISHI NTxCK512A11A 230/265/335 208/1/60 0.30 -- -- --- 1,2,3,4,5 CU-1 MITSUBISHI NTXSK512A112A -- 208/1/60 9 16 13.3/220 1L4 1,6,7 AHU-2 MITSUBISHI NTXCKS72A17A 230/2fi5/E35 208/7/60 0.3� -- -- -- 1,2,3,4,5 CU-2 MITSUBISHI NixSK512An2A -- 208�1/60 9 16 13-3�220 n.4 1,6,7 nHu—a MiTsueisni NTzcKsiznna �3o/2ss/a3s zoe/i�so 0.30 -- --- --- i,2.a,a,e CU-3 MITSUBISHI NTXSNS12A112A -- 208/7/60 9 16 13.3/22.0 11.4 1,6,7 NUItS 1. APPROVED MANUFACTURERS INCLUDE PANASONIC, FUJITSU. IF ALTERNATE MANUFACTURERS ARE USED, COORDINATE CHANGES WITH ELECTRICAL, STRUCTURAL AND ARCHITECTURAL TRADES. ANY ADDITIONAL COSTS DUE TO CHANGES RESULTWG FROM THE USE OF ALTERNATE MANUFACTURERS SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR. 2 INSTALL PER MANUFACTURER INSiRUCTIONS COMPLEiE WITH REFRIGERANT PIPING, FULL REFRIGERANT CHARGE, AND PROPER STARTUP PROCEDURES 2. PROVIDE WITH INTEGRATED CONDENSATE DRAIN PU�IP WITH SINGLE POINT POWER CONNECTION TO AHU. PROVIDE WITH INTEGRATED CONDENSATE DRAIN PAN AND DRAIN UNDER THE UNIT COIL PROVIDE DRAM LEVEL SENSOR (DPLS2), CONNECTED TO CONTROL PANEL, TO PREVENT CONDENSATE FROM OVERFLOWING. 3. SLP-18FAU GRILLE. 4. TAR-40MAAU (WIRE� PftOGRAMMABLE REMOTE CONTROLLER� 5. PROVIDE 2q12,p12G, 1/7b FROM CU TO AHU GRILLE, REGISTER, DIFFUSER SCHEDULE TAG SERVICE CFM NECK SIZE FRAME pAThRN DAIAPER MATERIAL FlNISH MANUFACTURER & MODEL TWE N0. SD-1 SUPPLY SEE PLANS SEE PLANS NOTE 1,2 4-WAY YES STEEL OFF-WHIIE METALAIRE 5500 SERIES RG-1 RETURN SEE PLANS SEE PLANS NOTE 1,2 NONE NO STEEL CF=-WHI-E METALAIRE CC1 CUBE CORE RET./E%HAUST NOIE: 1. MODEL NUMBERS ARE METALAIRE UNLESS O7HERWISE NOTED. 2. PRONDE TRANSITION TO DIFFUSER WHERE REQUIRED. �'�� pharmacyn HUB/ADA/SSSI/ACO STORE NUMBER 01367 13090 PETTIGRU DR. CARMEL, IN. 46032 CAPCODE (90�113�88�114) CS PRo,IECT NUMBER 138457 I ARCHITECT OF RECORD� i-1 U CONSULTANT ENGINEER� CONSULTANT� SEAL� REVISIONS: 04-13-2020 DRAWING BY: CVS PROJECT MANAGER: DATE: PERMIT SET R. McCARTHY E. ROSARIO 04-13-2020 JOB NUMBER: JCDT19.0397.00 TiT�E: MECHANICAL SCHEDULES & DEfAILS SHEET NUMBER: M3 COMMENTS: DUCT SUPPORT PERPENDICULAR TO TRUSSES