HomeMy WebLinkAbout01367IN_P1SECiION 22 0523
GENERAL-DUIY VAWES FOR PLUMBING PIPING
PART 1 GENERAL
L01 SECiION INCLUDES
A. APPLICATIONS.
B. GENERAL REQUIREMENTS.
G BALL VALVES.
D. CHECK VALVES.
1A2 REFERENCE STANDARDS
A. ASME B16.18 - CAST COPPER ALLOY SOLDER JOINT PRESSURE FlTTINGS�, 2012.
B. ASTM 862 - STANDARD SPECIFlCATION FOR COMPOSITION BRONZE OR OUNCE 1ABAL
CASTINGS; 2017.
C. MSS SP-45 - BYPASS ANO �RAIN WNNECTIONS 2003 (RFAFFIkMED 2008).
D. MSS SP-80 - BRONZE GATE, GLOBE, ANGLE ANO CHECK VALVES; 2013.
E. MSS SP-110 - BALL VALVES THRFAOED, SOCKEf-WELDING, SOLDER JOINT, GROOVE� AND
FLARED ENDS; 2010.
F. NSF 61 - DRINKING WATER SYSTEM WMPONENTS - HFALTH EFFECTS�, 2017.
G. NSF 372 - DRINKING WATER SYSTEM COMPONENTS - LFAO CONTENT; 2016.
1.03 QUAIJiY ASSURANCE
A. MANUFACTURER�.
1. OBTAIN VALVES FOR FACH VANE iYPE FROM SINGLE MANUFACTURER.
2 COMPANY MUST SPECIALRE IN MANUFACTURING PRODUCTS SPECIFIED IN THIS SECTION,
WITH NOT LESS THAN THREE YFARS OF DOCUMENTED EXPERIENCE.
1.04 DELIVERY, STORAGE, ANO HANDLING
A. PREPARE VALVES FOR SHIPPING AS FOLLOWS:
1. MINIMIZE E%POSURE OF OPERABLE SURFACES BY SETfING PWG ANO BALL VALVES TO
OPEN POSITION.
2 PROTECT VALVE PARTS EXPOSED TO PIPED ME�IUM AGAWST RUST AN� CORROSION.
3. PROTECT VALVE PIPING WNNECTIONS SUCH AS GROOVES, WELD EN�S, THREADS, AN�
FLANGE FACES.
4. SECURE CHECK VALVES W EITHER THE CLOSE� POSITION OR OPEN POSITION.
B. USE THE FOLLOWING PRECAUTIONS DURING S�ORAGE:
1. MAINTAIN VALVE END PROTECTION AND PROTECT FIANGES AN� SPECIALTIES FROM DIRT.
A. PROVI�E TEMPORARY WLET AND OUTLEf CAPS.
B. MAINTAIN CAPS IN PIACE UNTIL INSTALLATION.
2 STORE VALVES IN SHIPPING CONTAINERS AND MAINTAIN IN PLACE UNTIL INSTALlATION.
A. STORE VALVES INDOORS IN �RY ENVIRONMENT.
B. STORE VALVES OFF THE GROUN� IN WATERTIGHT ENCLOSURES WHEN INDOOR STORAGE IS NOT
AN OPTION.
PART 2 PRO�UCTS
201 APPLICATIONS
A. PROVI�E THE FOLLOWMG VALVES FOR THE APPLICATIONS IF NOT INDICATED ON DRAWINGS:
1. SHUTOFF�. BALL.
2 THROTfLING: BALL.
B. SUBSTITUTIONS OF VALVES WITH HIGHER CWP CVSSES Ok SWP RATINGS FOk SAME VALVE
iYPES ARE PERMITTE� WHEN SPECIFIEO CWP RATINGS OR SWP CIASSES ARE NOT AVAILABLE.
C. REQUIRED VALVE END CONNECTIONS FOR NON-WAFER lYPES:
1. COPPER TUBE:
A 2 NPS (50 �N) AN� SMALLER: THREA�E� ENDS EXCEPT WHERE SOL�ER�l01NT VALVE-END
OPTION IS IN�ICATED IN VALVE SCHEOULES BELOW.
B. 2-1/2 NPS (65 DN) i0 4 NPS (100 DN): GROOVED OR FLANGED ENDS ENCEPT WHERE
THREADED VALVE-END OPTION IS INDICATED IN VAWE SCHEDULES BELOW.
D. DOMESTIC, HOT AND COLD WATER VALVES:
L 2 NPS (50 DN) AND SMALLER:
A. BRONZE: PROVIDE WITH SOLDER-JOIM ENDS.
B. BALL iW0 PIECE, NLL PORT, BRONZE WITH STAMLESS-STEEL TRIM.
202 GENERAL REQUIREMENTS
A. VANE PRESSURE AND TEMPERATURE RATINGS�. NO LESS THAN RATING INDICATED; AS
REQUIRED FOR SYAEM PRESSURES AND TEMPERATURES.
B, VALVE SIZES: MATCH UPSTREAM PIPING UNLESS OTHERWISE INDICATED.
C. VALVES IN INSUTAiE� PIPING: WITH 2 NPS (50 �N) SiEM EX�ENSIONS AN� THE FOLLOWMG
FEATURES:
1. BALL VALVEB EX�ENDED OPERATING HANDLE OF NON-THERMAL-WNDUCTNE MATERIAL,
AN� PROTECTIVE SLEEVE THAT ALLOWS OPERATION OF VALVE WITHOUT BRFAKING THE
VAPOk SFAL OR �ISNRBING INSULATION.
2 MEMORY STOPS: FULLY ADJUSTABLE AFfER INSUlATION IS INS�ALLE�.
D. VALVE-END CONNECTIONS�.
1. SOL�ER JOINT CONNECTIONS: ASME B16.18.
E. GENERAL ASME COMPLIANCE�.
1. SOL�ER-JOINT CONNECTIONS: ASME B16.18.
F. VALVE MATERIALS FOR POTABLE WATER: NSF 61 AN� NSF 372.
G. BRONZE VALVES:
1. FABRICATE FROM DEZMQFICATION RESISTANT MATERIAL.
2 COPPER ALL0Y5 CONTAINING MORE THAN 15 PERCENT ZINC ARE NOT PERMITfED.
H. VALVE BYPASS AN� DRAIN CONNECTIONS: MSS SP-45.
I. SOURCE IJMITATIONS: OBTNN FACH VALVE iYPE FROIA A SINGLE MANUFACTURER.
203 BRONZE BALL VALVES
A. TWO PIECE, FULL PORT WITH STAMLESS S�EEL TRIM:
1. COMPLY WITH MSS SP-110.
2 SWP RATING: 150 PSIG (1035 KPA).
3. CWP RATING: 600 PSIG (4140 KPA).
4. BODY: LEAD FREE BROME.
5. ENDS: THREADED.
6- SEATS: PTFE.
7, SiEM: STAINLE55 AEEL.
8. BALL STAINLESS STEEL, VEMED.
9. MANUFACTURERS:
A. CRANE.
B. [NIBCO].
C. WATfS.
204 BRONZE SWING CHECK VALVES
A. CLASS 125: CWP RATING: 200 PSIG (1J80 KPA).
1. COMPLY WITH MSS SP-B0, IYPE 3.
2 DESIGN: HORIZONTAL FLOW.
3. BO�Y'. LEAD FREE BRONZE, ASTM B62.
4. EN�S'. THREADE� AS INDICATED.
5. DISC: BRONZE.
6. MANUFACTURERS:
A. CRANE..
B. NIBLb.
C. WATfS.
PART 3 EXECUTION
3.01 EHAMINATION
A. DISCAR� ALL PACKING MATERIALS AN� VERIFY THAT VALVE INTERIOR, INCW�ING THRFA�S AN�
FLANGES ARE COMPLEfELY CLEAN WITHOUT SIGNS OF OAMAGE OR �EGRAOATION THAT COULD
RESULT W LEAKAGE.
B. VERIFY VALVE PARTS TO BE Fl1LLY OPERATIONAL IN ALL POSITIONS FROM CLOSE� ID FULLY
OPEN.
C. WNRRM GASKEf MATERIAL TO BE SUITABLE FOR THE SERVICE, TO BE OF CORRECT SIZE,
ANO WIiHOl1T �EFECTS THAT COl1L0 COMPROMISE EFFECTNENESS.
�. SHOUL� VALVE IS �EfERMMED TO BE DEFECTNE, REPIACE WITH NEW VALVE.
3.02 WSTALLATION
A. PROVIDE UNIONS OR FLANGES WITH VALVES TO FACILITATE EQUIPMENT REMOVAL AND
MAINTENANCE WMLE MAINTAINING SYSiEM OPERATION AND FULL ACCESSIBILIN FOR SERVICING.
B. PROVIDE SEPARATE VALVE SUPPORT AS REOUIRED ANO LOCAiE VALVE WIiH STEM AT OR
A90VE CENTER OF PIPING, IANNTAINING UNIMPEOE� STEM MOVEMENT.
G INSTALL CHECK VAWES WHERE NECESSARY TO MAINTAIN �IRECTION OF FLOW AS FOLLOWS:
RELEA5E0 FOR CONSTRIICTI�N ERHiNCE PiN ��vE�.
Su6ject�o compliance with allregula�ions
of S�a�e antl Local Codes
City of Carmel
r
�un��\i lo•rvalM��_
DATE: OH/ZO/2O
A. PIPING INSULATION.
1.02 REFERENCE STANDARDS
A ASTM C177 - STANDARD iESi METHOD FOR STEADY-SiATE HEAi FLUX MEASUREMENTS AND
iHERMAL TRANSMISSION PROPERilES BY MEANS OF THE GUARDED-HOT-PLATE APPARATUS;
2013.
B. ASTM C449 - STANDARD SPECIFICATION FOR MWERAL FIBER HYDRAULIC-SEffING THERMAL
INSUTATING AND FIN6HING CEMENT; 2007 (REAPPROVED 2013).
C. ASTM C547 - STANDARD SPECIFICATION FOR MINERAL FIBER PIPE INSULATION; 2017.
D. ASTM C795 - STANDARD SPECIFICATION FOR THERMAL INSUlATION FOR USE IN CONTACT WITH
AUSTENITIC STAWLESS STEEL�, 2008 (REAPPROVE� 2013).
E. ASTIA E84 - STANDARD TEST MEfHO� FOR SURFACE BURNING CHARACTERISTICS OF BUIL�ING
n�arEain�s; zoia.
F. ASTM E96/E96M - STANDARD TESi METHODS FOR WAiER VAPOR TRANSMISSION OF
MAiERIALS; 2016.
G. UL 723 - SiANDARD FOR TEST FOR SURFACE BURNING CHARACiERISTICS OF BUILDING
MAiERIALS; WRRENi EDIiION, INCLUDING ALL REVISIONS.
1.03 QUALItt ASSURANCE
A MANUFACiURER QUALIFlCATIONS: COMPANY SPECIALIZING IN MANUFACiURING THE PRODUCiS
SPECIFlED IN THIS SECTION WITH NOT LESS THAN iHREE YEARS OF DOCUMENTED E%PERIENCE.
B. APPLICATOR OUALIFlCATIONS: COMPANY SPECIALIZING IN PERFORMING THE iYPE OF WORK
SPECIFlED IN iH15 SECTION WITH MINIMUM 3 YEARS OF E%PERIENCE.
1-04 DELNERY, STORAGE, AND HANDLING
A. ACCEPT MATERIALS ON SITE, IABELED WITH MANUFACTURER'S IDENTIFICATION, PRODUCT
DENSIIY, AND THICKNESS.
1.05 FIELD CONDITIONS
A. MAINTAIN AMBIEM WN�ITIONS RE�UIRED BY MANUFACTURERS OF EACH PRODUCT.
B. MAINTAIN TEMPERATURE BEFORE, DURING, AND AFfER INSTALLATION FOR MINIMUM OF 24
HOURS.
PART 2 PRODUCTS
201 REGUTATORY REQUIREMENTS
A. SURFACE BURNING CHARACTERISTICS: FIAME SPREA� INDEH/SMONE �EVELOPED INDEX OF
25/5�, MAXIMOM, WHEN TESTED IN ACCOR�ANCE WITH ASTM E84 OR UL 72b.
202 GIASS FIBER
A. MANOFACiURERS:
1. CERiAINTEED CORPORATION: WWW.CERTAINTEED.COM.
2 JOHNS MANVILLE CORPORATION: WWW.JM.COM.
3. KNAUF WSULATION; EARTHWOOL 1000 �EGREE PIPE INSUlATION�.
WWW. KNAU FINSU UTION.COM/j�SLE.
4- OWENS CORNING CORPORATION; FIBERGUS PIPE INSULAiION ASJ:
WWW.00BUI LDI NGSPEQCOM/#SLE.
B.INSUlATION: ASTM C547 AND ASTM C795; SEMI-RIGID, NONCOMBUSTIBLE, END GRAIN
ADHERE� TO JACKET.
1. 'K ('NSI') VAWE: ASTM C177, 424 AT 75 �EGREES F(�.035 AT 24 DEGREES C).
2. MAxIMUM SERVICE TEMPERATURE: 650 DEGREES F(343 DEGREES C).
3. MAxIMUM MOISiURE ABSORPTION�. 0.2 PERCENT BY VOLUTAE.
C. VAPOR BARRIER JACKET: WHITE KRAFf PAPER WITH GNSS FIBER YARN, BONDED TO
ALUMINRED RLM; MOISTURE VAPOR TRANSMISSION WHEN TESiED IN ACCORDANCE WIiH ASTIA
E96�E96M OF 0.02 PERM-INCHES (OA29 NG�PA S M),
�. TIE WIRE 0.048 INCH (L22 MIA) STAWLESS STEEL WITH 1WISTED ENDS ON MAXIMUM 12
INCH (J00 MM) CENTERS.
E. VAPOR BARRIER UP ADHESNE COMPATIBLE WITH INSUUTION.
F.INSUTATING CEMENT: ASTIA C449.
PART 3 EXECUTION
3.01 E%AMINATION
A. VERIFY THAT PIPING HAS BEEN TESTED BEFORE APPLYING WSULATION MATERIALS.
B. VERIFY THAT SORFACES ARE CLEAN AND DRY, WITH FOREIGN MATERIAL REIAOVED.
3D2 INSTALlATION
A INSTALL IN ACCORDANCE WIiH MANUFACTURER'S INSiRUCT10N5.
B-INSTALL IN ACCORDANCE WIiH NORiH AMERICAN INSUUTION MANUFACTURERS ASSOCIATION
(NniMa) NnnoNn� iNsuu�noN srnNoneos.
G EXPOSE� PIPING LOCATE INSULATION AN� COVER SEAMS W LFAST VISIBLE LOCATIONS.
D.INSUTATED PIPES CONVEYING FLUIDS BELOW AMBIENT TEMPERATURE: INSUTATE ENTIRE
SYSTEM INCWDING FITfINGS, VALVES, UNIONS, FIANGES, STRAINERS, FLEXIBLE CONNECTIONS,
PUMP BODIES, AND EXPANSION JOINTS.
E. GUSS FIBER WSUTATE� PIPES WNVEYING FWI�S BELOW AMBIENT TEMPERATURE�.
1. PROVIDE VAPOR BARRIER JACKEfS, FACTORY-APPLIE� OR FIELD-APPLIED. SECURE WITH
SELF-SFALING LONGITU�INAL IAPS AND BUTf STRIPS WITH PRESSURE SENSITIVE AOHESIVE.
SECURE WITH OUIWAR� CLINCH EXPANDING STAPLES ANO VAPOR BARRIER MASTIC.
2 INSUTATE FITfINGS, JOINTS, AN� VALVES WITH MOLDE� INSULATION OF LIKE MATERIAL AND
THICKNE55 AS A�JACENT PIPE. FINISH WITH GLA55 CLOTH AN� VAPOR BARRIER A�HESIVE
OR PVC FITfING COVEkS.
3.03 SCHEDULES
A. PWMBING SYSTEMS:
1. DOMESTIC HOT WATER SUPPLY:
A. GVSS FIBER WSUlATION:
i) PiPE s¢e anNce. i�z iNCH (is n�n�) aeo uP.
z) rHicuNess: i iNCH (zs n+n+).
2. DOMESiIC COLD WAiER�.
A. G1H55 FIBER INSUNiION:
1) PIPE SIZE RANGE�, 1/2 INCH (15 MM) AND UP.
2) THICKNESS�. 1 1/2 INCH (40 MM).
SECTION 22 1005
PWMBING PIPING
PART 1 GENERAL
1.01 SECTION INCWDES
A. PIPE, PIPE FITfINGS, SPECIALTIES, AN� CONNECTIONS FOR PIPING SYSTEMS.
1. SANITARY SEWER.
2. �OMESTIC WATEk.
J. PIPE HANGERS AN� SUPPORTS.
4. IAANUFACTURE� SLEEVE-SFAL SYS�EMS.
1.02 REIATE� RE�UIREMENTS
A.SECTION OB 310� - ACCESS �OOFS AND PANELS.
B. SECTION 22 051fi - EXPANSION FITfINGS ANO LOOPS FOR PWMBING PIPING.
1.03 REFERENCE STAN�ARDS
A. ANSI Z2L22 - AMERICAN NATIONAL STAN�ARD FOR RELIEF VALVES AN� AUTOMATIC GAS
SHUTOFF �EVICES FOR HOT WATER SUPPLY SYSTEMS; 2015.
B. ASME B16.18 - CAST LbPPER ALLOY SOL�ER JOINT PRESSURE FITfINGS 2012.
C. ASME B1622 - WROUGHT COPPER AN� COPPER ALLOY SOLDER-JOINT PRESSURE FfRINGS;
2013.
�. ASME B31.9 - BUILDING SERVICES PIPING 2014.
E ASTIA B32 - STAN�ARD SPECIFlCATION PoR SOL�ER IAETAL; 2008 (REAPPROVED 2014).
F. ASTIA B88 - STAN�ARD SPECIRCATION FOR SEAMLESS COPPER WATER TOBE; 2016.
G. ASTM B88M - STANDARD SPECIFlCiION FOR SEAMLESS COPPER WATER TUBE (MEiRIC); 2016-
H. ASTM B813 - 4ANDARD SPECIRCATION FOR LIQUID AND PASTE FLU%ES FOR SOLDERING OF
COPPER AN� COPPER ALLOY iUBE 2016.
I. ASTM B828 - STANDARD PRACiICE FOR MAKING CAPILURY JOINTS BY SOLDERING OF COPPER
AND COPPER ALLOY iUBE AND FlTfINGS; 2016.
J. ASTM �1785 - S7AN�ARD SPECIFICATION FOR POLY(VINYL CHLORIDE) (WC) PIAS�IC PIPE,
SCHEDULES 40, 80, AN� 12q 2015, WITH EDITORIAL REVISION (2018).
K. nsrM o2za� - s�nNoneo saeaFicnnoN Foa ao�v (viNn eN�oeioe) (Pve)
PRESSURE-RATED PIPE (SDR SERIES); 2015.
L ASTM D2466 - STANDAR� SPECIFICATION FOR POLY(VINYL CHLOkI�E) (PVC) PIASTIC PIPE
FITfINGS, SCHEDULE 4q 2017.
IA. ASTIA D2564 - STANDAR� SPECIFlCATION FOR SOLVENT CEIAENTS FOR POLY(VWYL CHLORI�E)
(PVC) PUSTIC PIPING SYSiEMS; 2012.
N. ASTM �2855 - STAN�ARD PRACTICE FOR THE 7W0-STEP (PRIMER & SOLVENT CEMENT)
n��rHoo oF doiNiNc ao�r (viNr� cH�oeioe) (Pvc) oe cH�oeiNnTeo Po�v (viNn cH�oeioE)
(CPVC) PIPE AND PIPING COMPONENTS WITH TAPERED SOCKEiS; 2015.
0. AWWA Cfi51 - DISMFECTING WATER MAINS; 2014.
P. CISPI J01 - SiANDARD SPECIFlCATION FOR HOBLE55 CAST IRON SOIL PIPE AND FITiINGS FOR
SANITARY AND STORM DRAIN, WASiE AND VENT PIPING APPLICATIONS; 2009 (REVISED 2012).
Q. CISPI 310 - SPEGFICATION FOR COUPLING FOR USE IN CONNECTION WITH HUBLESS CAST
IRON SOIL PIPE AND FlTfINGS FOR SANITARY AND STORM DRAIN, WASiE, AND VENT PIPING
� �
aaP�canoNs zoii e�vseo zoi2.
( )
R. MSS SP-58 � PIPE HANGERS AND SUPPORTS - MATERIALS �ESIGN MANUFACTURE
SELECTION, APPLICATION, AN� INSTALLATION; 2009.
S. NSF 61 - DRINKING WATER SYSrEM COMPONENTS - HFALTH EFFECTS�, 2017.
T. NSF 372 - �RINKING WATER SYSTEM COMPONENTS - LFA� CONTENT; 2�16.
1.04 QUALIiY ASSURANCE
A. PERFORM WORK IN ACWR�ANCE WITH APPLICABLE WDES.
B. VALVES�. �IANUFACTURER'S NAME AND PRESSURE RATMG MARKEO ON VALVE BODY.
C.IDENTIF" PIPE WITF MARKING INCWDING SIZE, ASTM MATERIAL CIASSIFlCATION, ASTM
SPEC FlCATION, FCTABLE WAF_R CERTIRCATION, WATER PRESSORE RATING.
1.05 �ELNER°, STOFAG-, ANO HANDLMG
A. PROVCE TEMPORARY ENO CAPS AND CLOSURES ON PIPING AND FlTfINGS. MAINTAIN IN PUCE
U�TL INSTALUTION.
B. PROF_CT PIPMG SYSTEMS FROM ENTRY OF PoREIGN MATERIALS BY TEMPORARY COVERS,
CONPET NG SECTIONS OF THE WORN, AN� ISOLATING PARTS OF COMPLETED SYSTEM.
1.06 FlE D CONDITIONS
A. �C NOT INSTALL ONDERGROUND PIPING WHEN BE��ING IS WET OR FROZEN.
PART 2 PRO�JCTS
201 GENERAL REOUIREMENTS
A. POTABLE WATER SUPPLY SYSTEMS: PROVI�E PIPMG, PIPE FlTfINGS, AN� SOL�ER AN� FWX
QF USED), THAT COMPLY WITH NSF 61 AND NSF 372 FOR MA%IMUM LEAD COMENT; IABEL
PIPE AND FlTTINGS.
2.02 SANRARY SEWER PIPING, UNDERGROUND
A. CAST IRON PIPE CISPI J07, HUBLESS, SERVICE WEIGHT.
L FlTfINGS: CASi IRON.
2. JOINTS: CISPI 310, NEOPRENE GASKETS AND STAINLESS SiEEL CUMP-AND-SHIELD
ASSEMBLIES.
2.03 SANRARY SEWER PIPING, ABOVE GRADE
A. PVC PIPE ASTM D1785 SCHEDULE 40, OR ASTM D2241 SDR 26 WIiH NOi LE55 THAN 150
P51 (1 034 KPA) PRESSURE RATING.
1. FITfINGS: ASTM �2466, PVC.
2. JOINTS SOLVENT WEL�ED, WITH AAM D2564 SOLVENT CEMENT.
2.04 �OMEAIC WATER PIPING, ABOVE GRA�E
A. COPPER TUBE ASTM B88 (ASTM B88M), NPE K(A), �RAWN (H).
1. FITfINGS: ASME B16.18, CAST LbPPER ALLOY OR ASME B1fl22, WROUGHT COPPER AN�
BRONZE.
2 JOINTS: ASTM B32, ALLOY SN95 SOL�ER.
205 PIPE HANGERS AN� SUPPORTS
B. PROVIDE HANGERS AN� SUPPORTS THAT COMPLY WITH MSS SP-58.
1. IF NPE OF HANGER OR SUPPORT FOR A PARTICULAR SITUATION IS NOT IN�ICATE�, SELECT
APPROPRIATE iYPE USING MSS SP-58 RECOMMEN�ATIONS.
2 OVERHEAD SUPPORTS: INDIVI�UAL STEEL R0� HANGERS ATfACHED TO STRUCTURE OR TO
TRAPEZE HANGERS.
3. TRAPEZE HANGERS�. WEL�ED STEEL CHANNEL FRAMES ATfACHE� TO STRUCTURE.
4. VERTICAL PIPE SUPPORT�. STEEL RISER CIAIAP.
5. FLOOR SUPPORTS: CONCREfE PIER OR STEEL PE�ESTAL WITH FLOOR FLANGE�, FIXNRE
ATfACHMENT.
B. PWMBING PIPING - DRAIN, WASTE, AN� VENT:
7. HANGERS FOR PIPE SIZES 1�2 INCH (15 MM) TO 7-7�2 INCHES (40 MM)'. MALLEABLE
IRON, ADJOSTABLE SWNEL, SPLIT RING.
2. HANGERS PoR PIPE SIZES 2 WCHES (50 MM) AND OVER: CARBON STEEL, ADJUSTABLE,
CLEV15,
3. WALL SUPPORT FOR PIPE SIZES TO 3 INCHES (80 MM): CAST IRON HOOK.
4. FLOOR SUPPORT: CAST IRON ADJUSTABLE PIPE SADDLE, LOCK NUT, NIPPLE, FLOOR
FLANGE, AND WNCREfE PIER OR STEEL SUPPORT.
C. PWMBING PIPING - WATER:
1. HANGERS FOR PIPE SIZES 1/2 INCH (15 MM) TO 1-1/2 INCHES (40 MM)�. MALLFABLE
IRON, A�Jl1STABLE SWNEL, SPLIT RMG.
2. HANGERS FOR COLD PIPE SRES 2 INCHES (50 MM) AND OVER: CARBON STEEL,
ADJUSiABLE, CLEV6.
3. HANGERS FOR HOT PIPE SIZES 2 WGHES (50 MM) TO 4 INCHES (100 MM): CARBON
SiEEL, ADJUSiABLE, CLEVIS.
4. WALL SUPPORT FOR PIPE SIZES TO 3 INCHES (80 MM): CAST IRON HOOK.
5. FLOOR SUPPORT FOR COLD PIPE: CAST IRON A�JUSTABLE PIPE SAODLE, LOCK NUT,
NIPPLE, FLOOR FLANGE, AND CONCREfE PIER OR S7EEL SUPPORT.
206 MANUFACTURED SLEEVE-SEAL SYSTEMS
A. MANUFACTURER3
7. THE MEfRAFLER COMPANY; MEfRASEAL: WWW.MEfRAFLFX.COM/kSLE.
B. MODUNR/IAECHANICAL SEAb.
1. SYNTHETIC RUBBER IMERLOCKING LINKS CONiINUOUSLY FlLL ANNUUR SPACE BETWEEN
PIPE AND WALL/CASING OPENING.
2 PROVIDE WATERTIGHT SEAL BEfWEEN PIPE AN� WALL/CASING OPENING.
3. EUSiOMER ELEMENT SIZE AND MATERIAL IN ACCORDANCE WITH IAANUFACTURER'S
RECOMMENDATIONS.
4. GUSS REWFORCED PLASTIC PRESSURE END PLATES.
2.07 RELIEF VALVES
A. PRESSURP.
1. MANUFACTURERS:
A CLA-VAL CO'. WWW.CIA-VALCOM.
B. WATiS REGUTATOR COMPANY: WWW.WATiSREGULATOR.COM.
2. ANSI Z2122, AGA CERTIFlED, BRONZE BODY, iEFLON SEAT, STEEL STEIA AND SPRINGS,
AUTOMATIC, DIRECT PRESSURE ACTUATED.
B. TEIAPERATURE AND PRESSURE
1. MANUFACTURERS:
A. CLA-VAL C0: WWW.CIA-VALCOM.
B. WATiS REGUTATOR COMPANY: WWW.WATiSREGULATOR.COM.
2. ANSI Z2122, AGA CERTIFlED, BRONZE BODY, TEFLON SEAT, STAINLE55 4EEL STEM AND
$PRINGS, AUiOMATIC, DIRECT PRESSURE ACTUATED, TEMPERATURE RELIEF MAXIMUM 210
DEGREES F(98.9 DEGREES C), CAPACItt ASME BPVC-N CERTIFlED AND IABELLE�,
PART 3 EXECUTION
3,01 EXAMINATION
A, VERIFY THAT EXCAVATIONS ARE TO REQUIRED GRADE, DRY, AND NOT OVER-ExCAVATED.
3,02 PREPARATION
A, REAM PIPE AND TUBE ENDS. REMOVE BURRS- BEVEL PLAW END FERROUS PIPE.
B, REMOVE SCALE AND DIRT, ON INSI�E AND OUTSIDE, BEFORE ASSEMBLY.
G PREPARE PIPING CONNECTIONS TO EQUIPMENT WITH FIANGES OR UNIONS.
3,03 INSTALLATION
A.INSTALL IN ACCOFDANCE WITH MANUFACTUREF'S INSTkUCTIONS.
B. PROVI�E NON-CON�UCTING DIELECTRIC CONNECTIONS WHEREVER JOINTMG �ISSIMILAR MEfALS.
C. ROUTE PIPING IN ORDERLY MANNER AND MAINTAIN GRA�IENT. ROUTE PARALLEL AN�
PERPENDICULAR TO WALLS.
D.INSTALL PIPING TO MAINTAIN HEADROOM, WNSERVE SPACE, AN� NOT INTERFERE WITH USE OF
SPACE.
E. GROUP PIPING WHENEVER PRACTICAL AT COMMON ELEVATIONS.
F. INSTALL PIPING TO ALLOW FOR EXPANSION ANO CONTRACTION WITHOUT STRESSING PIPE,
JOINTS, OR CONNECTED EQUIPMENT. REFER TO SECTION 22 �516.
G. PROVIDE CLEARANCE IN HANGERS ANO FROM STRUCTURE AN� OTHER EQUIPMENT FOR
INSTALLATION OF INSUlATION ANO ACCESS TO VALVES AND FITfINGS.
H. PROVI�E AWESS WHERE VALVES AN� FITfINGS ARE NOT EXPOSED.
1. COOR�INATE SIZE AN� LOCATION OF ACCESS �OORS WITH SECTION OS 3100.
I. INSTALL VENT PIPING PENEfRAiING ROOFED AREAS TO MAINTAIN INiEGRIiY OF ROOF
ASSEMBLY.
J. PROVI�E SUPPORT FOR UTILIIY MEfERS IN ACWR�ANCE WITH REQUIREMENTS OF UTWiY
COMPANIES.
K.INSTALL VALVES WITH STEMS UPRIGHT OR HORIZONTAL, NOT INVERTED. REFER TO SECTION 22
0523.
L COPPER PIPE ANO TUBE�. MAKE SOLDERED JOINTS IN ACCOROANCE WITH ASTM B828, USING
SPECIFIEO SOLDER, AND FWX MEEfING ASTM B813; IN POTABLE WATER SYSiEMS USE FWX
ALSO COMPLYING WITH NSF 61 AN� NSF 372.
M. PVC PIPE�. MAKE SOLVENT-WELDED JOINTS IN ACCORDANCE WITH ASTM 02855.
N. SLEEVE PIPES PASSING THROUGH PARTITIONS, WALLS AN� FLOORS.
0. PIPE HANGERS AND SUPPORTS:
1. INSTALL IN ACCOkDANCE WITH ASME B31.9.
2 PUCE HANGERS WITHIN 12 INCHES (300 MM) OF EACH HORIZONTAL ELBOW.
J. WHERE SEVERAL PIPES CAN BE INSTALLED IN PARALLEL AND Ai SAME ELEVAiION, PROVIDE
MULTIPLE OR TRAPEZE HANGERS.
P. MANUFACTURED SLEEVE-SEAL SYSiEMS:
1. INSiALL MANUFACTURED SLEEVE-SEAL SYSTEMS IN SLEEVES LOCATED IN GRADE SUBS AN[
EkTERIOR CONCREfE WALLS AT PIPING ENTRANCES INTO BUILDWG.
2 PROVIDE SEALING ELEMENTS OF THE SIZE, QUANTItt, AND ttPE REQUIRED FOR iHE PIPING
AND SLEEVE INNER DIAIAETER OR PENEfRATION DIAMEfER.
J. LOCATE PIPING IN CENTER OF SLEEVE OR PENETRATION.
4- INSiALL FlELD ASSEMBLED SLEEVE-SEAL SYFEM C0IAPONENiS IN ANNUIHR SPACE
BE7VJEEN SLEEVE AND PIPING.
5. TIGHTEN BOLiING FOR A WATER-TIGHT SEAL
6. INSTALL IN ACWRDANCE WITH MANUFACTURER"S RECOMMENDATIONS.
3.04 APPLICATION
A.INSTALL UNIONS OOWNSTREAM OF VALVES AND AT EOUIPMENT OR APPARATUS CONNECTIONS.
B.INSTALL BRASS MALE MAPTERS EACH SI�E OF VALVES IN COPPER PIPE� SYS�EM. SOLDER
ADAPTERS TO PIPE
C.INSTALL BALL VALVES FOR SHUT-OFF AND TO ISOIATE EQUIPMENT, PART OF SYSTEMS, OR
VERTICAL RISERS.
D.INSTALL BALL VALVES FOR THROTfLING, BYPASS, OR MANUAL FLOW WNTROL SERNCES.
3.05 IDLERANCES
A. �RAINAGE PIPING ESTABLISH WVERT ELEVATIONS WITHIN 1/2 INCH (10 MM) VERTICALLY OF
LOCATION INDICATED AND SLOPE TO DRAIN AT MINIMUM OF 1/4 INCH PER FOOT (1:50)
SLOPE.
B. WATER PIPING: SLOPE AT MINIMUM OF 1/J2 INCH PER FOOT (1:400) AND ARRANGE TO
DRAIN AT LOW POINTS.
3.06 DISINFECTION OF DOMESTIC WATER PIPING SYSTEM
A. PRIOR TO STARTING WORK, VERIFY SYSTEM 6 WMPLEfE, FWSHE� AN� CLEAN.
B.INJECT DISINFECTANT, FREE CHLORINE IN LIQUI�, POWDER, TABLEf OR GAS FORM,
THROUGHOUT SYSTEM TO OBTNN 5� TO 80 MG�L RESIDUAL.
C. BLEE� WATER FROM OUTLEfS TO ENSURE DISTRIBUTION ANO TEST FOR �ISWFECTANT
RESIOUAL AT MINIMUM 15 PERCENT OF OUTLEfS.
�. MAINTNN �ISMFECTANT M SYSTEM FOR 24 HOURS.
E.IF FlNAL DISWFECTANi RE9DUAL TESTS LESS THAN 25 MG/L, REPEAT TREAiMENT.
E FWSH DISWFECTANT FROM SY4EM UNTIL RESIDUAL EQUAL TO THAi OF MWMING WATER OR
1.0 MG/L.
G, TAKE SAMPLES NO SOONER THAN 24 HOURS ARER FLUSHING, FR01A 10 PERCENT OF
OUTLEiS AND FROM wATER ENTRY, AND ANALttE IN ACCORDANCE wITH AWWA C651,
3.07 SCHEDULES
h PIPE HANGER SPACING:
1. METAL PIPING:
0. PIPE SIZE: 1/2 INCHES (15 MM) TO 1-1/4 INCHES (32 MM):
1) MAXIMUM HANGER SPACING: 6S R(2 M).
2) HANGER ROD DIAMEiER: 3/8 INCHES (9 MM).
B. PIPE SIZE: 1-1/2 INCHES (40 MM) TO 2 INCHES (50 MM):
1) MAXIMUM HANGER SPACING: 10 Ff (3 M).
2) HANGER ROD DIAMEiER'. 7/8 INCH (9 MM).
C, PIPE SIZE: 2-1/2 INCHES (65 MM) TO J WCHES (75 MM):
1) MAXIMUM HANGEk SPACING: 10 FT (3 M).
z) HnNcea eoo oinM�ree�. i�z iNCH (i3 n�n�).
2 PLASTIC PIPING.
A. ALL SRES:
1) MAXIMUM HANGER $PACING: 6 R(1.8 M).
2) HANGER ROD DIAMETER: 3/B INCH (9 MM).
SECTION 22 1006
PLUMBING PIPING SPECIALTIES
PART 1 GENERAL
1.01 SECTION INCLUDES
A. CLEANOUTS.
B. WATER HAMMER ARRESTORS.
C, MIkING VALVES.
1.02 REFERENCE STANDAR�S
A. NSF 61 - DRINKING WATER SYSTEM COMPONENTS - HEALTH EFFECIS; 2�17.
B. NSF 372 - �RINKING WATER SYAEIA COMPONENTS - LEAD CONTENT; 2016.
C, P�I-WH 201 - WATER HAMMER ARRESTERS; 2010.
1.03 OUALIIY ASSURANCE
A. MANUFACTURER QUALIFlCATIONS WMPANY SPECIALIZING IN MANUFACTURING THE PRODUCTS
SPECIFIED IN THIS SECTION WITH NOT LESS THAN THREE YEARS DOCUMENTED EXPERIENCE.
1.04 DELIVERY, SiORAGE, AND HANDLING
A ACCEPT SPECIALTIES ON SITE IN ORIGINAL FACTORY PACKAGING. INSPECT FOR DAMAGE
PART 2 PRODUCTS
201 GENERAL REQUIREMENTS
A SPEdALTIES IN POTABLE WATER SUPPLY SYSTEMS PROVIDE PRODUCTS THAT COMPLY WITH
NSF 61 AND NSF pp FOR MAXIMUM LEAD CONTENT.
2.02 CLEANOUTS
A. MANUFACTURERS:
1. JAY R. SMITH MANUFACTURING COMPANY: WWWJAYRSMITH.COM.
2. JOSAM COMPANY: WWW.JOSAM.COM.
3. ZURN INDUSTRIES, LLQ WWW.ZURN.COM.
B. CLEANOUTS AT INTERIOR FINISHE� FLOOR AREAS (CO-3):
1. UCOUERED CAST IRON BODY WITH ANCHOR FIANGE, REVERSIBLE CIAMPING WIlAR,
THRFA�ED TOP ASSEMBLY, AND ROUND GASKEfE� SCORE� COVER IN SERNCE AREAS AND
ROUN� GASKEfE� DEPRESSED COVER TO ACCEPT FLOOR FINISH IN FINISHE� FLOOR AREAS.
C. CLEANOUTS AT INTERIOR FlNISHED WALL AREAS (CO-4):
L LME IYPE WITH IACQUERE� CAST IRON B00Y AND ROUND EPo%Y COAiE� GASKETED
CWER, AND ROUND STAMLESS STEEL ACCESS COVER SEWRED WITH MACHWE SCREW.
D. CLEANOUTS Ai IMERIOR UNFlNISHED ACCESSIBLE AREAS (CO-5): CnIKFf] OB iHRFnoFo
ttPE. PROVIDE BOLTED STACK CLEANOUTS ON VERTICAL RAINWATEH IMI)hRS.
2-0.5 WAiER HAMMER ARRESTORS
0. MANUFACTURERS:
1. JAY R. $MITH IAANUFACiURING COMPANY: WWWJAYRSMIiFS.OM.
2. WATfS REGUUTOR COMPANY, A PARi OF WATfS WATER 1tCF�OLO61t5:
WWW.wATfSREGULniOR.COM.
A ZURN INDUSTRIES, LLC: WWW.ZURN.COM-
B. WAiER HAMMER ARRESTORS:
1. STAINLESS 4EEL CONSiRUCT10N, BELLOwS ttPE SIZED IN ACCORDANCE WITH PDI-WH 2O1,
PRECHARGED SUITABLE FOR OPERATION IN TEMPERATURE RANGE MINUS 100 i0 300
DEGREES F(MINUS 73 TO 149 OEGREES C) AND MA%IMUM 250 P51 (1700 KPA) WORKING
PkESSURE.
204 MIHING VALVES
A. THERMOSTATIC MIHING VALVES:
1. MANUFACTURERS:
A. HONEYVJELL INTERNATIONAL INC: YOURHOME.HONEYWELLCOM.
B. LEONARD VALVE COMPANY: WWW.LEONARDVALVE.COM.
2 VALVE: CHROME PIATED CAST BRASS BO�Y, STAMLESS STEEL OR COPPER ALLOY
BELLOWS, INTEGRAL TEMPERATURE A�JUSTMENT.
3. ACCESSORIES.
A. CHECK VALVE ON MLEfS.
B. VOWME WNTROL SHUT-OFF VALVE ON OUTLEf.
G STEM THERMOMETER ON OUTLET.
D. STRAINER STOP CHECKS ON MLEfS.
PART 3 EXECUTION
3.01 INSTALlATION
A.INSTALL IN ACCOR�ANCE WITH MANUFACTURER'S INSTRUCTIONS.
B. EXTEN� CLFANOUTS ID RMSHE� FLOOR OR WALL Sl1RFACE WBRICATE THREADED CLFANOUT
PWGS WITH MIHTURE OF GRAPHITE AN� LINSEEO OIL ENSURE CLFARANCE AT CLEANOUT FOR
ROD�ING OF DRAINAGE SYSTEM.
C.INSTALL FLOOR CLFANOOTS AT ELEVATION TO ACCOMMO�ATE RNISHE� FLOOR.
INSTALL APPROVED POTABLE WATER PROTECTION DEVICES ON PWIABING LWES WHERE
CONTAMINATION OF �OMESTIC WATER MAY OCCUR; ON BOILER FEED WATER LMES, JANITOR
SECTION 22 4000
PLUMBING FlXTURES
1.01 SECTION INCLUDES
A. RHC SINK REFER PLUMBING DRAWINGS FOR SPECIFlCATIONS.
1A2 REFERENCE STANDARDS
A. AOA STAN�ARPS - AMERICANS WITH �ISABILITIES ACT (ADA) STANDARDS FOR ACCESSIBLE
DESIGN; 201�.
B. ASME A712.18.9 - PROTECTORS/INSUTATORS FOR EXPOSE� WASTE AND SUPPLIES ON
ACCESSIBLE FlHTURES; 2011.
C. ASTM C1822 - STANOARD SPECIFlCATION FOR INSOIATING COVERS ON ACCESSIBLE IAVATORY
PIPING 2015.
D. ASHRAE STD 18 - MEfHODS OF TESTING FOR RATMG DRINKING-WATER COOLERS WITH
SELF-CONTAME� MECHAWCAL REFRIGERATION�, 2013.
E. ASME A712.fi.1M - SUPPORTS FOR OFF-THE-FLOOR PWMBING FIXTl1RE5 FOR PUBLIC USE;
1997 (REAFFIRMED 2017).
F ASME An2.18.1 - PLUMBING SUPPLY FlTiINGS; 2012.
G. ASME A112.192 - CERAMIC PLUMBING R%TURES; 2013.
H. ASiM EB4 - STANDARD TE4 MEiHOD FOR SURFACE BURNING CHARACiERISTICS OF BUILDING
MATERIALS; 2018.
I. ICC Ai V.i - ACCESSIBLE AN� USABLE BUILDINGS AND FACILI➢E5; 2017.
J. NSF 61 - DRINKING WATER SYSiEM COMPONENTS - HEALTH EFFECTS; 2017.
K. NSF 372 - DRINKING WATER SYSTEM COMPONENiS - LEAD COMENi; 2016.
1.03 QUALItt ASSURANCE
A. MANUFACTURER �VALIRCAilONS: COMPANY SPECIALIZING IN MANUFACTURING THE iYPE OF
PRODUCiS SPECIFlED IN THIS SECiION, WIiH MINIMUM THREE YEARS OF DOWMEME�
EXPERIENCE.
7.04 REGULATORY REOUIREMENiS
A. PRODUCTS REQUIRING ELECTRICAL CONNECiION: LISTED AND CIASSIFlED BY UNDERWRIiERS
LABORAiOPoES MC. AS SUIiABLE FOR THE PURPOSE SPEQFlED AND INDICATED.
PARi 3 EREWTION
3.01 EXAMINATION
B. VERIFY THAT WALLS AND FLOOR FIWSHES ARE PREPARED AND READY FOR INSTALLATION OF
R%TURES.
C. VERIFY iHAT ELECTRIC POWER IS AVAILABLE AND OF THE CORRECi CHARACTERISTICS.
3.02 PREPARATION
A. ROUGH-M FIxiURE PIPWG CONNECilONS IN ACCORDANCE WITH IAINIMUM SRES INDICATED IN
Fl%TURE ROUGH-IN SCHEDULE FOR PARTICUU+R FIXTURES.
3.03 INSTALLATION
A. INSTALL EACH FIkTURE WITH TRAP, EASILY REMOVABLE FOR SERVIqNG AND CLEANING.
B. PROVIDE CHROIAE PIATED RIGI� OR FLE%IBLE SUPPLIES i0 FlXiURES WIiH LOOSE KEY STOPS,
REDUCERS, AND ESCUTCHEONS.
C.INSTALL COIAPONEMS LEVEL AND PLUMB.
D.INSTALL AND SECURE FlNTURES IN PIACE WITH WALL SUPPORiS AND BOLTS.
E. SOLIDLY ATfACH WATER CLOSETS TO FLOOR WITH lAG SCREWS. LEAD FIASHWG 6 NOT
IMENDED HOLD FIXTURE IN PIACE.
3.04 ADJUSTING
A. ADJUST SiOPS OR VALVES FOR INTEN�ED WATER FLOW RATE TO FIXTURES WITHOUT
SPlASHING, NOISE, OR OVERFLOW.
3.05 CLEANING
A. CLEAN PLUMBING FlXTURES AND EOUIPIAENT.
3.Ofi PROTECTION
A. PROTECT INSiALLED PRODUCTS FROM DAMAGE DUE TO SUBSEOUENT CONSiRUCT10N
OPERATIONS.
B. DO NOT PERMIi USE OF Fl%TURES BY CONSiRUCTION PERSONNEL.
C. REPAIR OR REPLACE DAMAGED PRODUCTS BEFORE DATE OF SUBSiANTIAL COMPLETION.
r4��
harmac n
a y
HUB/ADA/SSSI/ACO
STORE NUMBER 01367
13090 PETTIGRU DR.
CARMEL, IN. 46032
CAPCODE: (90/113/88/114)
CS PRo,IECT NUMBER 138457
ARCHITECT OF RECORD�
i-1
U
CONSULTANT ENGINEER�
CONSULTANT�
SEAL�
REVISIONS:
04-13-2020
DRAWING BY:
CVS PROJECT MANAGER:
DATE:
JOB NUMBER:
T�T�E:
PERMIT SET
R. McCARTHY
E. ROSARIO
04-13-2020
JCDT19.0397.00
PLUMBING
SPECIFICATIONS
SHEET NUMBER:
�
I�
COMMENTS: