HomeMy WebLinkAbout01367IN_P2PLUMBING FIXTURE PIPING SCHEDULE LME SRES TAG FIXTURE ttPE WAS7E TRAP VENT COLD HOT (e)�-i v�vnroev i i/z. i i�a. i i�z.. ��z. ��z.. s-i siNK i i/z. i i�a. i i�z.. ��z.. _ (_)�vc-i e�creic warea coo�e i i/z' i i/a' i i/z" �/z" - PLUMBING FIXTURE SCHEDULE TAG MANUFACTUkER REMAkKS AN� SPECIFICATIONS SWK & FAUCEf 5_1 FU��ISHED 6Y MODEL �SL-A�A-17519-A-GR STAINLESS SrEEL SWK, 17-1�2"x19"x6", (2) HOLES ON 4" CENTEk, CENTEk RFAR MILLWORK SUPPLIER, DRAIN W/ FAUCEf. INSTALLE� BY PWMBER CHRONOMITE INSTANTANEOUS WATER HFATER: MODEL �SR-20L, TANKLESS ELECiRIC WATER HEATER, FLOW ACTNATED, STAMLESS WH-1, WH-2 �qBORATORIES, INQ 4EEL HEAiING COILS, ONE-4160 WATT, 208 VOLT, SINGLE PHASE, 20 AMP, 7/2" WAiER CONNECTION, fi"H x 9"W x 2-1/2", 80-121 DEGREE F. TEMP. RANGE. WCO-1 J.R. SMITH WALL CLEANOUT: TAPER THREAD PLUG WIiH ROUND COVER. I l IC / / i �� �'�� pharmacyn HUB/ADA/SSSI/ACO STORE NUMBER 01367 13090 PETTIGRU DR. CARMEL, IN. 46032 CAPCODE: (90�113�88�114) CS PRo,IECT NUMBER 138457 I ARCHITECT OF RECORD� r1 LJ I �----�— o � —�4 � � — RHC-1 � —(e)siNu C— ELBOW - TURNED DOWN � ELBOW - TURNED UP TEE - TURNED DOWN � TEE - TURNED UP �� GATE VALVE �O� BALL VALVE �� I WCO WALL CLEANOUT NOTES BY SYMBOL Q POINT OF NEW CONNECiION DN DOWN HW HOi WATER UG UNDER GROUND CW COLD WATER SS SANITARY SEWER CONT. CONTINUAiION V PLUMBING VENT RE REFERENCE NK NECK (E) EX6TMG ENlH ELECTRIC WATER HEATER DEMOLITION NOTES BY SYMBOL (0) � I 1 MANAGER � \ \ ---d�� li � I i `�I JI _�� ��< <�� il �I eno-2�� � � -- !I I I �e � �� I I .r �� <i � I �I' � i i �� �'� � (�91NK �� ��. � I� ��� p' ' 'Up' / �J � II � F—�— lF � \ \ � MENS �� � I16� 0 A (E)IAV� I I (E)EWC , .�.- �i Hn�� " (O"v� �I I'I,� 11 i� WOMENS F� — 1 � � �_. � i � � Fi� fil RELEA5E0 FOR CONSTRIICTI�N � �� Suhjec��ocompliancewithallregula�ions 'll ITIDN PLAN 04 S�a�e antl Local Codes J L City of Carmel r �un��\i lo•rvalM��_ DATE: OH/ZO/2O � _ � �� I 36 ��- II ��� 4 T T � I I �3 S5�—_ --- _— �� — — — — — — — — — — — — — — — — — � _ I ', HWT ������� �.,0 i i ' li i j x � I �E>� ��2��°W�� �z,.ss� aECEiviNc � I' � 1 � . � �. 3�4•�W � WC�� I EMPLOYEE - � — � � � i OS W1-2 � I � 3�4. MENS Oj (E)L-1 '� �,O(�1t-i I WOMENS ���� MANAGER � � (E)4°SS �I I �(Owc-i . I � HALL I �I `(E)2"SS �— — i � i / �` �—'��� / ��h \ \ \ \ � AHU-3 C1� � � 255� wC0-1 � S_1O4 WH O RHC-3 O I` I� o 0 III'� . �Tli �� i u� �� ,_,r, � RHC-2 5-1� � �,• � _ � O L -J n � � RHC wainNc S=� � RHc-i I Irr AHU-1 � �I.' � L1 � � _� .��. �s �z� PLUMBING NEW WORK PLAN � P2 SCALE: 1/4"=1'-0" PLUMBING GENERAL NOTES 1. THE WORK SHALL BE E%ECUTED IN GENERAL CONTRACTOB. PWMBING STRICT CONFORIAItt WITH BASE BUIL�ING CONiRACTOR SHALL BE RESPONSIBLE FOR SPECIFICATION AND WIiH iHE LATESi THEIR LOCAiION. MOUNT SHUT-0FF EDITION OF THE PREVAILING LOCAL 8. VALVES NO HIGHER THAN 17-8" AFF. PLUMBING AND BUILDING CODES AND ALL LOCAL REGUUTIONS iHAT IAAY APPLY. IN g, ALL WORK SHALL BE PROPERLY TESTE�, CASE OF CONFLICT BEfWEEN THE BAUNCE� AND CLFANE�. PROVIDE A ONE CONTRACT DOWMENiS AND A GOVERNING YEAR WARRANiY FROM OATE OF FINAL CODE OR ORDINANCE THE MORE INSPECTION ON ALL PARTS AND LABOR. STRINGENT STANDARD SHALL APPLY. io. ro��ow Poi srnNonRos FOR wnrER 2. ALL PLUMBING WORK SHALL BE FlELD HAMMER ARRESTORS. VERIFIED BY CONTRACTOR AND CAORDINATED WITH ALL OTHER iRADES 11. SANITARY SEWER PIPING SHOWN IS BASE� PRIOR TO DEMOLITION/INSTALLATION. ON OJ25"/Ff FOR 3"-6° & 025"/Ff FOR 2 1/2" OR LESS FOR ALL PIPING. 3. NO CHANGES ARE TO BE MADE IN PWMBING lAYOUT WITHOUT WRITTEN �y_ THE DRAWINGS AND SPECIFlCATIONS ARE PERMISSION BY THE ENGINEER OF PRODUCED REPRESENTING WORK TO BE REWR�. DONE IN ACCORDANCE WITH ALL 4. NO PIPING SHALL RUN EHPQSEO IN APPLICABLE FEDERAL, SiATE AND LOCL SALES OR FINISHE� AREAS. CODES. THE LOCAL CODE AUiHORIN HAS THE AUTHORIIY i0 INiERPRET CODE 5. PWMBING CONTRACTOR SHALL BE REQUIREMEMS IN THEIR JURISDICiION. THESE IMERPREiAT10N5 MAY VAM FROM RESPONSIBLE FOR OBTAINING ALL MFORMATION PRESEMED IN THE NECESSARY PERMITS AN� FOR PAYING DOWMENiS. THE CONTRACTOR SHALL REIATED FEES. INFORM THE OWNER�S REPRESENTATNE 6. INSTALL BALL VALVES ON ALL BRANCH AND THE ARCHITECT-ENGINEER, OF SUPPLY LINES. RECORD, OF THE DIFFERENCES AND SHALL PROCEED WITH THE WORK UPON 7. PROVI�E ACCESS PANELS ON ALL RECEIVING THEIR AGREEMENT WITH THE INACCESSIBLE VANES AN� CLFANOUTS LOCAL CODE AUTHORIiY INTERPREfATION. ACCESS PANELS SHALL BE PROVIDED BY AND VENT PIPING FOR FUTURE CONNECTION. COORDINATE WITH ARCHITECTURAL FOR ALL PATCHING REQUIREMENTS. REMOVE EXISTING ELECTRIC WATER COOLER AN� RHAW FOR Fl1TURE CONNECTION. REfAIN CW, SAN AN� VENT PIPMG FOR FUTURE CONNECTION. COOR�INATE WITH ARCHITECTORAL FOR WALL PATCHING RWUIREMENTS. REMOVE EXISTING SINK COMPLEfE. ISOIATE AN� RETAIN HW AND CW PIPING IN CEILING FOR REUSE. REMOVE WASTE AND VENT PIPING. PWG EHISTING SANITARY BELOW FLOOR. CONTRACTOR SHALL VERIFY IN FIEL� THE LOCATION OF EXISTING PIPING PRIOR TO BEGINNING WORK COOR�INATE WITH ARCHITECTURAL TRADES FOR ALL PATCHING NEW WORK NOTES BY SYMBOL (0) 1. INSTALL Ex15iING LA�ATOM TO ACCESSIBILItt STANDARDS wHERE INDICATED. REUSE HW, CW, SAN AND VENi PIPING AND E%iEND AS NECESSAM FOR A COMPLETE AND OPERATIONAL INSiALLAT10N. INSiALL INSULATION ON DRAIN PIPE AND SUPPLY VALVES. COORDINAiE WITH ARCHITECiURAL TRADES FOR WALL PATCHING REOUIREIAENTS, 2. INSTALL EXIS�ING HIGH/LOW WATER COOLER TO ACCESSIBILItt STAN�ARDS WHERE IN�ICATED. INSTALL NEW CANE TOUCH APRON. SEE ARCHITECTURAL DRAWINGS FOR MOUNTING �IMENSIONS. REUSE CW, SAN, AN� VENT PIPING AN� E%TEND AS NECESSARY FOR A COMPLEfE AND OPERATIONAL INSTALUTION. COOR�INATE WITH ARCHITECTURAL TRADES FOR WALL PATCHING REQUIREMENTS. 3. INSTALL NEW SINK wHERE INDICATED. EXTEND HW AND CW FROIA EXISTING PIPING IN CEILING. CONNECT HW, CW, WASTE PIPING AND VENT AS REQUIRED FOR A COMPLEfE AND OPERATIONAL INSTALLATION. COOR�INATE WITH ARCHIiECTURAL TRADES FOR ALL PATCHING REQUIREMENTS. CONTRACTOR SHALL VERIFY IN FIELD THE ExISiING CONDIilONS AND ExISiING PIPING FOR INSTALLATION PRIOR TO BEGINNING WORK. 4. INSTALL NEW SINK WHERE INDICATED. CONNECT CW, HW, WASTE PIPING AND VENT AS REQOIRED PoR A COMPLETE AND OPERATIONAL INSTALLATION. CONTRACTOR SHALL VERIFY M FlELD THE EXISTING CONDITIONS AND EXISTING PIPING FOR WSTALLATION PRIOR TO BEGINNING WORK COORDINATE WRH ARCHRECTURAL TRADES FOR ALL PATCHMG REQUIREMENTS. 5. SAWWT FLOOR AS REQUIRE� TO ROUTE NEW WASTE PIPING AND WNNECT TO EHISTING. CONTRACTOR SHALL VERIFY W FlELD THE EXISTING WN�ITIONS AND EHISTING PIPING FOR WSTALLATION PRIOR TO BEGINNMG WORK. COORDINATE WITH ARCHITECTURAL TRADES FOR ALL PATCHING REOl11REMENTS. 6. ��p" HW AN� CW DOWN M EHISTING WALL ID 9NN. 1 1/2' WASTE DOWN AND I 1/2" VENT UP. 7. 1/2" CW DOWN IN EXISTING WALL i0 SINK AND INSTANiANE0U5 WATER HEATER. 7 1/2" WASTE DOWN AN� 1 1/Y' VENT UP. 8. INSTANiANE0U5 WATER HEATER ON WALL BELOW COUNTER. 9. ROUTE 1" CONDENSATE DOWN TO MOP SINK. FIRE PROTECTION NOTE: G.C. i0 DETERMWE IF ANY MODIRCATIONS NEED TO BE MADE TO THE E%IS➢NG FIRE PROTECTION SYSTEM IN OR�ER TO COORDINATE YAiH NEW WORK.IF MO�IRCATIONS ARE NWESSARY, GC. SHALL PRONDE DRAWINGS PREPARED BY A LICENSED FlRE PROTECTION CONTRACTOR PoR QTY APPROVAL. THE DRAWMGS AND SPECIFlCATIONS ARE PRODUCED REPRESENTING WORK TO BE DONE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES THE LOCAL CODE AUTHORIiY HAS THE AUTHORIiY TO INTERPREf CODE REQUIREMENTS IN THEIR JURISDICTION. THESE INTERPRETATIONS MAY VARY FROM WFORMATION PRESENTED IN THE DOCUMENTS. THE CONTRACTOR SHALL MFORM THE OWNER'S REPRESENTATIVE AND THE ARCHITECT-ENGWEEER, OF RECORD, OF THE DIFFERENCES AND SHALL PROCEED WITH THE WORK UPON RECEIVING THEIR AGREEMENT WITH THE LOCAL CODE AUTHORITY IMERPRETATION. CONSULTANT ENGINEER� CONSULTANT� SEAL� REVISIONS: 04-13-2020 PERMIT SET DRAWING BY: R. McCARTHY CVS PROJECT MANAGER: E. ROSARIC DATE: 04-13-202( JOB NUMBER: JCDT19.0397.0( TITLE PLUMBING PLANS, NOTES AND SCHEDULES SHEET NUMBER: COMMENTS: P2