HomeMy WebLinkAboutC060.4 - STORM PLAN AND PROFILE 5TRAILBLAZER COURT
JASMINE DRIVE* *
*
*
* * MH-ETM10
MH-ETM09
MH-ETM11
28 LF - 12" RCP @ 0.50%
138 LF - 15" RCP @ 0.60% 328 LF - 15" RCP @ 0.80%
28 LF - 12" RCP @ 0.40%
154 LF - 15" RCP @ 0.25%
SSD. RISER
894.63
SSD. RISER
894.07
SSD. RISER
892.08
6" SSD. 92 LF
6" SSD. 294 LF
6" SSD. 90 LF 6" SSD. 22 LF
SWALE 124 LF @ 1.00%
SWALE 300 LF @ 1.00% SWALE 100 LF @ 1.00%
141 LF - 21" RCP @ 0.59%
865
870
875
880
885
890
895
900
905
910
865
870
875
880
885
890
895
900
905
910
STM 632
T.C. = 894.56
IE: 890.84 (E)
28 LF - 12" RCP
@ 0.50%
STM 633
T.C. = 894.56
IE: 890.70 (W)
IE: 890.60 (E)
138 LF - 15" RCP
@ 0.60%
STM 634
RIM: 893.70
IE: 889.77 (W)
IE: 889.62 (S)
IE: 889.57 (E)
FES 650
21" RCP
IE: 886.00 (W)895.2894.6894.2893.3892.7893.2893.3894.1894.2893.7892.8892.0891.6890.4895.06894.57894.54894.04893.87894.68893.13892.63892.13891.63891.13891.38891.88888.010+00 1+00 2+00 3+00 4+00 5+00 6+00
8" PVC SAN. MAIN
INV. = 879.33
CROWN = 880.02
328 LF - 15" RCP
@ 0.80%
STM 635
RIM: 891.00
IE: 886.93 (W)
IE: 886.82 (E)
141 LF - 21" RCP
@ 0.60%
37.5" SUMP AND
SNOUT 18R
(SEE DETAIL
05/C8.2)
865
870
875
880
885
890
895
900
905
910
865
870
875
880
885
890
895
900
905
910
154 LF - 15" RCP
@ 0.25%
STM 634
RIM: 893.70
IE: 889.77 (W)
IE: 889.62 (S)
IE: 889.57 (E)893.7893.7893.6893.1894.15894.15896.01895.110+00 1+00
CROWN = 881.66
8" PVC SAN. MAIN
INV. = 880.97
28 LF - 12" RCP
@ 0.40%
STM 638
TC = 894.20
IE: 890.27 (N)STM 639
TC = 894.20
IE: 890.16 (S)
IE: 890.01 (N)
37.5" SUMP AND
SNOUT 18R
(SEE DETAIL
05/C8.2)
870
875
880
885
890
895
900
905
870
875
880
885
890
895
900
905
21 LF - 12" RCP
@ 2.00%STM 636
RIM: 891.80
IE: 888.02 (NE)890.1890.6891.95885.630+00
FES 637
12" RCP
IE: 887.60
37.5" SUMP AND
SNOUT 18R
(SEE DETAIL
05/C8.2)
DRAWING NO.
C6.4
N:\2018\18414\Drawings\ACAD\LD\S04.1\Sheet Drawings\CD\18414_C5.0 UTILITY PLAN.dwg 5/17/2019DESCRIPTIONDATENO. R E V I S I O N SPROJECT NO.:PROJECT MANAGER:DRAWN BY:DESIGNED BY:ORIGINAL ISSUE DATE:18414DECEMBER 14, 2018JORPLDJORCARMEL INDIANASTORM SEWER PLAN & PROFILEESTATES AT TOWNE MEADOWDESCRIPTIONDATE NO. 619 N Pennsylvania StIndianapolis, IN 46204317.423.0690 phonewww.v3co.comKnow what'sbelow.
before you dig. Call
R
KEY MAP
N.T.S.
NOTES:
1. CONTRACTOR TO FIELD VERIFY LOCATION, INVERT,
AND SIZE OF ALL EXISTING UTILITIES PRIOR TO
ORDERING MATERIALS OR BEGINNING UTILITY
WORK. CONTRACTOR TO NOTIFY ENGINEER OF
ANY DISCREPANCIES IMMEDIATELY.
2. UNLESS INDICATED OTHERWISE, FRAME AND OPEN
LID STORM STRUCTURES IN PAVEMENT SHALL BE
NEENAH R-2502 WITH TYPE D LID OR APPROVED
EQUAL, AND FRAME AND CLOSED LID STORM
STRUCTURES IN PAVEMENT SHALL BE NEENAH
R-1772 OR APPROVED EQUAL. FRAME AND OPEN
LID STORM STRUCTURES IN OPEN SPACE SHALL BE
R-4340-B OR APPROVED EQUAL. ALL FRAME AND
GRATES SHALL CONFORM TO LOCAL MUNICIPALITY
REQUIREMENTS.
FRAME AND CLOSED LID STORM STRUCTURES
LOCATED WITHIN AN ACCESSIBLE ROUTE SHALL BE
“NEENAH R-1772 WITH TYPE C LID (OR EQUIVALENT)
WITH PERMA-GRIP SURFACE. DRILL 1 - 1” DIAMETER
LIFT HOLE INSTEAD OF A STANDARD PICK HOLE.”
3. LIGHT POLES SHOWN FOR COORDINATION OR
LOCATION PURPOSES ONLY AND DO NOT
REPRESENT ACTUAL SIZE. SEE PLANS BY SITE
LIGHTING CONSULTANT FOR SITE LIGHTING
INFORMATION.
4. THE STORM SEWER SYSTEM SHALL BE
CONSTRUCTED PER DESIGN SPECIFIED AND AS
APPROVED BY THE CITY OF CARMEL ON THE FINAL
APPROVED CONSTRUCTION PLANS. DEVIATIONS
FROM THE APPROVED DESIGN SHALL ONLY BE
PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR
DIFFICULTY DURING CONSTRUCTION AND WILL
REQUIRE PRIOR FIELD APPROVAL FROM A
DESIGNATED REPRESENTATIVE OF THE CITY OF
CARMEL IN ADDITION TO SUPPLEMENTAL
APPROVAL BY THE DESIGN ENGINEER. AN
EXPLANATION OF ANY SUCH DEVIATION SHALL BE
INCLUDED AS A REQUIREMENT ON
AS-BUILT/RECORD DRAWINGS SUBMITTED FOR
RELEASE OF PERFORMANCE GUARANTEES.
APPROVED DESIGN SLOPES IDENTIFIED AS
GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10
FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL
REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF
CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE.
THE CONTRACTOR IS INSTRUCTED TO AS-BUILT
EACH SECTION OF STORM PIPE AS IT IS BEING
INSTALLED TO ENSURE COMPLIANCE WITH THE
DESIGN PLANS AND AS APPROVED BY THE CITY OF
CARMEL..
08/20/20