HomeMy WebLinkAboutC060.6 - STORM PLAN AND PROFILE 7870 875 880 885 890 895 900 905 870 875 880 885 890 895 900 905 (2) 155 LF - 15" RCP @ 0.22% 893.1891.2891.3890.7890.6885.93890.60891.18887.22882.720+00 1+00 1+71 12" DIP GAS MAIN BOT. PIPE = 886.47 CROWN = 887.57 8" DIP GAS MAIN BOT. PIPE = 887.43 CROWN = 888.18 2.57'STM 651 2'x2' BOX INLET RIM: 885.50 IE: 882.84 (SE)FES 652 & 652A 15" RCP IE: 882.50STM 651A 2'X2' BOX INLET RIM: 885.50 IE: 882.84 (SE) HP PPP HPP P P H P PPP HPP P P H P PPP HPP P P HP PPP HPP P P HP PPP H PPP P HP PPP H PPP P HPP P P H PPP P HPP P P H PPP P HPP P P HPP P P H P PPP H PP PP HP PPP HPP P P HPP P P HPP PP HPP P P H P PPP HPP P P HPP P P HPP P P HP PP P HPP P P HP PPP HP P PP HPP P P 2 X 155 LF - 15" RCP @ 0.22% SSD. RISER=892.78 INV=890.48 6" SSD. 201 LF SSD. RISER=891.28 INV=888.17 6" SSD. 143 LF 0.90% 1.23% HPP PP H PP P P HPP P P H PP P P HPP PP HPP P P HP PPP HPP P P H PPP P HPP P P H P PPP HPP P P HPP P P HPP P P HPP P P H PPP P HPP P P H PPP P HPP P P H PPP P H PP P P HPP P P HP PP P HPP P P HP PPP HPP P P HPP P P HPP P P HPP P P H PPP P HPP P P HPP P P HPP P P HPP P P HPP P P HPP P P H PPP P HPP P P HPP P P HPP P P HPP P P 139 LF - 30" RCP @ 0.30% 22 LF - 30" RCP @ 0.36% 47 LF - 24" RCP @ 0.90% 47 LF - 24" RCP @ 1.23% MH-ETM06 28 LF - 12" RCP @ 23 LF - 12" RCP 2 X 89 LF - 36" RCP @ 0.56% FH 4 VB 8 IN RON 870 875 880 885 890 895 900 905 870 875 880 885 890 895 900 905 886.7886.1885.9887.00892.00888.940+00 1+00 (2) 89 LF - 36" RCP @ 0.56% CROWN = 883.49 8" PVC SAN. MAIN INV. = 882.80 STA:0+38.40 ELEV:892.15 8" WATER MAIN INV = 884.19 FES 624 & 624A 36" RCP IE: 886.50(SE) FES 623 & 623A 36" RCP IE: 886.00(NW) 870 875 880 885 890 895 900 870 875 880 885 890 895 900 885.1885.4888.1888.5888.7882.710+00 1+00 2+00 STM 654 RIM: 885.46 IE: 882.08 (NE) IE: 882.08 (S) 139 LF - 30" RCP @ 0.30% FES 655 21" RCP IE: 882.00(N) 22 LF - 30" RCP @ 0.36% STM 653 SEE DETAIL SHEET C8.3 RIM: 886.40 IE: 882.50 (S) 870 875 880 885 890 895 900 870 875 880 885 890 895 900 888.5884.0886.6883.2888.45884.03886.58883.210+00 1+16 47 LF - 24" RCP @ 1.23% START INV: 884.56 END INV: 883.98 EX. 60 LF - 24" RCP @ 1.23% START INV: 883.98 END INV: 883.25 STM 656 SEE DETAIL SHEET C8.3 RIM: 887.70 IE: 884.56 (SE) 870 875 880 885 890 895 900 870 875 880 885 890 895 900 888.5883.9886.7883.0888.52883.90886.67883.050+00 1+16 47 LF - 24" RCP @ 0.90% START INV: 884.28 END INV: 883.86 EX. 60 LF - 24" RCP @ 0.90% START INV: 883.86 END INV: 883.32 STM 656A SEE DETAIL SHEET C8.3 RIM: 887.70 IE: 884.28 (SE) DRAWING NO. C6.6 N:\2018\18414\Drawings\ACAD\LD\S04.1\Sheet Drawings\CD\18414_C5.0 UTILITY PLAN.dwg 5/17/2019DESCRIPTIONDATENO. R E V I S I O N SPROJECT NO.:PROJECT MANAGER:DRAWN BY:DESIGNED BY:ORIGINAL ISSUE DATE:18414DECEMBER 14, 2018JORPLDJORCARMEL INDIANASTORM SEWER PLAN & PROFILEESTATES AT TOWNE MEADOWDESCRIPTIONDATE NO. 619 N Pennsylvania StIndianapolis, IN 46204317.423.0690 phonewww.v3co.comKnow what'sbelow. before you dig. Call R KEY MAP N.T.S. NOTES: 1. CONTRACTOR TO FIELD VERIFY LOCATION, INVERT, AND SIZE OF ALL EXISTING UTILITIES PRIOR TO ORDERING MATERIALS OR BEGINNING UTILITY WORK. CONTRACTOR TO NOTIFY ENGINEER OF ANY DISCREPANCIES IMMEDIATELY. 2. UNLESS INDICATED OTHERWISE, FRAME AND OPEN LID STORM STRUCTURES IN PAVEMENT SHALL BE NEENAH R-2502 WITH TYPE D LID OR APPROVED EQUAL, AND FRAME AND CLOSED LID STORM STRUCTURES IN PAVEMENT SHALL BE NEENAH R-1772 OR APPROVED EQUAL. FRAME AND OPEN LID STORM STRUCTURES IN OPEN SPACE SHALL BE R-4340-B OR APPROVED EQUAL. ALL FRAME AND GRATES SHALL CONFORM TO LOCAL MUNICIPALITY REQUIREMENTS. FRAME AND CLOSED LID STORM STRUCTURES LOCATED WITHIN AN ACCESSIBLE ROUTE SHALL BE “NEENAH R-1772 WITH TYPE C LID (OR EQUIVALENT) WITH PERMA-GRIP SURFACE. DRILL 1 - 1” DIAMETER LIFT HOLE INSTEAD OF A STANDARD PICK HOLE.” 3. LIGHT POLES SHOWN FOR COORDINATION OR LOCATION PURPOSES ONLY AND DO NOT REPRESENT ACTUAL SIZE. SEE PLANS BY SITE LIGHTING CONSULTANT FOR SITE LIGHTING INFORMATION. 4. THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL.. 08/20/20