Loading...
HomeMy WebLinkAboutC070.0 - WATER PLAN AREA 1HP PPP HPP P P HP PPP HPP P P HP PPP HPP P P HP PP P H SEA Group,Land Su rveyors SEAG rou p, Lan dS urv eyors S EA Gr oup,L and Su rve yors TRAILBLAZER COURT JASMINE DRIVE * * * * * * * * MH-ETM10 MH-ETM09 MH-ETM08 MH-ETM11 MH-ETM07 MH-ETM06 WWWWWWWWWW8" X 8" X 8" TEE FH 2 FH 2 FH 3 VB 1 VB 2 VB 3 FH 4 11.25° BEND 22.50° BEND 22.50° BEND 11.25° BEND 11.25° BEND 22.50° BEND 10 LF - 1" COPPER SERVICE LINE 10 LF - 1" COPPER SERVICE LINE 10 LF - 1" COPPER SERVICE LINE 10 LF - 1" COPPER SERVICE LINE 5 LF - 1" COPPER SERVICE LINE 48 LF - 1" COPPER SERVICE LINE 45 LF - 1" COPPER SERVICE LINE 8 LF - 1" COPPER SERVICE LINE 11 LF - 1" COPPER SERVICE LINE 10 LF - 1" COPPER SERVICE LINE 8 LF - 1" COPPER SERVICE LINE 8 LF - 1" COPPER SERVICE LINE 48 LF - 1" COPPER SERVICE LINE 48 LF - 1" COPPER SERVICE LINE 9 LF - 1" COPPER SERVICE LINE 9 1" COPPER SERVICE LINE 48 LF - 1" COPPER SERVICE LINE 10 LF - 1" COPPER SERVICE LINE 10 LF - 1" COPPER SERVICE LINE 10 LF - 1" COPPER SERVICE LINE 10 LF - 1" COPPER SERVICE LINE 10 LF - 1" COPPER SERVICE LINE 46 LF - 1" COPPER SERVICE LINE 46 LF - 1" COPPER SERVICE LINE 46 LF - 1" COPPER SERVICE LINE 46 LF - 1" COPPER SERVICE LINE 46 LF - 1" COPPER SERVICE LINE VB 4 CONNECTION TO EXISTING 8" WATER MAIN VERIFY CONNECTION TO EXISTING WATER MAIN IN FIELD |VB 5 VB 6 FH 8 FH 1 11.25° BEND 36' BORE UNDERNEATH DRIVEWAY 22.50° BEND 8 IN X 8 IN-INCH DUCTILE IRON 8 IN X 8 IN-INCH DUCTILE IRON 8 IN X 8 IN-INCH DUCTILE IRON 8 IN X 8 IN-INCH DUCTILE IRON 8 IN X 8 IN-INCH DUCTILE IRON 8 IN 8 IN X 8 IN-INCH DUCTILE IRON 8 IN X 8 IN-INCH DUCTILE IRON 8 IN X 8 IN-INCH DUCTILE IRON8 IN X 8 IN-INCH DUCTILE IRON 22.50° BEND 8 IN X 8 IN-INCH DUCTILE IRON 8 IN X 8 IN-INCH DUCTILE IRON 8 IN X 8 IN-I NC H DU C T I LE IRO N Know what'sbelow. before you dig. Call R DRAWING NO. C7.0 N:\2018\18414\Drawings\ACAD\LD\S04.1\Sheet Drawings\CD\18414_C5.0 UTILITY PLAN.dwg 5/17/2019DESCRIPTION DATE NO. R E V I S I O N SPROJECT NO.:PROJECT MANAGER:DRAWN BY:DESIGNED BY:ORIGINAL ISSUE DATE:18414DECEMBER 14, 2018 JORPLDJORCARMEL INDIANAWATER PLAN - AREA 1ESTATES AT TOWNE MEADOWDESCRIPTIONDATE NO. 619 N Pennsylvania StIndianapolis, IN 46204317.423.0690 phonewww.v3co.comKEY MAP N.T.S. AREA 1 FOR CONTINUATION SEE SHEET 7.1WATER TABLE STREET SIZE LENGTH UNIVERSITY COURT 0'-8" 596'-0" JASMINE 0'-8" 651'-0" TOWNE MEADOW DRIVE 0'-8" 2,440 1. For installation of water mains and service lines, see 03/C7.2 for trench details. 2. All water service lines are to be stubbed per plan. The termination of the stub is to be marked with a 4” PVC pipe with a painted blue top. 3. Tracer wire must be installed along all water mains per City of Carmel Utilities Department specifications. 4. Granular backfill must be placed at all water main road crossings per City of Carmel standards. 5. Blue snowplowable raised pavement markers are to be installed at the centerline of the road adjacent to each fire hydrant. 6. All Ductile Iron water mains shall be bedded in sand, from the bottom of the trench to 12" above pipe (see sheet C7.2). 7. All fire hydrants shall be Mueller or American Darling (Safety Yellow, M.A.B. #0433291, Sherwin Williams #F75YP2), open to the right, and have a safety blue stripe around hydrant bonnet from the factory. The hydrant pumper nozzle shall be of one-piece design, compatible with 5" Storz hose coupling. The nozzle shall be an integral part of the fir hydrant and must be furnished by the manufacturer or authorized distributor designated by the manufacturer. Mueller model 290220 for casting and 290221 for cap. Storz adapters will not be accepted. 8. Blue reflective tape must be installed 18" above all water mains. 9. Tracer wire shall be installed with all all water mains. 10. Posi-Caps or the equivalent are required on all water valve installations. NOTE: ALL WATER MAINS SHALL BE DUCTILE IRON AND INSTALLED PER THE CITY OF CARMEL STANDARDS UNLESS OTHERWISE NOTED, ALL WATER MAINS SHALL BE INSTALLED AT A MINIMUM DEPTH OF 54" UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED SHALL BE RELOCATED TO WITHIN ONE FOOT OF THE PROPOSED RIGHT-OF-WAY LINE. Utility inspectors have the authority to make changes in the field if conditions are warranted. NOTES 08/20/20