Loading...
HomeMy WebLinkAboutA102 Roof Plan�f � ; � `•.�� � 1 st Floor Reflected Clg Plan � L SCALE:7/4'. = 1'_0" p z, a, g, I � N � GENERAL CEILING NOTES: 1 Ceiling height designated by benchmark above finished floor (AFF.) 2 Each room to have individual switch located on wall at doorway to room, typical unless noted otherwise. In locations of 2 or more switches in close proximity, switches ar to be consolidated to a gang plate condition. 3 Trades to coordinate [he heigh[ of roof stack vents and condensate lines to allow for ceiling heighis as indicated on the reflected ceiling plan. 4 See RCP plan for ceiling heights. 5 Use level 5 fnish on gypsum wall board on finished ceilings. CEILING NOTES: 1 Provide 1/4" control joint to be: Fry Reglet DRM-50-25-2-PC or equal. Reference detail xlxxx. 2 Align finished faces. 3 Provide air vent in ceiling soffit. Reference M- series dwgs. Center in soffit. 4 All interior walls to be at a height of 10'-0" unless otherwise noted. 5 Reference E-series dwgs. for lighting schedule 6 Camera mounted in sofft north of entry door. Coordinate w/ITforexactlocation. FASTEN HT 12' O C. IN BOTH �IRECTIONS EXTEN� FLASHING MEMBRANE H MINIMUM OF 3" BEVON� METHLFLANGETO NCCOMMO�ATEAMINIMUM iS'HtHI WtLIJtDSEHM MINIMUM THROOGH WALLSCUPPERFLANGE SET IN BEAD OF BUTYL SEALANT WATERPROOFSHEET MFTAI THROUGH scuPVEasEcurzEoro suesranTE IN9WLLFHSTENEF � /f' � PLNTEAMINIMUMOF�" �� 4�� BEYOND SCUPPER [ 4:, � 5 � FLNNGEHN�SPACE� i MAXIMIIM OF 12'HPART E#6NIJ FLASHING MtMBRANE HMINIMUMOF3"9FYON� ��� METHLFLANGETO � NCCOMMO�ATEAMINIMUM / 15" HEAT WELDED SEAM � SEPARATOR SHEET � VAPOR RETARDER/AIR BARRIER BASE SHEET/NNCHOR SHEET � THROUGH WALL SCUPPER VINYL COATED METHL � TAPEftE01N3l1LATION SUMPATPRIMAHY �MEM6RANEFLASHING THROUGHWALL �/ SCUPPERS � VINYLCOATED METAL PATCH REL� MEMBRANE `� INSULATION INSIILATION MALBARRIER �ECK 4NGE corrEk PEOCOR DESIGN GROl1P LLC Archileclure I Project ManagemenL 355 Giry Center �rive Wrmel, Intliana 46032 3177057979 (phane) 3177057980 (faz) 00033126 � s1nTE oF , (/ � \ i _�� � ❑ � � � � � KEY PLAN � Bldg I su�e. rv.s a�nu Noarx Developer. P E D C O R �� ���� DEVELOPMENT CO. Projecf. � L ^, O W L O� � � � N M '�^ � � v , � Z w V — � � � cv V � � J � � O � � .ME reCONSTRUCTION DOCUMENTS Setlssue oate Sheetlssue Date 3/�3I2020 3/13I2020 Drawn By Checketl By Sheet Title' Roof Plan Sheet Number� RELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel `�y,:a���'.�`� �,�:;vaYa/„1��. DATE: 08�Z � �2O � Scupper Detail \✓G / SCALE 3" = 1'-0" 0 3�. s�. y.� �� � Scupper Detail \✓ � J SCALE:3" = 1'-0" o a" s" s" �� ROOF PLAN GENERAL NOTES: 1 Roof Plan A102 references and details the metal stud composition of all parapet walls with a cutting plane of +6'-0" above roof deck. 2 PVC roofng goes up the back side of all parapets U.N.O. ROOF PLAN NOTES: 1 Vent stacks, reference P series drawings. Follow roofng manufacturer's required flashing details for curbs and penetrations 2 Pre-finished metal roof scuppec Ref. dtls. D1l A102 & D2IA702. 3 Plumbing vent. Ref. P-Series drawings. Follow roofng manufacturer's required flashing de[ails for curbs and penetrations 4 Mechanical equipment. Ref. mechanical drawings. Follow roofng manufacturer's required flashing details for curbs and penetrations 5 Polyvinyl-chbride (PVC) , over 5I8" glass-mat water resistant gypsum cover bd., over 4" polysryrene bd. Insulation, and 6 mil. polyethylene vapor barrier & 5/8" glassmat water resistant gypsum substrate bd. 6 Tapered roofng @ 1/2":1' 7 Pre-finished metal roof parapet cap, ref. A3/A303 8 Pre-finished metal downspout. 9 Break in structural roof decking requires change in insulation thickness 10 Roof vents, ref. M-Series sheets 11 Provide crickets at any mechanical curb, typ. 12 PVC membrane Flashing over existing brick veneec. Ref. detail A1/A501. 13 PVC membrane Flashing CMU parapet wall, Ref. detail Bi/A501. ��l O� N � Roof Plan � I SCALE il4" = 7'_0„ p p, q, a, Project Number.