Loading...
HomeMy WebLinkAboutE100.0CEILING WALL FLOOR T COLD AIR RETURN HVAC KEY FLOOR SUPPLY REGISTER WALL SUPPLY REGISTER CEILING SUPPLY REGISTER EXTERIOR WALL EXHAUST VENT THERMOSTAT DRYER BOX G W GAS SHUT-OFF KEY PLUMBING KEY MAIN WATER SHUT-OFF ICE MAKER BOX LAUNDRY BOX FROST PROOF HOSE BIB CLEAN OUT TILE-IN DRAIN FLOOR DRAIN ELECTRICAL KEY REF. OUTLET MICRO.OUTLET DW POWER SUPPLY HOOD VENT POWER SUPPLY GB POWER SUPPLY DIMMER SWITCH SURFACE MOUNT LIGHT FIXTURE 6" RECESSED CAN LIGHT 4" RECESSED CAN LIGHT 6" RECESSED CAN/FAN UNIT EXHAUST FAN ONLY EXHAUST FAN W/ LIGHT WALL MOUNTED SCONCE / LIGHT CEILING FAN LOW VOLTAGE LIGHT SMOKE DETECTOR MOTION SENSOR CEILING SPEAKER LOW VOLTAGE LIGHTING SWITCH GARBAGE DISPOSAL SWITCH COUNTERTOP AIR SWITCH SINGLE POLE SWITCH LOW VOLTAGE TRANSFORMER 220/240V OUTLET EXTERIOR OUTLET GFCI OUTLET 110V OUTLET GAS COOKTOP CLOTHS DRYER OUTLET 4-WAY SWITCH 3-WAY SWITCH NOTE: ALL SWITCHES INSIDE ARE ON DIMMERS LIVING ROOM RE-GRID LIGHTS IN LIVING ROOM INSTALL CEILING FAN INSTALL OUTLET FOR TV WITH LV BOX INSTALL NEW EXTERIOR SCONCES E1E1 E2E2 E3E3 E4E4 E1E1 E2E2 E3E3 E4E4 KITCHEN INSTALL NEW EXTERIOR SCONCES FIX OUTLET OVER-UNDER SWITCH REPLACE PENDANTS RE-GRID ALL LIGHTS IN KITCHEN E1E1 E2E2 E3E3 E4E4 E5E5 E1E1 E2E2 E3E3 E4E4 E5E5 BATHROOM NO ELECTRICAL IN CURRENT SCOPE OF WORKE1E1E1E1 LAUNDRY INSTALL (2) NEW 6" RECESSED CANS OWNER - REINSTALL WASHER/DRYER HOOKUP CHECK BREAKER FOR UPSTAIRS OUTLET IN MASTER BATH E1E1 E2E2 E3E3 E1E1 E2E2 E3E3 DINING (NEW OFFICE) ADD GRID OF (4) RECESSED LIGHTS CAP OLD LIGHT FIXTURE ADD 2 ADDITIONAL OUTLETS IN OFFICE E1E1 E2E2 E3E3 E1E1 E2E2 E3E3 ENTRY INSTALL NEW LIGHT FIXTUREE1E1E1E1 OFFICE NO ELECTRICAL IN CURRENT SCOPE OF WORKE1E1E1E1 ACREY RESIDENCEInterior Remodel13132 Brookshire PkwyCarmel, IN 46033Date:Revision: 9 SHEET OF 16 SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited. PROPOSED M.E.P PLAN NOTES - FIRST FLOOR SCALE: 1/2" = 1'CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462208/10/2020 DATE: GENERAL M.E.P NOTES HVAC Contractor is responsible for engineering calculation necessary for correct sizing of new equipment and ductwork being supplied, fabricated and installed for the project. HVAC ductwork being installed in unconditioned areas to be insulated and sealed per current Building Code Standards. HVAC contractor to start, test, and balance any new equipment and ductwork to assure proper operation of new systems. Final plumbing materials selected may have an affect on the final Plumbing Material and Installation Budgets. Owners understand that if additional plumbing, electrical or ductwork is found in walls being deleted that is not included on the plans there will be a Change Order during construction to relocate as necessary. Owners understand that during mechanical rough-ins there will be times when the water service will be shut off to areas in the home. Plumbing and Lighting fixtures supplied by Owner will not be warrantied by Custom Living Plumbing and Lighting fixtures supplied by Owner must be selected and on-site prior to start of mechanical rough-ins. [PRINTS TO SCALE IF PRINTED ON 24" X 36" ] DESIGNER: EMMA MAXWELLE: emma@customlivingusa.comC: 574.292.244108/21/20 David Rutti