HomeMy WebLinkAboutE100.0CEILING
WALL
FLOOR
T
COLD AIR RETURN
HVAC KEY
FLOOR SUPPLY REGISTER
WALL SUPPLY REGISTER
CEILING SUPPLY REGISTER
EXTERIOR WALL EXHAUST VENT
THERMOSTAT
DRYER BOX
G
W
GAS SHUT-OFF KEY
PLUMBING KEY
MAIN WATER SHUT-OFF
ICE MAKER BOX
LAUNDRY BOX
FROST PROOF HOSE BIB
CLEAN OUT
TILE-IN DRAIN
FLOOR DRAIN
ELECTRICAL KEY
REF. OUTLET
MICRO.OUTLET
DW POWER SUPPLY
HOOD VENT POWER SUPPLY
GB POWER SUPPLY
DIMMER SWITCH
SURFACE MOUNT LIGHT FIXTURE
6" RECESSED CAN LIGHT
4" RECESSED CAN LIGHT
6" RECESSED CAN/FAN UNIT
EXHAUST FAN ONLY
EXHAUST FAN W/ LIGHT
WALL MOUNTED SCONCE / LIGHT
CEILING FAN
LOW VOLTAGE LIGHT
SMOKE DETECTOR
MOTION SENSOR
CEILING SPEAKER
LOW VOLTAGE LIGHTING SWITCH
GARBAGE DISPOSAL SWITCH
COUNTERTOP AIR SWITCH
SINGLE POLE SWITCH
LOW VOLTAGE TRANSFORMER
220/240V OUTLET
EXTERIOR OUTLET
GFCI OUTLET
110V OUTLET
GAS COOKTOP
CLOTHS DRYER OUTLET
4-WAY SWITCH
3-WAY SWITCH
NOTE: ALL SWITCHES INSIDE ARE ON DIMMERS
LIVING ROOM
RE-GRID LIGHTS IN LIVING ROOM
INSTALL CEILING FAN
INSTALL OUTLET FOR TV WITH LV BOX
INSTALL NEW EXTERIOR SCONCES
E1E1
E2E2
E3E3
E4E4
E1E1
E2E2
E3E3
E4E4
KITCHEN
INSTALL NEW EXTERIOR SCONCES
FIX OUTLET
OVER-UNDER SWITCH
REPLACE PENDANTS
RE-GRID ALL LIGHTS IN KITCHEN
E1E1
E2E2
E3E3
E4E4
E5E5
E1E1
E2E2
E3E3
E4E4
E5E5
BATHROOM
NO ELECTRICAL IN CURRENT SCOPE OF WORKE1E1E1E1
LAUNDRY
INSTALL (2) NEW 6" RECESSED CANS
OWNER - REINSTALL WASHER/DRYER HOOKUP
CHECK BREAKER FOR UPSTAIRS OUTLET IN MASTER BATH
E1E1
E2E2
E3E3
E1E1
E2E2
E3E3
DINING (NEW OFFICE)
ADD GRID OF (4) RECESSED LIGHTS
CAP OLD LIGHT FIXTURE
ADD 2 ADDITIONAL OUTLETS IN OFFICE
E1E1
E2E2
E3E3
E1E1
E2E2
E3E3
ENTRY
INSTALL NEW LIGHT FIXTUREE1E1E1E1
OFFICE
NO ELECTRICAL IN CURRENT SCOPE OF WORKE1E1E1E1
ACREY RESIDENCEInterior Remodel13132 Brookshire PkwyCarmel, IN 46033Date:Revision:
9
SHEET OF 16
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited.
PROPOSED M.E.P PLAN NOTES - FIRST FLOOR
SCALE: 1/2" = 1'CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462208/10/2020
DATE:
GENERAL M.E.P NOTES
HVAC Contractor is responsible for engineering
calculation necessary for correct sizing of new
equipment and ductwork being supplied,
fabricated and installed for the project.
HVAC ductwork being installed in unconditioned
areas to be insulated and sealed per current
Building Code Standards.
HVAC contractor to start, test, and balance any
new equipment and ductwork to assure proper
operation of new systems.
Final plumbing materials selected may have an
affect on the final Plumbing Material and
Installation Budgets.
Owners understand that if additional plumbing,
electrical or ductwork is found in walls being
deleted that is not included on the plans there
will be a Change Order during construction to
relocate as necessary.
Owners understand that during mechanical
rough-ins there will be times when the water
service will be shut off to areas in the home.
Plumbing and Lighting fixtures supplied by
Owner will not be warrantied by Custom Living
Plumbing and Lighting fixtures supplied by
Owner must be selected and on-site prior to start
of mechanical rough-ins.
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ] DESIGNER: EMMA MAXWELLE: emma@customlivingusa.comC: 574.292.244108/21/20