HomeMy WebLinkAboutA000.1PLOTTED: July 15, 2020 / Anupam.jain / 2600-IN-MONACO-EC01.DWG
A3-EC01
1FB.1English Tudor2 Car Side EntryFront, Side and Rear Elevations, Roof Plan and Ventilation ScheduleIndiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 46032PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2020
Zach Bittner3/30/2015
GARAGE RIGHT
2600-Monaco
1837.0000
LOT 31
07/15/2020
\A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;7'-11{\H0.750000x;\S1#2;}"
TOP OF PLATEWINDOW HEAD HGT.
TOP OF FLOORTOP OF FOUNDATION
ARCHED SOLDIER COURSE, PER SPEC
18"x72" PANEL SHUTTERS, PER SPEC
ROOF SHINGLES, PER SPEC
8" FASCIA, PER SPEC
10" FRIEZE, PER SPEC
4" CORNER BOARD, PER SPECHORIZONTAL SIDING, PER SPECBRICK SOLDIER COURSE, PER SPEC
8" FASCIA, PER SPEC4" FRIEZE, PER SPEC
BRICK VENEER, PER SPECSTONE SILL, PER SPEC
STONE VENEER, PER SPEC
1214
1214
SHAKE SIDING, PER SPECARCHED STONE SOLDIER COURSE, PER SPEC
SCALE:FRONT ELEVATION1/4" = 1'-0"-
8:12
8:12
8:12
8:12
8:12
\A1;10'-1{\H0.750000x;\S1#8;}"\A1;PLATE HEIGHT\A1;9'-2{\H0.750000x;\S1#2;}"\A1;PLATE HEIGHT\A1;8'-0"
\A1;13'-1{\H0.750000x;\S1#8;}"\A1;PLATE HEIGHT
\A1;3'-6"\A1;MIN.
\A1;R7'-1"
\A1;2'-1"
1214
1214
1214
1214
1214
BRICK SOLDIER COURSE, PER SPEC
4" FRIEZE, PER SPEC
BRICK SOLDIER JACK ARCH, PER SPECBOX BAY w/ 8" TRIM BOARDS, PER SPECHARDIE PANEL (SMOOTH), PER SPEC
\A1;2'-7"
\pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION, TYP.
"A"3352ROOF AREA:SQ. FT.
14:12
\A1;5'-1{\H0.750000x;\S3#4;}"
8:12
8:12
SCALE:ROOF PLAN1/8" = 1'-0"-
\A1;24'-0"
\A1;10'-0"
\pxi-4,l4,ql,t3;POT VENTS
8:128:12
8:12
8:12
8:12
8:12
8:12
8:128:12
14:12
14:12
14:12
14:1214:12
14:1214:12
14:12\A1;8'-0"
128
SCALE:LEFT ELEVATION1/8" = 1'-0"-
4" CORNER BOARD, PER SPEC
8" FASCIA BOARD, PER SPEC
ROOF SHINGLES, PER SPEC8" FASCIA, PER SPEC4" FRIEZE, PER SPEC
BRICK SOLDIER COURSE, PER SPECSTONE VENEER, PER SPEC\A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;7'-11{\H0.750000x;\S1#2;}"
TOP OF PLATEWINDOW HEAD HGT.
TOP OF FLOORTOP OF FOUNDATION
TOP OF FOOTING\A1;3'-6"\A1;MIN.
128
128
128
128
STONE SOLDIER COURSE, PER SPECMASONRY WRAP, PER SPEC
\A1;2'-6"
SCALE:RIGHT ELEVATION1/8" = 1'-0"-
ROOF SHINGLES, PER SPEC
8" FASCIA, PER SPEC10" FRIEZE, PER SPEC
4" CORNER BOARD, PER SPECHORIZONTAL SIDING, PER SPEC
TOP OF PLATEWINDOW HEAD HGT.
TOP OF FLOORTOP OF FOUNDATION
TOP OF FOOTING
\A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;7'-11{\H0.750000x;\S1#2;}"
128
STONE VENEER, PER SPECSTONE SILL, PER SPECBRICK VENEER, PER SPEC4" FRIEZE, PER SPEC
10" FRIEZE, PER SPEC
\A1;3'-6"\A1;MIN.
128
128
128
128
128
128
MASONRY WRAP, PER SPEC
SCALE:REAR ELEVATION1/8" = 1'-0"-
TOP OF PLATEWINDOW HEAD HGT.
TOP OF FLOORTOP OF FOUNDATION
TOP OF FOOTING
\A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;7'-11{\H0.750000x;\S1#2;}"
4" CORNER BOARD, PER SPEC
8" FASCIA, PER SPECROOF SHINGLES, PER SPEC
1214 1214
\A1;11'-1{\H0.750000x;\S1#8;}"\A1;PLATE HEIGHT
4"TRIM, PER SPEC
MASONRY WRAP, PER SPEC
\A1;2'-6"
ELEVATION EC01
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "A"SQ FTG 3352 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 4.47 5.59 5.51 49.16 13 0
AT EAVE 6.70 5.59 5.69 50.84 0 82.00
TOTAL (MIN)11.17 11.17 11.20 100.00
3
HIGH -
RIDGE VENT 4.47 5.59 5.52 49.23 3 0 34.00
AT EAVE 6.70 5.59 5.69 50.77 0 82.00
TOTAL (MIN)11.17 11.17 11.22 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
08/24/20
Adam Schriner