HomeMy WebLinkAboutHSM 031 - SewerProject WO
Project Name
Project Developer
Lift Station
Treatment Plant
Parcel Acreage
EDU in Gallons
PPV II, LLC Address Number
02 Meridian Corridor Station Address 2
Local Sewer Charge - District Contribution
Plan Review and Inspection
Application Fee
EDU Fee
Interceptor Fee
OtherFees
Fees Due
Invoice Number
1&2
31
11211
Heritage View Lane
Carmel
46032
Hamilton
Pulte Group
317-575-2350
PLEASE NOTE: Installation of building sewer shall be per the specifications of the TriCo Regional Sewer Utility (see
� reverse) and any conditions noted below. All installations shall be inspected by TriCo personnel during "open trench"
� phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation drains, or other
sources of ground or stormwater, shall be permitted to enter TriCo's sanitary sewer system. TriCo will assume no
liability for drains which are below the grade level of the nearest downstream manhole nor for laterals which are
� extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) will be
$ responsible for damages to TriCo's sewer system. This includes damages to manholes, castings, manhole lids and
� the like; caused by construction activity on the building site which is the subject of this permit.
� Inspections by TriCo are MANDATORY and shall be arranged by contacting TriCo's o�ce at 844-9200 24 hours in
advance. All new construction will be placed on billing two months after connection has been made or when water is
connected, whichever comes first.
1 The buiiding has: Main ID: HSM20-HSM14
Grease Trap Slab Foundation
� Grease Interceptor Crawl Space Manhole IDs USMH HSM-20 HSM-14 DSMH
� Grit Interceptor Basement YES Lid Elevation 846.23✓ 84623 V
, Grinder Station First Floor Elevation 850.30 � 850.30 V
Water Service Carmel Utilities Basement Elevation 840.50 ,� 840.50 V
Calculation is based on both Manhole Lid Elevations and the elevation o/the First Floor 4,0]' 4.07 Ft.
Y Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump Only
TriCo currently requires that an I&I inspection is pertormed and a Certificate of Compliance is issued prior to occupancy /
- sale of a properrty. Please review attached UI Permit.
Manholes shall remain accessible at all times. Buried manholes will be corrected by the DevelopedOwner.
- The proper class of cleanout must be installed every 100 feet of lateral pipe measured from sewer main to structure.
terms of the conditional permit, if any, are listed below.
Plans have been submitted. �.:...._.�
All fees have been
No Certificate of insurance rPnuirPri
No additional permits required.
No manhole core permit required.
The facilitv is not classified as a Fc�G far.ilitv
(Notes)
By signing below, I attest that I am fan
Builder / Owner Signatu
Printed Nam
Approved By
Ryan
PeRnit is valid f�
2017-1320 Section Number
Heritage at Spring Mill Section 1& 2 Lot Number
MIX Street
0.25 City
310 Zip Code
County
0.00 guilder
0.00
150.00 Phone Number
1984.00 Owner
0.00 phone Number
D.00
2134.00 Occupant
Phone Number
specifications and agree to accept responsibiliiy for all work done under this permit.
� Phone Number c� 17 ��� �� �
- J �J��`
�
t+ftengineer 07/21 /2020
from the date issued. Permit valid only with TriCo seal in red ink.
iuru� rv. �ouege Avenue 5uite A Indianapolis, Indiana 46280 phone 317-844-9200 fax 317-844-9203 www.trico.eco
Residentia/ SANITARY SEWER PERMIT 999913696
Permit Type Final Subdivision Heritage at Spring Mill