HomeMy WebLinkAboutA630 Ceiling DetailsWNT. WALL MOULDING L]/8" X]/8' 1 3/4" MAIN RUNNER OR CRO55 TEE, TVP. 3/8" CLR. AT WALL 1 1/T' TOTAL TRAVEL. "ARMSTRONG'BERD2, 2" END RETAINING CLIP (ASTM A-568) TVP. SCREW THRU MAIN RUNNER ORTEE WEB,TVP. HANGER WIRE "ARMSTRONG"BERD2,2"END RETAIN WG CLIP (ASTM A-568) TVP. TVP.WALLANGLE CONNECTION �4O�b'O oC9TRT rFF �N,y fq NOTES: 1. BASELWESUSPENDEDCEILINGSVSTEMISBASEDON"ARMSTRONG"- SEISMIC R% COMPONENTS FOR PERMIT AND BID PURPOSES. ALTERNATIVE MENUFACTURERS ARE PERMITTED PROVIOING PRODUCT IS COMPARABLE INCWDING BUT NOT LIMITED TO FUNCTION, DIMENSION, PERFORMANCE, APPEARANCE AND OTHER CHARACTERISTICS THAT EQUAL OR EXCEED SPECIFlED PRODUCT. CONTRACTOR IS RESPONSIBLE FOR CETPoFlCATION OF ALTERNATNEPRODUCTS. 2. EXPOSED POP RIVETS NOT PERMITTED. 3. SVSTEMCOMPONENTSSHALLBECOMPLIANTWITHCODEDEFlNED SEISMIC CATEGORIES ENFORCED BV LOCAL JURIS�ICTION. 4. MA%. CEILING AREA PERMITTED WITHOUT SEISMIC JO WT IS 2500 SF. SEISMIC JOING ASSEMBLV SHALL BE CONCEALED FROM BELOW. 5. IN JURISDICTIONS ENFORCING THE IBC (OR CBC BASED ON IBC) SYSTEMS CLASSIFlED AS INTERMEDIATE DUTV ARE LIMITED TO USE IN SEISMIC DESIGN CATEGORIES A, B, & Q SVSTEMS CLASSIFIED AS HEAVV DUTV SHALL BE USED IN SEISMIC DESIGN CATEGORIES D, E, & F. 6. HANGER WIRE: N0. 12 SWG (O.l O51NCH, 2J MM DIAJ GALV. STEEL 48" 0 C. MAX. AND AT ALL FOUR CORNER OF LIGHTWG RXTURES. CONNECTIONS MUST BE SEW RE� WITH (3) FULL TURNS MIN. 3" HIGH MA%. 7. HANGER CLIPS: 0.0451NCH TH. (1.14MM) 2" WIDE X 31/2" LONG (S1MM X 90MMJ GALV. STEEL 8. PARTITIONSATTACHEDTOCEILINGSUSPENSIONSVSTEMSHALLBE LATERALLY BRACED TO BLDG. STRUCTURE INDEPENDENT FROM CEILING. HANGER WIRE LOCATION �la 4'-0" 0 G TYP. MAIN RUNNER CROSS TEE SEISMIC JOINT CLIP, TVP.SEEENLARGED �ETAIL SEISMIC JOINT CLIP MAIN RUNNER TEE TVP. CEILING GRID CONT. BEAD OF 3/8" NON-HARDENING SEALANT 5/8" PAIMED TVPE'X' GWB, PAINTED SCHEDULE� CEILING FINISH �TYP. CEILING WIRE BRACING (NON-SEISMIC) � SCREWTHRUTEE �CEILING DETAIL -ACP TO WALL V smie i l8•' = 1•-0•' J s<eia 12•• = 1•-0•• NOTE: GC TO USE THIS DETAIL ONLY WHEN HANGING UNISTRUT FROM LAB IS NOT POSSIBLE DUE TO EXISTING CONDITIONS OR HVAC COMPONENTS. SEE FINISH SCHEDULE AND REFLECTED CEILING PLAN FOR FINISHES. WHERE SLAB AND DUCT IS PAINTED ABOVE. UNISTRUT TO BE PAINTED EXISTING STRUCTURE ABOVE DUCT OR CEILING MOUNTED DEVICE. GC TO VERIFY CONDITIONS IN FIELD PRIOR TO INSTALLATION OF UNISTRUTAND LIGHT FIXTURE. PARTITIONS AS SCHEDULED UNISTRUT SECURED TO WALL PARTITIONS ON EITHER SIDE OF CORRIDOR. GC TO PRIVIDE ADDITIONAL SUPPORT, AS REQUIRED. MOUNTING AND ASSEMBLY TO MEET LOCAL JURISDICTION'S CODES AND REQUIREMENTS. REFER TO RCP UNISTRUT DETAIL - FOR CORRIDORS AND OFFICES WHERE APPLICABLE s��A iz., �.-0.. RELEA5E0 FOR CONSTRUCTION OVE W/ PLANTS AT RAISED Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel r �un��V l�rcNal�l,��' � DATE: OH�Z5 2O WALL WASH LIGHT FlXTURE AS SCHEDULED. ALL W IRING TO BE CONCEALED. CENTER FIXTURE WI EDGE OF SOFFIT FlNISHED LIGHT COVE IMERIOR PAIMED P-' BEAD TAPED AND SPACKLED TIGHT FINISHED TO MATCH 11N0ERSI�E OF SOFFII WALL FlNISH AS SCHEDULED FINISH TO CONTINUE TO T.O. COVE CEILING DETAIL - SOFFIT AT CAFE ���� ie.., �.-0.. � 5/8" PAINTED TVPE'X' GW B, PAINTED SCHEDULED CEILING FlNISH L-0SA LIGHT FlXTURE SEE RERECTED CEILWG PLAN ANDLIGHTFIXTURESCHEDULE FORPOWER AND LOCATION REQUIREMENTS. ALL WIRING TO BE CONCEALED m.m�ar_�e, � IOUS METAL CORNER BEAD, �ANDSMOOTH ,..,LED CEILING. SEE REFLECTED CEILING PLAN AND FlNISH SCHEDULE CEILING DETIAL - SOFFIT AT BANQUETTE NOOK W/ PLANTS scaie�. 6• - 1•_��• 5/8" PAINTED TVPE'X' GWB, PAINTED SCHEDULED FlNISH EARAWAV BEAD � JTINUOUS METAL CORNER BEAD, 'E & SAND SMOOTH __.1EDULE� CEILMG. SEE RERECTED CEILING PLAN AND FINISH SCHEDULE SHADE COVE DETAIL scde�. 3•' = 1• 0" 2 V7' STUD, KEEP AS TIGHT TO KICKER/PERIMETER WALL AS POSSIBLE KICKER 5/8" GVPSUM TO BOTTOM OF DECK BLOCKING AS REQUIRED ALIGN BOTTOM OF GVP WITH BOTTOM OF SHADES WT-2 SHA�ES LIGHT FIXTURE MOUNTED TO UNISTRUT. CONFIRM LIGHT FIXTURE TYPE W ITH LIGHT FIXTURE SCHEDULE. EARAWAVBEAD (12GA) METAL STUDS 16" OA-W ITH DIAGONAL BRACE @ 4'-0" O.Q,STAGGERED. 12GA) METAL STUD516" OA.W ITH DIAGONAL BRACE Q 4'-0" O.C.,STAGGERED. V) #10 TEK CREWS, TVP CHEDULED FlNISHED CEILING. SEE RERECTED CEILING PLAN ECESSED LIGHT FI%TURE AS SCHEDULED. REFER TO RCP 5/8" HAT CHANNEL (2) LAVERS OF 5/6" TVPE'X' GWB � SEE RCP J� � �SCHEDULE�CEILING.SEERERECTE�CEILINd PLAN AND FINISH SCHEDULE CONTINUOUS METAL CORNER BEAD, TAPE & SAND SMOOTH L-5 LIGHT FlXTURE SEE RERECTED CEILING PLAN AND LIGHT FIXTURE SCHEDULE FOR POWER AND LOCATION REQUIREMENTS. ALL WIRING TO BE CONCEALED �— CONTINUOUS SCHEDULED WALL FINISH CEILING DETAIL - TYP. COVE LIGHT FIXTURE smiA 3" = 1'-0" >AINTED LBRACKET TO MATCH TECTUM �/8" X 20 GA FURRING @ i 6" JC OR DRYWALL GRIO VUMBER OF SCREWS PER PANEL PER MANUFACTURER'S 4ECOMMENDATION. HEAO TO BE FWSH W ITH PANEL, )O NOT COUNTERSINK. >CP-1 BEVELED EDGE ACOUSTIC PANEL V2'REVEALPANELEDGE FlNISHED AS SCHEDULED iCHEDULED PARTITION, SEE PARTITION PLAN WALLCOVERING. WHERE OCCURS. CONTINUE FINISH 6" ABOVE CEILWG, TVP UNDERSIDE OF STRl1CTURE 20GA CONTINUOUS CORNER BEAD TO BE TAPED AND SPACKLED TIGHT CONTINUOUS BEAD OF 3/8" NON-HARDENING ACOUSTICAL SEALANT 3fi2S 12533 METAL STUD516" O.C. W ITH �IAGONAL BRACK �a14'-0' O.C. STAGGERED. ATTACH TO UNDERSIDE OFSTRUCTUREABOVE METAL STUD FURRING CHANNELS W/ APPROVED HANGER CLIPS CONTINUOUS METAL CORNER BEAD, TAPE & SAN� SMOOTH SEE RC� CEILING DETAIL - SOFFIT EDGE s�ae 3"=�'-0" 1-1 INDUSTRIOUS COWORKING 880 W MONON GREEN BLVD CARMEL, IN 46032 OWNEPRENANT INDUSTRIOUS 215PARKAVES,4E1300 NEW YORK, NY 1 W03 ARCXITECT OF HECOPD NORX 325 N LASALLE Si- SOIiE SCO CHICAGO. IL 60654 PEiER.DUBWCmNORR-COM 312-0242400 MEP ENGINEER MEENGINEERS 29 WEST 38iH SiREEi, SiH FLOOR NEW YORK. NY 10018 CONiACi: BRIAN SHASSIAN BBIANSHASSIANC�.ME-ENGINEER$_COM JOHN HIGGINS JOHN.HIGGWS(�MEENGINEERS.COM �212J 44]-6]]0 PHONE LIGHTING DESIGNER REGENCY 9261 JOkDAN AVE CHAiSWORiH, CA 800-28d-202J ISSUE DATES REV. DAiE DESCRIPiION 06/OS/2020 DD3 06/18l2020 CDvI 0]/06/2020 CDv2 O]/V/2020 100%/PERMIT SEAL&SIGNATUNE BY CHECK BG PJ BC PJ eC Po BC PJ CARMEL CITY- 880 MONON GREEN PRQIECT NUMBER IND680MON DRAWING TITLE CEILING DETAILS SCALE As indicated SHEET NUMBER A-630 oF PROJECTNAME