HomeMy WebLinkAboutA905 SpecsSECTION 087100 - DOOR HARDWARE
PART1-GENERAL
1.1RELATEDDOCUMENTS
A.DRAWINGSANDGENERALPROVISIONSOFTHECONTRACT INCLUDINGGENERALAND
SUPPLEMENTARV CONDITIONS AND OIVISION 01 SPEQFICATION SECTIONS APPLV TO THIS
SECTION.
12SUMMARV
A. SECTION INCLUDES:
1. MECHANICAL DOOR HARDWARE FOR THE FOLLOW ING:
A. SW ING W G DOORS.
B. SLI�ING DOORS.
C. FOL�ING DOORS.
2. CVLINDERS FOR DOOR HARDWARE SPEQFlED IN OTHER SECTIONS.
3. ELECTRIFIED DOOR HARDWARE.
1.3 ACTION SUBMITTALS
A. PRODUCT DATA: FOR EACH TVPE OF PRODUCT INDICATED. INCW DE CONSTRUCTION AND
INSTALLATION DETAILS, MATERIAL DESCRIPTIONS, DIMENSIONS OF INDIVIDUAL COMPONENTS AN�
PROFILES, AND FINISHES.
B. DOOR HARDWARE SCHEDULE PREPARED BV OR UNDER THE SUPERVISION OF INSTALLER,
DETAILING FABRICATION AND ASSEMBLV OF DOOR HARDWARE, AS WELL AS INSTALLATION
PROCEDURES ANo DIAGRAMS. COOROINATE FINAL DOOR HARDWARE SCHEDULE W ITH DOORS,
FRAMES, AND RELATED W ORK TO ENSURE PROPER SIZE, THICKNE55, HAND, FUNCTION, AND
FINISH OF DOOR HARDWARE. KEVING SCHEDULE: PREPARED BY OR UNDER THE SUPERVISION OF
INSTALLER, DETAILING OW NERS FlNAL KEVING INSTRUCTIONS FOR LOCKS. INCLUDE SCHEMATIC
KEYING DIAGRAM AND INDEX EACH KEV SET TO UNIOUE DOOR DESIGNATIONS THAT ARE
COOROINATED WITH THE CONTRACT DOCUMENTS.
1.4 QUALITV ASSURANCE
A. INSTALLER QUALIRCATIONS'. SUPPLIER OF PRODUCTS AND AN EMPLOVER OF WORKERS TRAMED
AND APPROVED BV PRODUCT MANUFACTIIRERS AND AN ARCHITECTl1RAL HARDWARE
CONSULTANT W HO IS AVAILABLE DURING THE COURSE OF THE W ORK TO CONSULT W ITH
CONTRACTOR, ARCHITECT, AND OWNER ABOUT DOOR HARDWARE AND KEVING.
B. SOURCE LIMITATIONS: OBTAIN EACH TVPE OF DOOR HARDWARE FROM A SINGLE MANUFACTURER.
Q RRE-RATED DOOR ASSEMBLIES: WHERE FlRE-RATED DOOR ASSEMBLIES ARE INDICATED, PROVIDE
DOOR HARDW ARE RATED FOR USE IN ASSEMBLIES COMPLVING W ITH NFPA 80 THAT ARE LISTED
AND LABELED BV A QUALIFIED TESTWG AGENCV, FOR FIRE-PROTECTION RATINGS INDICATED,
BASED ON TESTING AT POSITIVE PRESSURE ACCORDING TO NFPA 252 OR UL 10C, UNLESS
OTHERW ISE INDICATED.
D. SMOKE AND DRAFT-CONTROL DOOR ASSEMBLIES: W HERE SMOKE- AND DRAFLCONTROL DOOR
ASSEMeLIES ARE REQUIRED, PROVIDE DOOR HARDWARE THAT MEET REQUIREMENTS OF
ASSEMBLIES TESTED ACCORDING TO UL 1]84 AND INSTALLED IN COMPLIANCE WITH NFPA 105.
E. ELECTRIFIED DOOR HARDWARE: LISTE� AND LABELED AS DERNED IN NFPA ]Q ARTICLE 100, BV A
TESTING AGENCV ACCEPTABLE TO AUTHORITIES HAVING JURIS�ICTION.
F. MEANS OF EGRESS DOORS: LATCHES DO NOT REQUIRE MORE THAN 15 LBF (6] N) TO RELEASE THE
LATCH. LOCKS DO NOT REQUIRE USE OF A KEV, TOOL, OR SPECIAL KNOW LEDGE FOR OPERATION.
G. ACCESSIBILITV RE�UIREMENTS: COMPLY W ITH APPLICABLE PROVISIONS IN THE DOJ'S ADA
STANDARDS FOR ACCESSIBLE DESIGN FOR DOOR HARDWARE ON DOORS IN AN ACCESSIBLE
ROUTE.
1.5DELNERY,STORAGE,ANDHANDLWG
A. INVENTORV DOOR HARDWARE ON RECEIPT AND PROVIDE SECURE LOCK-UP FOR DOOR HARDWARE
DELIVERED TO PROJECT SITE. TAG EACH ITEM OR PACKAGE SEPAR4TELV WITH IDENTIFICATION
COORDINATED WITH THE FlNAL DOOR HARDWARE SCHEDULE, AND INCLUDE INSTALLATION
INSTRUCTIONS, TEMPLATES, AND NECESSARV FASTENERS W ITH EACH ITEM OR PACKAGE.
DELNER KEVS ANO PERMANENT CORES TO OW NER BV REGISTERED MAIL OR OVERNIGHT
PACKAGE SERVICE.
1.6 COORDINATION
A. COORDINATE LAVOUT AND INSTALLATION OF FLOOR-RECESSED DOOR HARDWARE W ITH FLOOR
CONSTRUCTION. CAST ANCHORING INSERTS INTO CONCRETE.
B. INSTALLATION TEMPLATES'. DISTRIBUTE FOR DOORS, FRAMES, AND OTHER WORK SPECIFlED TO BE
FACTORV PREPARED. CHECK SHOP DRAW W GS OF OTHER WORK TO CONFIRM THAT ADEQUATE
PROVISIONS ARE MADE FOR LOCATING AND INSTALLING DOOR HARDWARE TO COMPLV WITH
IN�ICATE� REQUIREMENTS.
G SECURITV: COORDINATE INSTALLATION OF DOOR HARDWARE, KEVING, AND ACCESS CONTROL W ITH
OW NER'S SEW RITV CONSULTANT.
D. ELECTRICAL SVSTEM ROUGHING-IN: COORDINATE LAVOUT AND INSTALLATION OF ELECTRIFlE�
DOOR HARDW ARE W ITH CONNECTIONS TO POW ER SUPPLIES AND BUILDING SAFETV AND
SECURITv SYSTEMS.
E EXISTING OPENINGS: WHERE HAR�WARE COMPONENTS ARE SCHEDULED FOR APPLICATION TO
E%ISTING CONSTRUCTION OR WHERE MODIFICATIONS TO EXISTING DOOR HARDWAREARE
REQUIREo, FIELD VERIFV EMISTING CONDITIONS AND COORDINATE INSTALLATION OF DOOR
HARDWARE TO SUIT OPENING CONDITIONS AND TO PROVIOE PROPER DOOR OPERATION.
1.]WARRANTV
A. SPECIAL WARRANTY: MANUFACTURER'S STANDARD FORM IN WHICH MANUFACTURER AGREES TO
REPAIR OR REPLACE COMPONENTS OF DOOR HARDWARE THAT FAIL IN MATERIALS OR
WORKMANSHIP WITHW SPECIFIE� WARRANTV PERIOD.
1.8 MAIMENANCE SERVICE
A. MAMTENANCE TOOLS AND INSTRUCTIONS: FURNISH A COMPLETE SET OF SPECIALIZED TOOLS AND
MAINTENANCE INSTRUCTIONS FOR OW NER'S CONTINUED ADJUSTMENT, MAINTENANCE, AND
REMOVALANDREPLACEMENTOFDOORHARDWARE.
PART2-PRODUCTS
21 SCHEDl1LED �OOR HARDWARE
A. PROVI�E �OOR HARDWARE FOR EACH DOOR AS SCHEDULED ON DRAWINGS TO COMPLV WITH
RE�UIREMENTS IN THIS SECTION.
22 MECHANICAL LOCKS AND LATCHES
A. LOCK FUNCTIONS�. AS INDICATED IN DOOR HARDWARE SCHEDULE.
2.3 ELECTRIC STRIKES
A. ELECTRIC STRIKES: BHMA A156.31; GRADE 1; WITH FACEPLATE TO SUIT LOCK AND FRAME.
2.4 ELECTROMAGNETIC LOCKS
A. ELECTROMAGNETIC LOCKS: BHMAA15623; ELECTRICALLV POWERED; WITH ELECTROMAGNET
ATTACHED TO FRAME AND ARMATURE PLATE ATTACHED TO DOOR; FULL-EXTERIOR OR FULL-
INTERIOR TVPE, AS REQUIRED BVAPPLICATION INDICATED.
2.5 EXIT LOCKS AND EXIT ALARMS
A. EXIT LOCKS AND ALARMS: BHMA A15629, GRADE 1.
2.6MANUALFLUSHBOLTS
A. MANUAL FLUSH BOLTS: BHMAA156.16; MINIMUM 3/4-WCH (19-MM)THROW', DESIGNED FOR
MORTISING INTO DOOR EDGE.
2] AUTOMATIC AND SELFLATCHING FLUSH BOLTS
A. AUTOMATIC AND SELF-LATCHING FWSH BOLTS: BHMA A156.16; MINIMUM 3/4-WCH (19-MM) THROW;
DESIGNED FOR MORTISING INTO DOOR EDGE.
2.8 EXIT DEVICES AND AUXILIARV ITEMS
A EXIT DEVICES AND AUXILIARV ITEMS'. BHMA A156.3.
2 9 LOCK CVLIN�ERS
A. LOCK CYLINDERS: TUMBLER TVPE, CONSTRUCTED FROM BRASS OR BRONZE, STAINLESS STEEL, OR
NICKEL SILVER.
2.10 ACCESSORIES FOR PAIRS OF DOORS
A COORDINATORS�. BHMA A156.3; CONSISTING OF ACTNELEAF, HOLD-OPEN LEVER AND INACTNE
LEAF RELEASE TRIGGER; FABRICATED FROM STEEL W ITH NYLON-COATED STRIKE PLATES; W ITH
BUILT-IN, ADJUSTABLE SAFETV RELEASE; AND W ITH INTERNAL OVERRIDE.
2.11 SURFACE CLOSERS
A. SURFACE CLOSERS: BHMA A156.4', RACK-AND-PINION HYDRAULIC TVPE W ITH ADJUSTABLE SW EEP
AND LATCH SPEEDS CONTROLLED BV KEV-OPERATED VALVES AND FORGED-STEEL MAIN ARM.
COMPLV W ITH MANUFACTURER'S WRITTEN RECOMMENDATIONS FOR SIZE OF DOOR CLOSERS
DEPENDING ON SIZE OF DOOR, EXPOSURE TO W EATHER, AND ANTIQPATE� FREOUENCV OF USE.
PROVIDE FACTORV-SIZED CLOSERS, ADJUSTABLE TO MEET FIEL� CONDITIONS AND
REQUIREMENTS FOR OPENWG FORCE.
2.12CONCEALEDCLOSERS
A. CONCEALE� CLOSERS: BHMA A156.4; RACK-AND-PINION HVDRAULIC TVPE W ITH ADJUSTABLE SW EEP
AND L4TCH SPEEDS CONTROLLED BY KEV-OPERATED VALVES. COMPLY W ITH MANUFACTURER'S
WRITTEN RECOMMENDATIONS FOR SIZE OF DOOR CLOSERS DEPENDING ON SRE OF DOOR,
EXPOSURE TO WEATHER, AND ANTICIPATED FREpl1ENCV OF USE. PROVIDE FACTORKSIZED
CLOSERS, ADJUSTABLE TO MEET FlELD W NDITIONS AND REQUIREMENTS FOR OPENING FORCE.
213 CLOSER HOLDER RELEASE DEVICES
A. CLOSER HOL�ER RELEASE DEVICES: BHMA A156.15; GRADE 1; CLOSER CONNECTED W ITH SEPARATE
OR INTEGRAL RELEASWG AND FlRE- OR SMOKE DETECTING DEVICES. DOOR SHALL BECOME SELF
CLOSING ON INTERRUPTION OF SIGNAL TO RELEASE �EVICE. AUTOMATIC RELEASE IS ACTIVATED
BV SMOKE DETECTION SVSTEM, LOSS OF POWER.
2.74 OVERHEA� STOPS AND HOLDERS
A. OVERHEAD STOPS AND HOLDERS: BHMAA156.8.
215 DOOR GASKETING
A. DOOR GASKETING. BHMA A15622; AIR LEAKAGE NOT TO EXCEED 450 CFM PER FOOT (0.000]14 CU.
M/S PER M) OF CRACK LENGTH FOR GASKETING OTHER THAN FOR SMOKE CONTROL, AS TESTED
ACCORDING TO ASTM E 283; WITH RESILIENT OR FLEkIBLE SEAL STRIPS THAT ARE EASILV
REPLACEABLE AND READILVAVAILABLE FROM STOCKS MAINTAMED BY MANUFACTURER.
2.i6THRESHOLDS
A. THRESHOLDS: BHMA A15621; FABRICATED TO FULL WIDTH OF OPENING INDICATED.
2.1] SLIDWG DOOR HARDWARE
A. SLIDING DOOR HARDWARE: BHMA A156.14', CONSISTING OF COMPLETE SETS WCLUDING RAILS,
HANGERS, SUPPORTS, BUMPERS FLOOR GUIDES, AND ACCESSORIES INDICATE�.
2.18 FABRICATION
A. FASTENERS: PROVIDE DOOR HARDWARE MANUFACTURED TO COMPLV W ITH PUBLISHED
TEMPLATES PREPARED FOR MACHME, WOOD, AND SHEET METAL SCREWS. PROVIDE SCREWS
THAT COMPLV W ITH COMMERCIALLV RE W GNRED INDUSTRY STANDARDS FOR APPLICATION
INTENDED, EXCEPT ALUMINUM FASTENERS ARE NOT PERMITTED. PROVIDE PHILLIPS FLAT-HEAD
SCREWS W ITH FINISHED HEADS TO MATCH SURFACE OF DOOR HARDWARE, UNLESS OTHERWISE
INDICATEO.
219 FINISHES
A. PROVIDE FlNISHES COMPLVING WITH BHMAA156.18 AS INDICATED IN DOOR HARDWARE SCHEDULE.
PROTECT MECHANICAL FlNISHES ON EXPOSED SURFACES FROM DAMAGE BV APPLVWG A
STRIPPABLE, TEMPORARV PROTECTNE COVERING BEFORE SHIPPING. APPEARANCE OF FlNISHED
WORK: VARIATIONS IN APPEARANCE OF ABUTTING OR A�JACENT PIECES ARE ACCEPTABLE IF
THEV ARE WITHIN ONE-HALF OF THE RANGE OFAPPROVED SAMPLES. NOTICEABLE VARIATIONS IN
THE SAME PIECE ARE NOT ACCEPTABLE VARIATIONS IN APPEARANCE OF OTHER COMPONENTS
ARE ACCEPTABLE IF THEV ARE WITHIN THE RANGE OF APPROVED SAMPLES AN� ARE ASSEMBLED
OR INSTALLED TO MINIMRE CONTRAST.
PART 3 - EXECUTION
3.1 EXAMINATION
A. EXAMWE DOORS ANo FRAMES, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH REQUIREMENTS
FOR MSTALLATION TOLERANCES, LABELED RRE-RATE� DOORASSEMBLV CONSTRUCTION, WALL
ANO FLOOR CONSTRUCTION, AND OTHER CON�ITIONS AFFECTING PERFORMANCE.
B. EXAM W E ROUGHING-W FOR ELECTRICAL POW ER SVSTEMS TO VERIFY ACTUAL LOCATIONS OF
W IRING CONNECTIONS BEFORE ELECTRIFIE� DOOR HARDWARE INSTALLATION.
G PROCEED WITH INSTALLATION ONLV AFTER UNSATISFACTORV CONDITIONS HAVE BEEN
CORRECTED.
32 PREPARATION
A. STEEL DOORS AND FRAMES: FOR SURFACE APPLIED DOOR HARDWARE, DRILL AND TAP DOORS AND
FRAMES ACCORDWG TO ANSIISDI A250.6.
B. WOOD DOORS'. COMPLV WITH DHI W DHS 5"RECOMMEN�ED HARDWARE REINFORCEMENT
LOCATIONS FOR MINERAL CORE WOOD FLUSH DOORS"
RELEA5E0 FOR CONSTRUCTION
Suhjec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel ` �
�un��V l�rcNal�=L.
�
DATE: OH�Z5 2O
SECTION 087100 - DOOR HARDWARE (CONT.)
3.3 INSTALLATION
A. MOUNTING HEIGHTS: MOUNT DOOR HARDWARE UNITS AT HEIGHTS INDICATED ON DRAW INGS
UNLESS OTHERW ISE INDICATED OR REQUIRED TO COMPLV W ITH GOVERNING REGULATIONS.
1. STAN�ARo STEEL o00RS ANo FRAMES: ANSIIS�I A250.8.
2. CUSTOM STEEL �OORS AND FRAMES'. HMMA 831.
3. WOOD DOORS: DHI WDHS 3, "RECOMMENDED LOCATIONS FOR ARCHITECTl1RAL HARDWARE FOR
WOOD RUSH DOORS."
B. INSTALL EACH �OOR HARDWARE ITEM TO COMPLV WITH MANUFACTURER'S WRITTEN
INSTRUCTIONS. W HERE CUTTING AND FITTING ARE REQUIREO TO WSTALL DOOR HARDWARE ONTO
OR INTO SURFACES THAT ARE LATER TO BE PAIMED OR FlNISHED IN ANOTHER WAV, COORDINATE
REMOVAL, STORAGE, AND REINSTALLATION OF SURFACE PROTECTNE TRIM UNITS WITH RNISHING.
DO NOT INSTALL SURFACE-MOUNTED ITEMS UNTIL FINISHES HAVE BEEN COMPLETED ON
SUBSTRATESINVOLVED.
Q HMGES'. INSTALL TVPES AND IN QUANTITIES INDICATED IN DOOR HARDWARE SCHEDULE BUT NOT
FEW ER THAN THE NUMBER RECOMMEN�ED BV MANUFACTURER FOR APPLICATION INDICATE� OR
ONE HWGE FOR EVERV 301NCHES (]50 MM) OF DOOR HEIGHT, WHICHEVER IS MORE STRMGENT.
UNLESS OTHER EQUIVALENT MEANS OF SUPPORT FOR DOOR, SUCH AS SPRING HINGES OR
PIVOTS, ARE PROVI�ED.
D. INTERMEDIATE OFFSET PIVOTS: WHERE OFFSET PIVOTS ARE INDICATED, PROVIDE INTERMEDIATE
OFFSET PIVOTS IN pUANTITIES INDICATED IN DOOR HAR�WARE SCHEDULE BUT NOT FEWER THAN
ONE INTERMEDIATE OFFSET PIVOT PER �OOR AND ONE ADDITIONAL INTERMEDIATE OFFSET PIVOT
FOR EVERV 301NCHES (]50 MM) OF DOOR HEIGHT GREATER THAN 901NCHES (2286 MM).
E LOCK CVLINDERS: INSTALL CONSTRUCTION CORES TO SECURE BUILDING AN� AREAS DURING
CONSTRUCTION PERIOD.
F. THRESHOLDS: SET THRESHOLDS FOR EXTERIOR DOORS AND OTHER DOORS INDICATED IN FULL BE�
OFSEALANT.
G. STOPS: PROVIDE FLOOR STOPS FOR DOORS UNLESS WALL OR OTHER TVPE STOPS ARE INDICATED
IN DOOR HARDWARE SCHEDULE. DO NOT MOUNT FLOOR STOPS WHERE THEV W ILL IMPEDE
TRAFFIC.
H. PERIMETER GASKETING: APPLV TO HEAD ANO JAMB, FORMING SEAL BETWEEN DOOR AN� FRAME.
I. MEETWG STILE GASKETING: FASTEN TO MEETING STILES, FORMWG SEAL WHEN DOORS ARE
CLOSE�. DOOR BOTTOMS: APPLV TO BOTTOM OF DOOR, FORMING SEAL WITH THRESHOLD WHEN
DOOR IS CLOSED.
3.4 ADJUSTING
A. INITIAL ADJUSTMENT' ADJl15T AND CHECK EACH OPER4TING ITEM OF OOOR HARO WARE AND EACH
DOOR TO ENSURE PROPER OPERATION OR FUNCTION OF EVERV UNIT. REPLACE UNITS THAT
CANNOT BE ADJUSTED TO OPERATE AS INTENDED. ADJUST DOOR CONTROL DEVICES TO
COMPENSATE FOR RNAL OPERATION OF HEATING AND VENTILATING EQUIPMENT AND TO COMPLV
W ITH REFERENCED ACCESSIBILITV REpUIREMENTS.
B. OCCUPANCV ADJUSTMENT�. APPROXIMATELV SIX MONTHS AFTER DATE OF SUBSTANTIAL
COMPLETION, INSTALLER'S ARCHITECTURAL HARDWARE CONSULTANT SHALL EXAM W E AND
READ JUST EACH ITEM OF �OOR HAR�WARE, INCLUDING ADJUSTING OPERATING FORCES, AS
NECESSARV TO ENSURE FUNCTION OF DOORS, DOOR HARDWARE, AND ELECTRIFlED DOOR
HARDWARE.
3.5 CLEANING AND PROTECTION
A. CLEAN ADJACENT SURFACES SOILED BV DOOR HARDWARE INSTALLATION. CLEAN OPERATWG
ITEMS AS NECESSARV TO RESTORE PROPER FUNCTION AND RNISH. PROVIDE FlNAL PROTECTION
AN� MAINTAW CONDITIONS THAT ENSURE THAT �OOR HARDWARE IS W ITHOUT DAMAGE OR
DETERIORATION AT TIME OF SUBSTANTIAL COMPLETION.
SECTION 088000 - GLAZING
PART1-GENERAL
1.iRELATEDDOCUMENTS
A. DRAW INGS AN� GENERAL PROVISIONS OF THE CONTRACT, INC W DING GENERAL AND
SUPPLEMENTARV CONDITIONS AND DIVISION 01 SPECIFICATION SECTIONS, APPLV TO THIS
SECTION.
1.2SUMMARV
A. SECTION INCLUDES:
1. GLASS FOR IMERIOR W INDOWS, IMERIOR DOORS, INTERIOR BORROWED LITES, INTERIOR
STOREFRONT FRAMING
2. GLAZING SEALANTS AND ACCESSORIES.
1.3 COORDINATION
A. COOROINATE GLAZING CHANNEL DIMENSIONS TO PROVIDE NECESSARV BITE ON GLA55, MINIMUM
EDGE AND FACE CLEARANCES, AND ADE�UATE SEALANT THICKNESSES, WITH REASONABLE
TOLERANCES.
1 4 ACTION SUBMITTALS
A. PRODUCT DATA: FOR EACH TVPE OF PRODUCT.
B. GL4SS SAMPLES FOR EACH TYPE OF GLASS PRODUCT OTHER THAN 0.EAR MONOLITHIC VISION
GLA55, THE FOLLOW ING PRODUCTS; 121NCHE5 (300 MM) SQUARE.
1. COATED GLASS.
2. LAMINATE� GLASS.
C. GLAZING SCHE�l1LB LIST GLASS TVPES AND THICKNESSES FOR EACH 9ZE OPENING AND
LOCATION. USE SAME DESIGNATIONS INDICATE� ON DRAWINGS.
1.5 DELIVERV. STORAGE AND HANDLING
A. PROTECT GLAZING MATERIALS ACCORDING TO MANUFACTURER'S W RITTEN INSTRl1CTIONS.
PREVENT DAMAGE TO GLASS AND GLAZING MATERIALS FROM CONDENSATION, TEMPERATURE
CHANGES, DIRECT EXPOSURE TO SUN, OR OTHER CAUSES.
B. COMPLV WITH WSULATING-GLASS MANUFACTURER'S WRITTEN WSTRUCTIONS FOR VENTING AND
SEALWG UNITS TO AVOID HERMETIC SEAL RUPTURES DUE TO ALTITUDE CHANGE.
1.6 FlELD CONDITIONS
A. ENVIRONMENTAL LIMITATIONS'. DO NOT PROCEED WITH GLAZING WHEN AMBIENTAN� SUBSTRATE
TEMPERATURE CONDITIONS ARE OUTSIDE LIMITS PERMITTED BV GLAZING MATERIAL
MANUFACTURERS AND W HEN GLAZWG CHANNEL SUBSTRATES ARE W ET FROM RAIN, FROST,
CON�ENSATION, OR OTHER CAUSES.
17 WARRANTY
A. MANUFACTURER'S SPECIAL WARRANTV FOR COATED-GLASS PRODUCTS: MANUFACTURER AGREES
TO REPLACE COATE�-GLA55 UNITS THAT DETERIORATE WITHM SPEQFIED WARRANTV PERIOD.
DETERIORATION OF COATE� GLASS IS DEFINED AS DEFECTS DEVELOPED FROM NORMAL USE
THAT ARE NOT ATTRIBUTED TO GLASS BREAKAGE OR TO MAINTAINING AND CLEANING COATED
GLA55 CONTRARV TO MANUFACTURER'S WRITTEN WSTRUCTIONS. DEFECTS INCLUDE PEELING,
CRACKING, AND OTHER INDICATIONS OF DETERIORATION IN COATMG.
1. WARR4NTY PERIW �. 10 YEARS FROM DATE OF SUBSTANTIAL COMPLETION.
B.MANUFACTURER'SSPEQALWARRANTVFORLAMINATEDGLASS:MANUFACTURERAGREESTO
REPLACE LAMINATED-GLA55 UNITS THAT �ETERIORATE WITHIN SPECIFIED WARRANTV PERIOD.
DETERIORATION OF LAMINATED GLASS IS DEFMED AS DEFECTS DEVELOPED FROM NORMAL USE
THAT ARE NOT ATTRIBUTED TO GLASS BREAKAGE OR TO MAINTAINING AN� CLEANING LAMINATEO
GLASS CONTRARV TO MANUFACTURER'S WRITTEN INSTRUCTIONS. DEFECTS INCLUDE
EDGE SEPARATION, DELAMINATION MATERIALLV OBSTRUCTING VISION THROUGH GLASS, AND
BLEMISHES EXCEEDING THOSE ALLOW ED BY REFERENCED LAMINATED-GLASS STANOARO.
1. WARRANTV PERIOD�. 10 VEARS FROM DATE OF SUBSTANTIAL COMPLETION.
G SAFETV GLAZING LABELING: WHERE SAFETV GLAZWG IS INDICATED. PERMANENTLV MARK GLAZING
WITH CERTIFlCATION LABELOF MANUFACTURER LABEL SHALL INDICATE MANUFACTURER'S NAME,
TVPE OF GLASS, THICKNESS, AN� SAFETV GLAZING STANDARD W ITH W HICH GLASS COMPLIES.
D. THICKNESS: GLASSTHICKNESS SHALL BE DETERMMED BV THE MANUFACTURER.
1.8 GLASS PRODUCTS
A. CLEAR ANNEALED FLOAT GLA55: ASTM C 1036, TVPE I, CLASS 1(0.EAR), QUALITY-43.
B. FULLV TEMPERED FLOAT GLASS: ASTM C 1048, KIND FT (FULLY TEMPERED), CONDITION A
(UNCOATED) UNLESS OTHERWISE INDICATE�, TVPE I, CLASS 1(QEAR) OR CLASS 2(TINTED) AS
INDICATEq QUALITV-�3.
C. HEAT-STRENGTHENED ROAT GLASS: ASTM C 1048, KIND HS (HEAT STRENGTHENE��, TVPE I,
GONOITION A(UNGOATED) UNLE55 OTHERW ISE INDICATED, TYPE I, CLA55 1(CLEAR) OR GLASS 2
(TINTE�) AS INDICATE�. QUALITY-Q3.
1.9 LAMINATED GLA55
A. LAMINATED GLA55: ASTM C 1112. USE MATERIALS THAT HAVE A PROVEN RECORD OF NO TENDENCV
TO BUBBLE, DISCOLOR, OR LOSE PHVSICAL AND MECHANICAL PROPERTIES AFTER FABRICATION
ANDINSTALLATION.
1.10 GLAZING SEALANTS
A.GENERAL:
1. COMPATIBILITV: COMPATIBLE W ITH ONE ANOTHER AND W ITH OTHER MATERIALS THEV CONTACT,
INCW DING GLASS PROOUCTS, SEALS OF INSl1LATING GLASS UNITS, AND GLAZING CHANNEL
SUBSTRATES, UNDER CONDITIONS OF SERVICE AND APPLICATION. AS DEMONSTRATED BV
SEAL4NT MANUFACTURER BASED ON TESTING AND FlELD EXPERIENCE.
2 SUITABILITV'. COMPLV WITH SEALANTAND GLA55 MANUFACTURERS' WRITTEN INSTRUCTIONS
FOR SELECTING GLAZING SEALANTS SUITABLE FOR APPLICATIONS INDICATE� AND FOR
CONDITIONS EXISTING AT TIME OF INSTALLATION.
3. COLORS OF EXPOSEO GLAZING SEALANTS: AS SELECTEO BV ARCHITECT FROM
MANUFACTURER'S Fl1LL RANGE.
1.11 MISCELLANEOUS GLAZING MATERIALS
A. GENERAL PROVIDE PRODUCTS OF MATERIAL, SIZE, AND SHAPE COMPLVING WITH REFERENCED
GLAZING STANDARD, WITH REQUIREMENTS OF MANUFACTURERS OF GLASS AND OTHER GLAZING
MATERIALS FOR APPLICATION INDICATED, AND W ITH A PROVEN RECORD OF COMPATIBILITV W ITH
SURFACES CONTACTED IN INSTALLATION.
12 FABRICATION OF GLAZING UNITS
A FABRICATE GLAZING UNITS IN SRES REQUIRED TO RT OPENINGS INDICATED FOR PROJECT, WITH
EDGE AND FACE CLEARANCES, EDGE ANO SURFACE CONOITIONS, AND BITE COMPLVING W ITH
WRITTEN INSTRUCTIONS OF PRODUCT MANUFACTURER AND REFERENCED GLAZING
PUBLICATIONS, TO COMPLV WITH SVSTEM PERFORMANCE REQUIREMENTS
PART2-EXECUTION
21 EXAMINATION
A EXAMME FRAMING, GLAZMG CHANNELS, AND STOPS, W ITH INSTALLER PRESENT. PROCEED WITH
INSTALLATION ONLV AFTER UNSATISFACTORYCONDITIONS HAVE BEEN CORRECTED.
22 PREPARATION
A. CLEAN GLAZMG CHANNELS AND OTHER FRAMING MEMBERS RECEIVING GLASS IMMEDIATELY
BEFORE GLAZING. REMOVE COATINGS NOT FIRMLV BONDEO TO SUBSTR4TE5. EXAMINE GLAZING
UNITS TO LOCATE E%TERIOR AND WTERIOR SURFACES LABEL OR MARK UNITS AS NEEDE� SO
THAT EXTERIOR AND IMERIOR SURFACES ARE READILV IDENTIFlABLE DO NOT USE MATERIALS
THAT LEAVE VISIBLE MARKS IN THE COMPLETED WORK.
2.3 GLAZING, GENERAL
A. COMPLV WITH COMBMED WRITTEN INSTRUCTIONS OF MANUFACTURERS OF GLASS, SEALANTS,
GASKETS, AND OTHER GLAZING MATERIALS, UNLESS MORE STRINGENT REpl11REMENTS ARE
INDICATEq INCLUDING THOSE IN REFERENCED GLAZING PUBLICATIONS.
B. PROTECT GLASS EDGES FROM DAMAGE DURING HANDLING AND INSTALLATION. REMOVE DAMAGED
GLA55 FROM PROJECT SITE AND LEGALLV OISPOSE OF OFF PROJECT SITE. �AMAGED GLA55
INCLUDES GLASS W ITH EDGE �AMAGE OR OTHER IMPERFECTIONS THAT, WHEN INSTALLED, COULD
WEAKEN GLA55, IMPAIR PERFORMANCE, OR IMPAIR APPEARANCE.
C. INSTALL SETTING BLOCKS IN SILL RABBETS, SIZED AND LOCATED TO COMPLV WITH REFERENCED
GLAZING PUBLICATIONS, UNLESS OTHERWISE REQUIRE� eV GLASS MANUFACTURER. SET BLOCKS
IN THIN COURSE OF COMPATIBLE SEALANT SUITABLE FOR HEEL BEA�.
0. PROVIDE SPACERS FOR GLA55 LITES WHERE LENGTH PWS W IOTH IS LARGER THAN 50 WCHES
(1270 MM}
1. LOCATE SPACERS DIRECTLY OPPOSITE EACH OTHER ON BOTH INSIDE AND OUTSIDE FACES OF
GLASS. INSTALL CORRECT SIZE AND SPACING TO PRESERVE REpUIRED FACE CLEAR4NCE5,
UNLESS GASKETS AND GLAZING TAPES ARE USED THAT HAVE DEMONSTRATED ABILITV TO
MAINTAIN RE�UIRED FACE CLEAftANCES AND TO COMPLY WITH SYSTEM PERFORMANCE
REQUIREMENTS.
2. PROVIDE 1/8-INCH (3-MM) MINIMUM BITE OF SPACERS ON GLASS AND USE THICKNESS EQUAL TO
SEALANT W IDTH. W ITH GLAZING TAPE, USE THICKNESS SLIGHTLV LESS THAN FlNAL
COMPRESSEO THICKNESS OF TAPE.
E. PROVIDE EDGE BLOCKWG WHERE INDICATED OR NEEDED TO PREVENT GLASS LITES FROM MOVMG
SIDEWAVS IN GLAZING CHANNEL, AS RECOMMEN�ED IN WRITING BV GLASS MANUFACTURER AN�
ACCORDING TO REQUIREMENTS IN REFERENCED GLAZING PUBLICATIONS.
F. SET GLASS LITES IN EACH SERIES WITH UNIFORM PATTERN, DRAW, BOW, AND SIMILAR
CHARACTERISTICS.
G. WHERE WEDGE-SHAPED GASKETS ARE DRNEN INTO ONE SIDE OF CHANNEL TO PRESSURIZE
SEALANT OR GASKET ON OPPOSITE SIDE, PROVIDE ADEQUATE ANCHORAGE SO GASKET CANNOT
WALK OUT WHEN INSTALLATION IS SUBJECTED TO MOVEMENT.
H. Spl1ARE CUT W EOGE-SHAPED GASKETS AT CORNERS AND W STALL GASKETS IN A MANNER
RECOMMENDED BY GASKET MANUFACTURER TO PREVENT CORNERS FROM PULLMG AWAV; SEAL
CORNER JOINTS AND BUTT JOINTS WITH SEALANT RECOMMENDED BV GASKET MANUFACTURER.
[.y xe �[.� , uxf s�vvaH r_v� i, �h
2.4 GASKET GLAZING DRV
( )
A. Cl1T COMPRESSION GASKETS TO LENGTHS RECOMMENOED BV GASKET MANl1FACTURER TO FIT
OPENINGSE%ACTLV WITHALLOWANCEFORSTRETCHDURINGINSTALLATION.
B. INSERT SOFT COMPRESSION GASKET BETW EEN GLASS AND FRAME OR FlXED STOP SO IT IS
SECURELV IN PLACE WITH JOINTS MITER CUT AND BON�ED TOGETHER AT CORNERS.
G INSTALLATION W ITH DRIVE-IN W EDGE GASKETS: CENTER GLASS LITES IN OPENINGS ON SETTING
BLOCKS, AND PRESS FlRMLV AGAINST SOFT COMPRESSION GASKET BV MSERTING DENSE
COMPRESSION GASKETS FORMED ANO INSTALLED TO LOCK IN PLACE AGAINST FACES OF
REMOVABLE STOPS. START GASKET APPLICATIONS AT CORNERS AND WORK TOWARD CENTERS
OF OPENINGS. COMPRESS GASKETS TO PRODUCE A W EATHERTIGHT SEAL W ITHOUT DEVELOPING
BENDING STRESSES IN GLA55. SEAL GASKET JOINTS W ITH SEALANT RECOMMENDED BV GASKET
MANUFACTURER.
D. WSTALLATION W ITH PRESSUREGLAZING STOPS: CENTER GLASS LITES IN OPENINGS ON SETTING
BLOCKS, AND PRE55 FIRMLV AGAWST SOFT COMPRESSION GASKET. INSTALL DENSE
COMPRESSION GASKETS AND PRESSURE-GLAZING STOPS, APPLVING PRESSURE UNIFORMLV TO
COMPRESSION GASKETS. COMPRESS GASKETS TO PRO�UCE A WEATHERTIGHT SEAL WITHOUT
DEVELOPING BENDING STRESSES IN GLASS. SEAL GASKETJOINTS WITH SEALANT RECOMMENDED
BVGASKETMANUFACTURER.
E INSTALL GASKETS 50 THEY PROTRUDE PAST FACE OF GLAZING STOPS.
25 SEALANT GLAZING (WET)
A. WSTALL CONTINUOUS SPACERS, OR SPACERS COMBMEo W ITH CVLINDRICAL SEALANT BACKING,
BETWEEN GLASS LITES AND GLAZWG STOPS TO MAINTAIN GLASS FACE CLEARANCES AND TO
PREVENT SEALANT FROM EXTRl1DING MTO GLASS CHANNELAND BLOCKING WEEP SVSTEMS UNTIL
SEALANTS CURE. SECURE SPACERS OR SPACERS AND BACKINGS IN PLACE AND IN POSITION TO
CONTROL DEPTH OF INSTALLED SEALANT RELATNE TO EDGE CLEARANCE FOR OPTIMUM SEALANT
PERFORMANCE. FORCE SEALANTS WTO GLAZING CHANNELS TO ELIMINATE VOIDS AND TO ENSURE
COMPLETE W ETTING OR eOND OF SEALANT TO GLASS AND CHANNEL SURFACES. TOOL EXPOSED
SURFACES OF SEALANTS TO PROVIDE A SUBSTANTIAL WASH AWAY FROM GLA55.
26 CLEANING AND PROTECTION
A. IMMEDIATELVAFTER INSTALLATION REMOVE NONPERMANENT LABELS AND CLEAN SURFACES.
PROTECTGLASS FROM CONTACT WITH CONTAMINATMG SUBSTANCES RESULTING FROM
CONSTRUCTION OPERATIONS. EXAMINE GLASS SURFACES ADJACENT TO OR BELOW EXTERIOR
CONCRETE AND OTHER MASONRV SURFACES AT FRE�UENT INTERVALS DURING CONSTRUCTION,
BUT NOT LESS THAN ONCE A MONTH, FOR BUILDUP OF DIRT, SCUM, ALKALME DEPOSITS, OR
STAINS. REMOVE AN� REPLACE GLASS THAT IS DAMAGED DURING CONSTRUCTION PERIOD" WASH
GLASS ON BOTH EXPOSED SURFACES NOT MORE THAN FOUR DAVS BEFORE DATE SCHEDULED
FOR WSPECTIONS THAT ESTABLISH �ATE OF SUBSTANTIAL COMPLETION. WASH GLASS AS
RECOMMENOED IN WRITING BV GLASS MANUFACTl1RER.
F9 XNIG].DFYYi[�: W� Q-91:i1LN i11:L1A�41�L1� y:L1�511.[�3
PART7-GENERAL
1.iRELATE�DOCUMENTS
A. DRAW INGS AND GENERAL PROVISIONS OF THE CONTRACT, INC W DING GENERAL AND
SUPPLEMENTARV CONDITIONS AND DIVISION 01 SPECIFlCATION SECTIONS, APPLV TO THIS SECTION.
1.2SUMMARV
A. SECTION INCWDES:
1. NON-LOAD-BEARING STEEL FRAMWG SVSTEMS FOR INTERIOR GVPSUM BOARD ASSEMBLIES.
2. SUSPENSION SVSTEMS FOR INTERIOR GVPSUM CEILINGS, SOFFITS, ANO GRID SVSTEMS.
PART2-PROOUCTS
2.iPERFORMANCERE�UIREMENTS
A FlRETEST-RESPONSE CHARACTERISTICS FOR RRERESISTANCERATED ASSEMBLIES THAT
INCORPORATE NON-LOAD-BEARING STEEL FRAMING, PROVIDE MATERIALS AND CONSTRUCTION
IDENTICAL TO THOSE TESTED IN ASSEMBLV INDICATE�. ACCORDING TO ASTM E 119 BV AN
INDEPENDENT TESTING AGENCV.
B. STC-RATED ASSEMBLIES: FOR STC-RATE� ASSEMBLIES. PROVIDE MATERIALS AN� CONSTRUCTION
IDENTICAL TO THOSE TESTED IN ASSEMBLV INDICATE�. ACCORDING TO ASTM E 90 AND CLASSIFIED
ACCORDING TO ASTM E 413 BV AN INDEPENDENT TESTING AGENCV.
22FRAMINGSVSTEMS
A. FRAMING MEMBERS, GENERAL COMPLV W ITH ASTM C]54 FOR CONDITIONS INDICATED.
1. STEEL SHEET COMPONENTS: COMPLY W ITH ASTM C fi45 REQUIREMENTS FOR METAL UNLE55
OTHERW ISE INDICATED.
2. PROTECTNE COATING. [ASTM A 653/A 653M, G40 (Z120)] �ASTM A 653IA 653M, G60 (Z180)� �COATING
W ITH EQUIVALEM CORROSION RESISTANCE OF ASTM A 653IA 653M, G40 (Z120)], HOT-DIP
GALVANIZED UNLE55 OTHERW ISE INDICATED.
B. STUDS AND RUNNERS: ASTM C 645.USE EITHER STEEL STUDS AND RUNNERS OR DIMPLE� STEEL
STU�S ANO RUNNERS. DEFLECTION TRACK: STEEL SHEET TOP RUNNER MANUFACTURED TO
PREVENT CRACKING OF FINISHESAPPLIE� TO INTERIOR PARTITION FRAMING RESULTING FROM
DERECTION OF STRUCTURE ABOVE; IN THICKNESS NOT LESS THAN INDICATED FOR STUDS AND IN
W IDTH TO ACCOMMODATE DEPTH OF STUDS.
G FIRESTOP TRACKS�. TOP RUNNER MANUFACTURED TO ALLOW PARTITION HEADS TO EXPAN� AND
CONTRACT W ITH MOVEMENT OF THE STRUCTURE W HILE MAINTAINING CONTINUITY OF FlRE
RESISTANCE-RATED ASSEMBLV INDICATED; IN THICKNESS NOT LESS THAN INDICATE� FOR STUDS
AND IN WIDTH TO ACCOMMODATE DEPTH OF STUDS.
2.3 SUSPENSION SYSTEMS
A. TIE W IRE: ASTM A 641IA 641M, CLASS 1 ZINC COATING, SOFT TEMPER, 0.062-INCH- (1.59-MM-)
DIAMETER W IRE, OR DOUBLE STRAN� OF 0.048- WCH-(1 21-MM-) DIAMETER W IRE.
B.HANGERATTACHMENTSTOCONCRETE:
1. ANCHORS'. FABRICATED FROM CORROSION-RESISTANT MATERIALS WITH HOLES OR LOOPS FOR
ATTACHING W IRE HANGERS AND CAPABLE OF SUSTAINING. W ITHOUT FAI W RE, A LOAD EpUAL
TO 5 TIMES THAT IMPOSED BV CONSTRUCTION AS DETERMINED BV TESTWG ACCORDING TO
ASTM E 488 BV AN INDEPENDENT TESTING AGENCY.
2 POW�ER-ACTUATED FASTENERS�. Sl11TABLE FOR APPLICATION INDICATED, FABRICATED FROM
CORROSION-RESISTANT MATERIALS WITH CLIPS OR OTHER DEVICES FORATTACHING HANGERS
OF TYPE INDICATED, AN� CAPABLE OF SUSTAINING, WITHOUT FAILURE, A LOAD EQUAL TO �10]
qNSERT NUMBER� TIMES THAT IMPOSED BV CONSTRUCTION AS DETERMINED BV TESTING
ACCORDING TO ASTM E 1190 BV AN INDEPENDENT TESTW G AGENCV.
A. W IRE HANGERS: ASTM A 641IA 641M, CLASS 1 ZINC COATING, SOFT TEMPER, 0.i61NCH (4.12
MM) IN DIAMETER.
2 4 AUXILIARV MATERIALS
A. GENERAL PROVIDE AUXILIARY MATERIALS THAT COMPLV W ITH REFERENCED INSTALLATION
STANDARDS. FASTENERS FOR METAL FRAMING: OF TVPE, MATERIAL, SIZE, CORROSION
RESISTANCE, HOLDWG POWER, AND OTHER PROPERTIES REQUIRED TO FASTEN STEEL MEMBERS
TO SU85TRATE.
PART 1- EXECUTION
3.1 EXAMINATION
A EXAMME AREAS AND SUBSTRATES, WITH INSTALLER PRESENT, AND INCLU�ING WELDEO HOLLOW-
METAL FRAMES, CAST-IN ANCHORS, AND STRUCTURAL FRAMING, FOR COMPLIANCE W ITH
REQUIREMENTS AND OTHER CONDITIONS AFFECTING PERFORMANCE OF THE WORK. PROCEED
WITH INSTALLATION ONLV AFTER UNSATISFACTORV CONDITIONS HAVE BEEN CORRECTED.
3 2 PREPARATION
A. SUSPENDED ASSEMBLIES: COORDINATE W STALLATION OF SUSPENSION SVSTEMS W ITH
INSTALLATION OF OVERHEAD STRUCTURE TO ENSURE THAT INSERTS AND OTHER PROVISIONS FOR
ANCHORAGES TO BUILDING STRUCTURE HAVE BEEN INSTALLED TO RECEIVE HANGERS AT SPACMG
REQUIRED TO SUPPORT THE W ORK AND THAT HANGERS W ILL DEVELOP THEIR FULL STRENGTH.
1. FURNISH CONCRETE INSERTS AND OTHER �EVICES INDICATED TO OTHER TRADES FOR
INSTALLATION IN ADVANCE OF TIME NEEDEO FOR COOROINATION ANO CONSTRUCTION.
B. COORDINATION wITH SPRAVEo RRE-RESISTNE MATERIALS�. BEFORE SPRAVED FlRE-RESISTIVE
MATERIALS ARE APPLIEO. ATTACH OFFSET ANCHOR PLATES OR CEILING RUNNERS (TRACKS) TO
Sl1RFACES INDICATED TO RECENE SPRAVE� FIRE-RESISTIVE MATERIALS. WHERE OFFSETANCHOR
PLATES ARE REQUIRED, PROVIDE CONTINUOUS PLATES FASTENED TO BUILDING STRUCTURE NOT
MORE THAN 241NCHE5 (610 MM) O.C. AFTER SPRAVEO FIRE-RESISTIVE MATERIALSAREAPPLIEO,
REMOVE THEM ONLV TO ExTENT NECESSARV FOR INSTALLATION OF NON-LOAD-BEARING STEEL
FRAMING. DO NOT REDUCE THICKNESS OF RRERESISTNE MATERIALS BELOW THAT RE�UIRED FOR
RRE-RESISTANCE RATINGS INDICATED. PROTECT ADJACENT FlRERESISTNE MATERIALS FROM
DAMAGE
3.31NSTALLATION,GENERAL
A. INSTALLATION STANDARD: ASTM C]54. GVPSUM BOARD ASSEMBLIES: ALSO COMPLY W ITH
REQUIREMENTS IN ASTM C 840 THAT APPLV TO FRAMING INSTALLATION. INSTALL SUPPLEMENTARV
FRAMING, AN� BLOCKING TO SUPPORT FlXTURES, EQUIPMENT SERVICES, HEAVV TRIM, GRAB BARS,
TOILET ACCESSORIES, FURNISHINGS, OR SIMILAR CONSTRUCTION. INSTALL BRACING AT
TERMINATIONS IN ASSEMBLIES. DO NOT BRIDGE BUILDING CONTROL AND EXPANSION JOINTS W ITH
NON-LOAD-BEARING STEEL FRAMING MEMBERS. FRAME BOTH SIDES OF JOINTS INDEPENDENTLV.
3.4 INSTALLING FRAMED ASSEMBLIES
A. INSTALL FRAMING SVSTEM COMPONENTS ACCORDING TO SPACINGS INDICATE�, BUT NOT GREATER
THAN SPACWGS RE�UIRED BV REFERENCED INSTALLATION STANDARDS FOR ASSEMBLVTVPES.
B. INSTALL TRACKS (RUNNERS) AT FLOORS AND OVERHEAD SUPPORTS. EXTEN� FRAMING FULL HEIGHT
TO STRUCTURAL SUPPORTS OR SUBSTRATES ABOVE SUSPEN�ED CEILINGS EXCEPT W HERE
PARTITIONS ARE INDICATED TO TERMINATE AT SUSPENDED CEILINGS. CONTINUE FRAMING AROUND
�UCTS PENETRATING PARTITIONS ABOVE CEILING.
C. DIRECT FURRING:
1. SCREW TO wOOD FRAMING.
2. ATTACH TO CONCRETE OR MASONRV WITH STUB NAILS, SCREWS DESIGNED FOR MASONRV
ATTACHMENT, OR POW DER-DRNEN FASTENERS SPACED 24 INCHES (610 MM) O C.
O. Z-FURRING MEMBERS�.
1. ERECT WSULATION. SPEQRED M SECTION 0]2100 "THERMAL INSULATION," VERTICALLYAND
HOLD IN PLACE W ITH Z-FURRING MEMBERS SPACED [24 INCHES (610 MM)� [600 MM� O C.
2 EXCEPTAT EXTERIOR CORNERS, SECURELYATTACH NARROW FL4NGES OF FURRING MEMBERS
TO WALL W ITH CONCRETE STUB NAILS, SCREWS DESIGNED FOR MASONRV ATTACHMENT, OR
POWDER-DRNEN FASTENERS SPACE� 241NCHES (610 MM) O C.
3. AT EXTERIOR CORNERS. ATTACH W IDE FLANGE OF FURRING MEMBERS TO WALL W ITH SHORT
RANGE EXTEN�ING BEVOND CORNER; ON ADJACENT WALL SURFACE, SCREW-ATTACH SHORT
FLANGE OF Fl1RRING CHANNEL TO W E8 OF ATTACHED CHANNEL AT WTERIOR CORNERS,
SPACE SECON � MEMBER NO MORE THAN 12 INCHES (305 MM) FROM CORNER AND CUT
INSULATION TO RT.
E. INSTALLATION TOLERANCE�. INSTALL EACH FRAMING MEMBER SO FASTENING SURFACES VARV NOT
MORE THAN 1/e WCH (3 MM) FROM THE PLANE FORMED BV FACES OF ADJACENT FRAMWG.
3.S INSTALLING SUSPENSION SVSTEMS
A. INSTALL SUSPENSION SVSTEM COMPONENTS ACCORDING TO SPACINGS INDICATED, BUT NOT
GREATER THAN SPACWGS RE�UIRED BV REFERENCED INSTALLATION STANDARDS FOR ASSEMBLV
TYPES.
B.ISOLATE SUSPENSION SVSTEMS FROM BUILDING STRUCTURE WHERE THEVABUTORARE
PENETRATED BV BUILDING STRUCTURE TO PREVENT TRANSFER OF LOADING IMPOSED BV
STRUCTURALMOVEMENT.
G SUSPEND HANGERS FROM BUILDMG STRUCTURE AS FOLLOWS: INSTALL HANGERS PLUMB AND FREE
FROM CONTACT WITH INSULATION OR OTHER 08JECTS WITHW CEILING PLENUM THATARE NOT
PART OF SUPPORTING STRUCTURAL OR SUSPENSION SYSTEM.
�. FIRE-RESISTANCE-RATE� ASSEMBLIES: WIRE TIE FURRING CHANNELSTO SUPPORTS.
E. SEISMIC eRACING�. SwAV-BRACE SUSPENSION SVSTEMS WITH HANGERS USED FOR SUPPORT.
F. GRID SUSPENSION SVSTEMS: ATTACH PERIMETER WALL TRACK OR ANGLE WHERE GRID SUSPENSION
SVSTEMS MEET VERTICAL SURFACES. MECHANICALLV JOIN MAIN BEAM AND CROSS-FURRING
MEMBERS TO EACH OTHER AND BUTT-CUT TO FlT INTO WALL TRACK.
G. INSTALLATION TOLERANCES: INSTALL SUSPENSION SVSTEMS THAT ARE LEVEL TO W ITHIN 1I8 WCH IN
12 FEET (3 MM IN 3$ M) MEASURED LENGTHW ISE ON EACH MEMBER THAT WILL RECENE FINISHES
AND TRANSVERSELY BETW EEN PARALLEL MEMBERS THAT W ILL RECEIVE FlNISHES.
SECTION 092900 - GYPSUM BOARD
PART1-GENERAL
1.1RELATEDDOCUMENTS
A.DRAWINGSAN�GENERALPROVISIONSOFTHECONTRACT INCLUDINGGENERALAND
SUPPLEMENTARV CON�ITIONS AND DNISION 01 SPECIFICATION SECTIONS, APPLV TO THIS SECTION.
12SUMMARV
A. SECTION MCLUDES:
1. INTERIOR GVPSUM BOARD.
2. TILE BACKING PANELS.
1.3 ACTION SUBMITTALS
A. PRODUCT DATA: FOR EACH TVPE OF PRODl1CT.
1 4 DELIVERV, STORAGE AND HANDLMG
A. STORE MATERIALS INSIDE UNDER COVER AN� KEEP THEM DRV AND PROTECTED AGAINST WEATHER,
CONDENSATION, DIRECT Sl1NLIGHT, CONSTRUCTION TRAFFIC, AND OTHER POTENTIAL CAUSES OF
DAMAGE. STACK PANELS FLAT AND SUPPORTED ON RISERS ON A FLAT PLATFORM TO PREVENT
SAGGING.
1.5 FIELD CONDITIONS
A. ENVIRONMENTAL LIMITATIONS: COMPLY WITH ASTM C 840 RE�UIREMENTS OR GVPSUM BOARD
MANUFACTURER'S WRITTEN RECOMMENDATIONS, WHICHEVER ARE MORE STRINGENT.
B. DO NOT INSTALL PAPER-FACED GVPSUM PANELS UNTIL INSTALLATION AREAS ARE ENCLOSEO AND
CONDITIONED.
C. DO NOT INSTALL PANELS THAT ARE WET, THOSE THAT ARE MOISTURE DAMAGED, AND THOSE THAT
ARE MOL� �AMAGE�.
1. INDICATIONS THAT PANELS ARE WET OR MOISTURE DAMAGED INCLUDE, BUT ARE NOT LIMITED
TO, DISCOLORATION, SAGGING, OR IRREGULAR SHAPE.
21NDICATIONS THAT PANELS ARE MOLD DAMAGED INCWDE, BUT ARE NOT LIMITED TO, FUZZV OR
SPLOTCHV SURFACE CONTAMINATION AND DISCOLORATION.
PART2�PRODUCTS
21PERFORMANCEREQUIREMENTS
A FlRERESISTANCERATEDASSEMBLIES FOR FlRERESISTANCERATED ASSEMBLIES, PROVIDE
MATERIALS AND CONSTRUCTION IDENTICAL TO THOSE TESTE� IN ASSEMBLV INDICATED
ACCORDING TO ASTM E 119 BV AN INDEPENDENT TESTING AGENCV.
B. STC-RATED ASSEMBLIES'. FOR STC-RATED ASSEMBLIES, PROVIDE MATERIALS AND CONSTRUCTION
IDENTICAL TO THOSE TESTE� IN ASSEMBLV INDICATED ACCORDING TO ASTM E 90 AND CLASSIFlED
ACCORDING TO ASTM E 413 BV AN INDEPENDENT TESTING AGENCV.
G LOW-EMITTING MATERIALS: FOR CEILING AND WALL ASSEMBLIES, PROVIDE MATERIALS AND
CONSTRUCTION IDENTICAL TO THOSE TESTED IN ASSEMBLV AND COMPLVING W ITH THE TESTING
AND PRODUCT REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF HEALTH SERVICES'
"STANDARD PRACTICE FOR THE TESTING OF VOLATILE ORGANIC EMISSIONS FROM VARIOUS
SOURCES USING SMALL-SCALE ENVIRONMENTAL CHAMBERS."
2 2 TILE BACKING PANELS
A. GLASS-MAT, WATER-RESISTANT BACKING BOARD: ASTM C 1178/C 11]BM, WITH MANUFACTURER'S
STANDARD EDGES. CORE: SIS WCH (iS9 MM), TYPE X, MOLD RESISTANCB ASTM D 32�3, SCORE OF
10 AS RATED ACCORDING TO ASTM D 3214.
B. CEMENTITIOUS eACKER UNITS: ANSI A118.9AND ASTM C 12880R 1325, WITH MANUFACTURER'S
STANDARD EDGES.THICKNESS: 5/8 WCH (iS9 MM). MOLD RESISTANCE'. ASTM D 32�3, SCORE OF 10
AS RATE� ACCORDING TO ASTM D 32]4.
C. WATER-RESISTANT GVPSUM eACKING eOARD: ASTM C 1396IC 1396M, W ITH MANUFACTURER'S
STANDARD EDGES.CORE'. 5/S INCH (15.9 MM�, TVPE X.
2 3 AUXILIARV MATERIALS
A. GENERAL: PROVI�E AUXILIARV MATERIALS THAT COMPLV W ITH REFERENCED INSTALLATION
STANDARDS AND MANUFACTURER'S WRITTEN RECOMMENDATIONS.
B. LAMINATING AOHESNE AOHESIVE OR JOINT COMPOUND RECOMMENDED FOR DIRECTLV A�HERING
GYPSUM PANELS TO CONTINUOUS SUBSTRATE.
Q SOUND ATTENUATION BLANKETS: ASTM C 665, TVPE I(BLANKETS W ITHOUT MEMBRANE FAQNG)
PRODl10ED BV COMBINING THERMOSETTING RESWS WITH MINERAL FIBERS MANUFACTURED FROM
GLASS, SLAG WOOL, OR ROCK WOOL.
D. ACOUSTICAL JOINT SEALANT: MANUFACTURER'S STANDARD NONSAG, PAINTABLE, NONSTAINING
LATEX SEALANT COMPLVING W ITH ASTM C 834. PRODUCT EFFECTIVELV REDUCES AIRBORNE SOUN�
TRANSMISSION THROUGH PERIMETER JOINTS AND OPENINGS IN BUILDING CONSTRUCTION AS
DEMONSTRATED BV TESTING REPRESENTATNE ASSEMBLIES ACCORDING TO ASTM E 90.
PART 3 - EXECUTION
3.1 EXAMINATION
A EXAMME AREAS AND SUBSTRATES INCLUDING W ELDE� HOLLOW-METAL FRAMES AND FRAMING,
W ITH INSTALLER PRESENT, FOR COMPLIANCE W ITH REQUIREMENTS AND OTHER CONDITIONS
AFFECTWG PERFORMANCE. EXAMINE PANELS BEFORE INSTALLATION. REJECT PANELS THATARE
WET, MOISTURE DAMAGED, AND MOLD DAMAGED. PROCEEO WITH INSTALLATION ONLV AFTER
UNSATISFACTORV CONDITIONS HAVE BEEN CORRECTED.
32APPLVING AND FINISHING PANELS, GENERAL
A. STGRATED ASSEMBLIES�. SEAL CONSTRUCTION AT PERIMETERS. BEHIND CONTROL JOINTS, AND AT
OPENINGS AND PENETR4TIONS WITH A CONTINUOUS BEA� OF ACOl15TICAL SEALANT. WSTALL
ACOUSTICAL SEALANT AT BOTH FACES OF PARTITIONS AT PERIMETERS AN� THROUGH
PENETRATIONS. COMPLV W ITH ASTM C 919 AND W ITH MANUFACTURER'S W RITTEN
RECOMMENDATIONS FOR LOCATING EDGE TRIM AND CLOSING OFF SOUND-FLANKING PATHS
AROUND OR THROUGH ASSEMBLIES, INCLUDING SEALING PARTITIONS ABOVE ACOUSTICAL
CEILINGS.
3.31NSTALLING TRIM ACCESSORIES
A. GENERAL�. FOR TRIM WITH BACK FLANGES INTENDED FOR FASTENERS, ATTACH TO FRAMING WITH
SAME FASTENERS USED FOR PANELS.OTHERWISE, ATTACH TRIM ACCORDWG TO
MANUFACTURER'S WRITTEN INSTRUCTIONS.
B. CONTROL JOINTS: INSTALL CONTROL JOINTS ACCOR�ING TO ASTM C 840 AND IN SPECIFIC
LOCATIONS APPROVED BV ARCHITECT FOR VISUAL EFFECT.
C. INTERIOR TRIM: INSTALL IN THE FOLLOW ING LOCATIONS�. CORNERBEAD: USE AT OUTSIDE CORNERS
UNLE55 OTHERW ISE INDICATED. U-BEAD: USE AT EXPOSED PANEL EDGES.
3.4 FINISHING GYPSUM BOARD
A. GENERAL TREAT GYPSUM BOARD JOINTS, INTERIOR ANGLES, EDGE TRIM, CONTROL JOINTS,
PENETRATIONS, FASTENER HEAOS, SURFACE DEFECTS, AND ELSEWHERE AS REQUIRED TO
PREPARE GVPSUM BOARD SURFACES FOR �ECORATION. PROMPTLV REMOVE RESIDUAL JOINT
COMPOUNDFROM ADJACENTSURFACES.
B. GLASS-MAT GYPSUM SHEATHWG BOAR�: FINISH ACCORDING TO MANUFACTURER'S WRITTEN
WSTRUCTIONS FOR USE AS EXPOSED SOFFIT BOARD. GLA55-MAT FACED PANELS: FINISH
ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. CEMENTITIOUS BACKER 11NITS: FINISH
ACCORDWG TO MANUFACTURER'S WRITTEN INSTRUCTIONS.
3.5 PROTECTION
A.PROTECTADJACENTSURFACESFROM �RVWALLCOMPOUNDANDPROMPTLVREMOVEFROM
FLOORS AND OTHER NON-DRVWALL SURFACES. REPAIR SURFACES STAMED, MARRED, OR
OTHERWISE DAMAGED DURING DRVWALL APPLICATION.
B. PROTECT INSTALLED PRODUCTS FROM DAMAGE FROM WEATHER, CONDENSATION, DIRECT
SUNLIGHT, WNSTRUCTION, AND OTHER CAUSES DURWG REMAINDER OF THE CONSTRUCTION
PERIOD.
C. REMOVE AND REPLACE PANELS THAT ARE W ET, MOISTURE DAMAGED, AN� MOLD DAMAGED.
INDICATIONS THAT PANELS ARE W ET OR MOISTURE DAMAGED INCLUDE, BUT ARE NOT LIMITED TO,
DISCOLORATION, SAGG WG, OR IRREGULAR SHAPE INDICATIONS THAT PANELS ARE MOLD
DAMAGED INC W DE, BUT ARE NOT LIMITED TQ FUZZV OR SPLOTCHV SURFACE CONTAMINATION
AND DISCOLORATION.
�
�
/ ♦ 1
�
INDUSTRIOUS
COWORKING
880 W MONON GREEN BLVD
CARMEL, IN 46032
OWNEPRENANT
INDUSTRIOUS
215PARKAVES,4E1300
NEW YORK, NY 1 W03
ARCXITECT OF HECOPD
NORX
325 N LASALLE Si- SOIiE SCO
CHICAGO. IL 60654
PEiER.DUBWCmNORR-COM
312-0242400
MEP ENGINEER
MEENGINEERS
29 WEST 38iH SiREEi, SiH FLOOR
NEW YORK. NY 10018
CONiACi: BRIAN SHASSIAN
BBIANSHASSIANC�.ME-ENGINEER$_COM
JOHN HIGGINS
JOHN.HIGGWS(�MEENGINEERS.COM
�212J 44]-6]]0 PHONE
LIGHTING DESIGNER
REGENCY
9261 JOkDAN AVE
CHAiSWORiH, CA
800-28d-202J
ISSUE DATES
REV. DAiE DESCRIPiION
06/OS/2020 DD3
06/18l2020 CDvI
0]/06/2020 CDv2
O]/V/2020 100%/PERMIT
SEAL&SIGNATUNE
BY CHECK
BG PJ
BC PJ
eC Po
BC PJ
CARMEL CITY- 880 MONON GREEN
PRQIECT NUMBER
IND680MON
DRAWING TITLE
SPECIFlCATIONS
SCALE
1 1/2" = 1' 0"
SHEET NUMBER
A-905
oF
PROJECTNAME