HomeMy WebLinkAboutA907 SpecsSECTION 096813 -TILE CARPETING
PART1-GENERAL
1.iRELATEDDOCUMENTS
A. DRAW INGS AND GENERAL PROVISIONS OF THE CONTRACT, INC W DING GENERAL AND
SUPPLEMENTARV CONDITIONS AND DIVISION 07 SPECIFlCATION SECTIONS. APPLV TO THIS SECTION.
L2 SUMMARV
A. SECTION INCLUDES MODULAR, CARPET TILE.
7.3 ACTION SUBMITTALS
A. PRODUCT DATA FOR EACH TVPE OF PRODUCT.
1. INCLUDE MANl1FACTURER'S W RITTEN �ATA ON PHVSICAL CHARACTERISTICS, DURABILITV, AND
FADE RESISTANCE.
2. INCLUDE INSTALLATION RECOMMENDATIONS FOR EACH TYPE OF SU85TRATE.
B. SHOP DRAW INGS�. SHOW THE FOLLO W ING.
7. COLUMNS, DOORWAVS, ENCLOSING WALLS OR PARTITIONS, BUILT-IN CABWETS, AND LOCATIONS
W HERE CUTOUTS ARE REOUIRED IN CARPET TILES.
2. CARPET TILE TYPE, WLOR, AN� DVE LOT.
3. TYPE OF SUBFLOOR.
4. TYPE OF INSTALLATION.
5. PATTERN OF INSTALLATION.
6. PATTERN TYPE, LOCATION, AND DIRECTION.
]. PILE DIRECTION.
8. TVPE, COLOR, AN� LOCATION OF INSETS AND BOR�ERS.
9. TVPE, COLOR, AND LOCATION OF EDGE, TRANSITION, AND OTHER ACCESSORV STRIPS.
10. TRANSITION DETAILS TO OTHER FLOORING MATERIALS.
C. SAMPLES: FOR EACH OF THE FOLLOW WG PRODUCTS AND FOR EACH COLOR AND TEXTURE
REQUIRED. LABEL EACH SAMPLE W ITH MANUFACTURER'S NAME, MATERIAL DESCRIPTION, COLOR,
PATTERN, AND OESIGNATION INOICATED ON DRAWINGSAND IN SCHEDULES.
1. CARPETTILE: FULLSIZE SAMPLE.
2 EXPOSED EDGE, TRANSITION, AND OTHER ACCESSORV STRIPPING: 12-INCH- (300-MM-) LONG
SAMPLES.
D. PRODUCT SCHEDULE: FOR CARPET TILE. USE SAME DESIGNATIONS INDICATED ON DRAW INGS.
7.4 MFORMATIONAL SUBMITTALS
A. QUALIFlCATION DATA PoR INSTALLER.
6. PRODUCT TEST REPORTS: FOR CARPET TILE, FOR TESTS PERFORMED BV A QUALIFIED TESTING
AGENCY.
G SAMPLE WARRANTV: FOR SPEQAL WARRANTV.
1 S CLOSEOUT Sl1BMITTALS
A. MAINTENANCE DATA FOR CARPET TILES TO INCLUDE IN MAIMENANCE MANUALS. MCLU�E THE
FOLLO W ING:
1. METHODS FOR MAINTAINING CARPET TILE, INCLUDING CLEANING AN� STAIN-REMOVAL
PRODUCTS AND PROCEDURES AND MANUFACTURER'S RECOMMENDED MAINTENANCE
SCHE�ULE.
2. PRECAUTIONS FOR CLEANING MATERIALS AND METHODS THAT COUL� BE DETRIMENTAL TO
CARPET TILE.
1.6 MAINTENANCE MATERIAL SUBMITTALS
A. FURNISH E%TRA MATERIALS, FROM THE SAME PRODUCT RUN, THAT MATCH PRO�UCTS INSTALLE�
AND THAT ARE PACKAGED W ITH PROTECTIVE COVERING FOR STORAGE AND IDENTIRED W ITH
LABELS DESCRIBING WNTENTS. CARPET TILE: FULL-SIZE UNITS EQUAL TO 5 PERCENT OF AMOUNT
INSTALLED FOR EACH TVPE INDICATED, BUT NOT LESS THAN 10 SQ. VD. (8 3 SQ. M).
1 ] QUALITY ASSURANCE
A. FIRE-TEST-RESPONSE RATINGS'. W HERE INDICATED, PROVIDE CARPET TILE IDENTICAL TO THOSE OF
ASSEMBLIES TESTED FOR FIRE RESPONSE ACCOR�ING TO NFPA 253 BV A pUALIFIED TESTING
AGENCY.
1.8 DELNERV, STORAGE, AND HAN�LING
A. COMPLV W ITH CRI 104.
1.9 FlELD CONDITIONS
A. COMPLV WITH CRI104 FORTEMPERATURE, HUMIDITV. AND VENTILATION LIMITATIONS.
ENVIRONMENTAL LIMITATIONS�. DO NOT DELNER OR INSTALL CARPET TILES UNTIL SPACES ARE
ENCLOSED AND W EATHERTIGHT, W ET W ORK IN SPACES IS COMPLETE AND DRV, AND AMBIENT
TEMPERATURE AND HUMIDITV CONDITIONS ARE MAINTAMED AT OCCUPANCV LEVELS DURING THE
REMAINDER OF THE CONSTRUCTION PERIOD.
B. DO NOT INSTALL CARPET TILES OVER CONCRETE SLABS UNTIL SLABS HAVE CURE� AND ARE
SUFFICIENTLV DRY TO BOND W ITH ADHESNE AND CONCRETE SLABS HAVE PH RANGE
RECOMMEN�ED BV CARPET TILE MANUFACTURER. W HERE DEMOUNTABLE PARTITIONS OR OTHER
ITEMS ARE INDICATED FOR INSTALLATION ON TOP OF CARPET TILES, INSTALL CARPET TILES
BEFORE INSTALLING THESE ITEMS.
1.10WARRANTV
A. SPECIAL WARRANTV FOR CARPET TILES: MANUFACTURER AGREES TO REPAIR OR REPLACE
COMPONENTS OF CARPET TILE INSTALLATION THAT FAIL IN MATERIALS OR WORKMANSHIP W ITHIN
SPECIFIE� WARRANTV PERIOD.
PART2-PRODUGTS
21 INSTALLATION ACCESSORIES
A. TROWELABLE LEVELING AND PATCHING COMPOUNDS LATE%-MO�IFIED, HVDRAULIGCEMENT-BASED
FORMULATION PROVIDED OR RECOMMENDED BY CARPET TILE MANUFACTURER.
B. ADHESIVES'. WATER-RESISTANT, MILDEW-RESISTANT, NONSTAINING, PRESSURESENSITIVE TVPE TO
SUIT PRODUCTS AND SUBFLOOR CONDITIONS INDICATED, THAT COMPLIES W ITH FLAMMABILITV
REQUIREMENTS FOR INSTALLED CARPET TILE AND IS RECOMMENDED BV CARPET TILE
MANUFACTURER FOR RELEASABLE INSTALLATION.
C. METAL EDGEITRANSITION STRIPS: EXTRUDED ALUMINUM W ITH MILL FINISH OF PROFlLE AND W IDTH
SHOW N, OF HEIGHT REQUIRE� TO PROTECT EXPOSED EDGE OF CARPET, AND OF MAXIMUM
LENGTHS TO MINIMRE RUNNING JOINTS.
PART 3 - E%ECUTION
3.1 EXAMINATION
A. EXAMINE SUBSTRATES, AREAS, AND CONDITIONS, WITH INSTALLER PRESENT. FOR COMPLIANCE W ITH
REQUIREMENTS FOR MAXIMUM MOISTURE CONTENT, ALKALINITV RANGE, INSTALLATION
TOLERANCES, AND OTHER CONDITIONS AFFECTING CARPETTILE PERFORMANCE EXAMME CARPET
TILE FOR TYPE, COLOR, PATTERN, ANO POTENTIAL DEFECTS.
B. CONCRETE SUBFLOORS: VERIFV THAT CONCRETE SLABS COMPLV W ITH ASTM F]10 AN� THE
FOLLO W ING:
1. SLAB SUBSTR4TE5 ARE DRV AND FREE OF CURING COMPOUNDS, SEALERS, HAROENERS, ANO
OTHER MATERIALS THAT MAV WTERFERE W ITH ADHESNE 80ND. DETERMINE A�HESION AND
DRVNESS CHARACTERISTICS BY PERFORMING BOND AND MOISTURE TESTS RECOMMENDED BV
CARPETTILEMANUFACTURER.
2. SUBFLOORS ARE FREE OF CRACKS, RIDGES, DEPRESSIONS, SCALE, AND FOREIGN DEPOSITS.
D. FOR WOOD SUBROORS, VERIFVTHE FOLLOWING
1. UN�ERLAYMENT SURFACE IS FREE OF IRREGULARITIES AND SUBSTANCES THAT MAY INTERFERE
W ITH ADHESNE BOND OR SHOW THROUGH SURFACE.
E FOR PAINTE� SUBFLOORS, VEPoFV THE FOLLOW ING:
1. PERFORM BOND TEST RECOMMEN�ED IN WRITING BV ADHESIVE MANUFACTURER.
F. FOR RAISED ACCESS FLOORING SVSTEMS, VERIFV THE FOLLOW ING:
1. ACCESS FLOOR SUBSTRATE IS COMPATIBLE WITH CARPET TILE AND ADHESIVE IF ANV.
2. UN�ERLAYMENT SURFACE IS FLAT, SMOOTH, EVENLV PLANED, TIGHTLV JOINTED, AN� FREE OF
IRREGULARITIES, GAPS GREATER THAN 1/81NCH @ MM), PROTRUSIONS MORE THAN 1/321NCH
(0.8 MM), AND SUBSTANCES THAT MAV INTERFERE W ITH ADHESIVE BOND OR SHOW THROUGH
SURFACE.
G. PROCEE� W ITH INSTALLATION ONLV AFTER UNSATISFACTORV CON�ITIONS HAVE eEEN CORRECTE�.
32 PREPARATION
A. GENERAL COMPLV W ITH CRI 104. SECTION 62, "SITE CONDITIONS FLOOR PREPARATION," AND WITH
CARPETTILE MANl1FACTURER'S WRITTEN INSTALLATION INSTRl1CTIONS FOR PREPARING
SUBSTRATES IN�ICATE� TO RECENE CARPET TILE INSTALLATION. USE TRO W ELABLE LEVELING AND
PATCHING COMPOUNDS, ACCORDING TO MANUFACTURER'S WRITTEN WSTRUCTIONS, TO FlLL
CRACKS, HOLES, �EPRESSIONS, AND PROTRl1SIONS IN SUBSTRATES FlLL OR LEVEL CRACKS,
HOLES AND DEPRESSIONS 1/B INCH (3 MM) WIDE OR WIDERAND PROTRUSIONS MORE THAN 1132
INCH (08 MM) UNLESS MORE STRINGENT REQUIREMENTS ARE REpUIRED BV MANl1FACTURER'S
WRITTEN INSTRUCTIONS.
B. REMOVE COATINGS, INCLUDING CURING COMPOUNDS, AN� OTHER SUBSTANCES THAT ARE
INCOMPATIBLE W ITH A�HESNES ANO THAT CONTAIN SOAP, WAX, OIL, OR SILICONE, W ITHOUT USING
SOLVENTS. USE MECHANICAL METHODS RECOMMEN�ED IN WRITING BV CARPET TILE
MANUFACTURER.
G CLEAN METAL SUBSTRATES OF GREASE, OIL, SOIL AND RUST, AND PRIME IF DIRECTEO BV ADHESNE
MANl1FACTURER. ROl1GH SAND PAINTED METAL SURFACESAND REMOVE LOOSE PAINT. SAND
ALUMINUM SURFACES, TO REMOVE METAL OXIDES, IMMEDIATELV BEFORE APPLVMG ADHESNE.
BROOM AND VACUUM CLEAN SUBSTRATES TO BE COVERED IMMEDIATELYBEFORE INSTALLING
CARPET TI�E.
3.3 INSTALLATION
A. GENERAL COMPLV WITH CRI106, SECTION 14. "CARPET MODULES,"AND WITH CARPETTILE
MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS.
B. INSTALLATION METHOD'. AS RECOMMENDED IN WRITING 8V CARPET TILE MANUFACTURER.
C. MAWTAIN DVE LOT MTEGRITV. DO NOT MIX �VE LOTS M SAME AREA.
D. WT AND FIT CARPET TILE TO BUTT TIGHTLV TO VERTICAL SURFACES, PERMANENT FI%TURES, AND
BUILT-IN FURNITURE WCW DING CABMETS. PIPES, OUTLET$ EDGINGS, THRESHOLDS, AND
NOSINGS. BIND OR SFAL CUT EDGES AS RECOMMENDED BV CARPET TILE MANUFACTURER. EXTEN�
CARPET TILE INTO TOE SPACES, DOOR REVEALS, CLOSETS, OPEN-BOTTOMED OBSTRUCTIONS,
REMOVABLE FLANGES, ALCOVES. AND SIMILAR OPENINGS.
E. MAWTAIN REFERENCE MARKERS, HOLES. AND OPENINGS THAT ARE IN PLACE OR MARKED FOR
FUTURE CUTTING ev REPEATING ON RNISH FLOORING AS MARKED ON SUBFLOOR. USE
NONPERMANENT, NONSTAINING MARKING DEVICE INSTALL PATTERN PARALLELTO WALLSAND
BORDERS. STAGGER JOINTS OF CARPET TILES 50 CARPETTILE GRID IS OFFSET FROM ACCESS
FLOORWG PANEL GRIo. 00 NOT RLL SEAMS OF ACCESS FLOORWG PANELS wITH CARPET
ADHESNE',KEEPSEAMSFREEOFADHESNE.
3.4 CLEANING AND PROTECTION
A. PERFORM THE FOLLOW MG OPERATIONS IMME�IATELV AFTER INSTALLING CARPET TILE:
7. REMOVE EXCESS ADHESIVE, SEAM SEALER, AND OTHER SURFACE BLEMISHES USING CLEANER
RECOMMENDE� BV CARPET TILE MANUFACTl1RER.
2. REMOVE VARNS THAT PROTRUDE FROM CARPET TILE SURFACE.
3. VACUUM CARPETTILE USING COMMERCIAL MACHME WITH FACEBEATER ELEMENT.
B. PROTECT MSTALLEO CARPET TILE TO COMPLV W ITH CRI 104, SECTION i 6, "PROT WTING INDOOR
INSTALLATIONS." PROTECT CARPET TILE AGAINST DAMAGE FROM CONSTRUCTION OPERATIONS
AND PLACEMENT OF EQUIPMENT AND RXTURES DURING THE REMAIN�ER OF CONSTRUCTION
PERIOD. USE PROTECTION METHODS INDICATED OR RECOMMENDE� IN WRITING BV CARPET TILE
MANUFACTURER.
RELEA5E0 FOR CONSTRUCTION
Suhjec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel ` �
�un��V l�rcNal�=L.
�
DATE: OH�Z5 2O
SECTION 097200 - WALL COVERINGS
PART1-GENERAL
1.iRELATEDDOCUMENTS
A. DRAW INGS AND GENER4L PROVISIONS OF THE CONTR4CT, INC W DING GENERAL AND
SUPPLEMENTARY CONDITIONS AND DIVISION 01 SPEqRCATION SECTIONS, APPLV TO THIS SECTION.
1.25UMMARV
A. SECTION INCLUDES:
1. VINVL WALL COVERING.
2 TEXTILE WALL COVERING.
3. HEAVV-DUTV, SVNTHETIQ TEXTILE WALL COVERING.
1.3 ACTION SUBMITTALS
A. PRODUCT DATA: FOR EACH TVPE OF PRODUCT. INCWDE DATA ON PHVSICAL CHARACTERISTICS,
DURABILITV, FADE RESISTANCE, AND FIRE-TEST-RESPONSE CHARACTERISTICS.
B. SHOP DRAWINGS: SHOW LOCATION AND EXTENT OF EACH WALL-COVERING TVPE INDICATE SEAMS
AND TERMINATION POINTS. SAMPLES: FOR EACH TYPE OF WALL COVERING AND FOR EACH COLOR,
PATTERN, TEXTURE, AN� FINISH SPECIFIE0. Fl1LL WIDTH BV 36-INCH- (914-MM-) LONG IN SRE.
SAMPLES FOR VERIFlCATION: FOR EACH TYPE OF WALL COVERWG AND FOR EACH COLOR,
PATTERN, TEXTURE, AND FlNISH SPEQREq FULL WIDTH BY 36-INCH- (914-MM-) LONG IN SRE.
1 4 FIELD CONDITIONS
A ENVIRONMENTAL LIMITATIONS: DO NOT DELNER OR INSTALL WALL COVERINGS UNTIL SPACES ARE
ENCLOSED AND WEATHERTIGHT, WET WORK IN SPACES IS COMPLETEAN� ORV, WORKABOVE
CEILINGS IS COMPLETE, AND TEMPORARV HVAC SVSTEM IS OPERATING AND MAINTAINING AM8IENT
TEMPERATURE AND HUMIDITV CONDITIONS AT LEVELS INTENDED FOR OCCUPANTS AFTER PROJEC7
COMPLETION DURING THE REMAINDER OF THE CONSTRUCTION PERI00..
B. LIGHTING: DO NOT INSTALL WALLCOVERWG UNTIL LIGHTING THAT MATCHES CONDITIONS INTENDED
FOR OCCUPANTS AFTER PROJECT COMPLETION IS PROVIDED ON THE SURFACES TO RECEIVE WALL
COVERING. VENTILATION'. PROVIDE CONTINUOUS VENTILATION OURING INSTALLATION AN� FOR NOl
LESS THAN THE TIME RECOMMENDED BV WALL-COVERING MANUFACTURER FOR FULL DRVING OR
CURING.
PART2-PRODUCTS
21PERFORMANCEREQUIREMENTS
A RRETEST-RESPONSE CHARACTERISTICS: AS DETERMMED BY TESTING IDENTICAL WALL COVERINGS
APPLIED W ITH IDENTICAL ADHESIVES TO SUBSTRATES ACCORDING TO TEST METHOD INDICATE�
BELOW eV A(lUALIFIE� TESTING AGENCV. IDENTIFV PRO�UCTS W ITH APPROPRIATE MARKW GS OF
APPLICABLE TESTING AGENCV.
1. SURFACEBURNING CHARACTERISTICS: COMPLV WITH ASTM E 84; TESTING BY A QUALIFlED
TESTING AGENCV. IDENTIFV PRODUCTS W ITH APPROPRIATE MARKINGS OF APPLICABLE TESTME
AGENCV.
A. FLAME-SPREAD INDEX:25 OR LE55.
B. SMOKE-DEVELOPED INDE%:4500R LESS.
22 ACCESSORIES
A. ADHESNE: MILDEW-RESISTANT, NONSTAINING ADHESNE, FOR USE WITH SPEQFIC WALL COVERING
AND SUBSTRATE APPLICATION INDICATED AND AS RECOMMENDED IN W RITMG BV WALL-COVERING
MANUFACTURER.
B. PRIMER/SEALER: MILDEW RESISTANT, COMPLVING WITH REpUIREMENTS RECOMMENDED IN WRITING
BV PRIMER/SEALER AND WALL-COVERING MANUFACTURERS FOR INTENDED SUBSTRATE. METAL
PRIMER: INTERIOR FERROUS METAL PRIMER COMPLVING W ITH AND RECOMMENDED IN W RITING BV
PRIMERANO WALL-COVERING MANUFACTURERS FOR INTENOED SUBSTRATE. SEAM TAPE: AS
RECOMMENDED IN WRITING BV WALL-COVERING MANUFACTURER.
PART 3 - EXEGUTION
3.1 EXAMINATION
A. EXAMINE SUBSTRATES AND CONDITIONS, W ITH INSTALLER PRESENT, FOR COMPLIANCE W ITH
REQUIREMENTS FOR LEVEWESS, WALL PLUMBNESS, MAXIMUM MOISTURE COMENT, AND OTHER
CONDITIONS AFFECTING PERPoRMANCE OF THE WORK. PROCEED W ITH INSTALLATION ONLY AFTER
UNSATISFACTORV CONDITIONS HAVE BEEN CORRECTED.
32 PREPARATION
A. COMPLY W ITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR SURFACE PREPARATION. CLEAN
SUBSTRATES OF St1BSTANCES THAT COULO IMPAIR BOND OF WALL COVERING, INCWDING �IRT,
OIL, GREASE, MOLD, MILDEW, AN� INCOMPATIBLE PRIMERS. PREPARE SUBSTRATES TO ACHIEVE A
SMOOTH, DRV, CLEAN, STRUCTURALLV SOUND SURFACE FREE OF FLAKING, UNSOUND COATINGS,
CRACKS,AND DEFECTS.
1. MOISTURE CONTENT: MAXIMUM OF 5 PERCENT ON NEW PL4STER, CONCRETE, AND CONCRETE
MASONRV UNITS W HEN TESTED W ITH AN ELECTRONIC MOISTURE METER.
2. PLASTER: ALLOW NEW PLASTER TO CURE. NEUTRALIZE AREAS OF HIGH ALKALINITV. PRIME WITH
PRIMER RECOMMENDED IN WRITING BY PRIMERISEALER MANUFACTURERAND WALL-COVERING
MANUFACTURER.
3. METALS: IF NOT FACTORV PRIMED, CLEAN AND APPLV PRIMER RECOMMENDED IN W RITING BV
PRIMERISEALER MANUFACTURER AND WALL-COVERMG MANUFACTURER.
4. GVPSUM BOAR�: PRIME WITH PRIMERAS RECOMMENOED IN WRITING BV PRIMER/SEALER
MANUFACTURER AND WALL-COVERING MANUFACTURER.
5. PAINTED SURFACES: TREAT AREAS SUSCEPTIBLE TO PIGMENT BLEED WG.
B. CHECK PAINTED SURFACES FOR PIGMENT BLEEOING. SAND GLOSS, SEMIGLOSS, AND EGGSHELL
FINISH WITH FINE SANDPAPER. REMOVE HARDWAREAND HARDWARE ACCESSORIES, ELECTRICAL
PL4TES AND COVERS, LIGHT FlXTURE TRIMS, AND SIMILAR ITEMS. ACCLIMATRE WALL-COVERMG
MATERIALS BV REMOVING THEM FROM PACKAGING W THE INSTALLATION AREAS NOT LESS THAN 24
HOURS BEFORE INSTALLATION.
3.3 WALL-COVERING INSTALLATION
A. COMPLV WITH WALL-COVERING MANUFACTURERS' WRITTEN INSTALLATION INSTRl1CTIONS
APPLICABLE TO PRODUCTS AND APPLICATIONS INDICATED. CUT WALLCOVERING STRIPS IN ROLL
NUMBER SEQUENCE CHANGE THE ROLL NUMBERS AT PARTITION BREAKS AND CORNERS.
B. INSTALL WALL COVERING W ITHOUT LIFTEO OR CURLING EDGES AND W ITHOUT VISIBLE SHRINKAGE.
INSTALL SEAMS VERTICAL AND PLUMB AT LEAST 61NCHE5 (150 MM) FROM OUTSIDE CORNERS AND
[31NCHE5 (]5 MM)7 [61NCHE5 (150 MM)] FROM INSIDE CORNERS UNLESS A CHANGE OF PATTERN OR
COLOR EXISTS AT CORNER. HORIZONTAL SEAMS ARE NOT PERMITTED.
G TRIM EDGES AND SEAMS FOR COLOR UNIFORMITV, PATTERN MATCH, AND TIGHT CLOSURE. BUTT
SEAMS WITHOUT OVERLAPS OR GAPS BETW EEN STRIPS. FULLV BOND WALL COVERING TO
SUBSTRATE. REMOVE AIR BUBBLES, WRINKLES, BLISTERS, AN� OTHER DEFECTS.
3A CLEANMG
A. REMOVE EXCESS ADHESIVE AT SEAMS, PERIMETER E�GES, AND ADJACENT SURFACES. USE
CLEANING METHODS RECOMMENDED IN WRITING BV WALLCOVERING MANUFACTURER. REPLACE
STRIPS THAT CANNOT BE CLEANED. REINSTALL HARDWARE AND HARDWARE ACCESSORIES,
ELECTRICAL PLATES AND COVERS, LIGHT FlXTURE TRIMS, AND SIMILAR ITEMS.
SECTION 099123 - INTERIOR PAINTING
PART1-GENERAL
1.1RELATEDDOCUMENTS
A. DRAW MGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND
SUPPLEMENTARV CONDITIONS AND DNISION 01 SPECIFICATION SECTIONS, APPLV TO THIS SECTION.
12SUMMARV
A. SECTION INCWDES SURFACE PREPARATION AND THE APPLICATION OF PAINT SYSTEMS ON THE
FOLLOWING INTERIOR SUBSTRATES:
1.CONCRETE.
2. CLAY MASONRV.
3- CONCRETE MASONRV UNITS (CMU)-
4. STEEL.
S CAST IRON.
6.GALVANIZED METAL.
7. WOOD.
8. GYPSUM BOARD.
9.PLASTER.
1.3 ACTION SUBMITTALS
A. PRODUCT DATA'. FOR EACH TVPE OF PRODUCT. INCW DE PREPARATION REOUIREMENTS AND
APPLICATION INSTRUCTIONS.
B. SAMPLES FOR VERIFlCATION: FOR EACH TVPE OF PAINT SVSTEM AND M EACH COLOR AND GLOSS OF
TOPCOAT.
1. SUBMIT SAMPLES ON RIGIO BACKING, 8 INCHES (200 MM) SQl1ARE.
2. STEP COATS ON SAMPLES TO SHOW EACH COAT RE�UIRED FOR SVSTEM.
3. LABEL EACH COAT OF EACH SAMPLE.
4. LABEL FACH SAMPLE FOR LOCATION AND APPLICATION AREA.
C. PRODUCT LIST: FOR EACH PRODUCT INDICATED, INCLUDE THE FOLLOW ING:
1. CROSS-REFERENCE TO PAINT SVSTEM AND LOCATIONS OF APPLICATION AREAS. USE SAME
DESIGNATIONS INDICATED ON DRAW INGS AN� IN SCHEDULES.
2. PRINTOUT OF CURRENT "MPI APPROVED PRODUCTS LIST" FOR EACH PRODUCT CATEGORV
SPEQRED IN PART 2, W ITH THE PROPOSE� PRO�UCT HIGHLIGHTED.
3. VOC CONTENT.
1 4 DELIVERY. STORAGE, AND HANDLING
A. STORE MATERIALS NOT IN USE IN TIGHTLY COVERED CONTAWERS IN W ELL-VENTILATED AREAS W ITH
AMBIENT TEMPERATURES CONTINUOUSLV MAINTAINED AT NOT LESS THAN 45 DEG F(] DEG C).
MAINTAIN CONTAWERS IN CLEAN CONDITION, FREE OF FOREIGN MATERIALS AND RESIDUE. REMOVE
RAGS AND WASTE FROM STORAGE AREAS DAILV.
1.5 FIELD CONDITIONS
A. APPLV PAINTS ONLV W HEN TEMPERATURE OF SURFACES TO BE PAINTED AND AMBIENT AIR
TEMPERATURES ARE BETWEEN 50 AND 95 OEG F(10 AND 35 DEG C). DO NOT APPLV PAINTS WHEN
RELATNE HUMIDITY EXCEEDS 85 PERCENT; AT TEMPERATURES LESS THAN 5 DEG F(3 DEG C)
ABOVE THE DEW POINT; OR TO DAMP OR WET SURFACES.
PART2�PRODUGTS
21 PAMT, GENERAL
A. MPI STANDARDS: PROVIDE PRODUCTS THAT COMPLV W ITH MPI STANOAROS INOICATED AND THAT
ARE LISTED IN ITS "MPI APPROVED PRODUCTS LIST."
B. MATERIAL COMPATIBILITV:
1. PROVI�E MATERIALS FOR USE W ITHM EACH PAINT SYSTEM THAT ARE COMPATIBLE WITH ONE
ANOTHER AND SUBSTRATES INDICATED, UNDER CONDITIONS OF SERVICE AND APPLICATION AS
DEMONSTRATED BV MANUFACTURER, BASED ON TESTING AND FlELD EXPERIENCE.
2. FOR EACH COAT IN A PAINT SVSTEM, PROVIDE PRODUCTS RECOMMENDED IN WRITING BV
MANUFACTURERS OF TOPCOAT FOR USE IN PAINT SYSTEM AND ON SUBSTRATE INDICATED.
2 2 PAINT - W D DOORS
A. SEMI-GLOSS FINISH:
1. iST COAT'. BENJAMIN MOORE FRESH START HIGH-HIDING ALL PURPOSE PRIMER 04fi (44 G/L�, MPI
# 6, 1], %-GREEN 1], 39, 50, X-GREEN SQ 13], %-GREEN 13I, LEED CREDIT, CHPS CERTIFIED.
2. 2ND COAT CORONADO RUST SCAT WATERBORNE ACRVLIC SEMI-GLOSS 90 (134 GIL), MPI # 153.
3. 3RD COAT: CORONADO RUST SCAT WATERBORNE ACRYLIC SEMI-GLO55 90 (134 G/L�, MPI # 153,
PART 3 - EXECIITION
3.1 EXAMINATION
A EXAMME SUBSTRATES AN� CONDITIONS, W ITH APPLICATOR PRESENT, FOR COMPLIANCE W ITH
REQUIREMENTS FOR MAXIMUM MOISTURE CONTENT AN� OTHER CONDITIONS AFFECTING
PERFORMANCE OF THE WORK.
B. MAXIMUM MOISTURE CONTENTOF SUBSTRATES: WHEN MEASURED WITH AN ELECTftONIC MOISTURE
METER AS FOLLOWS:
1. CONCRETE: 12 PERCENT.
2. MASONRY (CLAV AND CMU): 12 PERCENT.
3. WOOD: 15 PERCENT.
4. GVPSUM BOARD: 12 PERCENT.
S PLASTER'.12PERCENT.
G GVPSUM BOARD SUBSTRATES: VERIFV THAT FINISHING COMPOUND IS SANDED SMOOTH.
D. PLASTER SUBSTRATES: VERIFV THAT PLASTER IS FULLV CURED.
E SPRAV-TEXTURED CEILING SUBSTRATES'. VERIFV THAT SURFACES ARE DRV.
F.VERIFV SUITABILITV OF SUBSTRATES, WCLUDING SURFACE CON�ITIONS AND COMPATIBILITV WITH
EXISTING FINISHES AND PRIMERS.
G. PROCEED W ITH COATING APPLICATION ONLV AFTER UNSATISFACTORY CONDITIONS HAVE BEEN
CORRECTED.
1. APPLICATION OF COATING IN�ICATES ACCEPTANCE OF SURFACES AND CONDITIONS.
3.2 PREPARATION
A. COMPLV WITH MANUFACTURER'S WRITTEN WSTRUCTIONS AND RECOMMENDATIONS IN "MPI MANUAL'
APPLICABLE TO SUBSTRATES INOICATEO.
B. REMOVE HAR�WAR6 COVERS, PLATES, AN� SIMILAR ITEMS ALREA�V IN PLACE THATARE
REMOVABLE AND ARE NOT TO BE PAWTED. IF REMOVAL IS IMPR4CTICAL OR IMPOSSBLE BECAUSE
OF 5¢E OR W EIGHT OF ITEM. PROV IDE SURFACE-APPLIED PROTECTION BEFORE SURFACE
PREPARATION AND PAINTING. CLEAN SUBSTRATES OF SUBSTANCES THAT COULD IMPAIR BOND OF
PAINTS, INCLUDING DUST, DIRT, OIL, GREASE, AND INCOMPATBLE PAINTS AND ENCAPSULANTS.
G CONCRETESUBSTRATES:REMOVERELEASEAGENTS.CURINGCOMPOUNDS,EFFLORESCENCE,AND
CHALK. DO NOT PAINT SURFACES IF MOISTURE CONTENT OR ALKALINITY OF SURFACES TO BE
PAINTEO EXCEEDS THAT PERMITTED IN MANUFACTURER'S WRITTEN INSTRUCTIONS. MASONRV
SUBSTRATES: REMOVE EFRORESCENCE AND CHALK. DO NOT PAINT SURFACES IF MOISTURE
CONTENT OR ALKALINITV OF SURFACES OR MORTAR JOINTS EXCEED THAT PERMITTED IN
MANUFACTURER'S WRITTEN INSTRUCTIONS.
D. SHOP-PRIMED STEEL Sl1BSTRATES: CLEAN FIELD WEL�S, BOLTED CONNECTIONS, AND ABRADED
AREAS OF SHOP PAINT, AND PAINT EXPOSED AREAS W ITH THE SAME MATERIAL AS USED FOR SHOP
PRIMING TO COMPLV W ITH SSPC-PA 1 FOR TOUCHING UP SHOP-PRIMED SURFACES. GALVANIZED-
METAL SUBSTRATES: REMOVE GREASE AND OIL RESIDUE FROM GALVANRED SHEET METAL
FABRICATED FROM COIL STOCK BV MECHANICAL METHODS TO PRODUCE CLEAN, LIGHTLV ETCHED
Sl1RFACES THAT PROMOTE A�HESION OF S1165EOUENTLYAPPLIED PAINTS.
3.3 APPLICATION
A. APPLY PAINTS ACCOR�ING TO MANUFACTURER'S WRITTEN WSTRUCTIONS AND TO
RECOMMENDATIONS IN "MPI MANUAL"
B. TINT EACH UNDERCOAT A LIGHTER SHADE TO FACILITATE IDENTIFICATION OF EACH COAT IF
MULTIPLE COATS OF SAME MATERIAL ARE TO BE APPLIED. TINT UNDERCOATS TO MATCH COLOR OF
TOPCOAT, BUT PROVIOE SUFFICIENT DIFFERENCE M SHADE OF UNOERCOATS TO �ISTINGUISH
EACH SEPARATE COAT.
C. IF UNDERCOATS OR OTHER CONDITIONS SHOW THROUGH TOPCOAT, APPLV ADDITIONAL COATS
UNTIL CURED FlLM HAS A 11NIFORM PAINT FINISH, COLOR, AND APPEARANCE.
�. APPLV PAINTS TO PRODUCE SURFACE FlLMS WITHOUT CLOUDWESS, SPOTTING, HOLIDAVS, LAPS,
BRUSH MARKS, ROLLER TRACKING, RUNS, SAGS, ROPMESS, OR OTHER SURFACE IMPERFECTIONS.
CUT IN SHARP LINES AND COLOR BREAKS.
E. PAINTING FIRE SUPPRESSION, PLUMBING, HVAC. ELECTRICAL COMMUNICATION, AND ELECTRONIC
SAFETY AND SECURITV WORK:
1. PAINTTHE FOLLOWING WORK WHERE EXPOSED IN EQUIPMENT ROOMS'.
A. EQUIPMENT, INCLUDING PANELBOARDS AND SWITCH GEAR.
B. UNINSULATE� METAL PIPING.
C. UNINSl1LATE0 PL4STIC PIPING.
D. PIPE HANGERS AND SUPPORTS.
E METAL CON�UIT.
F. PLASTIC CONDUIT.
G. TANKS THAT �O NOT HAVE FACTORV-APPLIED FINAL FINISHES.
H. DUCT, EQUIPMENT, AND PIPE INSULATION HAVING COTTON OR CANVAS INSULATION
COVERING OR OTHER PAINTABLE JACKET MATERIAL.
2. PAINT THE FOLLOW WG WORK WHERE EXPOSED IN OCWPIED SPACES:
A. EpUIPMENT, INCLUDING PANELBOAR�S.
B. UNINSl1LATED METAL PIPING.
C. UNINSULATE� PLASTIC PIPWG.
D. PIPE HANGERS AND SUPPORTS.
E.METALCONOWT.
F. PLASTIC CONOUIT.
G. DUCT, EQUIPMENT, AND PIPE INSULATION HAVING COTTON OR CANVAS INSULATION
COVERING OR OTHER PAINTABLE JACKET MATERIAL.
H. OTHER ITEMS AS DIRECTE� BV ARCHITECT.
3. PAINT PORTIONS OF INTERNAL SURFACES OF METAL DUCTS, WITHOUT LMER, BEHIN� AIR INLETS
AND OUTLETS THATARE VISBLE FROM OCCUPIED SPACES.
34 FIELD QUALITV CONTROL
A. DRV FlLM THICKNESS TESTING�. OW NER MAV ENGAGE THE SERVICES OF A QUALIFlED TESTING AND
WSPECTING AGENCV TO INSPECT AND TEST PAINT FOR DRV FlLM THICKNESS.
1. CONTRACTOR SHALL TOUCH UP AND RESTORE PAINTED SURFACES DAMAGED BV TESTING.
2. IF TEST RESULTS SHOW THAT DRY RLM THICKNESS OF APPLIED PAINT DOES NOT COMPLV WITH
PAMT MANl1FACTURER'S WRITTEN RECOMMENDATIONS, CONTR4CTOR SHALL PAV FOR
TESTING AND APPLV ADDITIONAL COATS AS NEEDED TO PROVIDE DRV FILM THICKNESS THAT
COMPLIES W ITH PAINT MANUFACTURER'S WRITTEN RECOMMENDATIONS.
3.5 CLEANING AN� PROTECTION
A. AT END OF EACH WORKDAY, REMOVE RUBBISH, EMPTY CANS. RAGS, AND OTHER DISCARDED
MATERIALS FROM PROJECT SITE.
B. AFTER COMPLETING PAINT APPLICATION, CLEAN SPATTERED SURFACES. REMOVE SPATTERED
PAINTS BV WASHING, SCRAPING, OR OTHER METHODS. DO NOT SCRATCH OR DAMAGE ADJACENT
FlNISHED SURFACES.
C. PROTECT WORK OF OTHER TRADES AGAINST DAMAGE FROM PAINT APPLICATION. CORRECT DAMAGE
TO WORK OF OTHER TRADES BV CLEANING, REPAIRWG, REPLACING, AND REFINISHWG, AS
APPROVED BV ARCHITECT, AND LEAVE IN AN UNDAMAGED CONDITION.
D. AT COMPLETION OF CONSTRUCTION ACTIVITIES OF OTHER TRADES, TOUCH UP AND RESTORE
DAMAGED OR DEFACED PAINTED SURFACES.PART 1- GENERAL
SECTION123640-STONE COUNTERTOPS
PART1-GENERAL
1.1RELATEDDOCUMENTS
A. DRAW INGS AND GENERAL PROVISIONS OF THE CONTRACT, MCLUDING GENERAL AND
SUPPLEMENTARV CONDITIONS ANO OIVISION 01 SPEQFICATION SECTIONS, APPLV TO THIS SECTION.
125UMMARV
A. SECTION INCLUDES STONE COUNTERTOPS.
1.3 ACTION SUBMITTALS
A. PRODUCT DATA: FOR EACH VARIETV OF STONE, STONE ACCESSORV, AND MANUFACTURED
PRODUCT.
B. SHOP DRAWINGS: INCWDE PLANS, SECTIONS, DETAILS, ANO ATTACHMENTS TO OTHER WORK. SHOW
LOCATIONS AND DETAILS OF JOINTS. SHOW DIRECTION OF VEINING, GRAIN, OR OTHER DIRECTIONAL
PATTERN.
G SAMPLES FOR VERIFICATION: FOR EACH STONE TVPE INDICATED, IN SETS OF SAMPLES NOT LESS
THAN 121NCHE5 (300 MM) SQUARE. INC W �E THREE OR MORE SAMPLES IN EACH SET AND SHOW
THE FULL RANGE OF VARIATIONS IN APPEARANCE CHARACTERISTICS EXPECTED IN COMPLETED
WORK.
1 4 QUALITV ASSURANCE
A FABRICATOR QUALIRCATIONS: SHOP THAT EMPLOVS SKILLED WORKERS WHO CUSTOM-FABRICATE
STONE COUNTERTOPS SIMILAR TO THAT REQUIRE� FOR THIS PROJECT, AND WHOSE PROOUCTS
HAVE A RECOR� OF SUCCESSFUL IN-SERVICE PERFORMANCE. INSTALLER QUALIFICATIONS:
FABRICATOR OF STONE COUNTERTOPS.
1.5 DELNERY, STORAGE, AND HANDLING
A. STORE AN� HANDLE STONE AND RELATED MATERIALS TO PREVENT DETERIORATION OR DAMAGE
DUE TO MOISTURE, TEMPERATURE CHANGES, CONTAMINANTS, CORROSION, BREAKING, CHIPPING,
AND OTHER CAUSES.
1B FIELD CONDITIONS
A FlELD MEASUREMENTS: VEPoFV DIMENSIONS OF CONSTRUCTION TO RECEIVE STONE COUNTERTOPS
BV FIEL� MEASUREMENTS BEFORE FABRICATION AND IN�ICATE MEASUREMENTS ON SHOP
DRAW WGS.
PART2-PRODUGTS
21 GRANITE
A. MATERIAL STANDARD: AS INDICATED ON DRAWINGS. COMPLV W ITH ASTM C 615.
2.2 MARBLE
A. MATERIAL STANOARO: COMPLV WITH ASTM C 503. AS INDICATED ON ORAWINGS.
2.3 OTHER STONE
A. MATERIAL STANDARDS: AS INDICATED ON DRAWINGS.
1. MAXIMUM ABSORPTION PER ASTM C 9]/C 9]
2. MINIMUM COMPRESSNE STRENGTH PER ASTM C 170IC 1]OM
3. MINIMUM REXURAL STRENGTH PER ASTM C 880/C 880:
4. MINIMUM STONE ABRASION RESISTANCE PER ASTM C 241/C 241M OR ASTM C 1353: [10]
2 4 ADHESNES, GROUT, SEALANTS, AND STONE ACCESSORIES
A. GENERAL: USE ONLV ADHESNES FORMULATE� FOR STONE AND CERAMIC TILE AND THATARE
RECOMMENDEO BV THEIR MANUFACTURER FOR THE APPLICATION INDICATED. WATER-0LEANABLE
EPO%V GROUL ANSI A118.3, CHEMICAL-RESISTANT, WATER-CLEANABLE, TILE-SETTMG AND-
GROUTING EPDXV. STONE CLEANER: SPECIFlCALLV FORMULATED FOR STONE TVPE$ RNISHES,
AND APPLICATIONS INDICATED, AS RECOMMENDEO BV STONE PRODUCER. DO NOT USE CLEANING
COMPOUNDS CONTAINING AqDS, CAUSTICS, HARSH FILLERS, OR ABRASNES. STONE SEALER:
COLORLESS, STAIN-RESISTANT SEALER THAT DOES NOT AFFECT COLOR OR PHVSICAL PROPERTIES
OF STONE SURFACES, AS RECOMMENDEO BV STONE PRODUCER FOR APPLICATION INDICATED.
25 STONE FABRICATION, GENERAL
A. SELECT STONE FOR INTENDED USE TO PREVENT FABRICATED UNITS FROM CONTAINING CRACKS,
SEAMS, AND STARTS THAT COULD IMPAIR STRUCTURAL INTEGRITV OR FUNCTION. GRADE AND
MARK STONE FOR FINAL LOCATIONS TO PRODUCE ASSEMBLED COUNTERTOP UNITS WITH AN
OVERALLUMFORM APPEARANCE.
B. FABRICATE STONE COUNTERTOPS IN SIZES ANO SHAPES REQUIREO TO COMPLV W ITH
REQUIREMENTS INDICATED. FOR GRANITE. COMPLV WITH RECOMMENDATIONS IN NBGQA'S
"SPECIRCATIONS FOR ARCHITECTURAL GRANITE"FOR MARBLE, COMPLV W ITH RECOMMENDATIONS
IN MIA'S "DIMENSION STONE - DESIGN MANUAL VU' CAREFULLV INSPECT FINISHED STONE UNITS AT
FABRICATION PLANT FOR COMPLIANCE WITH REpUIREMENTS FOR APPEARANCE, MATERIAL, AN�
FABRICATION. REPLACE DEFECTNE UNITS.
2.65TONECOUNTERTOPS
A. GENERAL COMPLV WITH RECOMMENDATIONS IN MIA'S "DIMENSION STONE - DESIGN MANUAL VI."
B. NOMINAL THICKNESS: PROVIDE THICKNESS INDICATED ON DRAWINGS.OPTIONS IN "EDGE �ETAIL"
PARAGRAPH BELOW ARE EXAMPLES ONLV. SEE MIA'S "�IMENSION STONE-DESIGN MANUAL Vll
EDGE DETAIL AS INDICATED ON DRAWINGS, SPLASHES: AS INDICATED ON DRAWINGS. JOINTS:
FABRICATE COUNTERTOPS W ITHOUT JOINTS.
PART 3 - EXECUTION
3.1 EXAMINATION
A EXAMWE SUBSTRATES TO RECENE STONE COUNTERTOPSAND CONDITIONS UNDER WHICH STONE
COUNTERTOPS WILL BE INSTALLED, WITH INSTALLER PRESENT, FOR COMPLIANCE W ITH
REQUIREMENTS FOR INSTALLATION TOLERANCES AND OTHER CONDITIONS AFFECTING
PERFORMANCE OF STONE COUMERTOPS. PROCEED W ITH INSTALLATION ONLY AFTER
UNSATISFACTORV CONDITIONS HAVE BEEN CORRECTED.
3 2 PREPARATION
A. ADVISE INSTALLERS OF OTHER WORK ABOUT SPECIRC RWUIREMENTS FOR PLACEMENT OF
INSERTS AND SIMILAR ITEMS TO BE 115ED BV STONE COUNTERTOP INSTALLER FOR ANCHORING
STONE COUNTERTOPS. FURNISH INSTALLERS OF OTHER WORK W ITH DRAWINGS OR TEMPLATES
SHOWMG LOCATIONS OFTHESE ITEMS. BEFORE INSTALLWG STONE COUNTERTOP$ QEAN DIRTV
OR STAINED STONE SURFACES BV REMOVING SOIL, STAINS, AND FOREIGN MATERIALS. CLEAN
STONE BV THOROUGHLV SCRUBBING W ITH FIBER BRUSHES AND THEN DRENCHING W ITH CLEAR
WATER. USE ONLV MILD CLEANING COMPOUNDS THAT CONTAIN NO CAUSTIC OR HARSH MATERIALS
ORABRASIVES. ALLOW STONE TO DRV BEFORE INSTALLING.
3.3 CONSTRUCTION TOLERANCES
A. VARIATION FROM LEVEL: �O NOT EXCEED 1/S INCH IN 96 MCHES (3 MM IN 240� MM), 1I41NCH (6 MM)
MAXIMUM. VARIATION IN JOINT W IDTH: 00 NOT VARV JOINT THICKNE55 MORE THAN ONE-FOURTH
OF NOMINAL JOINT W IDTH. VARIATION IN PLANE AT JOINTS (LIPPING): DO NOT EXCEED i164-INCH (OA-
MM) DIFFERENCE BETW EEN PLANES OF ADJACENT UNITS. VARIATION M LME OF EDGE AT JOINTS
(LIPPING): DO NOT EXCEED iB4-MCH (�.4-MM) OIFFERENCE BETW EEN E�GES OF ADJACENT UNITS,
WHERE EDGE LINE CONTINUES ACROSS JOINT.
3.4 INSTALLATION OF COUMERTOPS
A. GENERAL: INSTALL COUNTERTOPS OVER PLVWOOD SUBTOPS W ITH FULL SPREAD OF WATER-
CLEANABLE EPDXV ADHESIVE.
B. SET STONE TO COMPLY WITH RE�UIREMENTS INDICATED. SHIM AND ADJUST STONE TO LOCATIONS
INDICATED, WITH UNIFORM JOINTS OF WIDTHS INDICATEDAND WITH EDGES AND FACES ALIGNED
ACCORDING TO ESTABLISHED RELATIONSHIPS AND INDICATED TOLERANCES. INSTALL ANCHORS
AND OTHER ATTACHMENTS INDICATED OR NECESSARY TO SECURE STONE COUNTERTOPS IN
PLACE.
C. BOND JOINTS W ITH STONE ADHESIVE AND �RAW TIGHT AS COUNTERTOPS ARE SET. MASK AREAS OF
COUNTERTOPSADJACENTTOJOINTSTOPREVENTADHESIVESMEARS.INSTALLBACKSPLASHES
AND ENO SPLASHES BV ADHERING TO WALL W ITH W ATER-0LEANABLE EPDXV AOHESIVE AND TO
COUNTERTOPS W ITH STONE ADHESIVE. MASK AREAS OF COUNTERTOPS AND SPLASHES A�JACENT
TO JOINTS TO PREVENT ADHESIVE SMEARS.
3.5 ADJUSTING AND CLFANING
A. IN-PROGRESS CLEANING CLEAN COUNTERTOPS AS WORK PROGRESSES. REMOVE ADHESNE,
GROUT, MORTAR, AND SEALANT SMEARS IMMEDIATELY. REMOVE AND REPLACE STONE
COUNTERTOPS. REPLACE IN A MANNER THAT RESULTS IN STONE COUNTERTOPS MATCHING
APPROVED SAMPLES AND MOCKUPS, COMPLVING W ITH OTHER RE�UIREMENTS, AND SHOW ING NO
EVIDENCE OF REPLACEMENT.
B. CLEAN STONE COUNTERTOPS NO FEWER THAN SIX DAVS AFTER COMPLETION OF SEALANT
INSTALLATION INSTALLATION, USING CLEAN WATER AND SOFT RAGS. DO NOT USE W IRE BRUSHES,
ACID-TVPE CLEANING AGENTS, QEANING COMPOUNDS WITH CAUSTIC OR HARSH FlLLERS, OR
OTHER MATERIALS OR METHODS THAT COULD DAMAGE STONE. SEALER APPLICATION: APPLY
STONE SEALER TO COMPLV W ITH STONE PRODUCER'S AND SEALER MANUFACTURER'S W RITTEN
INSTRUCTIONS.
SECTION 123661 - SIMULATED STONE COUNTERTOPS
PART1-GENERAL
1.1RELATEDDOCUMENTS
A. DRAW INGS AND GENERAL PROVISIONS OF THE CONTRACT. INCLUDING GENERAL AND
SUPPLEMENTARV CONDITIONS ANO OIVISION 01 SPEQFICATION SECTIONS, APPLV TO THIS SECTION.
12 SUMMARV
A.SECTIONINCLUDES:
1. SOLID-SURFACE-MATERIAL COUNTERTOPS ANO BACKSPLASHES.
1.3 ACTION SUBMITTALS
A. PRODUCT �ATA FOR COUMERTOP MATERIALS
B. SHOP DRAWINGS: FOR COUNTERTOPS. SHOW MATERIALS, FINISHES, EDGE AND BACKSPLASH
PROFlLES. METHODS OF JOINING, AND CUTOUTS FOR PLUMBING FIXTURES.
G SAMPLES FOR INITIAL SELECTION�. FOR EACH TVPE OF MATERIAL EXPOSED TO VIEW.
D. SAMPLES FOR VERIFICATION'. FORTHE FOLLOWING PRODUCTS:
1_ COUNTERTOP MATERIAL, 6 INCHES (160 MM) SQUARE.
2. ONE FULL-SIZE SOLI�-SURFACEMATERIAL COUMERTOP, W ITH FROM EDGE AND BACKSPLASH, 8
BV 101NCHE5 (200 BV 250 MM), OF CONSTRUCTION ANO IN CONFIGURATION SPECIFIED.
1 4 PROJECT CONDITIONS
A FlELD MEASUREMENTS: VERIFY DIMENSIONS OF COUNTERTOPS BY FlELD MEASUREMENTS AFTER
BASE CABINETS ARE INSTALLED Bl1T BEFORE COIINTERTOP FABRICATION IS COMPLETE.
1 S COORDINATION
A. COORDINATE LOCATIONS OF UTILITIES THAT WILL PENETRATE COUNTERTOPS OR BACKSPLASHES.
PART2-PRODUCTS
2.1 SOLID-SURFACE-MATERIAL COUNTERTOPS
A. COUNTERTOPS: SOLID SURFACE MATERIAL.
B. BACKSPLASHES: AS SHOWN ON ORAWINGS.
C. FABRICATION: FABRICATE TOPS IN ONE PIECE WITH SHOP-APPLIED EDGES UNLESS OTHERWISE
INDICATED. COMPLV W ITH SOLID-SURFACEMATERIAL MANUFACTURER'S W RITTEN INSTRUCTIONS
FORADHESIVES, SEALERS, FABRICATION, ANO FINISHING.
22 COUNTERTOP MATERIALS
A. PARTI0.EBOAR�: ANSI A208.1, MA�E W ITH BINDER CONTAINING NO UREA FOFMALDEHVDE PLVWOOD:
EXTERIOR SOFTWOOD PLVWOOD COMPLYING W ITH OOC PS 1, GR4DE GC PWGGEO, TOl1CH
SANDED. ADHESIVES: ADHESNES SHALL NOT CONTAIN UREA FORMALDEHV�E.
B. ADHESIVES: ADHESIVES SHALL COMPLY WITH THE TESTWG AND PRODUCT REQUIREMENTS OF THE
CALIFORNIA DEPARTMENT OF HEALTH SERVICES"'STANDARD PRACTICE FOR THE TESTING OF
VOLATILE ORGANIC EMISSIONS FROM VARIOUS SOURCES USMG SMALL-SCALE ENVIRONMENTAL
CHAMBERS"
G SOLID SURFACE MATERIAL HOMOGENEOUS SOLID SHEETS OF FlLLEO PLASTIC RESIN COMPLVING
W ITH ANSI 551.
PART 3 - EXEGUTION
3.1 INSTALLATION
A. INSTALL COUNTERTOPS LEVEL TO A TOLERANCE OF 1/8 INCH IN 8 FEET (3 MM M 2 4 M} FASTEN
COUNTERTOPS BV SCREWING THROUGH CORNER BLOCKS OF BASE UNITS INTO UNDERSI�E OF
COUNTERTOP. PRE-0RILL HOLES FOR SCREWSAS RECOMMENDEO BV MANUFACTURER. ALIGN
ADJACENT SURFACES AND, USING ADHESIVE IN COLOR TO MATCH COUMERTOP, FORM SEAMS TO
COMPLV WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. CAREFULLV DRESS JOINTS SMOOTH,
REMOVE SURFACE SCRATCHES, AND CLEAN ENTIRE SURFACE. INSTALL BACKSPLASHES AND
ENDSPLASHES TO COMPLY W ITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR ADHESIVES,
SEALERS, FABRICATION, AND FlNISHING.
�
/ ♦ 1
�
INDUSTRIOUS
COWORKING
880 W MONON GREEN BLVD
CARMEL, IN 46032
OWNEPRENANT
INDUSTRIOUS
215PARKAVES,4E1300
NEW YORK, NY 1 W03
ARCXITECT OF HECOPD
NORX
325 N LASALLE Si- SOIiE SCO
CHICAGO. IL 60654
PEiER.DUBWCmNORR-COM
312-0242400
MEP ENGINEER
MEENGINEERS
29 WEST 38iH SiREEi, SiH FLOOR
NEW YORK. NY 10018
CONiACi: BRIAN SHASSIAN
BBIANSHASSIANC�.ME-ENGINEER$_COM
JOHN HIGGINS
JOHN.HIGGWS(�MEENGINEERS.COM
�212J 44]-6]]0 PHONE
LIGHTING DESIGNER
REGENCY
9261 JOkDAN AVE
CHAiSWORiH, CA
800-28d-202J
ISSUE DATES
REV. DAiE DESCRIPiION
06/OS/2020 DD3
06/18l2020 CDvI
0]/06/2020 CDv2
O]/V/2020 100%/PERMIT
SEAL&SIGNATUNE
BY CHECK
BG PJ
BC PJ
eC Po
BC PJ
CARMEL CITY- 880 MONON GREEN
PRQIECT NUMBER
IND680MON
DRAWING TITLE
SPECIFlCATIONS
SCALE
1 1/2" = 1' 0"
SHEET NUMBER
A-907
oF
PROJECTNAME