HomeMy WebLinkAboutE000 Electrical LegendNOTES:
1. ALLEXPOSEDRACEWAVSARETOBEINSTALLEDPARALLELORPERPEN�ICULARTOWALLSORSTRUCTURAL
MEMBERS Sl1CH THAT THEV FOLLOW STRUCTURAL SURFACE CONTOURS AND SHALL BE INSTALLED Sl1CH
THATTHEVDONOTOBSTRUCTPASSAGEWAVSORACCESSTOE�UIPMENT. MULTIPLE RACEWAYSSHOULD
BE INSTALLED GROUPED TOGETHER. THE LOCATION OF PUBLICLY VISIBLE RACEWAVS SHALL BE APPROVED
BVTHEARCHITECTPRIORTOINSTALLATION. (EXTRATIMESHOl1LDBEALLOWEDFORTHISREVIEWAN�
APPROVAL)
2 THE DISCONNECTING MEANS FOR ALL MECHANICAL EQUIPMENT SHALL BE ACCESSBLE AND HAVE THE
CLEARANCE IN FRONT AS REQUIRED BY NEC AMENDMENTS.
3. ALLCEILINGATTACHEOOBJECTSANDFLOORATTACHEDEpUIPMENTINCLUDING6UTNOTLIMITEDTO
PENDANTLIGHTINGFIXTURES GENERALLIGHTING,MULTIPLERACEWAVS,GENERATOR,TRANSFORMER
ELECTRICAL SW ITCHGEAR, AND SWITCHBOARDS SHALL BE INSTALLED IN ACCORDANCE W ITH SUPPORTING
OBJECTS FOR SEISMIC ZONE AS REpUIRED BV STATE AND LOCAL CODES.
4. ALLSWITCHGEAR,SWITCHBOARDSANDTRANSFORMERSSHALLHAVEA4INCHHOUSEKEEPINGPAD.
11NDER NO CONDITION SHALL THE HIGHEST SW ITCH OR BREAKER E%CEED 6'-6" AFF.
5. DATA GNEN ON THE DRAW INGS IS AS EXACT AS COULD BE SECURED. ABSOLUTE ACCURACV IS NOT
Gl1ARANTEED AND THE CONTRACTOR SHALL OBTAIN AN� VERIFV E%ACT LOCATIONS, MEASUREMENTS,
LEV ELS, SPACE REQUIREMENTS, POTENTIAL CONFUCTS W ITH OTHER TRADES, ETQ AT THE SITE AND $HALL
SATISFACTORILV ADAPT HIS W ORK TO ACTUAL CONDITIONS AT THE BUILDINGS. THE DRAW INGS ARE
DIAGRAMMATICAL IN NATURE AND SHALL NOT BE SCALED. HOW EVER THIS DOES NOT RELIEVE ANV
SUB-CONTRACTOR FROM COORDINATING HIS W ORK W ITH ALL OTHER TRADES AND FROM A�JUSTING HIS
WORKASRE�UIREDBVTHEACTUALCONDITIONSOFTHEPROJECT. THECONTRACTORSHALLVISITTHE
SITE BEFORE SUBMITTMG COSTS TO BECOME THOROUGHLV FAMILIAR WITH THE ACTUAL CONDITIONS OF
THE PROJECT.
6. COORDINATE AND ADJUST ALL WORK BETW EEN TRADES AND E%ISTING CONDITIONS IN ORDER TO
ACCOMPLISH A NEAT, INTEGRATED AND EFFlCIENT WSTALLATION W HICH INCLUDE BUT ARE NOT LIMITED TO:
a. E%AMINE THE CONTR4CT DOCUMENTS OF ALL TR4DE5 QE. THE ARCHITECTURAL REFLECTED CEILWG
PLAN, MECHANICAL HVAC DRAW WGS, ELECTRICAL LIGHTWG PLAN, RRE PROTECTION PLAN, ETC.).
b. COORDINATENECESSARVEQUIPMENT,FIXTURES,ETGSOTHATTHEFINALINSTALLATIONIS
COMPATIBLE W ITH THE MATERIALS AND EQUIPMENT OF THE OTHER TRADES.
c. THIS CONTRQCTOR SHALL ASSIST THE �IVISION 23 CONTRACTOR IN PREPARING SHOP DRAWINGS
FOR COORDINATWG INSTALLATION OF ALL WORK QE LOCATING ALL LIGHTING FlXTURES IN CBLING
W ITH CEILING QEARANCES, RACEWAVS, PIPING, EQUIPMENT FOR QEARANCE THROUGHOUT�.
tl. THEELECTRICALDRAWINGSINDICATETHEELECTRICALREQUIREMENTSFORASIGMFlCANT
PORTION OF THE MECHANICAL AND PLUMBING SVSTEMS. AD�ITIONAL MECHANICAL AND PLUMBING
EOUIPMENT IS INDICATED ON THE DIVISION 21E DRAW INGS. REFER TO MECHANICAL DRAW INGS AND
SPECIFlCATIONS FOR ADDITIONAL MPoRMATION. PROV IDE COMPLETE W IRING AND FUSIBLE
DISCONNECTING MEANS FOR ALL MECHANICAL AND P W MBING EQUIPMENT.
Z DEFlNITIONS:
a. "FURNISH" MEANS TO "SUPPLV" AND USUALLV REFERS TO AN ITEM OF EpUIPMENT.
b. "WSTALC' MEANS TO "SET IN PLACE, CONNECTAND PLACE IN FULL OPERATIONAL ORDER".
a "PROVIDF'MEANSTO"FURNISHAN�INSTALL".
d. "EQUIVALENT' MEANS "MEETS THE SPECIFICATIONS OF THE REFERENCE PRODl1CT OR ITEM IN ALL
SIGMRCANT ASPECTS." SIGNIRCANT ASPECTS SHALL BE DETERM W ED BV THE ENGMEER.
e. "RE: DIVISION", ANO SIMILAR EXPRESSIONS MEANS WORK TO BE PERFORMED UNDER THE
CONTRACT DOCUMENTS, BUT NOT NECESSARILV UNDER THE DIVISION OR SECTION OF THE
WORK ON WHICH THE NOTE APPEARS. IT IS THE CONTRACTORS SOLE RESPONSIBILITV TO
COORDINATE THE WORK OF THE CONTRACT BETWEEN HIS/HER SUPPLIERS, SUBCONTRACTORS,
AND EMPLOYEES. IF CLARIFlCATION IS REQUIRED, CONSULT ARCHITECT.
8. "FIRESTOPPING" REpUIREMENT. ALL PENETRATIONS THROUGH RATED WALLS ANO FLOORS SHALL BE
SEALED WITH MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT GASSES W HEN
SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPEQFIC FOR FIRE STOPS ASTM-E-814. ALL
PENETRATIONS SHALL MEET F AND T RATINGS AS REQUIRED BV THE BUILDING CODE.
9. W HERE DISCONNECTS ARE INDICATED ON DRAW INGS CONTRACTOR SHALL PROVIDE FINAL CONNECTION TO
EpUIPMENT BEING SERVED BV DISCONNECT.
10. CONTRACTORPROVIDEALLMISCELLANEOUSSUPPORTSASREQUIREDFORACOMPLETEOPERQBLE
ELECTRICAL INSTALLATION INCWO WG MISCELLANEOUS STEEL, UNI-STRUT, ALL-THREAD, AIRCRAFT CABLE,
ETC.
¢
sw
r
N�j
�ww
O�o
Z�O
�Ok�z
_ _ _ _ �
TOPOFCABWET 6 G
TOPOFCABINET CONTROL
�� PANELS
�TOP�FCABINET � ,�
II II
II II
II NOTE:
I I II NSTALLED AT D�FFERENTO BE
I I I I pCATED W ITHIN ONE STU�
� o O ���0 I I I I SHALL ALIGN ERTIC�ALLV, ON
°� 6 6 d o O I I I I THE SAME SIDE OF THE STUD.
�o� � � LL w � z� WHEREWALLMOUNTED
�°'" ^� � � � �` I I d II TELEPHONES OCCUR OVER
wQa � a� Ow Q�" �LL� LIGHTSWITCHES,VOWME
F F m _ ?�> r o a� O¢ O I I I I CONTROLS, ETC.
c�� m0 `f°U',m�m OFFSETONESTUDSPACE.
NPICAL DEVICE MOUNTING HEIGHTS FINISHED FLOOR
NO SCALE
NOTES:
1. MOUNTINGHEIGHTSSHOWNONARCHITECTURALELEVATIONSSHALLGOVERNOVERTHOSESHOWNABOVE.
2 CONTRACTOftSHALLENSURETHATALLMOUNTINGHEIGHTSCOMPLVWITHCURRENTADARE�UIREMENTS.
3. WHEREEVERDEVICESAREINDICATEDTOBEABOVEDOORS,DEVICESHALLBECENTEREDBETVJEENTOPOF
DOOR TRIM AND CEILING LINE.
4. ALL ABOVE COUNTER (DESIGNATE� BV "AC") SHALL BE MOUNTED 8" ABOVE COUNTER OR MAXIMUM HEIGHT OF
44" TO TOP OF DEVICE. VERIFV HEIGHTS W ITH ARCHITECT.
5. FOR CEILINGS BELOW ]'-0", FIRE ALARM STROBE OR HORN/STROBES SHALL BE WALL MOl1NTED 6" BELOW
FlNisNEo cEiuNc.
6. HEIGHTS SHOWN ARE TVPICAL TO CENTERLINE OF BOX UNLE55 NOTED OTHERW ISE. ALL DUPLEX
RECEPTACLES SHALLBE MOUNTEO VERTICALLV.
�. REFERTOARCHITECTURALDRAWINGSFORRECEPTAQEMOUNTINGHEIGHTSSTAN�ARDCONVENIENCE
RECEPTACLES SHALL BE MOUNTED AT HEIGHT INDICATED ABWE WHERE MOUNTING HEIGHT IS NOT SHOW N ON
ARCHITECTURALDOCUMENTS.
8. CONTRACTORSHALLREFERTOARCHITECTURALDRAWINGSDIMENSIONSWHEREAVAILABLEWHEREDEVICES
ARE MOUNTED IN CASEWORK OR MILLWORK, CONTRACTOR SHALL VERIFY EXACT DIMENSIONS PRIOR TO
INSTALLATION.
RELEA5E0 FOR CONSTRUCTION
Suhjec��o compliance with allregula�ions
04 S�a�e antl Local Codes
City of Carmel
r
�un��V l�rc�alols�.
�
DATE: OH�Z5�2O
A.AMP
AC
AF
AFF
AFG
AL
AM
ANN
ANT
ATS
AUTO
AU%
AWG
BFC
eFc
BKR
C
CAB
CAM
CB
CCN
CKT
CO
COMB
COND
CT
CU
as
DGP
DISC
DL
DWG
DVR
E
EA
EC
EF
EG
EHC
ELEC
ELEV
EM
EMT
EOL
E�UIP
EWC
EWH
EXH
F
FA
FACP
FBO
FC
FDR
FLEX
FLR
ABBREVIATIONS
AMPERE
ABOVECOUNTER
AMPEREFUSNFRAME
ABOVE FINISHED FLOOR
ABOVE FINISHEO GRADE
ALUMINUM
AMMETER
ANNl1NCIATOR
ANTENNA
AUTOMATIC TRANSFER SW ITCH
Al1TOMATIC
AUXILIARV
AMERICAN WIRE GAUGE
BELOW FINISHED CEILING
BELOW FINISHEDGRADE
BREAKER
CONDUIT
CABINET
CAMERA
CIRCUIT BREAKER
CLOSED QRCUIT TELEVISION
CIRCUIT
CONDl11T ONLV
COMBINATION
CONDUCTOR
CURRENTTRANSFORMER
COPPER
DEqBEL
OIGITAL GATHERING PANEL
�ISCONNECT
DAMP LISTED
ORAWING
�IGITAL VIDEO RECORDER
EXISTING
EACH
ELECTRICALCONTRACTOR
EXHAUSTFAN
EQUIPMENT GROUND
ELECTRIC HEATING COIL
ELECTRIC OR ELECTRICAL
ELEVATOR
EMERGENCV
ELECTRIC METALLIC TUBING
FIAENO OF LINE RESISTOR
EQUIPMENT
ELECTRIC WATER COOLER
ELECTRIC WATER HEATER
EXHAUST
FUSE
FIRE ALARM
FIRE ALARM CONTROL PANEL
FURNISHED BV OTHERS
FOOTCANDLES
FEEDER
FLEXIBLE
FLOOR
FLUORESCENT
MECHANICAL/PLUMBING COORDINATION
REQUIREMENTS
THE ELECTRICAL DRAW INGS INDICATE THE ELECTRICAL
REQUIREMENTS FOR A SIGNIFICANT PORTION OF THE MECHANICAL
ANO PW MBMG SVSTEMS. ADDITIONAL MECHANICAL AND PWMBING
E�UIPMENT IS IN�ICATED ON THE DIVISION 21, 22,ANo 23 DRAWINGS.
THE ELECTRICAL CONTRACTOR SHALL WCLU�E COSTS IN THE
DIVISION 26 PRICING TO CONNECT ALL MECHANICAL AND PLUMBING
E�UIPMENT INOICATED ON THE ELECTRICAL DRAW INGS AND ON THE
MECHANICAL AND PLUMBING DRAW INGS. PROVIDE COMPLETE W IRING,
STARTERS, AND �ISCONNECTING MEANS FOR ALL MECHANICAL AND
PLUMBWG EQUIPMENT.
FO
G
GALV
GEN
GFl
GFQ
GND
HD
HH
HOA
HP
HPF
HPS
HT
HTR
ID
IG
IMC
INCAND
J-BO%
KCMIL
KVA
KW
KWH
LA
lFC
LTG
LV
MA
MAX
MB
MC
MCB
MCC
MCP
MDP
MECH
MFR
MG
MH
MIN
MLO
MOV
MS
M56
MTD
MTG
MS
MV
N
NEC
NIC
NC
NL
NO
NTS
OC
ABBREVIATIONS
RBER OPTIC
GROUND
GALVANIZED
GENERATOR
GROUN� FAULT CIRCUIT WTERRUPTER
GROUN� FAULT QRCUIT INTERRUPTER
GROUND
HEAVV OUTV
HAND HOLE
HAND-OFF-AUTO
HORSEPOWER
HIGH POWER FACTOR
HIGH PRESSURE SODIUM
HEIGHT
HEATER
INSIDE DIAMETER
ISOLATED GROUN�
WTERMEOIATE GRADE METALLIC CONDUIT
WCANDESCENT
JUNCTION BO%
THOUSAND OF QRCULAR MILLS
KILOVOLT AMPERE
KILOWATT
KILOW ATT HOUR
LIGHTNING ARRESTOR
LIQUIDTIGHT FLEXIBLE CONDUIT
LIGHTING
LOW VOLTAGE
MILLIAMPERE
MAXIMUM
MAIN BREAKER
MECHANICALCONTRACTOR
MAIN CIRCUIT BREAKER
MOTORCONTROLCENTER
MOTOR CIRCUIT PROTECTOR
MAIN DISTRIBUTION PANEL
MECHANICAL
MANUFACTURER
MOTORGENERATOR
MANHOLE OR METAL HALIDE
MINIMUM
MAIN LUGS ONLV
MOTOR OPERATED VALVE
MOTOR STARTER
MAW SWITCHBOARO
MOUNTED
MOUNTING
MOTOR STARTER
MEDIUM VOLTAGE
NEUTRAL
NATIONAL ELECTRICAL CODE
NOTIN CONTRACT
NORMALLY CLOSED
NIGHT LIGHT
NORMALLY OPEN
NOT TO SCALE
ON CENTER
LIGHTING
/e/ � Q� EXIT SIGN WITH BATTERV BACK UP. MOUNTING, FACES AND
I I Y DIRECTIONALARROWS(CHEVRONS)PERPLANS
� VACANCVSENSOR-0EILINGMOUNTED
�OS WIRELESSOCCUPANCVSENSOR-CEILINGMOUNTED
�F WIRELESSLOWVOLTAGESWITCH
�o WIRELESSDIMMERSWITCH
PP POWERPACK
� DAVLIGHT SENSOR
�vs COMBINATION WALL VACANCV SENSOR SW ITCH
NOTE
ALL W IRELESS DEVICES BASED ON LUTRON UNLE55
OTHERW ISE NOTED. ALL LIGHT FIXTURES SHALL BE FULLV
COMPATIBLE WITH LUTRON CONTROL DEVICES.
CEILING SENSORS SHALL HAVE 360 DEGREE R4NGE W ITH
MIN 1500 SF COVERAGE.
ALL LIGHTING CONTROLS SHOWN FOR REFERENCE, REFER
TO LIGHTING DESIGNER PLANS FORZONING, DEVICE
LOCATIONS ETC.
COMMUNICATIONS
� TEIJDATA WALL OUTLET. WITH 3/4" EMPTV WNDUIT
UP TO 6" ABOVE CEILING LEVEL
Q WALLMOUNTEOCOMBINATIONPOWER/OATA/AV
RECEPTACLE OUTLET
TGB TELECOMMUNICATIONS GROUND BUS.
lT
GENERALNOTES:
L TECHNOLOGV DEVICES SHOWN FOR REFERENCE ONLV, UNO. PROVIDE
BACKBO%ES AND 1" CONDUIT W ITH DRAG W IRE STUBBED UP TO 6"
ABOVE FINISHED CEILING, UNO.
RACEWAYLEGEND
BRANCH CIRW IT HOMERUN TO PANELBOARD, NUMBER OF ARROWS
INDICATESNUMBEROFqRCUITS.NUMERALINDICATES CIRCUIT
q-zq Nl1MBER.
� CONDUITUP
� CONDUITDOWN
— — — — CONDUIiRUNSUNDERFL00R
CON�UIT RUN CONCEALE� IN WALLS OR CEILING, OR EXPOSE� WHEN
CEILINGS ARE NOT PRESEM.
��� MOTORWNNECTION
SECURITY-ACCESS CONTROL
CR WALLMOUNTEOCARDREADER
M� ELECTROMAGNETICLOCK
EDR EMERGENCV DOOR RELEASE PULL
OS OCCUPANCVSENSOR RELEASE
REX PUSH TO EXIT RELEASE BUTTON
NOTES:
1. DEVICESSHOWNFORREFERENCEONLV.PROVIDEBACKBOXESAND
CONDUIT AS REQUIRED. REFER TO SECURITV VENDOR DRAW WGS
EQUIPMENT
a
�
a
�
G
6
�
�io
fT0
�l
3�
�i U�
MOTOR
MOTOR STARTER
UN-FUSED DISCONNECT
FUSE� DISCONNECT
BRANCH CIRCUIT OR POW ER PANEL
LIGHTING CONTROL PANEL
MECHANICAL E�UIPMENT IDENTIFICATION TAG
THERMALOVERLOADSWITCH
MOTOR W ITH THERMAL OVERLOAD SW ITCH
MOTOR W ITH DISCONNECT SW ITCH - UPPER
NUMERAL DENOTES SW ITCH SRE, UNF DENOTES
UNFUSED
POWER DEVICES
111
11�
Q
O
��/
4❑
WALLDUPLEX RECEPTACLE
WALL DUPLEX RECEPTACLE (DEDICATED) SEE
RECEPTACLE MODIFIER TAG BELOW FOR AODITIONAL
WFORMATION
WALLFOURPLE% RECEPTACLE
WALL FOURPLEX RECEPTACLE (DEDICATED)
WALL JUNCTION BOX
CEILING JUNCTION BOX
"CP"DENOTESCONDENSATEPUMP
CEILWG DUPLEX RECEPTACLE
CEILING FOURPLEX RECEPTACLE
POWERPOKETHRU WITHQUADRECEPTA0.E,
BLACK COVER - LEGRAND 8" EVOLUTION SERIES
SATC2PBK
PLAN KEV NOTE
GENERAL NOTES:
1. REFER TO SPEQFICATION SECTION 26 2] 2fi FOR SPECIFIC FLOOR
PRO�UCT INFORMATION.
2. REFERTOTECHNOLOGVLEGENDANDFLOORPLANSTOCONFIRMALL
LOCATIONS THAT HAVE DATA OR DATAIAV REpUIREMENTS COMBINED
W ITH POW ER IN FLOOR BOXES.
3. REFER TO TECHNOLOGV (AND/OR AV) DRAW INGS FOR DEDICATED LOW
VOLTAGE CON�UIT AND ROOR BOX DEVICE MOUNTMG PLATE
REQUIREMENTS LOW VOLTAGE CONDUIT REQUIREMENTS ARE NOT
DOCUMENTEDONPOWERDRAWINGS.
4. COLOROFALLDEVICESSHALLBEASPERARCHITECT
SPECIFICATIONS.
FIRE ALARM
� E SMOKE DETECTOR "E" DENOTES EXISTING TO REMAIN
�ER SMOKE DETECTOR W ITH ELEVATOR RECALL
� X WALL MOUNTED HORN / STROBE
�X
CEILING MOUNTED HORN / STROBE
,1CX WALLMOUNTEDADASTROBE
:l X CEILING MOUNTED ADA STROBE
FR FIREALARMRELAY
NOTES:
1. 'X' OENOTES CANDELLA RATING OF STROBE.
1�1
INDUSTRIOUS
CJb�;�RKiNG
880 W MONON GREEN BLVD
CARMEL qTV, IN 460323
OWNERRENANi
INDUSTRIOUS
215PARKAVES,4E1300
NEW YORK, NY 10003
ARCNI7ECTOFRECORD
NORF
325 N LASALLE Si- SOIiE SCO
CHICAGO. IL 60654
PEiER.DUBINCPNORR-COM
312-0242400
MEFENG/NEER
MEENGINEERS
29 WEST 38iH SiREEL SiH FLOOR
NEW YORK. NY 10018
CONiAQ: BRIAN SHASSIAN
BRIANSHASSIAN@ME-ENGINEER$_COM
JOHN HIGGINS
JOHN.HIGGWSQMEENGINEERS.COM
�212J 44]-6]]0 PHONE
LIGHi1NGDESIGNER
REGENCY
9261 JOkDAN AVE
CHAiSWORiH, CA
800-28d-2026
ISSUEDATES
REV. DAiE DESCRIPiION
06/OS/2020 DD3
06/18/2020 CDvI
0]/06/2020 CDv2
0]/16/2020 PERMIT
SEAL & SIGNATURE
BY CHECK
ME ME
ME ME
ME ME
ME ME
PR0./ECTNAME
CARMEL CITY- 880 MONON GREEN
VROJECiNUMBER
IND880MON
DRAWING TIiLE
ELECTRICAL LE6END
SCALE
7/8„_ ��_�„
SHEETNUMBER
E-000
oF