Loading...
HomeMy WebLinkAboutE000 Electrical LegendNOTES: 1. ALLEXPOSEDRACEWAVSARETOBEINSTALLEDPARALLELORPERPEN�ICULARTOWALLSORSTRUCTURAL MEMBERS Sl1CH THAT THEV FOLLOW STRUCTURAL SURFACE CONTOURS AND SHALL BE INSTALLED Sl1CH THATTHEVDONOTOBSTRUCTPASSAGEWAVSORACCESSTOE�UIPMENT. MULTIPLE RACEWAYSSHOULD BE INSTALLED GROUPED TOGETHER. THE LOCATION OF PUBLICLY VISIBLE RACEWAVS SHALL BE APPROVED BVTHEARCHITECTPRIORTOINSTALLATION. (EXTRATIMESHOl1LDBEALLOWEDFORTHISREVIEWAN� APPROVAL) 2 THE DISCONNECTING MEANS FOR ALL MECHANICAL EQUIPMENT SHALL BE ACCESSBLE AND HAVE THE CLEARANCE IN FRONT AS REQUIRED BY NEC AMENDMENTS. 3. ALLCEILINGATTACHEOOBJECTSANDFLOORATTACHEDEpUIPMENTINCLUDING6UTNOTLIMITEDTO PENDANTLIGHTINGFIXTURES GENERALLIGHTING,MULTIPLERACEWAVS,GENERATOR,TRANSFORMER ELECTRICAL SW ITCHGEAR, AND SWITCHBOARDS SHALL BE INSTALLED IN ACCORDANCE W ITH SUPPORTING OBJECTS FOR SEISMIC ZONE AS REpUIRED BV STATE AND LOCAL CODES. 4. ALLSWITCHGEAR,SWITCHBOARDSANDTRANSFORMERSSHALLHAVEA4INCHHOUSEKEEPINGPAD. 11NDER NO CONDITION SHALL THE HIGHEST SW ITCH OR BREAKER E%CEED 6'-6" AFF. 5. DATA GNEN ON THE DRAW INGS IS AS EXACT AS COULD BE SECURED. ABSOLUTE ACCURACV IS NOT Gl1ARANTEED AND THE CONTRACTOR SHALL OBTAIN AN� VERIFV E%ACT LOCATIONS, MEASUREMENTS, LEV ELS, SPACE REQUIREMENTS, POTENTIAL CONFUCTS W ITH OTHER TRADES, ETQ AT THE SITE AND $HALL SATISFACTORILV ADAPT HIS W ORK TO ACTUAL CONDITIONS AT THE BUILDINGS. THE DRAW INGS ARE DIAGRAMMATICAL IN NATURE AND SHALL NOT BE SCALED. HOW EVER THIS DOES NOT RELIEVE ANV SUB-CONTRACTOR FROM COORDINATING HIS W ORK W ITH ALL OTHER TRADES AND FROM A�JUSTING HIS WORKASRE�UIREDBVTHEACTUALCONDITIONSOFTHEPROJECT. THECONTRACTORSHALLVISITTHE SITE BEFORE SUBMITTMG COSTS TO BECOME THOROUGHLV FAMILIAR WITH THE ACTUAL CONDITIONS OF THE PROJECT. 6. COORDINATE AND ADJUST ALL WORK BETW EEN TRADES AND E%ISTING CONDITIONS IN ORDER TO ACCOMPLISH A NEAT, INTEGRATED AND EFFlCIENT WSTALLATION W HICH INCLUDE BUT ARE NOT LIMITED TO: a. E%AMINE THE CONTR4CT DOCUMENTS OF ALL TR4DE5 QE. THE ARCHITECTURAL REFLECTED CEILWG PLAN, MECHANICAL HVAC DRAW WGS, ELECTRICAL LIGHTWG PLAN, RRE PROTECTION PLAN, ETC.). b. COORDINATENECESSARVEQUIPMENT,FIXTURES,ETGSOTHATTHEFINALINSTALLATIONIS COMPATIBLE W ITH THE MATERIALS AND EQUIPMENT OF THE OTHER TRADES. c. THIS CONTRQCTOR SHALL ASSIST THE �IVISION 23 CONTRACTOR IN PREPARING SHOP DRAWINGS FOR COORDINATWG INSTALLATION OF ALL WORK QE LOCATING ALL LIGHTING FlXTURES IN CBLING W ITH CEILING QEARANCES, RACEWAVS, PIPING, EQUIPMENT FOR QEARANCE THROUGHOUT�. tl. THEELECTRICALDRAWINGSINDICATETHEELECTRICALREQUIREMENTSFORASIGMFlCANT PORTION OF THE MECHANICAL AND PLUMBING SVSTEMS. AD�ITIONAL MECHANICAL AND PLUMBING EOUIPMENT IS INDICATED ON THE DIVISION 21E DRAW INGS. REFER TO MECHANICAL DRAW INGS AND SPECIFlCATIONS FOR ADDITIONAL MPoRMATION. PROV IDE COMPLETE W IRING AND FUSIBLE DISCONNECTING MEANS FOR ALL MECHANICAL AND P W MBING EQUIPMENT. Z DEFlNITIONS: a. "FURNISH" MEANS TO "SUPPLV" AND USUALLV REFERS TO AN ITEM OF EpUIPMENT. b. "WSTALC' MEANS TO "SET IN PLACE, CONNECTAND PLACE IN FULL OPERATIONAL ORDER". a "PROVIDF'MEANSTO"FURNISHAN�INSTALL". d. "EQUIVALENT' MEANS "MEETS THE SPECIFICATIONS OF THE REFERENCE PRODl1CT OR ITEM IN ALL SIGMRCANT ASPECTS." SIGNIRCANT ASPECTS SHALL BE DETERM W ED BV THE ENGMEER. e. "RE: DIVISION", ANO SIMILAR EXPRESSIONS MEANS WORK TO BE PERFORMED UNDER THE CONTRACT DOCUMENTS, BUT NOT NECESSARILV UNDER THE DIVISION OR SECTION OF THE WORK ON WHICH THE NOTE APPEARS. IT IS THE CONTRACTORS SOLE RESPONSIBILITV TO COORDINATE THE WORK OF THE CONTRACT BETWEEN HIS/HER SUPPLIERS, SUBCONTRACTORS, AND EMPLOYEES. IF CLARIFlCATION IS REQUIRED, CONSULT ARCHITECT. 8. "FIRESTOPPING" REpUIREMENT. ALL PENETRATIONS THROUGH RATED WALLS ANO FLOORS SHALL BE SEALED WITH MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT GASSES W HEN SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPEQFIC FOR FIRE STOPS ASTM-E-814. ALL PENETRATIONS SHALL MEET F AND T RATINGS AS REQUIRED BV THE BUILDING CODE. 9. W HERE DISCONNECTS ARE INDICATED ON DRAW INGS CONTRACTOR SHALL PROVIDE FINAL CONNECTION TO EpUIPMENT BEING SERVED BV DISCONNECT. 10. CONTRACTORPROVIDEALLMISCELLANEOUSSUPPORTSASREQUIREDFORACOMPLETEOPERQBLE ELECTRICAL INSTALLATION INCWO WG MISCELLANEOUS STEEL, UNI-STRUT, ALL-THREAD, AIRCRAFT CABLE, ETC. ¢ sw r N�j �ww O�o Z�O �Ok�z _ _ _ _ � TOPOFCABWET 6 G TOPOFCABINET CONTROL �� PANELS �TOP�FCABINET � ,� II II II II II NOTE: I I II NSTALLED AT D�FFERENTO BE I I I I pCATED W ITHIN ONE STU� � o O ���0 I I I I SHALL ALIGN ERTIC�ALLV, ON °� 6 6 d o O I I I I THE SAME SIDE OF THE STUD. �o� � � LL w � z� WHEREWALLMOUNTED �°'" ^� � � � �` I I d II TELEPHONES OCCUR OVER wQa � a� Ow Q�" �LL� LIGHTSWITCHES,VOWME F F m _ ?�> r o a� O¢ O I I I I CONTROLS, ETC. c�� m0 `f°U',m�m OFFSETONESTUDSPACE. NPICAL DEVICE MOUNTING HEIGHTS FINISHED FLOOR NO SCALE NOTES: 1. MOUNTINGHEIGHTSSHOWNONARCHITECTURALELEVATIONSSHALLGOVERNOVERTHOSESHOWNABOVE. 2 CONTRACTOftSHALLENSURETHATALLMOUNTINGHEIGHTSCOMPLVWITHCURRENTADARE�UIREMENTS. 3. WHEREEVERDEVICESAREINDICATEDTOBEABOVEDOORS,DEVICESHALLBECENTEREDBETVJEENTOPOF DOOR TRIM AND CEILING LINE. 4. ALL ABOVE COUNTER (DESIGNATE� BV "AC") SHALL BE MOUNTED 8" ABOVE COUNTER OR MAXIMUM HEIGHT OF 44" TO TOP OF DEVICE. VERIFV HEIGHTS W ITH ARCHITECT. 5. FOR CEILINGS BELOW ]'-0", FIRE ALARM STROBE OR HORN/STROBES SHALL BE WALL MOl1NTED 6" BELOW FlNisNEo cEiuNc. 6. HEIGHTS SHOWN ARE TVPICAL TO CENTERLINE OF BOX UNLE55 NOTED OTHERW ISE. ALL DUPLEX RECEPTACLES SHALLBE MOUNTEO VERTICALLV. �. REFERTOARCHITECTURALDRAWINGSFORRECEPTAQEMOUNTINGHEIGHTSSTAN�ARDCONVENIENCE RECEPTACLES SHALL BE MOUNTED AT HEIGHT INDICATED ABWE WHERE MOUNTING HEIGHT IS NOT SHOW N ON ARCHITECTURALDOCUMENTS. 8. CONTRACTORSHALLREFERTOARCHITECTURALDRAWINGSDIMENSIONSWHEREAVAILABLEWHEREDEVICES ARE MOUNTED IN CASEWORK OR MILLWORK, CONTRACTOR SHALL VERIFY EXACT DIMENSIONS PRIOR TO INSTALLATION. RELEA5E0 FOR CONSTRUCTION Suhjec��o compliance with allregula�ions 04 S�a�e antl Local Codes City of Carmel r �un��V l�rc�alols�. � DATE: OH�Z5�2O A.AMP AC AF AFF AFG AL AM ANN ANT ATS AUTO AU% AWG BFC eFc BKR C CAB CAM CB CCN CKT CO COMB COND CT CU as DGP DISC DL DWG DVR E EA EC EF EG EHC ELEC ELEV EM EMT EOL E�UIP EWC EWH EXH F FA FACP FBO FC FDR FLEX FLR ABBREVIATIONS AMPERE ABOVECOUNTER AMPEREFUSNFRAME ABOVE FINISHED FLOOR ABOVE FINISHEO GRADE ALUMINUM AMMETER ANNl1NCIATOR ANTENNA AUTOMATIC TRANSFER SW ITCH Al1TOMATIC AUXILIARV AMERICAN WIRE GAUGE BELOW FINISHED CEILING BELOW FINISHEDGRADE BREAKER CONDUIT CABINET CAMERA CIRCUIT BREAKER CLOSED QRCUIT TELEVISION CIRCUIT CONDl11T ONLV COMBINATION CONDUCTOR CURRENTTRANSFORMER COPPER DEqBEL OIGITAL GATHERING PANEL �ISCONNECT DAMP LISTED ORAWING �IGITAL VIDEO RECORDER EXISTING EACH ELECTRICALCONTRACTOR EXHAUSTFAN EQUIPMENT GROUND ELECTRIC HEATING COIL ELECTRIC OR ELECTRICAL ELEVATOR EMERGENCV ELECTRIC METALLIC TUBING FIAENO OF LINE RESISTOR EQUIPMENT ELECTRIC WATER COOLER ELECTRIC WATER HEATER EXHAUST FUSE FIRE ALARM FIRE ALARM CONTROL PANEL FURNISHED BV OTHERS FOOTCANDLES FEEDER FLEXIBLE FLOOR FLUORESCENT MECHANICAL/PLUMBING COORDINATION REQUIREMENTS THE ELECTRICAL DRAW INGS INDICATE THE ELECTRICAL REQUIREMENTS FOR A SIGNIFICANT PORTION OF THE MECHANICAL ANO PW MBMG SVSTEMS. ADDITIONAL MECHANICAL AND PWMBING E�UIPMENT IS IN�ICATED ON THE DIVISION 21, 22,ANo 23 DRAWINGS. THE ELECTRICAL CONTRACTOR SHALL WCLU�E COSTS IN THE DIVISION 26 PRICING TO CONNECT ALL MECHANICAL AND PLUMBING E�UIPMENT INOICATED ON THE ELECTRICAL DRAW INGS AND ON THE MECHANICAL AND PLUMBING DRAW INGS. PROVIDE COMPLETE W IRING, STARTERS, AND �ISCONNECTING MEANS FOR ALL MECHANICAL AND PLUMBWG EQUIPMENT. FO G GALV GEN GFl GFQ GND HD HH HOA HP HPF HPS HT HTR ID IG IMC INCAND J-BO% KCMIL KVA KW KWH LA lFC LTG LV MA MAX MB MC MCB MCC MCP MDP MECH MFR MG MH MIN MLO MOV MS M56 MTD MTG MS MV N NEC NIC NC NL NO NTS OC ABBREVIATIONS RBER OPTIC GROUND GALVANIZED GENERATOR GROUN� FAULT CIRCUIT WTERRUPTER GROUN� FAULT QRCUIT INTERRUPTER GROUND HEAVV OUTV HAND HOLE HAND-OFF-AUTO HORSEPOWER HIGH POWER FACTOR HIGH PRESSURE SODIUM HEIGHT HEATER INSIDE DIAMETER ISOLATED GROUN� WTERMEOIATE GRADE METALLIC CONDUIT WCANDESCENT JUNCTION BO% THOUSAND OF QRCULAR MILLS KILOVOLT AMPERE KILOWATT KILOW ATT HOUR LIGHTNING ARRESTOR LIQUIDTIGHT FLEXIBLE CONDUIT LIGHTING LOW VOLTAGE MILLIAMPERE MAXIMUM MAIN BREAKER MECHANICALCONTRACTOR MAIN CIRCUIT BREAKER MOTORCONTROLCENTER MOTOR CIRCUIT PROTECTOR MAIN DISTRIBUTION PANEL MECHANICAL MANUFACTURER MOTORGENERATOR MANHOLE OR METAL HALIDE MINIMUM MAIN LUGS ONLV MOTOR OPERATED VALVE MOTOR STARTER MAW SWITCHBOARO MOUNTED MOUNTING MOTOR STARTER MEDIUM VOLTAGE NEUTRAL NATIONAL ELECTRICAL CODE NOTIN CONTRACT NORMALLY CLOSED NIGHT LIGHT NORMALLY OPEN NOT TO SCALE ON CENTER LIGHTING /e/ � Q� EXIT SIGN WITH BATTERV BACK UP. MOUNTING, FACES AND I I Y DIRECTIONALARROWS(CHEVRONS)PERPLANS � VACANCVSENSOR-0EILINGMOUNTED �OS WIRELESSOCCUPANCVSENSOR-CEILINGMOUNTED �F WIRELESSLOWVOLTAGESWITCH �o WIRELESSDIMMERSWITCH PP POWERPACK � DAVLIGHT SENSOR �vs COMBINATION WALL VACANCV SENSOR SW ITCH NOTE ALL W IRELESS DEVICES BASED ON LUTRON UNLE55 OTHERW ISE NOTED. ALL LIGHT FIXTURES SHALL BE FULLV COMPATIBLE WITH LUTRON CONTROL DEVICES. CEILING SENSORS SHALL HAVE 360 DEGREE R4NGE W ITH MIN 1500 SF COVERAGE. ALL LIGHTING CONTROLS SHOWN FOR REFERENCE, REFER TO LIGHTING DESIGNER PLANS FORZONING, DEVICE LOCATIONS ETC. COMMUNICATIONS � TEIJDATA WALL OUTLET. WITH 3/4" EMPTV WNDUIT UP TO 6" ABOVE CEILING LEVEL Q WALLMOUNTEOCOMBINATIONPOWER/OATA/AV RECEPTACLE OUTLET TGB TELECOMMUNICATIONS GROUND BUS. lT GENERALNOTES: L TECHNOLOGV DEVICES SHOWN FOR REFERENCE ONLV, UNO. PROVIDE BACKBO%ES AND 1" CONDUIT W ITH DRAG W IRE STUBBED UP TO 6" ABOVE FINISHED CEILING, UNO. RACEWAYLEGEND BRANCH CIRW IT HOMERUN TO PANELBOARD, NUMBER OF ARROWS INDICATESNUMBEROFqRCUITS.NUMERALINDICATES CIRCUIT q-zq Nl1MBER. � CONDUITUP � CONDUITDOWN — — — — CONDUIiRUNSUNDERFL00R CON�UIT RUN CONCEALE� IN WALLS OR CEILING, OR EXPOSE� WHEN CEILINGS ARE NOT PRESEM. ��� MOTORWNNECTION SECURITY-ACCESS CONTROL CR WALLMOUNTEOCARDREADER M� ELECTROMAGNETICLOCK EDR EMERGENCV DOOR RELEASE PULL OS OCCUPANCVSENSOR RELEASE REX PUSH TO EXIT RELEASE BUTTON NOTES: 1. DEVICESSHOWNFORREFERENCEONLV.PROVIDEBACKBOXESAND CONDUIT AS REQUIRED. REFER TO SECURITV VENDOR DRAW WGS EQUIPMENT a � a � G 6 � �io fT0 �l 3� �i U� MOTOR MOTOR STARTER UN-FUSED DISCONNECT FUSE� DISCONNECT BRANCH CIRCUIT OR POW ER PANEL LIGHTING CONTROL PANEL MECHANICAL E�UIPMENT IDENTIFICATION TAG THERMALOVERLOADSWITCH MOTOR W ITH THERMAL OVERLOAD SW ITCH MOTOR W ITH DISCONNECT SW ITCH - UPPER NUMERAL DENOTES SW ITCH SRE, UNF DENOTES UNFUSED POWER DEVICES 111 11� Q O ��/ 4❑ WALLDUPLEX RECEPTACLE WALL DUPLEX RECEPTACLE (DEDICATED) SEE RECEPTACLE MODIFIER TAG BELOW FOR AODITIONAL WFORMATION WALLFOURPLE% RECEPTACLE WALL FOURPLEX RECEPTACLE (DEDICATED) WALL JUNCTION BOX CEILING JUNCTION BOX "CP"DENOTESCONDENSATEPUMP CEILWG DUPLEX RECEPTACLE CEILING FOURPLEX RECEPTACLE POWERPOKETHRU WITHQUADRECEPTA0.E, BLACK COVER - LEGRAND 8" EVOLUTION SERIES SATC2PBK PLAN KEV NOTE GENERAL NOTES: 1. REFER TO SPEQFICATION SECTION 26 2] 2fi FOR SPECIFIC FLOOR PRO�UCT INFORMATION. 2. REFERTOTECHNOLOGVLEGENDANDFLOORPLANSTOCONFIRMALL LOCATIONS THAT HAVE DATA OR DATAIAV REpUIREMENTS COMBINED W ITH POW ER IN FLOOR BOXES. 3. REFER TO TECHNOLOGV (AND/OR AV) DRAW INGS FOR DEDICATED LOW VOLTAGE CON�UIT AND ROOR BOX DEVICE MOUNTMG PLATE REQUIREMENTS LOW VOLTAGE CONDUIT REQUIREMENTS ARE NOT DOCUMENTEDONPOWERDRAWINGS. 4. COLOROFALLDEVICESSHALLBEASPERARCHITECT SPECIFICATIONS. FIRE ALARM � E SMOKE DETECTOR "E" DENOTES EXISTING TO REMAIN �ER SMOKE DETECTOR W ITH ELEVATOR RECALL � X WALL MOUNTED HORN / STROBE �X CEILING MOUNTED HORN / STROBE ,1CX WALLMOUNTEDADASTROBE :l X CEILING MOUNTED ADA STROBE FR FIREALARMRELAY NOTES: 1. 'X' OENOTES CANDELLA RATING OF STROBE. 1�1 INDUSTRIOUS CJb�;�RKiNG 880 W MONON GREEN BLVD CARMEL qTV, IN 460323 OWNERRENANi INDUSTRIOUS 215PARKAVES,4E1300 NEW YORK, NY 10003 ARCNI7ECTOFRECORD NORF 325 N LASALLE Si- SOIiE SCO CHICAGO. IL 60654 PEiER.DUBINCPNORR-COM 312-0242400 MEFENG/NEER MEENGINEERS 29 WEST 38iH SiREEL SiH FLOOR NEW YORK. NY 10018 CONiAQ: BRIAN SHASSIAN BRIANSHASSIAN@ME-ENGINEER$_COM JOHN HIGGINS JOHN.HIGGWSQMEENGINEERS.COM �212J 44]-6]]0 PHONE LIGHi1NGDESIGNER REGENCY 9261 JOkDAN AVE CHAiSWORiH, CA 800-28d-2026 ISSUEDATES REV. DAiE DESCRIPiION 06/OS/2020 DD3 06/18/2020 CDvI 0]/06/2020 CDv2 0]/16/2020 PERMIT SEAL & SIGNATURE BY CHECK ME ME ME ME ME ME ME ME PR0./ECTNAME CARMEL CITY- 880 MONON GREEN VROJECiNUMBER IND880MON DRAWING TIiLE ELECTRICAL LE6END SCALE 7/8„_ ��_�„ SHEETNUMBER E-000 oF