HomeMy WebLinkAboutE021 Electrical SpecsPART3-ExECUTION 3.1 W IRING METHOD A. USETHEFOLLOWMGWIRINGMETHODSASINDICATED: INSTALLWIRIN6INRACEWAVINMECHANICALROOMS ELECTRICALROOMS EXTERIORSPACES TOMECHANICALEQUIPMENTORWHERESUBJECTTOPHVSICALDAMAGE. POWERANDCONTROL W IRING SHALL BE INSTALLED IN SEPARATE RACEWAVS. B. MC CABLE CAN BE UTILIZED FOR BRANCH CIRCUITS E IN EXPOSED AND CONCEALED SPACES. 32 INSTALL4TION OF W IRES ANO CABLES A. GENERAL INSTALL ELECTRICAL CABLES, W IRES, AND CONNECTORS IN COMPLIANCE WITH NEC. B. COORDINATE CABLE AND W IRE INSTALLATION WITH OTHER WORK. Q DO NOT WSTALL MORE CONDUCTORS IN A R4CEWAY THAN INDICATED ON THE �RAW INGS. A MAXIMUM OF THREE BRANCH QRCUITS ARE TO BE INSTALLED IN ANV ONE CONDUIT ON A 3-PHASE, 4-W IRE SVSTEM, UNLESS SPECIFICALLV NOTED OTHERWISE ON THE DRAW INGS. WHEN MORE THAN THREE BR4NCH CIRCUITS ARE INSTALLED IN A RACEWAV, THE CONDIICTOR SIZE SHALL BE INCREASE PER CODE FOR DERATING. NO TWO BRANCH qRCUITS OF THE SAME PHASE ARE TO BE INSTALLED IN THE SAME CONDUIT, UNLESS SPEQRCALLV NOTED OTHERW ISE ON THE DRAW IN6S. D. WHEREMULTIPLECIRCUITSSHAREACOMMONNEUTRALCONDUCTOR,PROVIDEBREAKERTIE BARS AS REQl11RE0 SO OVERLOAO ON ONE POLE W ILL TRIP ALL POLES SIMULTANEOl15LV. E. MINIMUM W IRE SIZE SHALL BE A N0.12 AW G EXCEPT FOR CONTROL OR SIGNAL CIRCUITS, W HICH MAV BE NO. 14 AWG. F UNLESS OTHERW ISE INDICATED ON DRAWINGS, ALL W IRING FOR BRANCH CIRCUITS SHALL BE A MINIMUM NO. 12 AW G, PROTECTED BV 20 AMPERES CIRCUIT BREAKERS. IF �ISTANCE FROM PANEL TO FIRST OUTLET IS ]5 FEET OR GREATER FOR 120 VOLT CIRCUITS, AND 125 FEET OR GREATER FOR 2]7 VOLT CIRWITS, N0. 10 AWG SHALL BE INSTALLED THROUGHOUT THE qRCUIT, UNLESS NOTED OTHERW ISE ON THE DRAW INGS. 6. SIZEOFCURRENTCARRVINGCONDUCTORS.UNLESSNOTEDOTHERWISEONDRAWMG$SHALLBE �ETERMINED FROM TABLE 310-06 OF THE LATEST NATIONAL ELECTRIC COOE FOR THE LOA� SERVE� H. PULL CONDUCTORS SIMULTANEOUSLV WHERE MORE THAN ONE IS BEING INSTALLED IN SAME RACEWAV. USE UL LISTED PULLING COMPOUND OR LUBRICANT, W HERE NECESSARV. I. USE PULLING MEANS INCLUDING FlSH TAPE, CABLE, ROPE, AND BASKET WEAVE WIREICABLE GRIPS WHICH W ILL NOT DAMAGE CABLES OR R4CEWAVS. 00 NOT USE ROPE HITCHES FOR PULLING ATTACHMENT TO WIRE OR CABLE. J.SIZE OF CONDUITS, UNLESS SPECIFICALLV SHOWN, SHALL BE DETERMMED FROM APPENDIX C OF THE LATEST NATIONAL ELECTRICAL CODE. K. KEEP CONDUCTOR SPLICE TO MINIMUM. ALL SPLICES SHALL BE MADE W ITHIN JUNCTION BOXES, W IRING TROUGHS AND OTHER ENCLOSURES AS PERMITTED BV THE NATIONAL ELECTRICAL CODE. 00 NOT SPLICE CONDUCTORS IN PANELBOARDS, SAFETY SW ITCHES, SW ITCHBOARDS, MOTOR CONTROLCENTERSORMOTORCONTROLENCLOSURES.SPLICESINCONDUCTORS WSTALLED BELOW GRADE W ILL NOT BE PERMITTED, UNLESS APPROVED IN W RITING BV THE ARCHITECT. L. INSTALL SPLICE AND TAP CONNECTORS. W HICH POSSE55 EpUIVALENT OR BETTER MECHANICAL STRENGTH AND INSULATION RATHER THAN CONDUCTORS BEING SPLICED. M. USE SPLICE AND TAP CONNECTORS WHICH ARE COMPATIBLE W ITH CONDUCTOR MATERIAL. N. PROVIDE ADEpUATE LENGTH OF CONDUCTORS W ITHIN ELECTRICAL ENCLOSURES AND TRAIN THE CONDUCTORS TO TERMINAL POINTS W ITH NO EXCESS. BUNDLE MULTIPLE CONDUCTORS, WITH CONDUCTORSLARGERTHANN0.10AWGCABLEDININDNIDUALQRCUITS. MAKETERMINATIONS SO THERE IS NO BARE CONDUCTOR AT THE TERMINAL. O. TIGHTENELECTRICALCONNECTORSANDTERMINALS,INCW�INGSCREWSANDBOLTS,IN ACCORDANCEWITHMANUFACTURERS'PUBLISHEDTORQUETIGHTENINGVALUES. WHERE MANUFACTURERS' TORQUE REQUIREMENTS ARE NOT INDICATED, TIGHTEN CONNECTORS AND TERMINALS TO COMPLY W ITH TIGHTENING TORQUE VAW ES SPECIFIED IN UL 486A AND UL 4866. 3.3 FIELD QUALITV CONTROL A. PRIOR TO ENERGIZING CHECK INSTALLED W IRES AN� CABLES W ITH MEGOHM METER TO DETERMME INSULATION RESISTANCE LEVELS TO ASSURE REQUIREMENTS ARE FULFlLLED. B. PRIOR TO ENERGIZING, TEST W IRES AND CABLES FOR ELECTRICAL CONTINUITV AND FOR SHORT CIRCUITS. G SUBSEpUENT TO W IRE AND CABLE HOOK-UPS, ENERGIZE CIRCUITS AND OEMONSTRATE PROPER FUNCTIONING. CORRECT MALFUNCTIONING UNITS, AND RETEST TO DEMONSTRATE COMPLIANCE. D. PRIORTOCOMPLETIONOFPROJECT,ANMFRAREDSCANOFSWITCHGEARANDPANELBOARD FEEDER EQUIPMENT CONNECTION SHALL BE PERFORMED W HEN ALL LOADS ARE ENERGIZED. E. TABLE L COLOR CODING FOR PHASE IDENTIFICATION: 1. COLOR CODE SECONDARV SERVICE, FEEDER, AND BRANCH CIRCUIT CONDUCTORS WITH FACTORV APPLIED COLOR AS FOLLOW S: 208V/120 VOLTS PHASE 480V2]� VOLTS BLACK A BROWN RE� B ORANGE BWE C VELLOW WHITE NEUTRAL GRAV GREEN GROUND GREEN END OF SECTION 26a519 SECTION 260533 - RACEWAVS AND BOXES PART1-GENERAL 1.iRELATEDDOCUMENTS A. �RAWINGSANDGENERALPROVISIONSOFCONTRACT,INCLUDINGGENERALANDSUPPLEMENTARV CONDITIONS AND DIVISION 1 SPEQFICATION SECTIONS, APPLV TO THIS SECTION. B. REpUIREMENTSOFTHEFOLLOWINGDIVISI0N265ECTIONSAPPLVTOTHISSECTION'. 1. `ELECTRICALREQUIREMENTS" 2. "BASIC MATERIAL AND METHODS" 125UMMARV A. �RAW INGS ARE DIAGR4MMATIC. ALL BENDS, BOXES, FITTINGS, COUPLINGS ARE NOT NECESSARILV SHOW N. SUPPLV AS NECESSARV TO COMPLV W ITH THE NATIONAL ELECTRIC CODE. B. THIS SECTION INCLUDES RACEWAVS FOR ELECTRICAL W IRING. TYPES OF RACEWAYS, BOXES AND RTTINGS IN THIS SECTION INCLUDE THE FOLLOW ING: L ELECTRICALMETALLICTUBING(EMT). 2 FLEXBLEMETALCONDUIT. 3- METAL CLA� CABLE (MC)- 4. SURFACE RACEWAYS. 5. WIREWAV. 6. OUTLET BOXES. ]. JUNCTION BOXES. 8. PULLBOXES. 9. BUSHINGS. 10.LOCKNUTS. 11. KNOCKOUT CLOSURES. C. RELATED SECTIONS: THE FOLLOW ING SECTION CONTAINS REQUIREMENTS THAT RELATE TO THIS SECTION: 1. DIVISION 26 SECTION "RACEWAV AND BOXES" FOR CONDUIT CONNECTORS, FlTTINGS, AND COUPLINGS. 2. DIVISION ] SECTION "FIRESTOPPING" FOR CON�UIT PENETRATIONS THROUGH RATED WALLS AND SLABS. 1 3 SUBMITTALS A. GENERAC SUBMIT THE FOLLOW ING IN ACCOROANCE W ITH CON�ITIONS OF CONTRACT ANo DIVISION 1 SPEqFlCATION SECTION. I:�J:i�L11LN4)il/c\SH:alilaS�]�P1yqN[Htl:iH�DIN6Y 1. RACEWAVSANDFITTINGS. 2. WIREWAVSAN�FITTINGS. 3. BOXES AND FlTTINGS. C. WSTALLATION INSTRUCTIONS: MANUFACTURER'S WRITTEN WSTALLATION WSTRUCTIONS FOR W IREWAY, SURFACE RACEW AV, AND NONMETALLIC RACEWAV PRODUCTS. 1 4 pUALITV ASSURANCE A. ELECTRICAL COMPONENT STANDARD: COMPONENTS AND INSTALLATION SHALL COMPLV W ITH NFPA �0 "NATIONAL ELECTRICAL CODE." B. NEMA COMPLIANCE COMPLV W ITH APPLICABLE REQUIREMENTS OF NEMA STANDARDS PERTAINING TO RACEWAVS. C. UL COMPLIANCE AND LABELING. COMPLV W ITH APPLICABLE REpUIREMENTS OF UL STANDARDS PERTAININGTOELECTRICALRACEWAVSVSTEMS. PROVIDERACEWAVPRODUCTSAN� COMPONENTS LISTED AND LABELED BV UL. D. MANUFACTURERS: FIRMS REGULARLY ENGAGED IN MANUFACTURE OF ELECTRICAL BOXES AND FITTINGS, OF TVPES, SIZES, AND CAPAQTIES REpUIRED, W HOSE PRODUCTS HAVE BEEN IN SATISFACTORV USE IN SIMILAR SERVICE FOR NOT LESS THAN FIVE VEARS. E INSTALLER'S QUALIFlCATIONS: FIRMS W ITH AT LEAST FlVE VEARS OF SUCCESSFUL WSTALLATION owornoniro nni oon iorTe i iTn ninir o�CTRICAL BOXES AND RTTINGS SIMILAR TO THOSE RELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel r �un��V l�rc�alols�. � DATE: OH�Z5 2O E NEC COMPLIANCE: COMPLV W ITH NEC AS APPLICABLE TO CONSTRUCTION AND INSTALLATION OF ELECTRICAL W IRING BO%ES AND FITTINGS. G. UL COMPLIANCE: COMPLV W ITH APPLICABLE REQUIREMENTS OF UL 50, UL 514SEPoE$ AND UL 886 PERTAINING TO ELECTRICAL BOXES AND FITTINGS. PROVIDE ELECTRICAL BOXES AND FITTINGS W HICH ARE UL-LISTED AND LABELED. H. NEMACOMPLIANCE: COMPLVWITHAPPLICABLEREQUIREMENTSOFNEMASTDS/PUBNO'5051, OS2 AND PUB 250 PERTAINING TO OUTLET AND DEVICE BOXES, COVERS AND BOX SUPPORTS. L FEDERALSPECIFlCATIONCOMPLIANCE:COMPLVWITHAPPLICABLEREQUIREMENTSOFFS W-C 586, "ELECTRICAL CAST METAL CONDUIT OURET BOXES, BODIES, AND ENTRANCE CAPS" PART2-PRODUCTS 21 METAL CONDUIT AND TUBING A. ELECTRICAL METALLIC TUBING AND FlTTINGS: ANSI C80.3. B. REXIBLE METAL CONDUIT: UL 1, ZINC-COATED STEEL. 22 METAL CLAD CABLE, TVPE MC A. THE MULT6CONDUCTOR METAL CLA� CABLE SHALL COMPLY W ITH UL 1569 "METAL CLA�, TVPE MC,` UL 83 "THERMOPLASTIC W SULATED W IRES AND CABLES" FEDERAL SPECIFICATION J-C-308 "WIRE AND CABLE," LOCAL AND NATIONAL ELECTRICAL CODES. B. THE METAL CLAD CABLE SHALL BE THHN INSULATION, COPPER CONDUCTORS IN SRES #12 THROUGH #8 AW G ONLV FOR CONTINUOUS OPERATION AT A MAXIMUM CONDUCTOR TEMPERATURE OF 90 DEGREE C DRV. C. THESE CABLES SHALL BEAR APPROPRIATE UNDERWRITERS LABORATORIES LABELS FOR METAL CLAD CABLE AND BE SUITABLE FOR USE AS BRANCH CIRCUITS IN BOTH EXPOSED AND CONCEALED WORK IN ACCORDANCE W ITH APPLICABLE SECTIONS OF THE NATIONAL ELECTRICAL COOE. D. AN INSULATED GROUNDING CONDUCTOR SRED IN ACCORDANCE WITH TABLE 5.3 UNDERWRITER'S STANDARD UL 1569 SHALL BE CABLED W ITH THE CIRCUIT CONOUCTORS AND SHALL BE IDENTIFIED IN COMPLIANCE WITH SECTION 29 0F UL 1569. THE GROUNDWG CONDUCTOR SHALL NOT BE SMALLER THAN SRE INDICATED IN NEC ARTIQE TABLE 250.122. E. A GALVANIZED STEEL OR A W MINUM ARMOR SHALL BE APPLIED OVER THE INNER CABLE ASSEMBLY W ITH A POSITIVE INTERLOCK IN COMPLIANCE W ITH SECTION 1� OF UL 1569. A PVC JACKET SHALL COMPLETELV COVER THE STEEL OR AW MINUM ARMOR W HEN INSTALLED IN THE SLAB. 2.3 CONDUIT BODIES AND FlTTINGS A. GENERAL: TVPES,SHAPES,ANDSIZESASREQUIREDTOSUITINOIVIDUALAPPLICATIONSANDNEC REQUIREMENTS. PROVIDE MATCHING GASKETED COVERS SECURED W ITH CORROSION-RESISTANT SCREWS. B. METALLICCONDUITANDTUBING:USEMETALLICCONDUITBODIES. USEBODIESWITHTHREADED HUBS FOR THREADED RACEWAVS. G EMT CONDUIT BODIES 1 INCH AND SMALLER: USE BODIES W ITH STEEL SET SCREW CONNECTORS AND COIIPLINGS FOR MTERIOR APPLICATIONS AND STEEL COMPRESSION GLAND CONNECTORS AND COUPLINGS FOR EXTERIOR APPLICATIONS. D. EMT CONDUIT BODIES 1 INCH AND LARGER: USE BODIES WITH STEEL SET SCREW CONNECTORS AND COUPLINGS FOR INTERIOR APPLICATIONS AND STEEL COMPRESSION GLAND CONNECTORS AND COUPLINGS FOR EXTERIOR APPLICATIONS. E. NONMETALLICCONDUITANDTUBING:USENONMETALLICCONDUITBODIESCONFORMINGTO UL514B. F. BUSHMGS: INSULATED TYPE, DESIGNED TO PREVENT ABRASION OF W IRES W ITHOUT IMPAIRING THE CONTINUITY OF THE CONDUIT GROUNDMG SYSTEM, FOR RIGID STEEL CONDUIT. IMC AND EMT, LARGER THAN'/<" SIZE. G. EXPANSIONFITTINGS'.EACHCONDUITTHATISBURIEDINORSECUREDTOTHEBUILDINGS CONSTRUCTION ON OPPOSITE SIDES OF A BWLDING EXPANSION JOINT AND EACH LONG RUN OF EXPOSED CONDUIT THAT MAV BE SUBJECT TO EXCESSIVE STRESSES SHALL BE PROVIDED W ITH AN EXPANSION RTTMG. EXPANSION FlTTINGS FOR RIGID STEEL WNDUIT SHALL BE HOT-DIPPED 6ALVANRED MALLEABLE IRON WITH FACTORV INSTALLED PACKIN6ANDA6ROUNDING RIN6. EXPANSION FITTINGS FOR RIGID NON-METALLIC CONDUIT SHALL BE OF THE SHORT TYPE IN RUNS 25'ORLESS,ANDTHELONGTVPEINRUN526'TO80'. THELONGTYPESHALLBEATWOPIECE BARREL AN� PISTON JOINT, PROVIDING 6" OF THE TOTAL MOVEMENT RANGE IN '/." THROUGH 6" CONDUIT SRES. THE SHORT TYPE SHALL BE A ONE PIECE, COUPLING W ITH O-RING, PROVI�ING T' OF TOTAL MOVEMENT RANGE IN'/<" TO 2" CON�UIT SIZES. 2.4 WIREWAVS A. GENERAL'. ELECTRICAL WIREWAVS SHALL BE OF TVPES, SIZES, AND NUMBER OF CHANNELS AS INDICATED. FlTTINGSANDACCESSOPoESINCLUDINGBUTNOTLIMITEDTOCOUPLINGS,OFFSETS, ELBOWS, EXPANSION JOINTS, ADAPTERS, HOLD-DOWN STRAPS, AND END CAPS SHALL MATCH AND MATEWITHWIREWAYASREpUIREDFORCOMPLETE5V5TEM. WHEREFEATURESARENOT INDICATED, SELECT TO FULFlLL W IRING REQl11REMENTS AND COMPLV WITH APPLICABLE PROVISIONS OF NEC. B. WIREWAV COVERS SHALL BE HINGED TVPE PROVIDE LOCKABLE COVER, IF W HEN INDICATED ON DRAWINGS. 2.SSURFACERACEWAVS A. GENERAL SIZESANOCHANNELSASINDICATEDON�R4WING5. PROVIDEFITTINGSTHATMATCH AND MATE W ITH RACEW AV. PROVIDE INTERNAL BARRIERS FOR AREAS W ITH POW ER AND COMMUNICATIONS SECTIONS. B. SURFACE METAL RACEWAV: CONSTRUCT OF TWO PIECE GALVANRED STEEL W ITH SNAP-ON COVERS, W ITH 9/321NCH MOUNTING SCREW KNOCKOUTS IN BASE APPRO%IMATELV 8 INCHES O.C. FINISH W ITH MANl1FACTURER'S STANDARD PRIME COATING SUITABLE FOR PAINTING. PROVI�E RACEWAVS OF TVPES SUITABLE FOR EACH APPLICATION RE�UIRED. SRES 13/4" H X a-314" W. G ACCESSORIES: 1. COUPLINGSFORJOININGRACEWAVSECTIONS. 2 WIRE CLIPS FOR CONDUCTORS. 3. BLANK END FITTINGS. 4. CIRCUIT BREAKER HOUSINGS FOR SINGLE POLE BREAKERS. 5. DEVICEBRACKETSFORSINGLEORTWOGANGDEVICES. 6. COMBINATIONRECEPTAQEANDTELEPHONEOUTLETCOVERS. ]. OUTLET BOXES WITH HUBS FOR CONDUIT CONNECTORS. 2b FABRICATED MATERIALS - BOMES A. OUTLET BOXES: PROVIDE GALVANIZED FLAT ROLLE� SHEET-STEEL OUTLET W IRWG BOXES, OF SHAPES, CUBIC INCH CAPAqTIES, AND SIZES (MINIMUM 41NCH S�UARE, 1% INCH DEEP�, INCLUDING BOX DEPTHS AS REQUIRED, SUITABLE FOR INSTALLATION AT RESPECTIVE LOCATIONS. CONSTRUCT OUTLET 60%ES W ITH MOUNTING HOLES, AND W ITH CABLE AND CONDUIT-SIZE KNOCKOUT OPENMGS IN BOTTOM AND SIDES. PROVI�E BOXES W ITH THREADED SCREW HOLES, W ITH CORROSION-RESISTANT COVER AND GROUNDMG SCREW S FOR FASTENMG SURFACE AND DEVICE TVPE BOX COVERS, AND FOR EQUIPMENT TVPE GROUNDING. 1. OUTLETBOXACCESSORIES: PROVIDEOUTLETBOXACCESSORIESASREQUIREDFOREACH INSTALLATION,INCWDINGBOXSUPPORTS,MOUNTINGEARSANDBRACKETS, WALLBOARD HANGERS, BOX EXTENSION RINGS, FIXTURE STUDS, CABLE CLAMPS AND METAL STRAPS FOR SUPPORTING OUTLET BOXES, WHICH ARE COMPATBLE W ITH OURET BOXES BEING USED TO FULRLLINSTALLATIONREQUIREMENTSFOR INDIVIDUALWIRINGSITUATIONS. CHOICEOF ACCESSORIES IS INSTALLER'S CODE-COMPLIANCE OPTION. B. DEVICE BOXES: PROVIDE GALVANIZED COATED FLAT ROLLED SHEET-STEEL NON-GANGABLE DEVICE BOXES, OF SHAPES, CUBIC INCH CAPACITIES, AND SIZES (MINIMUM 41NCH S�UARE, 1% WCHES DEEP), WCLUOING BOX DEPTHS AS INDICATED, SUITABLE FOR INSTALLATION AT RESPECTNE LOCATIONS. CONSTRUCT DEVICE BOXES FOR FLUSH MOUNTING W ITH MOUNTING HOLES, AND W ITH COND W LSIZE KNOCKOUT OPENINGS IN BOTTOM AND EN�S, AND W ITH THREADED SCREW HOLES W END PLATES FOR FASTENING DEVICES. PROVI�E CONDUIT CONNECTORS AND CORROSION-RESISTANT SCREW S FOR EQUIPMENT TYPE GROUNDING. 7.DEVICE BOXACCESSORIES: PROVIDEDEVICEBOXACCESSORIESASREQUIRE�FOREACHINSTALLATION, INCWOING MOUNTING BRACKETS, DEVICE BOX EXTENSIONS, SW ITCH BOX Sl1PPORTS, PLASTER EARS, ANO PLASTER EARS, AND PLASTERBOARD E%PANDABLE GRIP FASTENERS, WHICH ARE COMPATIBLE WITH DEVICE BOXES BEING UTILIZED TO FULFILL INSTALLATION RE�UIREMENTS FOR INDIVIDUAL W IRING SITUATIONS. CHOICE OF ACCESSORIES IS INSTALLER'S CODE-COMPLIANCE OPTION. C. JUNCTION AND PULL BOXES'. PROVIDE GALVANIZED CODE-GAUGE SHEET STEEL JUNCTION ANO PULL BO%ES, WITH SCREW-ON COVERS; OF TVPES, SHAPES AND SIZES, TO SUIT EACH RESPECTIVE LOCATION AND INSTALLATION; W ITH WELDED SEAMS AN� E�UIPPED W ITH STAINLESS STEEL NUTS, BOLTS, SCREWS, AN� WASHERS. PULL BOXES WSTALLEo M FlNISHE� SPACES MUST BE FLUSH MOUNTEO CABMETS PROVIDEO W ITH TRIM, HINGE� DOOR AND FW SH LATCH AND LOCK TO MATCH F W SH MOUNTED PANELBOARD TRIM. �. Bl15HING5,KNOCKOUTCLOSURESANDLOCKNUTS: PROVIDECORROSION-RESISTANTBO% KNOCKOUT CLOSURES, CONDUIT LOCKNUTS AND MALLEABLE IRON CONDUIT BUSHINGS, OFFSET CONNECTORS, OF TVPES AND SIZES. TO SUIT RESPECTNE W STALLATION REQUIREMENTS AND APPLICATIONS. iv_v��aa�semumi 3.1 W IRING METHOD A. INDOORS: USETHEFOLLOWINGWIRINGMETHODS: L EXPOSED: ELECTRICALMETALLICTUBING. 2. CONCEALED: ELECTRICALMETALLICTUBING. 3, CONCEALED�. METALCLADCABLEWILLBEALLOWEDASFlNALBRANCHWIRINGOFRECEPTACLE AND LIGHT FIXTURES MC IS NOT ALLOW ED FOR CONNECTIONS TO MECHANICAL EpUIPMENT. MAkIMUM CONDUCTOR SIZE IN MC CABLE #8 AW G. 4. CONNECTION TO VIBRATING EQUIPMENT WCLUDING TRANSFORMERS, PNEUMATIC OR ELECTRICALSOLENOI�,ANDMOTOR-OPERATE�EQUIPMENT: FLEXIBLEMETALCONDUIT. 5. CONNECTIONTOVIBRATINGEQUIPMENTINMOIST/HUMIDORCORROSIVEATMOSPHERE INCLUDING PNEUMATIC OR ELECTRIC SOLENOID, AND MOTOR-OPERATED EQUIPMENT. LIpUID-TIGHT FLEXIBLE METAL CONDUIT. 6. WITHINCONCRETESLABS:PVCCOATEDMCCABLE,ORRIGIDNON-METALLICCONDUIT. PVC COATEDMCCABLEISNOTALLOWEDFORHOMERl1N5. HOMERUNSSHALLBEINCONDUIT. MAXIMUM SRES AND LOCATIONS AS APPROVE� BV THE STRUCTURAL ENGMEER. 1. RACEWAV MOUNTED TO UNDERSIDE OF METALCORRUGATED SHEET ROOF DECKING SHALL BE RIGID METAL CONDUIT OR INTERMEDIATE METAL CONDUIT. 3 2 INSTALLATION OF RACEWAVS A. GENERAL�.INSTALLELECTRICALRACEWAVSINACCORDANCEWITHMANUFACTURERS'WRITTEN INSTALLATION INSTRUCTIONS, APPLICABLE REQUIREMENTS OF NEC, AND AS FOLLOW S. B. CONCEAL CONDUIT AND EMT, UNLESS INDICATED OTHERW ISE, W ITHIN FINISHED W ALL, CEILINGS, ANDFLOORS. KEEPRACEWAVSATLEAST6INCHESAWAVFROMPAR4LLELRUNSOFFWESAND STEAM OR HOT WATER PIPES. INSTALL RACEWAVS LEVEL AND Sal1ARE AND AT PROPER ELEVATIONS. G ELEVATIONOFRACEWAV:WHEREPOSSIBLE,INSTALLHORIZONTALRACEWAVRUNSABOVEWATER AND STEAM PIPING. D. COMPLETE INSTALLATION OF ELECTRICAL RACEWAVS BEFORE STARTING INSTALLATION OF CONDUCTORS WITHIN RACEWAVS. E PROVIDESUPPORTSFORRACEWAVSASSPECIFlEDELSEWHEREINDIVISION26ANDIN ACCORDANCE W ITH NEC AND LOCAL AUTHORITIES SEISMIC RE�UIREMENTS. F. PREVENT FOREIGN MATTER FROM ENTERING RACEWAVS BY USING TEMPORARY CLOSURE PROTECTION. G. PROTECT STUB-UPS FROM OAMAGE W HERE CONDUITS RISE FROM FLOOR SLABS. ARRANGE SO CURVED PORTION OF BENDS IS NOT VISIBLE ABOVE THE FlNISHED SLAB. ALL ELBOW PENETRATION THROUGH THE SLAB SHALL BE PVC COATED RIGID METALLIC CONDUIT ELLS. H. MAKE BENDS AND OFFSETS 50 THE INSIDE DIAMETER IS NOT EFFECTIVELV RE�UCED. UNLE55 OTHERW ISE IN�ICATED, KEEP THE LEGS OF A BEND IN THE SAME PLANE AND THE STRAIGHT LEGS OF OFFSETS PARALLEL. I. USERACEWAVFlTTINGSTHATAREOFTYPESCOMPATIBLEWITHTHEASSOCIATEDRACEWAVAND SUITABLEFORTHEUSEANDLOCATION. FORINTERMEDIATESTEELCONDUIT,USETHREADEDRIGID STEELCONDUITFITTINGSEXCEPTASOTHERWISEIN�ICATE�. J.RUNCONCEALEDR4CEWAVSWITH A MINIMl1M OF BENDS IN THE SHORTEST PRACTICAL DISTANCE CONSIDERING THE TVPE OF BUILOING CONSTRUCTION AND OBSTRUCTIONS EXCEPT AS OTHERWISE INDICATED. K. RACEWAVS EMBEDDED IN SLABS SHALL ONLV BE PERMITTEO W ITH THE STRICT W RITTEN APPROVALOFTHESTRUCTURALENGINEERANDARCHITECT. FORBIODINGPURPOSE,CONDUIT SHALL NOT BE PERMITTED IN SLAB. L. INSTALL EXPOSE� RACEWAVS PARALLEL AND PERPENDICULAR TO NEARBV SURFACES OR STRUCTURAL MEMBERS AND FOLLOW THE SURFACE CONTOURS AS MUCH AS PRACTICAL. ALL EXPOSED CONDUIT RUNS SHALL BE APPROVED BV THE ARCHITECT PRIOR TO INSTALLING. M. ALL EXPOSED CONDUITS IN PUBLIC AREAS SHALL BE PAINTED TO MATCH SURROUNDING WALLS. VERIFV E%ACTCOLOR WITH THEARCHITECT. PAINTING SPEQFIE� HEREIN SHALL BE PROVIDED BV OTHERS. N. RUN EXPOSED, PARALLEL, OR BANKED RACEWAYS TOGETHER. MAKE BEN�S IN PARALLEL OR BANKED RUNS FROM THE SAME CENTER LME SO THAT THE BENDS ARE PARALLEL FACTORV ELBOWS MAV BE USEO IN BANKED RUNS ONLY WHERE THEY CAN BE MSTALLED PARALLEL. THIS REpUIRES THAT THERE BE A CHANGE IN THE PLANE OF THE RUN SUCH AS FROM WALL TO CEILING AND THAT THE RACEWAVS BE OF THE SAME SIZE IN OTHER CASES, PROVIDE FlELD BENDS FOR PARALLEL RACEWAVS. ALL EXPOSED CONDUIT ROUTING SHALL BE APPROVED BV THE ARCHITECT PRIOR TO INSTALLING. O. JOIN R4CEWAVS WITH FITTINGS DESIGNEO AND APPROVED FOR THE PURPOSE AND MAKE JOINTS TIGHT. WHERE JOINTS CANNOT BE MADE TIGHT, USE BONDING JUMPERS TO PROVIDE ELECTRICAL CONTINUITVOFTHERACEWAVSYSTEM. MAKERACEWAVTERMINATIONSTIGHT. WHERE TERMINATIONS ARE SUBJECT TO VIBRATION, USE BONDIN6 BUSHINGS OR W EDGES TO ASSURE ELECTRICAL CONTINUITV. WHERE SUBJECT TO VIBRATION OR DAMPNESS, USE INSULATING BUSHMGSTOPROTECTCONDUCTORS. USEE%PANSIONFITTINGSATBUILDINGEXPANSIONJOINTS. P. TIGHTEN SET SCREWS OF THREADLESS FITTINGS WITH SUITABLE TOOL. �. TERMINATIONS: WHERERACEWAVSARETERMINATEDWITHLOCKNUTSANDBUSHMGS,ALIGNTHE RACEWAV TO ENTER SQUARELV AND INSTALL THE LOCKNUTS W ITH DISHED PART AGA W ST THE BOX. WHERETERMINATIONSCANNOTBEMADESECUREWITHONELOCKNUT,USETWOLOCKNUTS, ONE INSIDE AND ONE OUTSIDE OF THE BOX. ALL CONDUIT CONNECTIONS TO JUNCTION BOXES SHALL HAVEINSULATEDBUSHINGS. R. WHERE TERMINATING IN THREADED HUBS, SCREW THE RACEWAV OR RTTING TIGHT INTO THE HUB 50 THE END BEARS AGAINST THE W IRE PROTECTION SHOULDER. WHERE CHASE NIPPLES ARE USED, ALIGN THE RACEWAV SO THE COUPLING IS SQUARE TO THE BOX, AND TIGHTEN THE CHASE NIPPLE SO NO THREADS ARE EXPOSEO. S. INSTALL PULL W IRES IN EMPTY RACEWAVS. USE N0. 14 AW G ZINGCOATED STEEL OR MONOFILAMENT PLASTIC LINE HAVING NOT LE55 THAN 200-LB TENSILE STRENGTH. LEAVE NO LE55 THAN 12 INCHES OF SLACK AT EACH END OF THE PULL W IRE. T. TELEPHONE ANO SIGNAL SVSTEM RACEW AVS IN ADDITION TO THE ABOVE REpUIREMENTS, RACEWAVS 2-INCHES AND SMALLER, SHALL HAVE A MAXIMUM LENGTH OF 750 FEET W ITH A MAXIMUMOFTW0908ENDSOREQUIVALENT. WSTALLPULLORJUNCTIONBOXESWHERE NECESSARV TO COMPLV W ITH THESE REQUIREMENTS. ll. WSTALL RACEWAV SEALING FITTINGS IN ACCORDANCE W ITH THE MANUFACTURER'S WRITTEN WSTRUCTIONS LOCATE FITTINGS AT SUITABLE, APPROVED, ACCESSIBLE LOCATIONS AND FlLL THEM W ITH UL-LISTED SEALING COMPOUND. FOR CONCEALED RACEWAVS, INSTALL EACH FITTWG IN A RUSH STEEL BOX W ITH A BLANK COVER PLATE HAVIN6 A FlNISH SIMILAR TO THAT OF A�JACENTPLATESORSURFACES. WSTALLRACEWAVSEALINGFITTINGSATTHEFOLLOWING POINTS AND ELSEW HERE AS INDICATED'. 1. W HERE CONDUITS PASS FROM WARM LOCATIONS TO COLD LOCATIONS, SUCH AS THE BOUNDARIESOFREFRIGERATEDSPACES,AIR-CONDITIONEOSPACESANDWALK-IN COOLERS. 2. WHERE RE�UIRED BV THE NEC. V. STUB-UP CONNECTIONS: EXTEND CONDUITS THROUGH CONCRETE FLOOR FOR CONNECTION TO FREESTANDING EQUIPMENT W ITH AN ADJUSTABLE TOP OR COUPLING THREA�ED INSIDE FOR PWGS AND SET FWSH W ITH THE FINISHEO FLOOR. E%TEND CONDUCTORS TO EQUIPMENT W ITH RIGID STEEL CONDUIT, FLEXIBLE METAL CONDUIT MAV BE USED 61NCHES ABOVE THE FLOOR. W HERE EQUIPMENT CONNECTIONS ARE NOT MADE UNDER THIS CONTRACT, INSTALL SCREW DRIVER-OPERATE� THREA�E� F W SH P W GS F W SH W ITH FLOOR. W. FLEXIBLE CONNECTION'. IISE LENGTH (MAxIMUM OF 6 FT.) OF FLEXIBLE CONDUIT FOR RECESSED AND SEMI-RECESSED LIGHTING FlXTURES, FOR EQUIPMENT SUBJECT TO VIBRATION, NOISE TRANSMISSION,ORMOVEMENT;ANDPoRALLMOTORS. USELIQUID-TIGHTREXIBLECONOUITIN W ET LOCATIONS. INSTALL SEPARATE EQUIPMENT GROUNDING CONDUCTOR ACRO55 REXIBLE CONNECTIONS. X. INSTALL NONFERROUS CONDUIT OR TUBING FOR qRCUITS OPERATING ABOVE 60 HZ. Y. PVC EXTERNALLY COATED RIGID STEEL CONDUIT: USE ONLV FITTINGS APPROVED FOR USE W ITH THAT MATERIAL. PATCH ALL NICKS AND SCRAPES IN PVC COATING AFTER INSTALLING CONDUIT. Z. GROUNDING'. INSTALLASEPARATEGREENEQUIPMENTGROUNDINGCONDUCTORINALL RACEWAYS FROM THE PANELBOARDIJUNCTION BOX SUPPLVING THE RACEWAV TO THE RECEPTACLE OR EQUIPMENT GROUND TERMINALS. CONDUITS W ILL NOT BE PERMITTED AS A GROUNDCONDUCTOR. 3.3 WSTALLATION OF ELECTRICAL BOXES AND FlTTIN6S A. GENERAL WSTALL ELECTRICAL BOXES ANO FITTINGS IN ACCORDANCE W ITH MANUFACTURER'S W RITTEN INSTRUCTIONS, APPLICABLE REpUIREMENTS OF NEC AND NECA'S "STANDARD OF INSTALLATION," AN� IN ACCORDANCE W ITH RECOGNRE� INDUSTRV PRACTICES TO FULFILL PROJECTREQUIREMENTS. B. COORDINATE INSTALLATION OF ELECTRICAL BOXES AND FlTTINGS WITH WIRE/CABLE, WIRING DEVICES, AND RACEWAV INSTALLATION WORK. C. PROVIDE RAINTIGHT "IN USE" OUTLETS FOR INTERIOR AND E%TERIOR LOCATIONS E%POSED TO W EATHER OR MOISTURE. D. PROVIOE KNOCKOUT CLOSURES TO CAP UNUSED KNOCKOUT HOLES W HERE BLANKS HAVE BEEN REMOVED. E. INSTALL ELECTRICAL BOXES IN THOSE LOCATIONS W HICH ENSURE READV ACCESSIBILITV TO ENCLOSED ELECTRICAL W IRING. F. INSTALLING BOXES BACK-TO-BACK IN WALLS SHALL NOT BE PERMITTED. PROVIDE NO LESS THAN 12 WCHES (150 MM) OF SEPARATION. G. POSITION RECESSED OUTLET BOXES ACCURATELV TO ALLOW FOR SURFACE FINISH THICKNESS. H. AVOI� USING ROUNO 60%ES WHERE CONDl11T MIIST ENTER BOX THROUGH SI�E OF BOX, W HICH WOULD RESULT IN DIFFIWLT AND INSECURE CONNECTIONS WHEN FASTENEo W ITH LOCKNUT OR BUSHING ON ROUNDED SURFACES. L FASTEN ELECTRICAL BOXES FlRMLV AND RIGIDLV TO SUBSTRATES, OR STRUCTURAL SURFACES TO W HICH ATTACHED, OR SOLIOLV EMBEDOED ELECTRICAL BOXES IN WNCRETE OR MASONRY. J. PROVIDE ELECTRICAL CONNECTIONS FOR INSTALLED BOXES. K EXTERIOR JUNCTION OR PULL BOXES SHALL BE MOUMED FLUSH W ITH GRADE, UNLESS NOTED OTHERW ISE OR INDICATED TO BE ABOVE GROUND ON THE DRAW WGS. BOXES SHALL BE SURROUNDED ON ALL SIDES W ITH 6 INCHES MINIMUM OF CONCRETE. TOP OF CONCRETE SHALL FWSH W ITH GRADE. SEAL ALL CON�UIT ENTRIES INTO BOX W ITH DUCT SEAL TO PREVENT ENTRANCE OF MOISTURE, AFTER CONDUCTORS ARE INSTALLED. L TAP AND SPLICES, WHERE PERMITTED BV THESE SPECIFICATIONS W ITHM EXTERIOR JUNCTION BOXES, SHALL BE PERFORMED W ITH AN ENCAPSULATING WATERTI6HT SPLICE OR TAP KIT WHICH WSULATES AND MOISTURE SEALS THE CONNECTION. KIT SHALL WNSIST OF THE APPROPRIATE SIZE ANO TYPE MOLD, ENCAPSULATING RESIN ANO ENO SEALING TAPE. M. SUBSEQUENT TO INSTALLATION OF BOXES, PROTECT BO%ES FROM CONSTRUCTION DEBRIS AND DAMAGE. 3 4 GROUN�ING A. UPON COMPLETION OF INSTALLATION W ORK PROPERLV GROUND ELECTRICAL 80XE5 AND DEMONSTRATE COMPLIANCE W ITH REQUIREMENTS. 3.5 ADJUSTING AND QEANING A. UPON COMPLETION OF INSTALLATION OF R4CEWAVS, INSPECT INTERIORS OF RQCEWAVS; CLEAR ALL BLOCKAGES AND REMOVE BURRS. DIRT, AND CONSTRUCTION DEBRIS. END OF SECTION 260533 SECTION 260553 - IDENTIRCATION PART1-GENERAL 1.iRELATEODOCUMENTS A. �RAWINGSANDGENERALPROVISIONSOFCONTRACT,INCWDINGGENERALANDSUPPLEMENTARV WNDITIONS AN DIVISION 1 SPEqFICATION SECTIONS, APPLY TO THIS SECTION. B. RWUIREMENTSOFTHEFOLLOWINGDIVISION26SECTIONSAPPLVTOTHISSECTION: 1. "ELECTRICAL REQUIREMENTS." L2SUMMARV A. THISSECTIONINCWDESIDENTIFICATIONOFELECTRICALMATERIALS.EQUIPMENT,AND INSTALLATIONS. IT INCLUDES REQUIREMENTS FOR ELECTRICAL IDENTIFlCATION COMPONENTS INCLUDING BUT NOT LIMITED TO THE FOLLOW ING: 1. IDENTIFICATION LABELING FOR RACEWAYS, CABLES, AND CONDUCTORS. 2 OPERATIONAL INSTRIICTION SIGNS. 3. WARNINGANDCAUTIONSIGNS. 4. EQUIPMENTLABELSANDSIGNS. B. RELATED SECTIONS'. THE FOLLOW ING SECTIONS CONTAIN REQUIREMENTS THAT RELATE TO THIS SECTION; 1. OIVISION 9 SECTION "PAINTING" FOR RELATED IDENTIFICATION REpUIREMENTS. 2. DIVISION26SECTION"WIRESANDCABLES"FORRE�UIREMENTSFORCOLORCODINGOF CONDUCTORS FOR PHASE IDENTIFlCATION. C. REFERTOOTHERDIVISION265ECTIONSFORADDITIONALSPEQFICELECTRICALIDENTIFICATION ASSOCIATED WITH SPECIFIC ITEMS. 1 3 SIIBMITTALS A. GENERAL SUBMITTHEFOLLOWINGINACCORDANCEWITHCONDITIONSOFCONTRACTAND DIVISION 1 SPECIFICATION SECTIONS. B. PRO�UCT DATA FOR EACH TVPE OF PRODUCT SPEQFIED. G SCHEDULE OF I�ENTIFICATION NOMENCLATURE TO BE USED FOR IDENTIFICATION SIGNS AND LABELS D. SAMPLES OF ENGRAVED. PLASTIC LAMINATE TO BE USED ON SWITCHGEAR, SW ITCHBOARD$ DISCONNECT SW ITCHES AND PANELBOAR�S. 1.4 pUALITV ASSURANCE A. ELECTRICAL COMPONENT STANDARO: COMPONENTS AND INSTALLATION SHALL COMPLV W ITH NFPA ]0 "NATIONAL ELECTRICAL CODE" B. ANSICOMPLIANCE COMPLVWITHREQUIREMENTSOFANSISTANDARDA13.1,"SCHEMEFORTHE IDENTIFICATION OF PIPING SVSTEMS," W ITH REGARD TO TVPE AND SIZE OF LETTERING FOR RACEWAY AND CABLE LABELS. V_1:i{'�J:I�LIRNltl 2.1 ELECTRICAL IDENTIFICATION PRODUCTS A. COLORED ADHESNE MARKING TAPE FOR RACEW AV$ W IRES, AND CABLES: SELFADHESIVE VINVL TAPE NOT LESS THAN 3 MIL THICK BY 1 MCH TO 2 WCHES IN W IDTH. B. WIRE/CABLEDESIGNATIONTAPEMARKERS: VINVLORVINVL-0LOTH,SELF-ADHESIVE,WRAP AROIIND, CABLE/CONDUCTOR MARKERS W ITH PREPRINTED NUMBERS ANO LETTERS. G ENGRAVED, PLASTIC-LAMINATED LABELS. SIGNS, AND INSTRUCTION PLATES: ENGRAVWG STOCK MELAMWE PLASTIC LAMINATE, 1/i6-INCH MINIMUM THICK FOR SIGN UP TO 20 SQUARE WCHES, OR 8 INCHES IN LENGTH; 1/8-WCH THICK FOR LARGER SIZES ENGRAVED LEGEND IN BLACK LETTERS ON W HITE FACE FOR NORMAL POW ER AND RED LETTERS ON WHITE FACE FOR EMERGENCV AND STANDBV POW ER. PLASTIC LAMINATE SHALL BE PUNCHED FOR MECHANICAL FASTENERS. D. BAKED-ENAMEL WARNINGAND CAUTION SIGNS FOR INTERIOR USE: PREPRINTED ALUMINUM SIGN$ PUNCHED FOR FASTENERS, W ITH COLORS. LEGENO, AND SIZE APPROPRIATE TO THE LOCATION. E. FASTENERS FOR PLASTIGLAMINATE� AND METAL SIGNS: SELF-TAPPING STAMLESS STEEL SCREWS OR NUMBER 10132 STAMLE55 STEEL MACHINE SCREWS W ITH NlITS AND FLAT ANO LOCK WASHERS. E CABLETIES FUNGUS-WERT,SELFEXTINGUISHING,ONEPIECE,SELFLOCKINGNVLONCABLETIES, 0.18-INCH MINIMUM W IDTH, 50-LB MINIMUM TENSILE STREN6TH, AND SUITABLE FOR A TEMPERATURE RANGE FROM MINUS SOF TO 350F. PROVIDE TIES IN SPECIFlED COLORS W HEN USED FOR COLOR CODING. G ELECTRONICLABELS: SELFADHESIVE,3/i61NCHIN�USTRIALLABELBLACKONCLEARFOR NORMAL CIRCUITS AN� RED ON QEAR FOR EMERGENCV/STANDBV CIRCUITS. ACCEPTABLE MANUFACTURERS WCLU�E THE FOLLOWING: 1. KROV 2 BROTHER PART3-EXECUTION 3.1 INSTALLATION A. LETTERINGANDGRAPHICS: COORDINATENAMES,ABBREVIATIONS,COLORS,AN�OTHER DESIGNATIONS USED IN ELECTRICAL I�ENTIFICATION WORK W ITH CORRESPONDING DESIGNATIONS SPECIFIED OR INOICATED. INSTALL NUMBERS, LETTERWG, AND COLOftS AS APPROVED IN SUBMITTALS AND AS REQUIRED BY CODE. B. INSTALL IDENTIFlCATION DEVICES IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND REQUIREMENTS OF NEC. C. SEQl1ENCE OF WORK: WHERE IDENTIFICATION IS TO BE APPLIED TO SURFACES THAT REQl11RE FINISH, INSTALL IDENTIFICATION AFTER COMPLETION OF FINISH WORK. 32 CONDUIT IDENTIRCATION A. IDENTIFV JUNCTION, PULL, AND CONNECTION BOXES: CODE-REOUIRED CAUTION SIGN FOR BOXES SHALL BE PRESSURE-SENSITNE, SELF-ADHESIVE LABEL INDICATING SVSTEM VOLTAGE IN BLACK, PREPRINTED ON ORANGE BACKGROl1ND. INSTALL ON OUTSIDE OF BOM COVER. ALSO LABEL BOX COVERSWITHIDENTITYOFCONTAWEOCIRCUITS. USEPRESSURESENSITNEPLASTICLABELSAT EXPOSED LOCATIONS AND SIMILAR LABELS AT CONCEALED BOXES. 6. IDENTIFV R4CEWAYS OF CERTAIN SVSTEMS W ITH COLOR BANDING: BAND EXPOSED OR ACCESSIBLERACEWAVSOFTHEFOLLOWINGSVSTEMSFORI�ENTIFICATION. BANDSSHALLBE PAINTED W ITH COLORS INDICATED BELOW. MAKE EACH COLOR BAND 21NCHE5 W IDE, COMPLETELV ENCIRCLING CONDUIT, AND PLACE ADJACENT BANDS OF TW O-COLOR MARKINGS IN CONTACT. SIDE BV SIDE. INSTALL BAN�S AT CHANGES IN DIRECTION, AT PENETRATIONS OF WALLS AND FLOORS, ANDAT40-FOOTMAXIMUMINTERVALSINSTRAIGHTRUNS. APPLVTHEFOLLOWINGCOLORS: 1. FIRE ALARM SVSTEMS: RED. 2 FlRESUPPRESSIONSUPERVISORVANDCONTROLSVSTEM: REDANDVELLOW. 3. MECHANICALANDELECTRICALSUPERVISORYSVSTEM: GREENANDBLUE. 4. TAG OR LABEL CONDUCTORS AS FOLLOWS: a. FUTURE CONNECTIONS'. CONDUCTORS INDICATED TO BE FOR FUTURE CONNECTION OR CONNECTION UNDER ANOTHER CONTRACT W ITH IDENTIFICATION INDICATING SOURCE AND INTENT. b. MULTIPLECIRCUITS: WHEREMULTIPLEBRANCHqRCUITSORCONTROLWIRMGOR COMMUNICATIONS/SIGNAL CONDUCTORS ARE PRESENT IN THE SAME BOX OR ENCLOSURE LABELEACHCONDUCTORORCABLE PROVIDELABELONEACHBOXINDICATINGSOURCE, VOLTAGE,CIRCUITNUMBER,ANDPHASEFORBRANCHCIRCUITWIRING. PHASEANDVOLTAGE OF BRANCH CIRCUIT W IRING MAV BE IN�ICATED BV MEAN OF CODE� COLOR OF CONDUCTOR INSULATION. FOR CONTROL AND COMMUNICATIONS/SIGNAL W IRING, USE COLOR COD W G OR W IREICABLE MARKING TAPE AT TERMINATIONS AND AT INTERMEDIATE LOCATIONS W HERE WNDUCTORS APPEAR IN W IRING BOXES, TROUGHS, AND CONTROL CABINETS. USE CONSISTENT LETTER/NUMBER CONDUCTOR DESIGNATIONS THROUGHOUT ON W IREICABLE MARKING TAPES. c. MATCH IDENTIFlCATION MARKINGS W ITH DESIGNATIONS USED IN PANELBOARDS SHOP DRAWINGS, CONTRACT DOCUMENTS, AND SIMILAR PREVIOUSLV ESTABLISHED IDENTIRCATION SCHEMES FOR THE FAGLITIES' ELECTRICAL INSTALLATIONS. C. INSTALL LABELS AT LOCATIONS INDICATEO AND AT LOCATIONS FOR BEST CONVENIENCE OF VIEW ING W ITHOUT INTERFERENCE W ITH OPERATION AND MAINTENANCE OF EQUIPMENT. D. CONDUCTOR COLOR CODING PROVIDE COLOR CODMG FOR SECONDARV SERVICE, FEEDER, AND BRANCH CIRCUIT CON�UCTORS THROUGHOUT THE PROJECT SECONDARV ELECTRICAL SYSTEM AS FOLLOWS: 208/120 VOLTS PHASE 480/277 VOLTS BLACK A BROWN RED B ORANGE BWE C VELLOW WHITE NEUTRAL GRAV GREEN GROUNO GREEN E. USE CONDUCTORS W ITH COLOR FACTORV-APPLIED THE ENTIRE LENGTH OF THE CONDUCTORS EXCEPTAS FOLLOWS: 7. THE FOLLOW ING FlELD-APPLIED COLOR-CODING METHODS MAV BE USED IN LIEU OF FACTORV-CODED W IRE FOR SIZES LARGER THAN N0. 10 AW G: a. APPLV COLORED, PRESSURE-SENSITNE PLASTIC TAP IN HALF-LAPPED TURNS FOR A OISTANCE OF 6 INCHES FROM TERMINAL POINTS AND IN BO%ES W HERE SPLICES OR TAPS ARE MAOE. APPLVTHELASTTWOLAPSOFTAPEWITHNOTENSIONTOPREVENTPOSSIBLEUNWINDING. USE 7-INCH-WIDETAPEIN COLORSASSPECIFlED. DONOTOBLITERATECABLE IDENTIFlCATION MARKINGSBVTAPING. TAPELOCATIONSMAVBEA�JUSTEDSLIGHTLYTOPREVENTSUCH OBLITERATION. b. W LIEU OF PRESSURE-SENSITIVE TAPE, COLORED CABLE TIES MAV BE USED FOR COLOR IDENTIFlCATION. APPLV THREE TIES OF SPECIFlED COLOR TO EACH W IRE AT EACH TERMINAL OR SPLICE POINT STARTING 31NCHES FROM THE TERMINAL AND SPACED 31NCHES APART. APPLV W ITH A SPECIAL TOOL OR PLIERS, TIGHTEN FOR SNUG FIT, AND CUT OFF EXCE55 LENGTH. 2 ALL GROUN�ED CONDUCTORS NO. 6 AW G AND SMALLER SHALL BE A FACTORV APPLIED COLOR ACROSS THE ENTIRE LENGTH OF CONDUCTORS. F. POWERqRCUITIDENTIFICATION: L SECURELV FASTEN W RAP-AROUNO MARKER BANDS TO CABLE$ FEEDERS, AND POW ER CIRCUITS IN PULL BOXES, JUNCTION BOXES, AND ELECTRICAL ROOMS. G. APPLV WARNMG, CAUTION, AND INSTRl1CTION SIGNS ANO STENCILS AS FOLLOW S: 1. MSTALL WARNING, CAUTION, OR INSTRUCT10N SIGNS W HERE REQUIRED BV NEC W HERE INDICATED, OR WHERE REASONABLV REQUIRED TO ASSURE SAFE OPERATION AND MAINTENANCE OF ELECTRICAL SVSTEMS ANO OF THE ITEMS TO W HICH THEV CONNECT. INSTALL EN6RAVED PLASTIGLAMINATED INSTRUCTION SIGNS WITH APPROVED LEGEND WHERE INSTRUCTIONS OR EXPLANATIONS ARE NEEDED FOR SVSTEM OR EQUIPMENT OPERATION. INSTALL BUTVRATE SIGNS W ITH METAL BACKING FOR OUTDOOR ITEMS. H. INSTALL WUIPMENT/SVSTEM qRCUIT/DEVICE IDENTIRCATION AS FOLLOWS: 1. APPLV ELECTRONIC L46EL ON THE INSIDE OF ALL RECEPTACLE AND SW ITCH PLATES. THE LABELS SHALL IOENTIFV QRCUIT ANO PANELBOARD. END OF SECTION 260553 SECTION 262126 - W IRING DEVICES PART1-GENERAL 1.iRELATED00CUMENTS A. DRAWINGSANDGENERALPROVISIONSOFCONTRACT,INCWDINGGENERALANDSUPPLEMENTARV CONDITIONS AND DIVISION 1 SPECIFICATION SECTIONS, APPLY TO THIS SECTION. B. REQUIREMENTSOFTHEFOLLOWINGDIVISION26SECTIONSAPPLVTOTHISSECTION. 125UMMARV A. THIS SECTION W CLUDES THE FOLLOW ING: 1. RECEPTACLES 2. PLUGS 3.PLUG CONNECTORS 4. WALLPLATES S.FLOORBOXES B. RELATED SECTIONS: THE FOLLOW ING SECTIONS CONTAIN REQUIREMENTS THAT RELATE TO THIS SECTION: 1. �NISION 26 SECTION "MOTOR DISCONNECTS AND FUSES" FOR DEVICES OTHER THAN SNAP SWITCHES AND PWG/RECEPTACLE SETS USED AS DISWNNECTS FOR MOTORS. 1.3 SUBMITTALS A. PRODl1CT DATA FOR EACH TVPE OF PROOUCT SPECIFIED. B. OCCUPANCVSENSORS 1. SUBMITALIGHTINGPLANQEARLVMARKEDBYMANUFACTURERIDENTIFVINGPRODUCTTYPE, LOCATIONS, ORIENTATION AND COVERAGE FOR EACH SENSOR. 2 SUBMITANVINTERCONNECTIONDIAGRAMSPERMAJORSUBSVSTEMSSHOWINGPROPERWIRING. 1 4 QUALITV ASSURANCE. A. REGULATORV REQUIREMENTS: COMPLY W ITH PROVISIONS OF THE FOLLOW ING CODES. L NFPA]0"NATIONALELECTRICALCODE" B. UL AND NEMA COMPLIANCE: PROVIOE W IRING DEVICES W HICH ARE LISTED AND L4BELED BV UL, FEDERAL SPEGFICATION AND COMPLV W ITH APPLICABLE UL AND NEMA STANDARDS. 155E�UENCEANDSCHEDULWG A. SCHEDULE INSTALLATION OF FINISH PLATES AFTER THE SURFACE UPON W HICH THEV ARE INSTALLED HAS RECENED FlNAL FINISH. IV_1:i�'SYi�LD[NFY if\�fll:il�[H�lyq[NY: A. GENERAL: PROVIDE W IRING DEVICES, IN TYPES, CHARACTERISTICS GRADES, COLOR$ AND ELECTRICAL RATINGS PoR APPLICATIONS INDICATED W HICH ARE UL LISTED AND W HICH COMPLY W ITH NEMA W D 1 AND OTHER APPLICABLE UL AND NEMA STANDARDS. B. COLOR OF DEVICES: COLOR OF ALL DEVICES SHALL BE COOROINATEO W ITH THE ARCHITECT AND OWNER, EXCEPT SPECIAL PURPOSE DEVICES SHALL BE BLACK, EMERGENCV POW ER SVSTEM DEVICES WHICH SHALL BE RED, CORROSION-RESISTANT DEVICES WHICH SHALL BE VELLOW, OR ISOLATED GROUND DEVICES WHICH SHALL BE ORANGE. G RECEPTACLES: AS SCHEDULED IN TABLE 1 IN PART 3 INDICATED HEREIN. COMPLV W ITH UL 498 AND NEMA W O 1 AND W D 6. D. RECEPTACLES, INDUSTRIAL HEAVV DUTV: PROVIDE PIN AND SLEEVE OESIGN RECEPTACLES CONFORMING TO UL 498. COMPLV WITH UL 1010 W HERE INSTALLED IN HAZARDOUS LOCATIONS. PROVIDE FEATURES INDICATED. E. WALL DIMMER: AS SCHEDULED IN TABLE 21N PART 31N�ICATED HEREIN. 1. OIMMERS INDICATED ON THE DR4WINGS TO SERVE LOW VOLTAGE LED LAMPS SHALL BE SPECIFICALLV R4TED FOR THE LOW VOLTAGE TRANSFORMER LOAO. DIMMER SHALL BE UL LISTED FOR USE W ITH LOW VOLTAGE FlXTURES. 2. DIMMERS INDICATED TO SERVE RUORESCENT LAMPS SHALL BE 12�V OR 2]1V, AS RWUIRED FOR QRCUIT SERVED, SOLID STATE TVPE FOR USE W ITH FLUORESCENT DIMMING BALLASTS. CONTROL SHALL BE SLIDE HANDLE AND DIMMER SHALL BE FOR SEMI-FWSH MOUNTING. 3. ALL OIMMERS SHALL BE OF THE SAME MANUFACTURER. FACEPLATE SHALL BE THE SAME COLOR AS DEVICE PLATES SPEqFlED. F ALL DEVICES SHALL BE PREMIUM SPECIFlCATION GRADE. L2 WIRINGDEVICEACCESSORIES A. WALLPLATES:SINGLEANDCOMBINATION,OFTVPES,SIZES,ANDWITHGANGINGANDCUTOUTSAS INDICATED. PROVIDE METAL SCREW S FOR SECURING PLATES TO DEVICES W ITH SCRE W HEADS COLORED TO MATCH RNISH OF PLATES. PROVIDE WALL PLATES WITH ENGRAVE� LEGEND WHERE INDICATED ON DRAWINGS. ENGRAVING SHALL 8E DONE BV THE DEVICE MANUFACTURER. ALL LETTERING SHALL BE 1/8-WCH HIGH AND SHALL BE BLACK FOR NORMAL POW ER SVSTEMS ANO REO FOREMERGENCVPOWERSVSTEMS. PROVIDEPLATESPOSSESSINGTHEFOLLOWINGAODITIONAL CONSTRUCTION FEATURES: 7. MATERIAL AND FlNISH: 0.�4 WCH THICK. TYPE 302 SATM RNISHED STAINLESS STEEL. PLATE SHALL BE HUBBELL "5" SERIES OR APPROVED EQUAL. B. FOR ALL DEVICES INSTALLED W HICH ARE E%POSED TO THE W EATHER, MOISTl1RE OR W HERE INDICATED ON THE DRAW WGS, DEVICE PLATES SHALL BE WEATHERPROOF. DEVICE PLATES SHALL BE CAST METALLIC TVPE W ITH GASKETING TO PREVENT ENTRANCE OF MOISTURE WHEN CLOSED. � � / ♦ 1 � INDUSTRIOUS COWORKING 880 W MONON GREEN BLVD CARMEL qTV, IN 460323 OWNERRENANi INDUSTRIOUS 215PARKAVES,4E1300 NEW YORK, NY 10003 ARCNI7ECTOFRECORD NORF 325 N LASALLE Si- SOIiE 500 CHICAGO. IL 60654 PEiER-DUBWC.ANORR-COM 312-0242400 MEFENG/NEER MEENGINEERS 29 WEST 38iH SiREEi, SiH FLOOR NEW YORK. NY 10018 CONiAQ: BRIAN SHASSIAN BRIANSHASSIAN@ME-ENGINEER$_COM JOHN HIGGINS JOHN.HIGGWS(�MEENGINEERS.COM �212J 44]-6]]0 PHONE LIGHi1NGDESIGNER REGENCY 9261 JOkDAN AVE CHAiSWORiH, GA 800-28d-2026 ISSUEDATES REV. DAiE DESCRIPiION 06/OS/2020 DD3 06/18/2020 CDvI 0]/06/2020 CDv2 0]/16/2020 PERMIT SEAL & SIGNANRE BY CHEGK ME ME ME ME ME ME ME ME PR0./ECTNAME CARMEL CITY- 880 MONON GREEN VROJECiNUMBER IND880MON DRAWINGTIiLE ELECTRICAL SPECS II SCALE 7/8„_ ��_�„ SHEETNUMBER E-021 oF