HomeMy WebLinkAboutFP000 Fire Protection LegendSPRINKLER LEGEND ( NOT ALL SVMBOLS LISTED BELOW ARE BEING USED IN THIS SET OF SPRWKLER DRAWINGS ) GENERAL SYMBOLS/ ABBR. GENERAL PIPING C SVM80L ABBR DESCRIPTION SVMBOL ABBR �ESCRIPTION SVMBOL SECTIONNQ (E) EXISTWGSPRMKLERPIPING �� F (LIGHT SOLID LINE) M _ _ _ EXISTINGSPRWKLERPIPING SECTION VIEW SHEET NO. (R) TO BE REMOVED (DASHED � LME) �� SHEETKEVNOTES SP SPRWKLERPIPING � — y POINTOFCONN.(CONN.NEWTO ST STANDPIPEPIPING l �-� POC EXISTWG) �I~ DR DRAIN — %"— PIPE SIZE � �� POD POINT OF DISCONNECTION ARROW IN�ICATES DIRECTION - OFFLOW �P RISE IN DIRECTION OF FLOW DN OROP IN DIRECTION OF FLOW DN OOWN AFF ABOVEFINISHEDFLOOR AFG ABOVEFINISHEDGRA�E TOP TOP OF PIPE (AFF) BOP BOT.OFPIPE(AFF) LE. INVERTELEVATION NTS NOTTOSCALE (E) EXISTING (R) REMOVE FD FLOORDRAIN O C. ON CENTER SPR. SPRINKLER SpFT SQUAREFEET TEMP TEMPERATURE MECHANICAUPLUMBING/ SPRINKLER/ELECTRICAL COORDINATION REQUIREMENTS FOR MECHANICAL PLUMBMG AND SPRINKLER W UIPMENT AS INDICATED ON THE DIVISION 21, 22, AND 23 DRAW INGS, THE DIVISION 21, 22 AND 23 CONTRACTORS SHALL COORDINATE W ITH DNISION 26 CONTRACTOR TO CONNECT ALL MECHANICAL AND P W MBING E�UIPMENT INDICATED ON THE MECHANICAL,PLUMBING ANDSPRWKLERORAWINGS. COOROINATE FOR COMPLETE W IRING, STARTERS. ANo oISCONNECTING MEANS FOR ALL MECHANICAL, P W MBING AND SPRINKLER E�UIPMENT. DCDA I DOUBLECHECKDETECTOR ASSEMBLV � � o�Ll� ��^ W TS SVMBOL ���J �I� I�I 4 rs � Ts � � C � � � � VALVES ,BBR DESCRIPTION DRAIN VALVE W/ HOSE END DV CONN. CHECK VALVE W/ INDICATION CV OFFLOWDIRECTION PRV PRESSURE REDUCING VALVE BFV BUTTERFLVVALVE BV BALLVALVE TPR TEMPERATUREIPRESSURE RELIEF VALVE VALVE IN RISER STRAWER WI BLOW-0FF & STR CAPPEDHOSE-END CONNECTION GV GATE VALVE OSBV OUTSIDESTEMANDVOKE VALVE wITH TAMPER SW ITCH FITTINGS ABBR DESCRIPTION EJ EXPANSIONJOINT U UNION FC FLEXIBLE PIPE CONNEQOR FS FLOWSWITCH PS PRESSURESWITCH TS TAMPERSWITCH PRESSURE GAUGE W/GAUGE P� COCK ELBOW UP ELBOW DOWN TEE UP TEE DOWN PIPE CAP OR PLUG CR CONCENTRIC REDUCER ER ECCENTRIC REDUCER SPRINKLER HEAD SCHEDULE REQ. DESCRIPTION MANUFACTURER MODELNO. K-FACTOR PRESSURE MEA# REMARKS (PSI) �UICKRESPONSESIDEWALL RELIABLE FiFR 5.6 ] 258-9&E NONE �UICK RESPONSE CONCEALED PEN�ANT RELIABLE GS-56 5.6 ] 258-93-E NONE �UICK RESPONSE PENDANT RELIABLE FiFR 5.6 ] 258-9&E NONE �UICK RESPONSE RECESSE� PENDANT RELIABLE FiFR 5.6 ] 258-93-E NONE �UICK RESPONSE UPRIGHT RELIABLE FiFR 5.6 ] 258-9&E NONE �UICK RESPONSE DRV HEADS RELIABLE F3qR 5.6 ] 258-9&E NONE RELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel r �u't��\i ��•r�fJilta/f �. � DATE: OH�Z5�2O SVMBOL �E �p 0 0 UO � • EC �o � 0 •IT � HT D , EC SPRINKLER HEADS ABBR �ESCRIPTION EXISTING HEAD TO REMAIN R EXISTINGHEA�TO BEREMOVE� U UPRIGHT UO UPRIGHTUNDEROBSTRUCT CONCEALEDPENDANT EC EXTENDEDCOVERAGE CONCEALED PENDANT HEAD p DRV CONCEALED PENDANT HEA� D DRV UPRIGHT HEAD IT INTERMEDIATE TEMPERATURE RATED HEAD HT HIGHTEMPER4TURER4TED HEAD SIDEWALL HEAD EXTENDEDCOVERA6E SIDEWALL HEAD FIRE PUMP ABBR. SYMBOL ABBR �ESCRIPTION FP FIRE PUMP JP JOCKEVPUMP FIRE PROTECTION ASSEMBLIES SYMBOL ABBR DESCRIPTION y SIA RRE DEPARTMENT (SIAMESE) WNNECTION � FCVA FLOOR CONTROL VALVE ASSEMBLV FHC FHC FIREHOSECABINET FHV FHV FIRE HOSE VALVE GENERAL FIRE PROTECTION CONTRACT REQUIREMENTS : L FlRE PROTECTION DESIGN IS BASED ON A PERFORMANCE SPECIFlCATION. 2. CONTRACTOR SHALL PROVIDE COMPLETE DESIGN ANO ENGW EERING OF ALL PROPOSED FIRE PROTECTION WORK AN� SHALL ACT AS THE ENGINEER OF RECORO FOR THE PROJECT. 3. CONTRACTOR SHALL PROVIDE COMPLETE HVDRAULICALLV DESIGN W ET PIPE SPRINKLER SYSTEMS FOR THE AREAS INDICATED. CONTRACTOR SHALL COORDINATE PROCURING ANV (HVDRANT) ROW TESTS RE�UIRED IN OR�ER TO COMPLETE HVDRAULIC CALCULATIONS. 4. SPRINKLER HEAO L4VOUTS WILL BE SUBJECT TO ARCHITECT APPROVAL. AT MINIMUM ALL HEADS SHALL BE LOCATED IN THE CENTER OF CEILING TILES ANO W LINE W ITH OTHER CEILING FEATURES SUCH AS LIGHTS, DIFFUSERS, SPRWKLERS, CEILING MOUNT DEVICES, ETC. SPRINKLER SPECIFICATIONS 1. GENERAL A. ALL SPRINKLER WORK MUST COMPLV W ITH THE IN�IANA STATE BUIL�ING CODE, NFPA CODES LATEST EDITION, AND THE APPLICABLE INSURANCE AGENCV GUIDELINES. B. THIS CONTRACTOR SHALL OBTAIN ALL RE�UIRED PERMITS FROM LOCAL AUTHORITIES. C. ALL MATERIAL SHALL BE UL, NFPA LISTED OR APPROVED. D. CONTRACTOR SHALL FIELD VERIFV LOCATION OF THE EXISTING SPRINKLER PIPING, VALVES, TANKS, ETC. E. SPRINKLERPIPINGSHALLBETESTEDANDAPPROVEDBEFORECONNECTINGTOTHEEXISTINGSVSTEM. F. SCOPE IS BASED ON A PERFORMANCE SPECIFICATION. REFER TO DRAW INGS. G. VERIFVALLGOVERNINGOIMENSIONSATTHEBUILDING. H. PROVIDE WORKMANSHIP OF HIGHEST GRADE: WSTALL ALL PIPING AND SPRINKLER HEADS IN CONFORMANCE W ITH MANUFACTURER'S RECOMMENOATIONS AND REQl11REMENTS OF NFPA-13, LOCAL FIRE DEPARTMENT, OW NER'S INSURANCE UNDERW RITERS AND BUILDING CODE. I. PROVIDE ONE VEAR GUARAMEE AGAINST DEFECTNE WORKMANSHIP AND MATERIALS. J. SPRINKLERCLASSIFICATION: LIGHTHAZARDOCCUPANCY. K. ORAW INGS SHOULD BE SIGNED AND SEALED BV A LICENSED PROFESSIONAL ENGMEER. L. REFERTOTHETOTHEHVDRAULICSPRWKLERSIZINGCRITERIAANDASSOCIATEDNOTESANDTHESPRINKLERNOTESONTHE FLOOR PLANS FOR ADDITIONAL REQUIREMENTS. 2. SCOPE OF WORK A. PROVIDEALLREQUIREDLABOR,MATERIAL$EQUIPMENT,PERMITS,CERTIFlCATES,INSPECTION,TESTINGANDOTHERSERVICES NECESSARV OR REpUIRED FOR COMPLETE SAFE INSTALLATION OF WORK IN FULL WNFORMANCE WITH REQUIREMENTS OF ALL AUTHORITIES HAVING JURISDICTION: ALL AS INDICATED ON �RAW INGS ANDIOR HEREIN SPECIFIED. B. COORDINATEALLSPRINKLERSHUTDOWNSWITHTHEBUILDINGOWNERANDPROVIDEALLREQUIREDLABORANDMATERIALTO PROTECT THE AREAS W ITHOUT SPRINKLER COVERAGE FROM RRE DURING SPRINKLER SHUT DOW NS. 3. SHOPDRAWINGS A. FURNISHSHOPDR4WINGSOFALLEQUIPMENT,PIPING,VALVES,HEADS,SIAMESECONNECTIONSANDRELATEOACCESSORIES. 4. TESTS A. TEST SPRINKLER PIPWG AT 50 PSI ABOVE MAXIMUM STATIC PRESSURE BUT NOT LESS THAN AT 200 PSI FOR TVJO HOURS AND IN ACCORDANCE WITH ALL REQUIREMENTS OF NFPA AND LOCAL CODE. 5. MATERIAL A. GENERAL TVPE AND SIZE OF MATERIALS SHALL BE APPROVEO BY LOCAL FIRE DEPARTMENT, NFPA AND OW NER'S WSURANCE UNDERWRITERS. SVSTEMASINSTALLEOSHALLMEETREQUIREMENTSOFLOCALAUTHORITIESHAVINGJURISDICTIONAND OW NER'S INSURANCE UNDERW RITERS AND RECENE APPROVAL OF SAME BEFORE FINAL PAVMENT. 6. HANGERSANDSUPPORTS A. SUPPORT HORIZONTAL PIPING AT LEAST EVERY 10 FEET AND NO BRANCHES 2 FEET OR LONGER W ITHOUT SUPPORT. B. 2 INCH PIPE AND SMALLER: AUTO-GRIP; & V2 INCH PIPE AND LARGER'. CLEVIS TVPE. ]. INSERTS A EXPANSION SHIELD TVPE SUITABLE FOR USE W ITH EXISTING CONCRETE STRUCTURE. e. BEAM CLAMPS A. APPROVED GCLAMPS W ITH LOCKNUT. 9. ESCUTCHEONS A. PROVIDE EXPOSED PIPES W ITH APPROVED TVPE CAST BRASS OR CAST IRON ESCUTCHEONS, CHROME PLATE�. 10. PIPE MATERIAL A. STANDARD W EIGHT SCHEDULES 40 STEEL PIPE, SEAMLESS OR W ELDED MILD STEEL ASTM A420, A435, OR A 53. B. LIGHT W EIGHT SCHEDULE 10 SHALL NOT BE PERMITTED. 11. FITTINGS A. CAST IRON THREADED, STANOARD W EIGHT, ANSI B 164. B. CAST IRON FLANGED FITTINGS AND FLANGES: STANDARD WEIGHT, ANSI B463. G GROOVED END MALLEABLE IRON FlTTMGS AND COUPLINGS W ITH APPROPRIATED PRESSURE RATING, SIMILAR TO VICTAULIC: SUBJECT TO SPECIAL APPROVAL BV ENG W EER. D. REDUCERSANDINCREASERS:OFTAPEREDTVPE;NOBlISHINGSPERMITTEDEXCEPTWHERESPECIFICALLVAPPROVEDBY ENGINEER. E. CONNECTIONS TO EXISTWG PIPWG MAV BE MALLEABLE IRON OR DUCTILE IRON MECHANICAL T-OUTLETS SIMILAR TO VICTAULIC STYLE 920. F. THISCONTRACTORSHALLCOOR�INATEDISCONNECTIONOFSPRINKLERSVSTEMAN�RECHARGINGOFSPRWKLERSYSTEMWITH THE BUILDING MANAGEMENT. 12. COORDINATIONDRAWINGS A. PREPARE COMPOSITE WORKING DRAW INGS AND SECTIONS AT A SUITABLE SCALE NOT LESS THAN 3I8" = 1'-0" CLEARLV SHOW ING HOW THE WORK IS TO BE INSTALLED IN RELATION TO THE WORK OF OTHER TRADES. IF THE INSTALLATION IS MADE BEFORE COORDINATING W ITH OTHER TRADES, MAKE ALL NECESSARV CHANGES IN THE W ORK W ITHOUT EXTRA CHARGE TO THE OW NER. 6. ALL COORDINATION SCOPE SHALL NOT BE THE RESPONSIBILITV OF THE BUILOING OW NER. C. BEFORE SUBMITTING SHOP DRAWINGS FOR SLEEVES, PIPING AND DUCTWORK, THE HEATING, VENTILATWG ANDAIR CONDITION WG CONTRACTOR SHALL PREPARE A COMBMED 3/8" = 1'-0" SCALE SHOP DRAW MG FOR PIPING AND DUCTVJORK INDICATING LOCATION OF PIPING AND DUCTW ORK W ITH DIMENSIONS. A TRANSPARENT COPV OF THESE SHOP DRAW INGS SHALL BE GNEN TO THE ELECTRICAL CONTRACTOR. D. THE ELECTRICAL CONTR4CTOR SHALL INDICATE THE LOCATION OF ALL LIGHTING FIXTURES ANO CONDUIT RUNS ON THESE SHOP oRAW INGS. THE ELECTRICAL CONTRACTOR SHALL GNE THE TRANSPARENT COPV OF THESE SHOP DRAW WGS, W ITH LIGHTING RXTURES ANo CONDUIT RUNS INDICATED TO THE PLUMB WG AND SPRINKLER CONTRACTOR AS REQUIRED. THE PLUMBING AND SPRINKLERCONTRACTORSHALLINDICATEHISNEWAND EXISTINGPIPINGTOREMAINONTHESESHOPDRAWINGS EACH CONTRACTOR SHALL KEEP EACH TRANSPARENT COPV NOT MORE THAN THREE (3) WORKING DAVS. E. THEHEATING.VENTILATINGANDAIRCONDITIONINGCONTRACTORSHALLARRANGEACOORDINATIONMEETINGWITHPWMBING ANO SPRINKLER ANO ELECTRICAL CONTRACTORS UNDER THE SUPERVISION OF THE GENERAL CONTRACTOR. AFTER COORDINATION.EACHCONTRACTORSHALLSIGNTHETRANSPARENTCOPV. THEHEATING,VENTILATINGANOAIRCONDITIONING CONTRACTOR SHALL SUBMIT DRAWINGS TO THE ARCHITECT FOR REVIEW AND HE SHALL CALL ANV CONFLICTS THAT COULO NOT BE RESOLVED M THE COORDINATION MEETINGS, AN�/OR DEVIATION FROM ORIGINAL DESIGN, TO THE ARCHITECT'S ATTENTION. AFTER RECEIVING W RITTEN REVIEW FROM THE ARCHITECL EACH CONTRACTOR SHALL PREPARE THE SHOP DRAW INGS AS REQUIRED IN THE SPECIFlCATIONS. HYDRAULIC SPRINKLER SIZING CRITERIA SHALL 8E AS REQUIRED BV THE AUTHORITIES HAVING JURISDICTION BUT SHALL NOT BE SMALLER THAN THE FOLLOW WG: 1. OCCUPANCV CLASSIFICATION = LIGHT HAZARD 2. DENSITY=0.70GPM/SQUAREFEET 3. AREA OF APPLICATION = 1500 SQUARE FEET 4. COVERAGE/SPRWKLER=2255pUAREFEETIHEADMAXIMUMFORLIGHTHAZAR� THE CONTRACTOR SHALL BE RESPONSIBLE TO PREPARE HV�RAULIC CALCULATIONS AND OBTAIN APPROVAL FROM ALL AUTHORITIES HAVING JURISDICTION OVER THE SPRINKLER W ORK, INCLUDMG THE BUILDWG DEPARTMENT, THE OW NERS INSURANCE CO., OBTAIN AGENCV APPROVALS FOR HVDRAULICS PRIOR TO INSTALLATION OF NEW WORK. HVDR4ULIC CALCl1LATIONS SHALL BE SIGNED AND SEALE� BV A LICENSED PROFESSIONAL ENGMEERRETAWEDBVTHESPRINKLERCONTRACTOR. CONTRACTORSHALLCOORDINATE PROCURING ANV (HVDRANT) FLOW TESTS RE�UIRED IN ORDER TO COMPLETE HYDRAULIC CALCULATIONS. SPRMKLER CONTRACTOR SHALL PREPARE ALL DOCUMENTS REQUIREO FOR ANV SUBSEQUENT FlLING W ITH AUTHORITIES HAVING JURISDICTION 1�1 INDUSTRIOUS COWORKING 880 W MONON GREEN BLVD CARMEL qTV, IN 460323 OWNERRENANi INDUSTRIOUS 215PARKAVES,4E1300 NEW YORK, NY 10003 ARCNI7ECTOFRECORD NORF 325 N LASALLE Si- SOIiE 500 CHICAGO. IL 60654 PEiER-DUBWC.ANORR-COM 312-0242400 MEFENG/NEER MEENGINEERS 29 WEST 38iH SiREEi, SiH FLOOR NEW YORK. NY 10018 CONiAQ: BRIAN SHASSIAN BRIANSHASSIAN@ME-ENGINEER$_COM JOHN HIGGINS JOHN.HIGGWS(�MEENGINEERS.COM �212J 44]-6]]0 PHONE LIGHi1NGDESIGNER REGENCY 9261 JOkDAN AVE CHAiSwORiH, GA 800-28d-2026 ISSUEDATES REV. DAiE DESCRIPiION 06/OS/2020 DD3 06/18/2020 CDvI 0]/06/2020 CDv2 0]/16/2020 PERMIT SEAL & SIGNATURE BY CHEGK ME ME ME ME ME ME ME ME PR0./ECTNAME CARMEL CITY- 880 MONON GREEN VROJECiNUMBER IND880MON DRAWINGTIiLE FIRE PROTECTION LEGEND SCALE 7/8„_ ��_�„ SHEETNUMBER FP-000 oF