HomeMy WebLinkAboutM000 Mechanical Legend1�1
INDUSTRIOUS
COWORKING
880 W MONON GREEN BLVD
CARMEL qTV, IN 460323
GENERALSYMBOLS/ABBR.
SVMBOL I ABBR DESCRIPTION
� SECTION N0.
SECTION VIEW SHEET NO.
F DETAIL DESIGNATION
M1
�F_i EQUIPMENTDESIGNATION
1
1�-� SHEETKEVNOTES
� �
�POINTOFCONN.(CONN.
POC NEWTOEXISTING)
�� POD POINTOFDISCONNECTION
ARROW INDICATES DIRECTION
OF FLOW
q ��� �X) AIRDEVICECALL
OR OIIT. TVP.OF (X)
OGFM (X) DEVICES.
(f2) REMOVE
(E) EXISTING
DN DOWN
AFF ABOVE FINISHED FLOOR
AFG ABOVEFINISHEDGRADE
TOP TOP OF PIPE (AFF)
NTS NOTTOSCALE
AMB AMBIENT
BTUH BRITISHTHERMALUNITPER
HOUR
CFH CUBIC FEET PER HOUR
CV CONSTANTVOLUME
tlB DECIBEL
DB DRV-BULB
DDC DIRECTDIGITALCONTROL
DER DERECTION
DIA DIAMETER
DWG DRAWING
EER ENERGVEFFlQENTRATIO
ENT ENTERING
°F DEGREEFAHRENHEIT
FPI RNS PER INCH
FPM FEETPER MINUTE
FTWC FEETWATERCOLUMN
GAL GALLON
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
INWC WCHWATERCOLUMN
LBS POUNDS
LVG LEAVING
MAX MAXIMUM
MBH THOUSANDBTUH
MIN MINIMUM
NC NOISE CRITERIA
O.G ON CENTER
PRESSURE DROPI
P'�' DIFFERENTIAL
PRE55 PRESSURE
PSIG POUNDS PER S�UARE INCH
GAUGE
PWL SOUNDPOWERLEVEL
Qr ounNnry
RH RELATIVE HUMIDITV
SPECS SPECIFICATIONS
SQ SQUARE
SQ FT SQUARE FEET
SS STAINLESS STEEL
TVP TVPICAL
UON UNLESSOTHERWISENOTED
VEL. VELOQTV
VTR VENTTHROUGHROOF
WB WET-BULB
W� WITH
WIO WITHOUT
RELEA5E0 FOR CONSTRUCTION
Suhjec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
r
�un��V l�rc�alols�.
�
DATE: OH�Z5�2O
GENERAL ELECTRICAL ABBR.
SVMBOL ABBR OESCRIPTION
BHP BRAKEHORSEPOWER
FLA FULL LOAO AMP
HP HORSEPOWER
HZ HERTZ
KW KILOWATTS
MCA MINIMIIMCIRCUITAMP
MCC MOTORCONTROLCENTER
MFS MAXIMUM FUSE SIZE
MOCP MAX.OVERCURRENT
PROTECTION
RLA RUNNINGLOADAMP
RPM REVOLUTION PER MINUTE
EQUIPMENT ABBREVIATIONS
SVMBOL ABBR OESCRIPTION
AF AFTER FILTER
AH AIR HANDLING UNIT
B BOILER
TVPE gg BASEBOARD
ENGT
CAV CONSTANTAIRVOLUME
CC COOLINGCOIL
CH CHILLER
DOG
FOG DIESELOILGAUGE
DOP DIESEL OIL PUMP
FOP
EF EXHAUSTFAN
FC FAN COIL UNIT
FF FINAL FlLTER
FT FLASH TANK
FS FLOOR SINK
HC HEATINGCOIL
Hll HUMI�IFIERSECTION
MUA MAKE-UPAIRl1NIT
P� �R��ILTER
�l
RF RETURN FAN
SF SUPPLVFAN
ST SOUNDTRAP
VAV VARIABLEAIRVOLUME
VFD VARIABLEFREpUENCVDRIVE
WF WATERFlLTRATION
MISC. ABBREVIATIONS
SVMBOL ABBR DESCRIPTION
AL ALUMINUM
COP COEFFIQENTOFPERFORMANCE
EFF EFFICIENCV
ISOL. ISOLATOR
MTL METAL
OPNG OPENING
REF REFERENCE
SHT SHEET
MECHANIC
( NOT ALL SVMBOLS LISTED BELOW ARE BEMG USE
HVAC DUCTWORK/DAMPERS
SYMBOL DESCRIPTION
DOUBLE SINGLE
�C � RETURN DUCT UP
) U
I—'�' J I�I SUPPLVDUCTUP
I—� � LJ EXHAUST Dl1CT UP
�i C �.,� SUPPLVOUCTDOWN
I�� � ��
I i �� RETURNDUCTDOWN
i �
I i C I.,� EXHAUSTDUCTDOWN
� ) i
� � ROUNDDIICTDOWN
�C i�I�ll� ROUND DUCT UP
) �W��
I i � DUCTDROP
� ��
� � TRANSITION-RECT. TO
RECT. OR ROUND TO
ROUND
� � TRANSITION-RECT. TO
ROUND
�� VANED ELBOW
�l
� CAPPE�DUCTWORK
�EXISTINGDUCTVJORK
NOCHANGE
(LIGHT SOLID LINE)
___� EXISTINGOUCTWORKTO
�---� BEREMOVED(DASHED
LINE)
DUCT WI INTERNAL
(��� ����%�j LINWGIL=1"THICK
2L= 2" THICK
� � CONICALTAP
� � GONIGALSPIN-MFlTTING
W/ MANUAL VO W ME
OAMPER
SVMBOL ABBR DESCRIPTION
� � FD FIRE�AMPER
�� SD SMOKEDAMPER
H—�
� � FIRE SMOKE DPMPER.
FSD CONTROLLED BV DUCT
SMOKEDETECTOR
�y-y � MD MOTORREDDAMPER
Fy 4
MANUALVOLUME
VD DAMPERW/LOCKING
� QUADRANT
COD CABLEOPERATED
MANUALOAMPER
�� BD BACKDR4FTDAMPER
IH+� �`y�
AL LEGEND
l IN THIS SET OF MECHANICAL DRAW INGS )
HVAC SYMBOLS/ ABBR.
SVMBOL ABBR DESCRIPTION
��� SUPPLV OIFFUSER-
CD 4_WA�THROW
��� SUPPLV DIFFUSER-
CD 3-WAVTHROW
��� SUPPLV DIFFUSER-
�� 2-WAVTHROW
SUPPLV DIFFUSER-
�� �� 1-WAVTHROW
� LD SUPPLVSLOTDIFFUSER
� CRIRG RETURN AIR GRILLE
�/ LOW PRESSURE FLEXIBLE
DUCT
� AP CEILINGACCESSPANEL
�= HUMI�IFlEft
REXIBLE DUCT CONNECTION
q LENGTH �X� AIR DEVICE CALL OUT.
^/CFM TVP. OF (X) DEVICES.
UC ti_
DIL ti_
Ll�
�
UP
DN
SVMBOL
�
i
�T (el
�
is
�
"O
Hs
Ps
co
co
E%TERIOR WALL LOWER
`N� (UNDERARCH.SECTION)
UNDERCUTDOOR(UNDER
UC qRCH.SECTION)
DIL DOORLOUVER(UNDERARCH.
SECTION)
UD LOWERDOORFULLHEIGHT.
(UNDER ARCH. SECTION)
RETURN/ EXHAUST AIR FLOW
SVMBOL
SUPPLV AIR FLOW SVMBOL
RISE IN DIRECTION OF
AIRFLOW
DROP IN DIRECTION OF
AIRFLOW
BOD BOTTOM OF DUCT (AFF)
TOD TOP OF DUCT (AFF)
CFM CUBIC FEET PER MINUTE
DP DISCHARGE PLENUM
EA EXHAUSTAIR
ESP EXTERNALSTATIC PRESSURE
MA MAKEUPAIR
OA OUTSIDEAIR
RA RETURNAIR
SA SUPPLVAIR
SCFM STANDARDAIRCUBICFEET
PER MINUTE
S.P. STATICPRESSURE
TG TRANSFERGRILLE
TSP TOTAL STATIC PRESSURE
WMS WIREMESHSCREEN
CONTROLS
ABBR DESCRIPTION
A CONTROLAIR(PNEUMATIC)
FS FLOWSWITCH
PS PRESSURESWITCH
(E)T EXISTINGTHERMOSTAT
T NEW THERMOSTAT
SPACE TEMPERATURE SENSOR
DUCTMOUNTEDSMOKE
DETECTOR
SPACE HUMIDISTAT
SPACE HUMIDITV SENSOR
SPACEPRESSURESENSOR
CARBON DIOXIDE SENSOR
CARBON MONOXIDE SENSOR
PIPING
SVMBOL ABBR DESCRIPTION
(E) EXISTWG PIPING
(LIGHT SOLID LINE)
(R) EXISTING PIPING TO BE
REMOVED (DASHED LINE)
HWS HEATINGWATERSUPPLV
HWR HEATINGWATERRETURN
HTVJS HIGHTEMP.HOTWATER
SUPPLV
HNJR HIGHTEMP.HOTWATER
RETURN
CHS CHILLEDWATERSUPPLV
CHR CHILLED WATER RETURN
CWS CONDENSERWATERSUPPLV
CWR CONDENSERWATERRETURN
RS REFRIGERANTSUCTION
RL REFRIGERANTLI�UID
RHG REFRIGERANT HOT GAS
DR EQUIPMENTDRAIN
D INDIRECT�RAIN
V VENT
—2"HWS— PIPESIZE/PIPETVPE
MISC. PIPING
SVMBOL ABBR DESCRIPTION
BD BOILERBLOWDOWN
BF BOILERFEED
BO BLOW OFF
CF CHEMICALFEEDER
STEAM
SVMBOL ABBR DESCRIPTION
LPS LOWPRESSURESTEAM
SUPPLV
� f MPS MEDIUMPRESSURESTEAM
SUPPLV
�5' ff HPS HIGH PRESSURE STEAM
SUPPLV
LPR LOW PRESSURESTEAM
CONDENSATE RETURN
MPR MEDIUM PRESSURE STEAM
CONDENSATE RETURN
HPR HIGH PRESSURE STEAM
CONDENSATE RETURN
PR PUMPED CONDENSATE
RETURN
� STEAM TRAP
�� PRV PRESSURE REDUCING VALVE
CRU CONDENSATE RETURN UNIT
LBSMR pOUNDS PER HOUR
GENERATOR
SVMBOL ABBR DESCRIPTION
GEN EX GENERATOR ENGINE E%HAUST
DOS DIESELOILSUPPLV
FOS
DOR DIESEL OIL RETURN
FOR
JWS JACKETWATERSUPPLY
JWR JACKETWATERRETURN
CAC C CHARGED AIR COOLING
COLD CIRCUIT
CACH CHARGEDAIRCOOLING
HOT QRCUIT
DR EQUIPMENTDRAIN
VALVES
SVMBOL ABBR DESCRIPTION
�� DV DRAIN VALVE W/ HOSE END
CONN.
�� CV CHECKVALVEWIINDICATION
OF FLOW DIRECTION
� PRV PRESSURE REDUqNG VALVE
W
SV SOLENOID VALVE
FC pUTO FLOW CONTROLVALVE
I iI FCV W�TESTPORTS
�i
� CS,BV CIRCUITSETTERORBALANCING
VALVE
� GLOBE VALVE (STRAIGHT
GLV pq1TERN)
� GLOBE VALVE (ANGLE
GLV pq77ERN)
�� � BFV BUTTERFLV VALVE
� BV BALLVALVE
� TW AUTOMATICTEMP.
CONTROL VALVE, 2-W AV
� TCV AUTOMATIC TEMP.
CONTROL VALVE, 3-WAV
� � TPR TEMPERATURH
PRESSURE RELIEF VALVE
� VALVE IN RISER
� STRAMERW/BLOW-OFFB
STR CAPPE� HOSE-END
CONNECTION
� GV GATEVALVE
�� OS&V OUTSIDE STEM AND VOKE
,�[, _ BALL VALVE WI HOSE
�.x-� CONNECTION
�`� PV PLUG VALVE
FITTINGS
SYMBOL ABBR DESCRIPTION
� PgT PRESSURE/TEMPER4TURE
PORTTAPS
Y CR CONCENTRIC REDUCER
� ER ECCENTRIC RE�UCER
���J EJ EXPANSION JOINT
� � ll UNION
� THERMOMETER
WITHERMOWELL
� AV AIR VENT
���� FC FLE%IBLEPIPECONNECTOR
, �/ PG PRESSURE GAUGE WIGAUGE
TCOCK
� ELBOW UP
C ELBOW DOWN
V TEE 11P
� TEEDOWN
� PIPE CAP OR PLUG
� TPR TEMPERATURE/PRESSURE
RELIEF VALVE
STRAINER W/ BLOW-OFF 8
� STR CAPPEO HOSE-ENO
CONNECTION
MECHANICAL/PLUMBING/
SPRINKLER/ELECTRICAL
COORDINATION REQUIREMENTS
FOR MECHANICAL AND PW MBING EQUIPMENT AS
INDICATED ON THE DIVISION 2L 22, AND 23 DRAW INGS.
THE DIVISION 21, 22 AND 23 CONTRACTORS SHALL
COORDINATE W ITH DIVISION 26 CONTRACTOR TO
CONNECT ALL MECHANICAL ANO PWMBING
EQUIPMENT INDICATED ON THE MECHANICALAND
PWMBING �RAWINGS. COORDINATE FORCOMPLETE
W IRING, STARTERS. AND �ISCONNECTING MEANS FOR
ALL MECHANICAL AND PLUMBING EQUIPMENT.
OWNERRENANi
INDUSTRIOUS
215PARKAVES,4E1300
NEW YORK, NY 10003
ARCNI7ECTOFRECORD
NORF
325 N LASALLE Si- SOIiE 500
CHICAGO. IL 60654
PEiER-DUBWC.ANORR-COM
312-0242400
MEFENG/NEER
MEENGINEERS
29 WEST 38iH SiREEi, SiH FLOOR
NEW YORK. NY 10018
CONiAQ: BRIAN SHASSIAN
BRIANSHASSIAN@ME-ENGINEER$_COM
JOHN HIGGINS
JOHN.HIGGWS(�MEENGINEERS.COM
�212J 44]-6]]0 PHONE
LIGHi1NGDESIGNER
REGENCY
9261 JOkDAN AVE
CHAiSwORiH, GA
800-28d-2026
ISSUEDATES
REV. DAiE DESCRIPiION
06/OS/2020 DD3
06/18/2020 CDvI
0]/06/2020 CDv2
0]/16/2020 PERMIT
SEAL & SIGNATURE
BY CHEGK
ME ME
ME ME
ME ME
ME ME
PR0./ECTNAME
CARMEL CITY- 880 MONON GREEN
VROJECiNUMBER
IND880MON
DRAWING TITLE
MECHANICALLEGEND
SCALE
7/8„_ ��_�„
SHEETNUMBER
M-000
oF