Loading...
HomeMy WebLinkAboutA110 Communication Plan�� `-:'� I . �7-PEBSON OFFICE 175 y HUDDLE 48 176 P � c � � LIBPPPY � 210 � 3-PENSON OFFICE 178 NIC. �p p� EMf1Y LOUNGE 209 II 8-PEPSON II OFFICE I 227 �tt � C0� 226 s o Eq �� n��� ,,,...,,. FEC 5-PEFSON OFFIGE 174 6-PEHSON OFFICE 173 6-PERSON OFFICE 172 �v 8-PEPSON OFFICE 1fi1 PflINT N.IL. D � HIIDDLE 98 no � 2-PEPSON OFFICE 162 4-PEPSON OFFICE 191 2-PENSON 2-PERSON OFFICE OFFICE 192 190 d � � 2�-r�w � OFFICE 2-PERSON 193 OFFICE 189 � B-PERSON OFFICE 177 5-PERSON OFFICE 179 7-PERSON OFFICE 180 6-PERSON OFFICE 181 5-PEHSON OFFICE 182 2-PERSON I 1NN I OFFIGE 194 4-PEflSON OFFICE 183 M�F CESSIBLE 195 PHONE � 187 PflINT E-0 E�43 E-25 E�A E2] AREA E-20 E.43 � 205 CONF 72 6P �� ( a p a 166 w I E-O6 weu ss �ao• 165 �'60" E�0]D f � E-04 a � +60" ,. +38" +1 d GF G I 5 4� ESTAOOM CONF 96 BP AVo 167 w +38"G 164 � +60" �+60" 0 O +6�' d o +38"GFl 5'-81/4'• t38" GFl MEN'S PESTHOOM �}38"GFI 163 p.pEASON Z-PERSON \� �� o168E OFFICE 169 1� 8-PEfl50N OFFICE 160 6a169EN �� 6-aP'SIBEN POWER & SIGNAL PLAN ��, ,�a.._,.-0.. N.I.C. SIGNAL & DATA PLAN KEY NOTES 1.1 GC TO COORDINATE ALL CORE POWER LOCATIONS PRIOR TO CORING 1.2 WALL MOUNTED POWER/DATA/AV OUTLETS FOR WALL MOUNTED DISPLAY. REFER TO AV DRAWINGS FOR OUTLET LOCATIONS AT RACKAND COORDINATE WITH AVINSTALLER 1.3 ELECTRIC STUB UP TO BE CONCEALED IN MILLWORK TO PROVIDE POWER FOR ISLAND 1.4 LOCATION OF MAIN LIGHTING CONTROLS FOR ASSOCIATED FLOOR 1.5 220V CLOCK OUTLET IS REQUIRED. 30A AMP. GC TO COORDINATE WITH MILLWORKER FOR LOCATION OF INLINE WATER FILTER, TO BE PLACED IN BASE CABINET AND MOUNTED VERTICALLY WITH A BRACKET. PROVIDE PLUG - GC TO INSTALL W/PLUG 1.6 PROVIDE 208V FOR DISHWASHER RELEA5E0 FOR CONSTRIlCTION Suhjec��o compliance with allregula�ions 04 S�a�e antl Local Codes City of Carmel r � �\ �un��\i ��.r�fJi�tM�`�_ � DATE: OH�Z5�2O OFFICE 199 1-PE SO OffICE 198 1-PEHSON @_pEPSON 3 OFFICE OFFlCE � 202 1W � �PEPSON 3-PERSON OFFICE OffICE � 203 196 � 1-PERSON OFFICE 204 IXECUiIVE SUITE 229 7-PEPSON OffICE 155 5o184EN �I SOF85SdN �¢p+e +9 $+9' �� � LOUNGE � 2W +9"� +9"� OFFICE 153 e-PEASON OFFICE 154 � � 7-PEHSON OFFICE 156 �IXTURE SCHEDULE ITEM MANUF. TVPE MODEL LOCATION COLOR 10R2GANGWALLPLATE WTRONDESIGNER SCREWLESSWALLPLATE THROUGHOUT WHITE 3 GANG WALL PLATE LUTRON DESIGNER, 3-GANG SCREWLESS WALL PHONE ROOM BLACK ADORNE PLATE,BLACKINK-DIM. SWITCH+SWITCH+ OUTLET(1X)AWP3GGR4, �ix� noPoasa�nnz, ��x7 ASPD1532M4,(1%) 28UTTONWIRELESS WTRON,PICO PJ2-28-GBL-L01W/PICO- OFFICE BLACK,MOUNTED CONTROL WIRELESS MOUNT4-BL-CPNS]33 ON DOORFRAME 1GANG,10R2PORT LEGRAND,CLASSIC WP3401/WP3402 THROUGHOUT BLACK;WHITEIN KEVSTONE WALLPLATE AMENITV ONLV MULTISERVICEPOKETHRU LEGRAND RC4MULTISERVICEPOKE- CAFHLOUNGE BLACK THRU DEVICE MULTISERVICEPOKETHRU LEGRAND EVOWTIONSATC2PBK CONFERENCE& BLACK HUDDLE CLOCKOUTLEf 220V CAFE@ WHITE COFFEE MACHWE 7-PEASON OFFICE 106 LIBAAAY O � 225 OFFICE ��ll V/ D � 9-PEBBON HODDLE BEC_AV 7-PERSON 137 138 HUD�LE PEC_AV OFFICE 1� �'� E 139 �� 140 � � +50>50"+50" +50"+50"+50 �k khM,�n M,h�o . � FEC IXECU�NE SURE 136 4-PEfl50N OFFICE 104 OFFICE 135 2-PEfl50N OFFICE &PEPSON �43 OFFICE 1GA � 1-PEHSON 2-PERSON ss OFFICE OffIGE 134 � 1M � 3-PERSON Z-PEPSON OFFICE 0 45CE 133 ` 7�q O �PEN I I�W- 1-PEH� 8-PERSON . OFFICE 18fi _ � � CONF 96 BP � 101 EQ Ep � �, 0 1 tfi0'+60�,� � � � � i T&1 i Te-1 � 1/4' TB-1 � m� �O TB-1 � U D�D J i9� +�" �' +9� � +6� � � � Ep � EQ CAF,FAOUNGE L�J 00 NOTIN CONTRACT � - � � � 2-PENSON OFFICE 126 fi-PEPSON OFFICE 125 E29 E29 MAIL POOM � � �� �� 2-PEPSON OFFICE 1� � 2-PERSON OFfICE 149 3-PEflSON OffICE 150 2-PERSON OFFlCE 152 IXECIRNE smre im 4-PERSON OFfICE 108 4� OFFlCE 109 6-PERSON OFFIGE 110 5-PERSON OFFIGE 111 5-PERSON OFFIGE 112 5-PERSON OFFICE 113 D � HUDD'L� 60 TB-2 TB2 � ACCESSIBLE � PHONE 117 � D 7-PERSON fi-PEflSON 5-PEPSON OFFICE OFF�CE �123E 122 4-PEASON OFFICE 114 G�[N 4-PEPSON OFFICE 119 8-PEFSON 50FFICEN 0 ZI�CE 121 � � a 'OWER & SIGNAL LEGEND ANNOTATIONS AND DEFINITIONS DATA PLAN SHEET NOTES $ LIGHTSWITCH FURNISH: SUPPLVANDDELNERTOPROJECTSITEREADVFOR �, SEEGSHEETSERIESFORADDITIONALNOTESANDABBREVIATIONS p UNLOA�ING,UNPACKING&INSTALLATION. 2 SEEENGWEERINGDRAWINGSFORADDITIONALWFORMATION. $ pIMMER SWITCH INSTALC OPERATIONS ON PROJECT SITE INCL. UNLOA�ING, TEMP. 3. G.C. TO COORDINATE ALL FINAL FLOOR CORE LOCATIONS WITH FURNITURE VENDOR, OWNER AND ARCHITECT PRIOR TO START OF WORK. ALL FLOOR AN� WALL CORING SHALL BE # WALLMOUNTEDQUADOUTLET STORING,UNPACKING,INSTALLING,ASSEMBLING,PLACING, SCHEDULEDDURINGOFFHOURSUNLESSOTHERWISEALLOWEDBVOWNER. {} WALLMOUNTEDDUPLEXOURET ANCHORING,APPLVING,FINISHING,PROTECTING,CLEANINGETC. q. G.GTOMAINTAINEXISTINGULFlRERATEDASSEMBLVPoRALLPENETRATIONS. PROVIDE FURNISHANDINSTALL,COMPLETEREA�VFORTHEINTENDED 5 NLLNEWCOVERPLATES,STROBES,SWITCHES,ANDPLUG$ETGTOBEWHITEATPAINTEDANDFABRICWALLAREASU.O.N.ALLCOVERPLATESATWOO�VENEERWALLSTOBEBLACKU.O.N. N WALLMOUNTEDDEDICATEDOUTLET USE REPL4CEE%ISTINGCOVERPLATES,PWGS,SWITCHES,ETC.WITHNEW.SUBMITCOLORSELECTIONTOARCHITECTPRIORTOSTARTOFWORK. 0 WALLMOUNTEDJUNCTIONBOX 6. WHEREDEVICESARESHOWNBACKTOBACK,OFFSETASREQUIREDTOCOMPENSATEFORBO%ANDSTUDDIMENSIONS.USECENTERPOINTBETWEENDEVICELOCATIONSASREFERENCEPOINTFOR p FLOORMOUNTEDQUADOUTLET GFl-DENOTESGROUNDFAULTINTERRUPT LOCATION�IMENSIONU.O.N. +42"-INDICATESMOUNTINGHEIGHTA.F.F. ]. COORDINATE�EVICELOCATIONSPRIORTOSTARTOFWORKINCLU�ING,BUTNOTLIMITE�TO,THEFOLLOWINGCONDITIONSSVSTEMFURNITURELAVOUT,FREESTAN�INGANDBUILT-INFURNITURE, � FLOORMOUNTEDDUPLEXOUTLET MILLWORK,STRUCTURALCOLUMNLINESAT'POKE4HROUGH'LOCATIONS&FACEOFFlNISHATPARTITIONSANDFLOOR.WHEREAPPLICABLECONDUCTPRE-INSTALLATIONCONFERENCE. O WqLLMOUNTEDDATAOUTLET 8. WHERE'WHIPS'ARESCHEDULEDFORSVSTEMFURNITURE,PROVIDECOMPLETECODECOMPLIANTMSTALLATIONWCLUDING,BUTNOTLIMITEDTO'WHIP'MUSTBEVISIBLEANDREADILY � WALLMOUNTEDDATA,ICABLE ACCESSIBLE,SVSTEMFURNITURE'WHIP'INSTALLATION,HOOKUPANDACTNATIONSHALLCOMPLVWITHLOCALL4BORLAWSANDJURISDICTIONREQUIREMENTSINCWDINGUL,LOCATE'WHIP' 0 WALLMOUNTE�DATA,2CABLES OUTSI�ECLEARZONESREQUIREDFORCIRCULATION,ADAACCESSIBLEROUTESANDEXITPATH. 4 FUTUREVENDORSHALLCOORDINATEFURNITUREMSTALLATIONWITHPOWER/SIGNALDEVICELOCATIONS. � FWSHFLOORMOUNTEDTELEPHONE/DATAOUTLET TYP CONF. ROOM CORE LOCATIONS �a-PROVIDENEMIA ECEPTACLETVPESBASEDONEL�CTRICALANDDCOMMUNICATIONEqUIPMENTSPECIFlCATIONSASC00RDINATEDPRIORTOSTARTOFWORK � WALLMOUNTEDCARDREADER 12 FORDEDICATEDOUTLEfSANDRECEPTACLEMOUNTINGHEIGHT5DE51GNEDFORSPECIALEQUIPMENT,HEIGHTSHALLBEMEASUREDFORMTHEFlNISHEDFL00RTOTHECENTERLMEOFTHE OUTLET MOUNTED VERTICALLV, UNLESS NOTED OTHERWISE. RECEPTACLE, SW ITCH AND OUTLET MOUNTING HEIGHT DIMENSIONS ARE MEASURE� FROM FINISHED FLOOR TO OUTLET CENTERLINE � ELECTROMAGNEfICLOCK MOUNTEDVERTICALLV,UNLESSNOTEDOTHERWISE. TVP. TABLE BASE 13. PRIOR TO START OF W ORK VERIFV ANo C00RDINATE ELECTRICAL BUS DUCT AND CONDUIT, RISER AND HORIZONTAL ROUTING, RUN LOCATIONS, CIRCUITING AND WIRING PoR NEW WORK T0 E� EMERGENCVDOORRELEASEPULL r — — — — — � VALIDATEREQUIREDCLEARANCESBASEDONAS-BUILTRELDCONDITIONS.BRINGCONFLICTSWHEREOCCURTOARCHITECT'SATTENTION. EDGE OF TABLE —�'j I 14. ALL ELECTRICAL WORK nNo MATERInLS SHALL BE M COMPUANCE WITH THE W RRENT RULES AN� REGULATIONS OF THE NATIONAL BOARD OF FlRE UNDERWRITERS, THE STATE FlRE MARSHALL. � OCCUPANCV SENSOR RELEASE FACING MONITOR THE SAFETV ORDERS OF THE �NISION OF INDUSTRIAL SAFETV, DEPARTMENT OF INDUSTRIAL RELATIONS AND APPLICABLE CODES. FLL EQUIPMENT SHALL BE UL LABELED. BUILDING SERVICES AND UTILITV DISRUPTIONS TO THE BUILDING, INCLUDING ADJACENT TENANTS IN MULTbTENANT BUILDINGS ARE NOT PERMITTED �URING NORMAL BUS W E55 HOURS. ALL FIRE / LIFE SAFETV SVSTEMS � PUSHTOEXITRELEASEBUTTON I� 6 I I SHALLREMAINOPERATIONALDl1RING�EMOLITIONANDCONSTRUCTIONACTIVITIES�URINGNORMALBUSINESSHOURSPoRTEMPORARVDISRUPTIONSLIMITEDTOTHEAREAORWORK,AFTER GL.OFTABLE,ROOM, ��, --+ HOURSASNEEDEDTOCOMPLETETHEWORK,SCHEDULEDAVANDTIMEWITHOWNERINADVANCE,INWRITINGONANOVERTIMEBASIS.REESTABLISHALLBUILDINGSERVICESANDUTILITIESAT ANDAVMONITOR � CONCWSIONOFTEMPORARVSHUTOFF,ASSOONASPRACTICAL. �AREANOTINCONTRACT � — � 15.ALLSPEpALDEVICE,EQUIPMENTANDENGINEER'SITEMSARESHOWNFORCOOR�INATION&REFERENCEONLY.SECURITVIITIAVIMEPDWGGOVERNONQUANTITIES&LOCATIONSOFCAR� POWERCOREAS I READER,CAMERA,WAP,AV,SPRINKLERS,TVPES&HVACDIFFUSERS.ARCHITECTUREDRAWINGSGOVERNALLEXITSIGNSANDLIGHTINGFlXTURELOCATIONS. SCHEDULED �--- __ � 16.GCTOCOORDINATEINSTALLATIONOFCONDUITSLEEVESTHROUGHWALLSANDBULKHEADSASREQUIRE�FORINSTALLATIONOFLOW VOLTAGECABLING.SLEEVESTOBELOCATED SO AS TO PROVIDE FOR A NEAT AND ORGAMZED CABLE PATH WAV TO THE CEILING-MOUNTED J�HOOKS INSTALLED BY THE LOW VOLTAGE INSTALLER. SLEEVES TO BE 2" DIAMETER GLAVANIZEDCONDUIT,EXTENDINGMAXIMUM2"FROMWALLSURFACE(UNLESSDIRECTEDOTHERWISE),WITHPLASTICBUSHINGSONTHEENDS.GYPBOARDPENETRATIONSFOR CONDUITARETO BE FINISHEDWITHAPPROPRIATELV-SREDWHITEPLASTICGROMMETS. FEC E2] � n FEC ♦ ♦ � INDUSTRIOUS COWORKING 880 W MONON GREEN BLVD CARMEL, IN 46032 OWNEPRENANT INDUSTRIOUS 215PARKAVES,4E1300 NEW YORK, NY 1 W03 ARCXITECT OF HECOPD NORX 325 N LASALLE Si- SOIiE SCO CHICAGO. IL 60654 PEiER.DUBWCmNORR-COM 312-0242400 MEP ENGINEER MEENGINEERS 29 WEST 38iH SiREEi, SiH FLOOR NEW YORK. NY 10018 CONiACi: BRIAN SHASSIAN BBIANSHASSIANC�.ME-ENGINEER$_COM JOHN HIGGWS JOHN.HIGGWS(�MEENGINEERS.COM �212J 44]-6]]0 PHONE LIGHTING DESIGNER REGENCY 9261 JOkDAN AVE CHAiSWORiH, CA 800-28d-202J ISSUE DATES REV. DAiE DESCRIPiION BY CHECK 06/OS/2020 DD3 BG PJ 06/18/2020 CDvI BC PJ 0]/06/2020 CDv2 8C Po O]/V/2020 100%/PERMIT BC PJ PROJECTNAME CARMEL CITY- 880 MONON GREEN PRQIECT NUMBER IND680MON DRAWING TITLE POWER AND COMMUNICATION PLAN SCALE As indicated SHEET NUMBER A-110 � SEAL&SIGNATUNE