HomeMy WebLinkAboutG003 Specs01 GENERAL THE CONTRACTOR SHALL FURNISH ALL MATERIAL AN� EQUIPMENT REQUIRE� TO SATISFACTORILV COMPLETE THE INTERIOR RENOVATION AS INDICATED IN THE CONSTRUCTION DRAW WGS. A. PROJECT SUMMARY: CARMEL CLAV PUBLIC LIBRARY (TEMPOR4RY BRANCH) TO BE LOCATED AT 2140 E 116'" STREET, CARMEL, IN. B. SCOPE: INTERIOR OF EXISTING M OCCUPANCV TO BE CLEANED, PAINT EXISTWG WALLS IN ALL BUSINESS AND STACK AREAS OR AS NOTED. EXISTING TVPE IIB CONSTRUCTION - PROPOSED A3 OCCUPANCV. QEAN/PAINT E%ISTING DROP CEILINGS IN OCCUPIED AREAS OR AS NOTED. G CONTRACTORS SHOULD APPLV FOR, OBTAIN, AND PAV FOR PERMIT$ FEES AND UTILITY COMPANV FEES REQUIRED TO PERFORM THE WORK. �. CODES: COMPLV WITH APPLICABLE CO�ES AN� REGULATIONS OF AUTHORITIES HAVING JURISDICTION. SUBMIT COPIES OF INSPECTION REPORTS, NOTICES AND SIMILAR COMMUNICATIONS TO ARCHITECT. E DIMENSIONS'. VERIFY DIMENSIONS INDICATED ON DRAWINGS WITH FlELD DIMENSIONS BEPoRE FABRICATION OR ORDERING MATERIALS. DO NOT SCALE DRAW INGS. F. COORDINATE WORK OF ALL TRADES. VERIFV LOCATION OF UTILITIES AND EXISTING CONDITIONS. G. INSTALLATION REQUIREMENTS, GENERAL: a. INSPECT SUBSTRATES AND REPORT UNSATISFACTORT CONOITIONS IN WRITING. b. DO NOT PROCEED UNTIL UNSATISFACTORV CONDITIONS HAVE BEEN CORRECTED. c. TAKE FlELD MEASUREMENTS PRIOR TO FABRICATION WHERE PRACTICAL. tl. INSTALL MATERIALS IN PROPER RELATION W ITH AOJACENT CONSTRUCTION AND W ITH PROPER APPEARANCE. H. LIMIT OF USB LIMIT USE OF WORK AS INDICATED. KEEP DRNEWAYS AND ENTRANCES CLEAR. NOTIFV ARCHITECT OF EXISTING CONDITIONS DIFFERING FROM THOSE INDICATED ON DRAW MGS. DO NOT REMOVE OR ALTER STRUCTURAL COMPONENTS W ITHOUT PRIOR WRITTEN APPROVAL. A. MAINTAIN EXISTING 6 WLDING IN A WEATHERTIGHT CONDITION. REPAIR DAMAGE CAUSED BV CONSTRUCTION OPERATIONS. PROTECT BUILDING AND ITS OCWPANTS. 03 CONCRETE PATCH AND REPAIR EXISTING SLAB AS NECESSARV FOR LEVELWG. OS METALS A. COLPFORMED METAL FRAMING: INTERIOR NON-LOAD BEARWG PARTITIONS. SEE PLANS FOR WALL THICKNESS AND HEIGHTS. MANUFACTURER'S DATA SHEETS ON EACH PRODUCT ARE TO BE USED FOR PREPARATION, STORAGE & HANDLWG REQUIREMENTS AN� WSTALL METHODS. a. STUDS ARE TO BE 16"QQ 20GAUGE b. BEFOREBEGINNINGINSTALLATION,VERVTHATSUBSTRATECONDITIONSAREACCEPTABLEFOR INSTALLATION OF METAL FRAMING IN ACCORDANCE WITH MANUFACTURER'S INSTALL INSTRUCTIONS. VERIFV THAT ROUGH-IN UTIUTIES AND EXISTW G ASSEMBLIES ARE IN CORRECT LOCATIONS AND DO NO INTERFERE WITH FRAMING PLACEMENT. c. INSTALL FRQMING IN ACCORDANCE W ITH REQUIREMENTS OF ASTM C 100]. tl. FRAME WALL OPENINGS TO INCLUDE HEADERS AND SUPPORTING STUDS. COORDINATE ERECTION OF STUDS W ITH REpUIREMENTS OF DOOR FRAMES AND OTHER OPENINGS. OB OPENINGS MTERIOR WOOD DOORS: MANUFACTURER'S DATA TO BE USED FOR PREPPAR4TION AND WSTALLATION ON EACH PRODUCT TO BE USED. a. FLATPANEL-MAPLE,FACTORYPRIMED-COLORTOMATCHADJACENTWALL. b. DOOR THICKNESS 1314" TVPICA; DOOR HEIGHT ]'-0"; DOOR W IDTH 361N INTERIOR TEMPORARV DOORS a. DOORS TO BE PLVWOOD HINGE DOORS. b. 105C,105A.1056,108A,10]A. DOOR HARDWARP. ALL HARDWARE TO BE VERIFIED W ITH THE OWNER. a. COORDINATE FlNAL DOOR HARDWARE SCHEDULE W ITH DOORS 8 FRAMES TO ENSURE PROPER SIZE, THICKNESS, HAN�, AND FUNCTION. b. FINAL DOOR KEYING TO eE COORDINATED W ITH OW NER. c. ALL DOOR HARDWARE TO BE SATIN NICKEL FlNISH. tl. ALL EXISTING EXTERIOR DOOR LOCKS TO BE RE-KEVED. e. HINGES: BUTT HMGES - 44/2"H (3) PER STANDARD 36"x 84" �OOR f LEVERHANDLES:PERADARE(]UIREMENT g. CLOSERS: UNLESS OTHERWISE INDICATED, COMPLV WITH MANUFACTURER RECOMMENDATION FOR SRE AND LOCATION OF CLOSER. CLOSERS SHALL BE SET TO SERVE AS OVERHEAD STOP h. STOPS:WALLSTOPS,TVPICALPROVIDEWHEREVERNECESSARYTOPREVENTDOORTOHARDWARE FROM STRIKING AN ADJACENT PARTITION. i. SILENCERS: NEW INTERIOR DOORS, PROVIDE THREE SILENCERS PER SINGLE DOOR FRAME, SIX FOR DOUBLEDOORFRAMES. j. HARDWARE SCHEDULE: DOOR HAROWARE ITEMS HAVE BEEN PLACED M SETS W HICH ARE INTENDED TO BE A GUIDE OF DESIGN, GRADE, FUNCTION AN� MAV NOT BE COMPLETE. PROVIDE DOOR HARDWARE REQUIRED TO MAKE EACH SET COMPLETE AND OPERATIONAL. 1. INT DBL DOORS: STORAGE LOCKSET FUNCTION W ITH CLOSER ALLOW STAFF TO EXIT BUT NOT PATRON INTO OFFICE SPACE (102A) 2. INT SW WG �OOR�. OFFICE LOCKSET FUNCTION (102C, 103A, 111A, 112A) 3. INT SW ING DOOR'. STORAGE LOCKSET FUNCTION (105A, 105B, 105C, 101A, 108A, 113) 4. INT SWING DOOR'. PASSAGE FUNCTION W/CLOSER (103B) 5. INT SW WG DOOR�. EGRESS CRASH eAR & CLOSER (1078) RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel n�� ..�..A��ll.,a,ri.�..�.�� 09 FINISHES 12 FURNISHINGS TO BE BV OTHERS IN COORDINATION WITH OWNER 21 FIRE SUPPRESSION E%ISTING SVSTEM TO REMAIN. PROVIDE REQUIRED MAINTENANCE AND TESTING. 22 PLUMBING E%ISTING FIXTURES AND SERVICES TO REMAIN. PROVIDE REQUIRED MAIMENANCE AND TESTWG. 23 HEATING. VENTILATION. CWLING (HVAC) EXISTING SVSTEM TO REMAIN. PROVIDE REQUIREO MAINTENANCE ANO TESTING. 26 ELECTRICAL EXISTING SERVICE TO REMAIN. PROVIDE REQUIRED MAINTENANCE AN� TESTING. A. VERIFVCAPAGTVOFEXISTINGPANELSTOACCOMMODATEPROPOSEDNEWRECEPTA0.ES. 6. PROPOSEO EMERGENCV EXIT SIGNS SHOULD BE TIED TO EXISTING SVSTEM AND SHOULD HAVE BATTERV PACKS. C. VERIFV PROPOSED OUTLET LOCATIONS W ITH OW NER WHEN FRAMING IN INSTALLED. D. ANVNEWLIGHTRXTURES(LED)SHOULDBETIEDTOASWITCHASINDICATEDONELECTRICAL PLANS. E. BRINGCONDUITDOWNEXISTINGWLUMNSFROMABOVETOPOWERNEWFREE-STANDINGWALLS. F PROVIDE A LIGHT SW ITCH LOCATION MAP AT PROJECT CLOSEOUT FOR OWNER USE OR COOROINATE TIMERSIOVERRIDES FOR EXISTING LIGHTING THROUGHOl1T. PAINT: SUBMIT 3 PAPER SAMPLES 8.SX11 OF EACH COLOR SELECTED. COLORS TO BE SELECTED BV OW NER. a. LOWVOCPAINTCOATINGS,TVPICAL b. ALL PAINT SHALL BE REA�V-MIXE� AND PRE-TINTED. c. WHEREPAINTISTOBESPRAVED,THINACCORDINGTOMANUFACTURER'SGUIDELWES. d. PAINTEDDRVWALLISTOBEPAINTEDl151NGAWATER-BASEDACRVLIGEGGSHELLFINISH. e. PAINTED INTERIOR DOORS ARE TO BE PAINTED W ITH ACRVLIC wATER-BASEq SATIN FINISH. PATCH AND REPAIR CRACKS/HOLES. REMOVE DUST AN� LOOSE PARTICULATE FROM SURFACES RECEIVING COATINGS IMMEDIATELV PRIOR TO COATING APPLICATION. REMOVE OR PROTECT E�UIPMENT/FI%TURES A�JACENT TO SURFACES TO RECEIVE COATINGS. CARPET/ CARPET TILES: VERIFV W ITH OW NER AVAILIBILITY OF CARPET TILES TO BE REUSED IN PROPOSED SPACE. OW NER TO RECOMMEND DESIRED LOCATION OF REFERENCED CARPET TILE. FLOOR HEIGHT TRANSITIONS CANNOT EMCEED'/:' WITHOUT PROPER TRANSITION STRIP. NOTIFY ARCHITECT OF ANV EXISTING LOCATIONS THAT CONFLICT WITH THAT REQUIREMENT. DATE: O$�Z5I2O ```��„a���` ��Pflf���� ��V:�4'iYi;.,�P�-.� ��r' N0� �''i: __ * ; AR19500143 ; * _ mxv :' 3 �i�'i'9Q..1��IIL.`� ``��� .��TCH iT1� "`��. peterson ARCHITECTURE � � � � � J U � � � � � U W � L � U N NZ t— �O N W � U V N �� ■■ u CONSTRUCTI ON DOCUMENTS 07I24I2020 REVISIONS'. � REVISION REVISION 2 OATE REVISION 3 DATE REVISION 4 OATE REVISION 5 DATE PLOT DATE: DRAWN BV: J. FIELD CHECKEDBV: T.ANKER PROJECT NUMBER: 20-OW2 SPECIFICATIONS G003 THESE DRAWINGS AFE GNEN IN CONFlOENCE ANO SHALL BE USED ONLY IN PURSOANi TO THE ncaEEn�ENrwirH PETERSON ARCHITECTURE, P.C. rvo arHEa usE oa ouPucnnory n�av eE mnoE wirnouT THE vaiore waiTTEN corvsENT oF PETERSON ARCHRECTURE, P C. ALL OTHER COPYRIGHT AND COMMON LAW RIGHiS ARE HEREBY SPEQFICALLY RESERVED.