Loading...
HomeMy WebLinkAboutCover Sheet-G00001101 �U D I -m DN Do D(_0 � N �z s, 0 0 �U i o 5 F o DI J W ry - x i` �ss 00 � N 0 N Do �N J I D0 )I � I co -1 CD i Adw qj-lr- MAINTENANCE BUILDING AND SITE WORK GENERAL NOTES 1. CONTRACTOR TO CLEAN AND DAMP MOP ALL WORK AREAS AND WORK TRAFFIC AREAS AT THE END OF EAC H DAY. 2. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS PRIOR TO SUBMITTING BID. 3. ALL PATCHING OF EXISTING CONSTRUCTION TO REMAIN SHALL BE DONE TO MATCH EXISTING MATERIALS AND FINISHES AND SO AS TO NOT VOID ANY EXISTING PRODUCT WARRANTIES. 4. THE GENERAL CONTRACTOR SHALL COORDINATE AND SUPERVISE THE WORK OF ALL TRADES AND FIELD VERIFY ALL DIMENSIONS PRIOR TO INSTALLATION OF SUBCONTRACTORS' WORK. CONTRACTOR SHALL PAY FOR ALL COSTS ASSOCIATED WITH CHANGES DUE TO LACK OF COORDINATION. 5. THE CONTRACTOR SHALL FURNISH SAMPLES AND SHOP DRAWINGS OF ALL EQUIPMENT AND FINISHES FOR REVIEW AND APPROVAL IN ACCORDANCE WITH THE REQUIREMENTS OF THE CONTRACT AND SPECIFICATIONS. 6. ALL WORK SHALL CONFORM WITH THE MORE STRINGENT GUIDELINES FOR INSTALLATION AS ESTABLISHED BY THE PRODUCT MANUFACTURER OR THE RELEVANT STANDARDS ORGANIZATION. 7. WHERE UTILITY SERVICES ARE REQUIRED TO BE REMOVED, RELOCATED, OR MODIFIED, PROVIDE BYPASS CONNECTIONS TO MAINTAIN CONTINUITY OF SERVICE TO OTHER PARTS OF THE BUILDING BEFORE PROCEEDING WITH THE WORK. 8. SEALANT REQUIRED FOR ALL EXTERIOR APPLICATIONS SHALL BE A TWO—PART POLYURETHANE MODIFIED SEALANT. SEALANT USED AT ALL DUCT, PIPE AND CONDUIT PENETRATIONS THROUGH WALLS AND FLOOR SLABS SHALL BE MANUFACTURED BY HILTI AND SHALL MEET UL REQUIREMENTS FOR THE FIRE RATED ASSEMBLIES BEING PENETRATED. PROVIDE CONTINUOUS HILTI FIRESAFING AT ALL DUCT, PIPE AND CONDUIT PENETRATIONS THROUGH WALLS AND FLOOR SLABS. 9. THE CONTRACTOR SHALL PROTECT ALL EXISTING SITE AND BUILDING CONDITIONS FROM DAMAGE DUE TO CONSTRUCTION. THE CONTRACTOR SHALL REPAIR OR REPLACE EXISTING CONDITIONS DAMAGED DURING CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER. 10. SURVEY, INVENTORY AND RECORD THE CONDITION OF ITEMS TO BE REMOVED AND REINSTALLED WITH THE OWNER, SURVEY EXISTING CONDITIONS PRIOR TO THE START OF WORK. 11. WHEN EXISTING MECHANICAL, ELECTRICAL, OR STRUCTURAL ELEMENTS CONFLICTING WITH THE INTENDED FUNCTION OR DESIGN ARE ENCOUNTERED, INVESTIGATE AND MEASURE THE NATURE AND EXTENT OF THE CONFLICT. PROMPTLY SUBMIT A WRITTEN REPORT TO THE ARCHITECT. 12. MAINTAIN UTILITIES EQUIPMENT IN SERVICE AND PROTECT AGAINST DAMAGE DURING CONSTRUCTION. DO NOT INTERRUPT EXISTING UTILITIES SERVING OCCUPIED OR OPERATING FACILITIES, EXCEPT WHEN AUTHORIZED IN WRITING BY THE BUILDING MANAGER AND AUTHORITIES HAVING JURISDICTION. IF REQUIRED BY THE OWNER, AT THE CONTRACTORS EXPENSE, PROVIDE TEMPORARY SERVICE DURING INTERRUPTIONS TO EXISTING UTILITIES. PROVIDE NOT LESS THAN 10 WORKING DAYS PRIOR NOTICE TO THE OWNER AND BUILDING MANAGER IF SHUTDOWN OF SERVICE IS REQUIRED. 13. ANY WORK NEAR ACTIVE TELECOMMUNICATIONS EQUIPMENT SHALL BE DONE DURING AT&T MAINTENANCE HOURS (10:OOPM — 6:OOAM). THE CONTRACTOR SHALL PROTECT THE TELECOMMUNICATIONS EQUIPMENT PER THE LATEST AT&T STANDARDS, AND TO THE SATISFACTION OF THE AT&T BUILDING MANAGER. EQUIPMENT PROTECTION REMAINING IN PLACE FOR MORE THAN 24 HOURS SHALL BE CONSTRUCTED IN SUCH A WAY AS TO ALLOW ACCESS TO THE EQUIPMENT AND ACCOMMODATES EQUIPMENT VENTILATION REQUIREMENTS. 14. ASBESTOS CONTAINING MATERIALS (ACM) IS STRICTLY PROHIBITED FROM BEING INSTALLED ON ALL AT&T PROJECTS. SHOULD ACM BE INADVERTENTLY INSTALLED ON PROJECTS, PROPER REMOVAL, DISPOSAL AND REPLACEMENT WITH APPROVED PRODUCT SHALL BE THE SOLE RESPONSIBILITY OF THE INSTALLING CONTRACTOR AT NO COST TO THE OWNER. 96TH STREET GARAGE 4160 E. 96TH STREET INDIANAPOLIS IN 46280 SHEET NUMBER SHEET TITLE GENERAL G00001 COVER SHEET CIVIL C00001 GENERAL NOTES C00002 EXISTING CONDITIONS C10001 DEMOLITION PLAN C20001 SITE PLAN C30001 GRADING PLAN C30002 GRADING PLAN DETAIL C40001 UTILITY PLAN C40002 UTILITY PLAN DETAIL C40003 UTILITY PLAN DETAIL C50001 SESC PLAN C50002 STORMWATER POLLUTION PREVENTION PLAN (SWPPP) C50003 SESC DETAILS C60001 DETAILS C60002 DETAILS C60003 DETAILS C60004 DETAILS LANDSCAPE L10001 LANDSCAPE PLAN L20001 LANDSCAPE DETAILS ARCHITECTURAL A00001 GENERAL NOTES A10101 FLOOR PLAN A50001 DETAILS A50002 ELEVATIONS PLUMBING P10102 EXISTING BUILDING FLOOR PLAN P60001 SCHEDULES AND DIAGRAMS ELECTRICAL 00101 FLOOR PLAN DRAWING INDEX 1LADAY HILLS AND DALES E M E 96th St LOCATION MAP E 7 D6th St BUILDING CODE ANALYSIS GENERAL PROJECT INFORMATION OWNER: AT&T CORPORATE REAL ESTATE AUTHORITY HAVING JURISDICTION: INDIANAPOLIS, IN CODE REVIEW BUILDING: 2014 INDIANA BUILDING CODE (BASED ON 2012 IBC) ELECTRICAL: 2009 INDIANA ELECTRICAL CODE (NFPA 70-2008) PLUMBING: 2012 INDIANA PLUMBING CODE MECHANICAL: 2014 INDIANA MECHANICAL CODE (BASED ON 2012 IMC) ENERGY: 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1 2007) FIRE: 2014 INDIANA FIRE CODE (IFC 2012) TYPE OF CONSTRUCTION: IIB—NON SPRINKLERED OCCUPANCY CLASSIFICATION: GROUP S1 — (AUTO REPAIR GARAGE) EXITS REQUIRED: 2 AREA OF WORK: w. MAINTENANCE BUILDING: NEW SITE WORK: E 706th St = Lar71 REDONE PAVING: NUMBER OF STORIES: 1 4160 East 96th Street 3 E 96th St E 961h St E 96th St E 96th St River Road Apartments FTWOOD gpourLadyof L L S Peace Cemetery The Fashion Mall at Keystone y E 86th St north 465 LOCATION MAP NOT TO SCALE I�l•�]:Z�191�I���a 1,920 SF. 40,488 SF. 60,819 SF. PROJECT DIRECTORY BUILDING OWNER: CONTRACTOR: NIGEL DOWNTON KIERAN HOSEY AT&T CORPORATE REAL ESTATE GILBANE BUILDING COMPANY 240 MERIDIAN ST. 240 N. MERIDIAN ST. ROOM 120 ROOM 120 INDIANAPOLIS, IN 46204 INDIANAPOLIS, IN. 46204 317-265-4403 317-550-6506 EMAIL: ND2147@ATT.COM EMAIL: KHOSEY@GILBANECO.COM ARCHITECT/ENGINEER EXP US SERVICES, INC. 150 EAST GAY STREET SUITE 1510 COLUMBUS, OH. 43215 614-744-4300 PROJECT SUMMARY CONTACTS: ARCHITECTURAL: MARCIA BASCHNAGEL: 614-744-4316 EMAIL: MARCIA.BASCHNAGEL©EXP.COM ELECTRICAL: MICHELLE STAFFAN: 614-744-4324 EMAIL: MICHELLE.STAFFAN@EXP.COM MECHANICAL: RICHARD STALNAKER: 804-474-4562 EMAIL: RICHARD.STALNAKER@EXP.COM THE SCOPE OF THE PROJECT IS TO BUILD A NEW MAINTENANCE BUILDING, PAVING, AND FENCE. \\\\\! ,'E.. STq�. ST A4Nq'%, �C.>; QE, RFC •.�F No. PE119000�295 • / % • A: STATE 0 �\ /ONAL \\ �inniiiiiii O BAS 10 00057 •: R1 STATE Y..... •• GEC �o. o• '' •� m nv PROJECT NAME: 96TH STREET GARAGE MAINTENANCE BUILDING AND SITE WORK COL-00255676-Ai CONSULTANT STAMP Exp A/E, Inc. t: +1.614.744.4300 1 f: +1.614.744.4350 150 E. Gay Street Suite 1510 Columbus, OH 43215 U.S.A. www.exp.com ex . • BUILDINGS • EARTH & ENVIRONMENT • ENERGY* • INDUSTRIAL • INFRASTRUCTURE • SUSTAINABILITY • REVISIONS / AUTHORIZATIONS NO. REVISIONS / AUTHORIZATIONS DATE BY BULLETIN 3 08/03/20 M B BULLETIN 2 07/16/20 M B PERMIT ISSUE 06/26/20 M B BULLETIN 1 06/19/20 M B ADDENDUM A 06/09/20 M B BID ISSUE 05/14/20 M B CID ISSUE 2 05/07/20 M B PROPRIETARY AT&T INFORMATION NOT FOR GENERAL USE OR DISCLOSURE OUTSIDE OF AT&T THIS INFORMATION MAY ONLY BE USED BY AUTHORIZED PERSONNEL OF THE LOCAL GOVERNMENT AGENCY IN CONNECTION WITH APPLICATION FOR PERMITS AND AUTHORIZATIONS FOR BUILDINGS, CONSTRUCTION, AND/ OR ZONING CHANGES. _ DRAWINGS PREPARED FOR AT&T CORPORATE REAL ESTATE PROJECT DRAWING 4160 E. 96TH STREET INDIANAPOLIS IN US CRMLIN02 116427.01 N26102 SHEET TITLE: COVER SHEET GENERAL AT&T PROJECT NUMBER: DATE: --- SCALE: --- M 2 8 3 0 4 DRAWN BY: --- CHECKED BY: --- AT&T AUTHORIZATION: SHEET: - OF: - SHEETS SHEET NO. AT&T DRAWING NO.: AT&T PM: NIGEL DOWNTON M28304000001 000001