HomeMy WebLinkAboutCivil Site Plan-C20001 (V2)SITE INFORMATION TABLE
PARKING SPACES BUILDING SQUARE FOOTAGE SITE ACREAGE IMPERVIOUS SURFACE AREA PERCENT OF SITE COMPOSED
OF IMPERVIOUS SURFACES
EXISTING CONDITIONS NO EXISTING STRIPING 45,749 SF 5.02 AC 2.50 AC
50%
3
LEGEND
CURB AND GUTTER
REVERSE PITCH CURB AND GUTTER
REVERSE PITCH, DEPRESSED CURB AND GUTTER
Rm��
MULCH
GREENSPACE
2" HMA SURFACE COURSE
1.5" HMA SURFACE COURSE, 2.5" BINDER COURSE
CONCRETE PAD
CONCRETE
SITE PLAN KEY NOTES "O"
1. CONCRETE CURB AND GUTTER PER DETAILS 4/C60001, 5/C60001,
AND 6/C60001.
2. HMA PAVEMENT PER DETAIL 2/C60001.
3. HMA OVERLAY PER DETAIL 3/C60001.
4. CONCRETE CURB PER DETAIL 1 1 /C60001.
5. CONCRETE SIDEWALK PER DETAIL 7/C60001.
6. 6" PIPE BOLLARD PER DETAIL 8/C60001. RE -USED BOLLARDS TO
BE PLACED IN ORIGINAL LOCATION.
7. CONCRETE DUMPSTER PAD PER DETAIL 9/C60001.
A3I T E 0
9. INSTALL MOTORIZED SLIDING GATE PER DETAIL 1 /C60004. OWNER
TO PROVIDE KNOX SWITCH TO GRANT THE CARMEL FIRE DEPARTMENT
ACCESS TO_THE GATED_AREA. _ _ _ _ _ _ _ _ _ _
A3
north
T"0. -AUA-PARKING-"STALLS"PER" DETAILS 1%C6U002; 2%C60602, ANU -
3/C60002..
11. CONCRETE BUILDING PAD PER STRUCTURAL PLANS.
12. STORMWATER DETENTION BASIN.
13. CONCRETE TO MATCH EXISTING THICKNESS.
14. CONCRETE APRON PER DETAIL 10/C600.
15. INSTALL LIGHT POST PER ELECTRICAL PLANS.
16. SIGN TO BE INSTALLED BY OTHERS.
17. INSTALL 18-001 GOOSENECK PEDESTAL (OR APPROVED EQUAL) AND
ADVANTAGEDK ADV-1000 KEYPAD (OR APPROVED EQUAL). CONCRETE
FOUNDATION TO BE INCLUDED WITH PEDESTAL.
18. INSTALL LOOP DETECTOR FOR GATE SYSTEM. CONTRACTOR TO
DETERMINE LOOP SIZE AND LOCATION.
20. DESIGNATED AREA FOR AT&T 'TRAINING ACTIVITIES.
21. BIKE RACK PER DETAIL 1 /C60001. BIKE RACK FOR EXISTING
BUILDING TO HAVE 5 BIKE SPACES. BIKE RACK FOR NEW
STAND-ALONE BUILDING TO HAVE 2 BIKE SPACES.
PROPOSED CONDITIONS 84 SPACES 47,669 SF 5.02 AC 2.91 AC 58% GRAPHIC SCALE
( IN FEET )
1 inch = 30 ft.
AUTHORIZATION:
J&T PM: NIGEL DOWNTON