HomeMy WebLinkAboutPope, Roger Remodel PlansEXISTING ENTRY FOYER EXSTING LIVING ROOM EXITING CLOSET EXISTINGBATH EXISTING MASTERBATH REMOVE EXISTING WALLS REMOVE EXISTING WINDOW AND REPLACE WITH NEW BOX BAY REMOVE EXISTING RAILING AND REPLACE WITH A NEW WALL remove and wall up existingopenings note that there will be a new door put partially intothis opening see new floor plan 2'-0" 0'-0" 10'-8"15'-4"1'-1112"verify 2x12 floor joist 16" oc use jst hangers to attach newjoist to existing box plate cut in new crawl space access existing offset 12'-4" verify existing stairs replace existing windows withthe new center window being egress exisiting decorative window 2-10 x 6-8 existing closet 3-0 x 6-8 3-0 x 6-83-0 x 6-8replace existing window 71"w x 4212 d x 7612 tsauna by owner3' x 5' accessibleshower base w/ custom glass enclosure window seat judy's sit down vanity 4'-0"0'-412"3'-1112"D W 18" base cabinets w/ wall cabinets above towel shelves shelves 6'-134" 6'-614" 12'-8"15'-4"7'-8"7'-8" 2' x 4' islandchest of drawers10'-8" 0'-938" 5'-0" 0'-938" 6'-634" ridge vent134 x 1178 LVL shingles to match existing 58" decking 2x6 rafters 16" c/c 2x8 clg jst 16"c/c 7'-4" 0'-4" 1'-0" metal roof edge 34" faciamatch existing gutter continuous vent34" soffit 118 x 5 14 frieze house wrap horizontal siding to match existing 12" structural sheathig metal clad drip cap 118" x 1114 aprongrade 8" cmu with # 4 rebars incement filled cores 48" ocwaterproofing 4" foundation drain withgranular backfill 2" riged foam insulation 2" concrete slab on 6m vapor barrier8'-118"2x4 studs 16"c/c new additionexisting home North east corner of existing home standing seam copper roof grade 60"x60" picturewindow with interior privacyshutters NEW BOXBAY WINDOW 118 X 514TRIM36X40 BAND BOARDWITH DRIPCAP HORIZONTAL SIDING TOMATCH EXISTING HOME SHINGLE ROOF TO MATCHEXISTING HOME RIDGE VENT 36X40 HORIZONTAL SIDING TOMATCH EXISTING HOMEHORIZONTAL SIDING TOMATCH EXISTING HOME 118 X 514TRIM 6" RAKE 16" W X 12" D CONC FOOTING WITH (4) # 4 REBARS replace existing window replace existing windows with the new center window beingegress new closet addition HORIZONTAL SIDING TOMATCH EXISTING HOME roof cricket SHINGLE ROOF TO MATCHEXISTING HOME 1'-414" Roger and Judy Pope, Carmel Indiana. March of 2020 SCALE: 1/4"=1'-0" EXISTING HOME SCALE: 1/4"=1'-0" FLOOR PLAN SCALE: 1/4"=1'-0" FOUNDATION PLAN SCALE: 1/4"=1'-0" DEMOLITION PLAN SCALE: 1/4"=1'-0"--STRUCTURAL SECTION SCALE: 1/4"=1'-0"--WEST ELEVATION SCALE: 1/4"=1'-0"--NORTH ELEVATION SCALE: 1/4"=1'-0"--EAST ELEVATION 08/28/20 Mike Sheeks