Loading...
HomeMy WebLinkAboutA001.01900 Golf Road - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2020 Zach Bittner08/04/2014 RIGHT Rockwall 2054.300.00.CPM LOT 6 07/30/2020 PLOTTED: July 30, 2020 / Prem Kumar / 2054-ROCKWALL-CZ-BASE-PLAN.DWG A0 BB-1.1Basement Foundation Plan..SCALE:BASEMENT FOUNDATION PLAN1/4" = 1'-0" LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.) LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.) BASEMENT - UNFINISHEDSLAB (SEE STRUCTURAL PLANS) 23415678 910 UP 16 RISERS SLOPE CONCRETE SLABUNEXCAVATED(SEE STRUCTURAL PLANS) 4140 SL & EGRESS WELL #2, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS ROUGH IN BATH 1112 SUMP w/ CHECK VALVE - VERIFY LOCATION IN FIELDPROVIDE 10' MIN. SEPARATION BETWEEN WATER & SEWER LINES (PER CODE) \A1;58'-7" OVERALL\A1;12'-0"\A1;29'-0" \A1;64'-7" OVERALL \A1;58'-7" \A1;6'-0" \A1;17'-7"\A1;6'-3{\H0.750000x;\S1#2;}"\A1;5'-8{\H0.750000x;\S1#2;}" \A1;4'-2" \A1;3'-10{\H0.750000x;\S1#2;}" \A1;18'-4" \A1;9'-6{\H0.750000x;\S1#2;}"\A1;10'-9{\H0.750000x;\S1#2;}" \A1;4'-3{\H0.750000x;\S1#2;}" \A1;2'-0" \A1;12'-0"\A1;8'-1{\H0.750000x;\S1#2;}" \A1;5'-8{\H0.750000x;\S1#2;}" \A1;19'-0"\A1;10'-0" \A1;6'-10{\H0.750000x;\S1#2;}" \A1;25'-9" \A1;5'-9"\A1;3'-10{\H0.750000x;\S1#4;}" \A1;16'-2{\H0.750000x;\S1#2;}" \A1;6'-0" \A1;10'-10" \A1;3'-7" \A1;64'-3{\H0.750000x;\S1#2;}" OVERALL \A1;28'-0" \A1;30'-7" \A1;18'-0" \A1;10'-0" 2A2 B.2 2A2 B.2 1A2 B.1 1A2 B.1 POST & BEAM PER STRUCTURAL PLANS POST & BEAM PER STRUCTURAL PLANSPOST & BEAM PER STRUCTURAL PLANS PERIMETER DRAIN, PER SPEC \A1;6'-11{\H0.750000x;\S1#2;}" \A1;5'-2" \A1;5'-10{\H0.750000x;\S1#2;}" \A1;2'-0" LEAD WALL PAST OVERDIG, TYP. (SEE STRUCTURAL)\A1;9'-8{\H0.750000x;\S1#2;}" \A1;20'-1{\H0.750000x;\S1#2;}"\A1;12'-0{\H0.750000x;\S1#2;}" CONCRETE SLABUNEXCAVATED(SEE STRUCTURAL PLANS) \A1;11'-2{\H0.750000x;\S1#2;}"\A1;11'-8{\H0.750000x;\S1#2;}" \A1;58'-7" OVERALL\A1;10'-1"\A1;10'-7"\A1;26'-7{\H0.750000x;\S1#2;}"\A1;11'-0"\A1;3{\H0.750000x;\S1#2;}" \A1;8'-3" \A1;4'-2" \A1;1'-9" \A1;16'-3" \A1;8'-11{\H0.750000x;\S1#2;}" LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION (TYP.) POST & BEAM PER STRUCTURAL PLANS \A1;23'-8" \A1;8'-0" \A1;11'-10" \pxql;LEAD WALL PAST OVERDIG, TYP. (SEE STRUCTURAL) \A1;19'-2{\H0.750000x;\S1#2;}" \A1;5'-8{\H0.750000x;\S1#2;}" \A1;14'-7" SLAB LEDGE, PER DETAILPERIMETER DRAIN, PER SPEC CONCRETE SLABUNEXCAVATED(SEE STRUCTURAL PLANS) FOUNDATION NOTES\pxi-3,l3,t3;{\LGENERAL SPECIFICATIONS\P}\P1. WHERE DISCREPANCIES BETWEEN SOILS REPORT AND STRUCTURAL DRAWINGS OCCUR, CONTACT THE STRUCTURAL ENGINEER.\P2. FINISH GRADE SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURE.\P3. SURFACE WATER TO DRAIN AWAY FROM STRUCTURE. THE GRADE SHALL FALL A MINIMUM OF 6" WITHIN THE FIRST 10 FEET (2% FOR IMPERVIOUS SURFACES)IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES.\P4. GARAGE SLAB SHALL SLOPE A MIN. OF 2" AWAY FROM STRUCTURE.\P5. CONCRETE STOOPS AND PORCH/PATIO SLABS SHALL SLOPE A MIN. OF 1/4" PER FOOT AWAY FROM STRUCTURE.\P6. PROVIDE BEARING LEDGE FOR MASONRY AS INDICATED BY STRUCTURAL DRAWINGS.\P7. FOR ADDITIONAL INFORMATION SEE STRUCTURAL DRAWINGS AND NOTES 08/27/20 Adam Schriner