0.11Finished Basement Utility PlanOptional Lighting PackageAll Basement Walls3S
TO SWITCH ABOVE
R
S HVAC
BASEMENT - FINISHED
STORAGE
WIC
BEDROOM 7
FINISHED BASEMENT FLOOR PLAN
R
R
R
R
R
R
R
R
R
\A1;8'-0"\A1;8'-0"\A1;8'-0"\A1;7'-7"
\A1;2'-10"
\A1;5'-0"
RR
RRSSS
\A1;6'-7"\A1;2'-7"
\A1;7'-0"
\A1;2'-5"
OPT. LIGHT/FAN\PBRACE AND PRE-WIRE
BATH 7
\pxi-2,l2,ql,t3;{\T0.9;1. ALL ELECTRICAL INSTALLATION SHALL MEET THE REQUIREMENTS OF THE CURRENTLY ADOPTED EDITION OF THE NATIONAL ELECTRIC CODE (NEC). AND INTERNATIONAL RESIDENTIAL CODE (IRC). ALL MATERIAL AND EQUIPMENT SHALL BEAR THE LABEL OF APPROVAL OF THE UNDERWRITERS LABORATORIES, INC. AND MEET THE REQUIREMENTS OF THE CURRENTLY ADOPTED EDITION OF THE NEC.\P2. STAIRWAYS WITHIN DWELLING UNITS SHALL HAVE AN ILLUMINATION LEVEL ON THE TREAD RUNS OF NOT LESS THAN 1 FOOTCANDLE. PROVIDE LIGHTING CONTROL AT EACH LEVEL. EXTERIOR STAIRWAYS SERVING A DWELLING UNIT SHALL HAVE A LIGHT IN THE IMMEDIATE VICINITY OF THE STAIR LANDING CLOSEST TO THE DWELLING UNIT.\P3. GFCI PROTECTION SHALL BE PROVIDED FOR ALL 125 VOLT, SINGLE PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED IN THE FOLLOWING LOCATIONS:\P\pi-3,l5,q*,t6;3.1. BATHROOMS\P3.2. GARAGE\P3.3. OUTDOORS: BALCONIES, DECKS, AND PORCHES (INCLUDING INSIDE SCREENED ENCLOSURES)\P3.4. UNFINISHED BASEMENT AREAS AND CRAWL SPACES\P3.5. SINKS LOCATEDUTILITY NOTESUTILITY LEGEND
SYMBOL SYMBOL TYPE ADDITIONAL NOITESADDRESS SIGNADDRESS SIGN - VISIBLE FROM STREET. LETTERS OR NUMBERS FOR THE ADDRESS SHALL BE 4" MIN. IN HEIGHT AND 0.5" MIN. IN STROKE OF A CONTRASTING COLOR TO THE BACKGROUND ITSELF
CHIMES - DOORBELLDETECTOR - HEATCEILING MOUNTED HEAT DETECTOR TO BE HARD WIRED TO FIRE ALARM SYSTEM (INSTALL PER CODE) DETECTOR - SMOKE/CARBON MONOXIDE COMBINATIONUL APPROVED CEILING MOUNTED SMOKE /CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE)
DETECTOR - CARBON MONOXIDEUL APPROVED CEILING MOUNTED CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE)
DETECTOR - SMOKEUL APPROVED CEILING MOUNTED SMOKE DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE)DISCONNECT - SWITCHEDFAN - CEILING W/ LIGHTFAN BOX PER CODE. PROVIDE 4-WIRE CABLE FROM SWITCH(ES) (CLG FAN OPTIONAL)FAN - EXHAUSTEXHAUST TO EXTERIORFAN - EXHAUST W/ LIGHTEXHAUST TO EXTERIORLIGHT - CEILINGLIGHT - CEILING-PULL CHAINLIGHT - FLUORESCENT-48X9LIGHT - FLUORESCENT-UNDER CAB-14LIGHT - RECESSEDLIGHT - RECESSED-VAPOR PROOFLIGHT - WALLLIGHT - WALL-PULL CHAINMETER - ELECTRICVERIFY LOCATION IN FIELDOUTLET - 220VOUTLET - DISHWASHEROUTLET - DUPLEXOUTLET - DUPLEX-SPLIT WIREDOUTLET - FLOOROUTLET - GFIOUTLET - GARAGE DOOROUTLET - PHONECAT 5EOUTLET - TVRG-6OUTLET - WATERPROOF-GFIPANEL - ELECTRICVERIFY LOCATION IN FIELDSWITCH - DISPOSALSWITCH - LIGHTSWITCH - THREE WAYSWITCH - FOUR WAYSWITCH - PUSH BUTTONTHERMOSTATTHERMOSTAT SHALL BE PROGRAMMABLEHOSE BIBBWATER SERVICEGAS VALVEGAS METERRETURN AIR GRILLEWATER METER
HS/CCS
PC
14RVPCE220VDW
GFIGFIPHTVWP/GFISDISPS3SS4THBOPT.\PWATER LINEGAS VALVEGR.A.G.W