HomeMy WebLinkAboutS101 - FOUNDATION PLANUPUP 24' - 8"11' - 0" 5' - 0" 1' - 4" 9' - 3" 1' - 4" 9' - 3" 4' - 6" 15' - 0" 11' - 4" 40' - 8" 35' - 8" 43' - 0" 16' - 0" 24' - 8" 6' - 0" 37' - 0" 26' - 4" 1 A401 SEW A201 1 A2013 A201 2 A201 4 Basement W SW SFURNLVL BEAM LVL BEAM COLUMNCOLUMN 15' - 0" 15' - 0" WALL ROUGH IN ONLY 12' - 4" 40' - 8" 37' - 0" 16' - 0" 6' - 0" 43' - 0" 3' - 6" 18' - 4" G000 2 RADON PIT WINDOW WELL TW3046SUMP SUMP6"x14" POCKET 6"x14" POCKET 6"x14" POCKET COLUMN COLUMN COLUMN 1 A401 C2017 CALIBRATED CONSULTING 654 Hickory Dr Tipton, IN 46072 T 765-432-8150 General Contractor: PROJECT #: DRAWN BY: CLIFF 24x36 SHEET: 11x17 SHEET: SCALE BRYAN RAGAN CONS. 3056 S. 100 E. TIPTON, IN 46072 T 765-292-2502 F 765-292-2502 CALIBRATED CONSULTING LLC DATE:JUNE 16, 2020 1/4" = 1'-0"Jennifer BairdNEW HOME310 2nd Street SouthwestCarmel, IN 4603200210 S101 FOUNDATION PLAN 1/8" = 1'-0" Living Space Name Area Level Bedroom 2 215 SF Main Level Powder 30 SF Main Level Foyer 43 SF Main Level Main Bathroom 49 SF Main Level Laundry 64 SF Main Level Mudroom 48 SF Main Level Hearth Room 396 SF Main Level Kitchen 365 SF Main Level Coat Closet 11 SF Main Level Stair 38 SF Main Level Dining 221 SF Main Level Closet 2 46 SF Main Level Pantry 18 SF Main Level Loft 471 SF Second Floor Master Closet 66 SF Second Floor Master Bedroom 265 SF Second Floor Master Bathroom 113 SF Second Floor Bedroom 3 202 SF Second Floor Total Living Space Level Area Main Level 1544 SF Second Floor 1116 SF Grand total: 18 2660 SF Non Living Space Name Area Level Basement 1544 SF Basement Garage 630 SF Main Level Back Porch 129 SF Main Level Front Porch 152 SF Main Level Grand total: 4 2455 SF GENERAL NOTES THE CONTRACTOR IS SOLELY RESPONSIBLE FOR FIELD VERIFICATION OF EXISTING SITE AND GRADES. 1. THE CONTRACTOR HOLDS RESPONSIBILITY TO REVIEW ALL PLANS FOR ACCURACY TO CORRECTLY UNDERSTAND HIS RESPONSIBILITY OF THE SCOPE OF WORK AND ASSUMES COMPLETE LIABILITY OF MISUNDERSTOOD DESIGN OR OMISSIONS IN DESIGN. 2. STRUCTURAL COMPONENTS ARE DESIGNED AS A CLOSE APPROXIMATION AND MAY CHANGE AT ANY TIME. IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY NEEDS AND SIZES EVEN IF SHOWN ON THE PLANS. 3. CONTRACTORS RESPONSIBILITY TO FOLLOW ALL LOCAL AND STATE BUILDING CODES 4. SCHEDULES ARE EXACT MEASURES MEANING NO WASTE HAS BEEN CALCULATED INTO TOTALS. 5. FRAMING NOTES DIMENSIONS -ALL DIMENSIONS ARE PULLED FROM STRUTURAL FRAMING; TYPICAL NOMINAL LUMBER SIZES ARE DRAWN ACCURATELY, I.E. 2X4 STUD IS DRAWN 1.5"X3.5", FRAMED WALLS ARE 2X4 UNLESS NOTED OTHERWISE, FOUNDATION WALLS ARE 8" UNLESS NOTED OTHERWISE 1. WALLS -9' CEILINGS ON MAIN, 8' CEILINGS ON BASEMENT, 8' CEILINGS ON SECOND FLOOR, 2X4 INTERIOR WALLS, 2X4 EXTERIOR WALLS 2. DOOR ROUGH-IN -KEEP DOOR ROUGH-INS A MINIMUM 4-1/2" AWAY FROM WALL CORNERS TO ALLOW FOR PROPER INSTALLATION OF CASEWORK 3. WINDOWS -ANDERSON WINDOWS SERIES PRODUCT NUMBER SPECIFIED. IF OTHER MODEL OR MANUFACTURER IS USED PLEASE USE MATCHING WINDOW SIZE. 3. RevisionsNo. Date Description08/28/20 Nick Mishler