Loading...
HomeMy WebLinkAboutA101 - FIRST FLOOR PLANDN UP UP WD DN A201 1 Hearth Room Kitchen Mudroom Laundry Main Bathroom Powder Foyer Dining Garage Front Porch Back Porch Stair A2013 A201 2 A201 4 Bedroom 2 Closet 2 Pantry DOWN TO BASEMENT UP TO LOFT AREA WOOD CEILING SLOPE CEILING TO UPSTAIRS POST ARCH SECOND LEVEL BALCONY LVL BEAM 2-8 Steel Insulated 9'x 7.5' OVERHEAD 9'x 7.5' OVERHEAD 2-8 Steel Insulated 2-8 2-6 2-8 Steel Insulated 2-8 2-8 Steel Insulated 2-6 P.D. CW25 CW25 2-6 2-6 2-0 3-0 FRONT DOOR CXW13 CXW13 CXW13 CXW13 C25 2-6 C25 3' - 6" 24' - 0"11' - 0" 5' - 0" 40' - 0" 15' - 4" 24' - 8" 42' - 4" 26' - 4" 36' - 8" 26' - 0" 40' - 0" 68' - 8" 21' - 0"6' - 1" 8' - 4"4' - 0" 7' - 3" 7' - 6" 3' - 9" 5' - 7" 3' - 6" 6' - 1"12' - 4" 5' - 5"9' - 6"3' - 6" 2' - 6" 15' - 0"3' - 4" 6' - 4" 5' - 5" 10' - 3 15/16" 8' - 2 1/16" 18' - 5" 15' - 1" 2-6 C25 G000 2 SOAKER TUB 1 A401 2 A401 HVAC 2-6 P.D. 2' - 0" 4' - 0" PULL DOWN ATTIC ACCESS C2017 CALIBRATED CONSULTING 654 Hickory Dr Tipton, IN 46072 T 765-432-8150 General Contractor: PROJECT #: DRAWN BY: CLIFF 24x36 SHEET: 11x17 SHEET: SCALE BRYAN RAGAN CONS. 3056 S. 100 E. TIPTON, IN 46072 T 765-292-2502 F 765-292-2502 CALIBRATED CONSULTING LLC DATE:JUNE 16, 2020 1/4" = 1'-0"Jennifer BairdNEW HOME310 2nd Street SouthwestCarmel, IN 4603200210 A101 FIRST FLOOR PLAN 1/8" = 1'-0" Drywall Take-Off Use Area 4x8 Sheets Gypsum Ceiling Board 2070 SF 65 Gypsum Wall Board 8485 SF 265 Interior Door Schedule Size Count 2-0 1 2-6 9 2-8 4 5-0 1 Grand total: 15 Misc. Door Schedule Size Count 2-6 P.D. 3 2-8 Steel Insulated 4 3-0 FRONT DOOR 1 9'x 7.5' OVERHEAD 2 Plywood Take-Off Size Area 4x8 Sheets Plywood, Sheathing 3/4" 2752 SF 86 Plywood, Sheathing 5/8" 3803 SF 119 Plywood, Sheathing 7/16" 3341 SF 104 Stud Wall Schedule Length Stud Count W/O Cripples & Corners 612' - 0" 459 Window Schedule Designation Count Type Rough Opening Height Rough Opening Width CR14 2 17" x 48" 4' - 0 1/2" 1' - 5 1/2" CXW13 6 35-15/16" x 35-15/16" 3' - 0 7/16" 3' - 0 7/16" TW3046 1 37-5/8" x 56-7/8" 4' - 9 3/8" 3' - 2 1/8" C25 5 C25 C35 1 C35 CW25 4 CW25 Roof Schedule Area Description 3806 SF Fascia & Gutter Schedule Type Length Fascia-Flat 6" 314' - 0" Living Space Name Area Level Bedroom 2 215 SF Main Level Powder 30 SF Main Level Foyer 43 SF Main Level Main Bathroom 49 SF Main Level Laundry 64 SF Main Level Mudroom 48 SF Main Level Hearth Room 390 SF Main Level Kitchen 365 SF Main Level Coat Closet 11 SF Main Level Stair 38 SF Main Level Dining 221 SF Main Level Closet 2 46 SF Main Level Pantry 18 SF Main Level Loft 470 SF Second Floor Master Closet 66 SF Second Floor Master Bedroom 271 SF Second Floor Master Bathroom 113 SF Second Floor Bedroom 3 202 SF Second Floor Total Living Space Level Area Main Level 1537 SF Second Floor 1121 SF Grand total: 18 2658 SF Non Living Space Name Area Level Basement 1544 SF Basement Garage 630 SF Main Level Back Porch 129 SF Main Level Front Porch 152 SF Main Level Grand total: 4 2455 SF Exterior Coverings Covering Area MASONRY BRICK - Ext 3341 SF Shaker Siding - Ext 96 SF GENERAL NOTES THE CONTRACTOR IS SOLELY RESPONSIBLE FOR FIELD VERIFICATION OF EXISTING SITE AND GRADES. 1. THE CONTRACTOR HOLDS RESPONSIBILITY TO REVIEW ALL PLANS FOR ACCURACY TO CORRECTLY UNDERSTAND HIS RESPONSIBILITY OF THE SCOPE OF WORK AND ASSUMES COMPLETE LIABILITY OF MISUNDERSTOOD DESIGN OR OMISSIONS IN DESIGN. 2. STRUCTURAL COMPONENTS ARE DESIGNED AS A CLOSE APPROXIMATION AND MAY CHANGE AT ANY TIME. IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY NEEDS AND SIZES EVEN IF SHOWN ON THE PLANS. 3. FRAMING NOTES DIMENSIONS -ALL DIMENSIONS ARE PULLED FROM STRUTURAL FRAMING; TYPICAL NOMINAL LUMBER SIZES ARE DRAWN ACCURATELY, I.E. 2X4 STUD IS DRAWN 1.5"X3.5", FRAMED WALLS ARE 2X4 UNLESS NOTED OTHERWISE, FOUNDATION WALLS ARE 8" UNLESS NOTED OTHERWISE 1. WALLS -9' CEILINGS ON MAIN, 8' CEILINGS ON BASEMENT, 8' CEILINGS ON SECOND FLOOR, 2X4 INTERIOR WALLS, 2X4 EXTERIOR WALLS 2. DOOR ROUGH-IN -KEEP DOOR ROUGH-INS A MINIMUM 4-1/2" AWAY FROM WALL CORNERS TO ALLOW FOR PROPER INSTALLATION OF CASEWORK 3. CONTRACTORS RESPONSIBILITY TO FOLLOW ALL LOCAL AND STATE BUILDING CODES 4. SCHEDULES ARE EXACT MEASURES MEANING NO WASTE HAS BEEN CALCULATED INTO TOTALS. 5. WINDOWS -ANDERSON WINDOWS SERIES PRODUCT NUMBER SPECIFIED. IF OTHER MODEL OR MANUFACTURER IS USED PLEASE USE MATCHING WINDOW SIZE. 3. RevisionsNo. Date Description08/28/20 Nick Mishler