Loading...
HomeMy WebLinkAboutA121 ELECTRICAL PLAN & REFLECTED CEILINGMICROVITROSPANTHERFREEZERBYTENANTREFRIGBYTENANTREFRIGBYTENANTPANTHERVERNA'S OFFICE 103 WORK AREAS 104 COPY 105 BREAK + MEET 106 TOM CATU.C.FREEZERENTRY + DROP-OFF 102 TVU.C.REFRIGCYTO REVIEW 110 VESTIBULE 101 STORAGE 119 LAB 108 FUTURE NIPT 118 FUTURE NIPT 117 FUTURE NIPT 116 FUTURE NIPT 115 PATHOLOGY OFFICE 114 PATHOLOGY OFFICE 113 SAFETY SHOWER 4X4 HISTOLOGY + CYTOLOGY 107 GROSSING 109 E411 ON TABLE REFRIG BY TENANT VISION ON TABLE 4' HOODON COUNTERMORTECH ON COUNTER TISSUEPROCESS.ON FLOORSERVER/IT 111 STG. 112 HCPARAFFINHCCOLDPLATEMICROTOMEBONDMAX45 GALLON SAFETY CAB TISSUEWATERBATHTHINPREP5000IMAGINGTHINPREP5000AUTOLOADERCOVERSLIPPERAUTOSTAINERCOVERSLIPPERAUTOSTAINERREFRIG BY TENANT REFRIGBYTENANTP +60" +60" DED +60" +42" +42" GFCI GFCI DEDDED+42"+42"+42" DED+42"DEDDEDDEDGFCI DEDDED DED DED +42"+42"J J J +42" +42" +42" GFCI GFCI DED+42"+42"BC BC NEW STATIONS BC BC LFLF NEW STATIONS BCBC MICROVITROSPANTHERFREEZERBYTENANTREFRIGBYTENANTREFRIG BY TENANT PANTHER VERNA'S OFFICE 103 WORK AREAS 104 COPY 105 BREAK + MEET 106 TOM CATU.C.FREEZERENTRY + DROP-OFF 102 TVU.C.REFRIGCYTO REVIEW 110 VESTIBULE 101 STORAGE 119 LAB 108 FUTURE NIPT 118 FUTURE NIPT 117 FUTURE NIPT 116 FUTURE NIPT 115 PATHOLOGY OFFICE 114 PATHOLOGY OFFICE 113 SAFETY SHOWER 4X4 HISTOLOGY + CYTOLOGY 107 GROSSING 109 E411 ON TABLE REFRIG BY TENANT VISION ON TABLE 4' HOODON COUNTERMORTECH ON COUNTER TISSUEPROCESS.ON FLOORSERVER/IT 111 STG. 112 HCPARAFFINHCCOLDPLATEMICRO TOMEBONDMAX45 GALLON SAFETY CAB TISSUEWATERBATHTHINPREP5000IMAGINGTHINPREP5000AUTOLOADERCOVERSLIPPERAUTOSTAINERCOVERSLIPPERAUTOSTAINERREFRIG BY TENANT REFRIGBYTENANTP +60" +60" DED +60" +42" +42" GFCI GFCI DEDDED+42"+42"+42" DED+42"DEDDEDDEDGFCI DEDDED DED DED +42"+42"J J J +42" +42" +42" GFCI GFCI DED+42"+42"BC BC NEW STATIONS BC BC LF LF NEW STATIONS BC BC ELNL NL ELN ELNELNSNSNSNSNSNSNSNSN3SN3 SN3ELNELNELN ELN SNSN3SN3 SN3SN3ELNL NL ELN ELNELNSNSNSNSNSNSNSN SN3SN3 SN3ELNELNELN ELN SNSN3SN3 S N3SN3FREEZERFREEZERREFLECTED CEILING PLAN A121 REFLECTED CEILING PLAN DESCRIPTIONDATE ISSUE 06.29.20 REVIEW SET 07.08.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR OBGYN OF INDIANAPENNWOOD ONE | SUITE 25011405 N PENNSYLVANIA ST, CARMEL, IN 46032JREH 2020.077 1ST FLOOR N AREA NOT IN CONTRACT AREA OF WORK AREA NOT IN CONTRACT AREA OF WORK ELECTRICAL PLAN NOTES ELECTRICAL PLAN DED POWER OUTLET, DUPLEX NEW CONSTRUCTION EXISTING TO REMAIN POWER OUTLET, QUADRUPLEX POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX POWER AND DATA POLE DEDICATED CIRCUIT DATA/COMMUNICATION OUTLET (PROVIDE BOX AND PULL STRING ONLY) DATA/COMMUNICATION OUTLET GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET HEIGHT OF ELECTRICAL OR DATA DEVICE ELECTRICAL LEGEND ELECTRICAL PLAN/ A121 1 MECHANICAL DIFFUSER RELOCATION A121 1 *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION RCP PLAN NOTES EXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN RELOCATE DIFFUSERS & FLEXDUCT IF REQUIRED VAV / HEAT PUMP GENERAL ELEC. NOTES CONTRACTOR TO CONSULT WITH LANDLORD AND TENANT TO CONFIRM IF ADDITIONAL COOLING IS BEING PROVIDED IN SERVER/IT ROOM. AT LAB 108, PROVIDE SEPARATE HVAC CONTROL FOR VITROS AND PANTHER EQUIPMENT. COORDINATE WITH TENANT TO DETERMINE IF SEPARATE UNIT IS REQUIRED. PROVIDE PROTECTOR, PREMIER, 4', NO SRV, 115V, 60H VENTILATION HOOD (OR EQUAL) AT HISTOLOGY AREA EXTENDING THROUGH ROOF. COORDINATE ALL REQUIREMENTS WITH TENANT. IF POSSIBLE, ENSURE SERVER/IT 121 IS ON A SEPARATE ZONE. PROVIDE ZONING DIAGRAM TO TENANT AND BUILDING MANAGEMENT FOR REVIEW. PROVIDE NEW CEILING GRID AND TILE AS SHOWN TO MATCH AND ALIGN WITH EXISTING SUCH THAT NEW AND EXISTING CEILINGS APPEAR CONTINUOUS. DESIGN INTENT IS FOR NEW AND EXISTING LIGHT FIXTURES IN WORK AREAS 104 AND COPY 105 AND LAB 108 TO BE CONTROLLED BY NEW 3-WAY LIGHT SWITCH AS INDICATED ON PLAN. DESIGN INTENT IS FOR NEW LIGHT SWITCH TO CONTROL EXISTING LIGHT FIXTURES IN CYTO REVIEW 110. DESIGN INTENT IS FOR NEW LIGHT SWITCH TO CONTROL EXISTING LIGHT FIXTURES IN GROSSING 109. DESIGN INTENT IS FOR NEW LIGHT SWITCH TO CONTROL EXISTING LIGHT FIXTURES IN VERNA'S OFFICE 103. DESIGN INTENT IS FOR NEW 3-WAY LIGHT SWITCHES TO CONTROL EXISTING LIGHT FIXTURES IN STORAGE 119. DESIGN INTENT IS FOR NEW LIGHT SWITCH TO CONTROL NEW AND EXISTING LIGHT FIXTURES IN HISTOLOGY + CYTOLOGY 107. PROVIDE NEW 5" WIDE BULKHEAD AT 8'-10"A.F.F AT THIS LOCATION. ALL SIDES OF BULKHEAD TO BE PAINTED IN SHERWIN WILLIAMS SW7007 CEILING BRIGHT WHITE, FINISH: FLAT. NEW BULKHEAD TO ALIGN AS SEAMLESSLY AS POSSIBLE TO ADJACENT BUILDING ELEMENT OR WALL AS SHOWN ON PLAN. PROVIDE AND INSTALL NEW, MOISTURE RESISTANT CEILING TILES IN SHOWER AREA. 0 2' 4' 8' 16' 1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL NEW DEVICES AND FACE PLATES TO MATCH EXISTING. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 5. PROVIDE AND INSTALL 24"X36"X8-10"D TRANSFER SWITCH. EXACT LOCATION TO BE CONFIRMED WITH ELECTRICIAN. +42" COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE ON SEPARATE 20 AMP CIRCUIT AS REQUIRED. PROVIDE POWER AS REQUIRED AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE DETAILS. PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S FURNITURE VENDOR. PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT 60" A.F.F. PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH TENANT. IF POSSIBLE, CONVERT EXISTING BLANK/OPEN BOXES TO NEW RECEPTACLES AS SHOWN ON PLAN. IF NOT POSSIBLE, REMOVE BLANK/OPEN BOX AND PROVIDE NEW RECEPTACLE AS REQUIRED. PROVIDE POWER AS REQUIRED FOR TENANT PROVIDED DOOR BELL. CONFIRM EXACT LOCATION AND REQUIREMENTS WITH TENANT. CONFIRM POWER REQUIRED WITH TENANT FOR TENANT PROVIDED SPECIAL EQUIPMENT AT THIS LOCATION. POWER FOR SPECIAL EQUIPMENT TO BE ON SEPARATE CIRCUIT WHERE POSSIBLE. PROVIDE JUNCTION BOX AND DATA ABOVE CEILING FOR POWER POLE FOR TENANT'S EQUIPMENT. COORDINATE EXACT LOCATIONS WITH TENANT. POWER POLE TO BE PROVIDED BY LANDLORD. PROVIDE RECESSED ELECTRICAL PANEL AT THIS LOCATION. ONCE DOOR IS CLOSED, ELECTRICAL PANEL TO BE CENTERED ON 30" CLEAR WIDTH AND HAVE 36" DEEP OF CLEAR SPACE IN ACCORDANCE WITH STATE AND LOCAL CODES. ADJUST LOCATION OF DOOR AS REQUIRED. REFER TO ENLARGED PLAN FOR POWER SPECIFICATIONS. CONFIRM LOCATION OF TRANSFER SWITCH WITH TENANT'S IT DEPARTMENT. PROVIDE JUNCTION BOX ABOVE CEILING FOR POWER POLE CONNECTION. POWER POLE BY OTHERS. LIGHT SWITCH N EXIT LIGHT FIXTURE RECESSED LIGHT FIXTURE LIGHT FIXTURE, 2'x2', FLUORESCENT, INDIRECT LIGHT FIXTURE, 1'-6"x4', FLUORESCENT, INDIRECT RELOCATED DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 20"x5' CEILING GRID, SUSPENDED, 2'x4' NEW OR RELOCATED EXISTING TO REMAIN EXIT LIGHT FIXTURE LIGHT SWITCH CEILING GRID, SUSPENDED, 20"x5' CEILING GRID, SUSPENDED, 2'x4' DIFFUSER, LAY-IN, 2'x2' LIGHT FIXTURE, 2'x2', FLUORESCENT, INDIRECT LIGHT FIXTURE, 1'-6"x4', FLUORESCENT, INDIRECT RCP LEGEND RECESSED LIGHT FIXTURE EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE SWITCH, GARBAGE DISPOSAL (ABOVE COUNTERTOP) NG G SWITCH, GARBAGE DISPOSAL 1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING GRID IS 20"x5' OR 2'x4' AT 9'-0" A.F.F. TILES ARE 20"x5' OR 2'x4' SECOND LOOK TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. IF IN GOOD CONDITION, EXISTING CEILING TILES SALVAGED FROM DECONSTRUCTION CAN BE SUBSTITUTED FOR NEW. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 4. THE LIGHT FIXTURES SHOWN AS "NEW OR RELOCATED" ARE TO BE RELOCATED FROM A PREVIOUS LOCATION AS SHOWN ON THE DEMOLITION PLAN, UNLESS NOTED OTHERWISE. THE DESIGN INTENT IS LESS THAN 50% OF THE LIGHTS ARE ACTUALLY BEING REPLACED WITH NEW AND OVERALL WATTAGE IS STAYING THE SAME OR DECREASING. LAYOUT SHOWN IS EXEMPT FROM ASHRAE 90.1 STANDARDS. 5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 7. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS.  ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 8. PROVIDE SEPARATE PRICE TO REPLACE ALL EXISTING GRID WITH ARMSTRONG 2'X4' 15 16" GRID ASSEMBLY (OR EQUAL) WITH STANDARD LAY IN CORTEGA THROUGHOUT AND TO REPLACE ALL EXISTING LINEAR LIGHT FIXTURES WITH WITH COLUMBIA LIGHTING, CCL 2'X4' LED LIGHT FIXTURES THROUGHOUT. GENERAL NOTES 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. MECHANICAL NOTES 0 2' 4' 8' 16' LIGHT FIXTURE, 20"x5', FLUORESCENT, INDIRECT LIGHT FIXTURE, 20"x5', FLUORESCENT, INDIRECT CEILING BULKHEAD CEILING BULKHEAD LIGHT SWITCH, 3-WAY N3 LIGHT SWITCH, 3-WAY NIGHT LIGHTNL RELOCATED DIFFUSER, LAY-IN, 20"x20" DIFFUSER, LAY-IN, 20"x20" ENLARGED SERVER/IT 111 PLAN 0 1' 2' 4' NEMA 5-20R, +60" NEMA 5-20R NEMA 5-20R NEMA L5-30P + NEMA 5-20R 09/03/20