HomeMy WebLinkAboutC600 - Storm Plan & Profile-C601SCALE: 1"=50' HOR.
1"=5' VERT.
845
850
860
845
850
860
0+00+25+50+751+00+25+50+752+00+25+50+753+00+25+50+754+00+25+50+755+00+25 YARD INLET #803STA. 0+00TC=859.0548" DIA MH275 L.F. 0.37% 12" R.C.P. CLASS III
853.48
854.49YARD INLET #805STA. 2+75TC=859.2030" x 30" BOX237 L.F. 0.30% 12" R.C.P. CLASS III
854.59
855.30YARD INLET #806STA. 5+12TC=859.3724" x 24" BOX12" R.C.P. CLASS III E
INV.=853.48
15" R.C.P. CLASS III W
INV.=853.38
12" R.C.P. CLASS III N
INV.=853.48
I.E. 856.3
6" SSDI.E. 856.4
6" SSDI.E. 856.6
6" SSD
PROPOSED
GRADE
EXISTING
GRADE
HYDRAULIC PROFILE
GRADE LINE
EX. SANITARY
MH #JG 601
(OUTSIDE DROP)
T.C.=857.54
18" PS115 NE
INV.=833.65
18" PS115 S
INV.=833.55
8" S.D.R. 35 P.V.C. W
INV.=848.79
EX. CURB INLET #801
T.C.=856.31
12" R.C.P. NE
INV.=852.49
12" R.C.P. W
INV.=852.39
EX. YARD INLET #692
T.C.=851.84
12" R.C.P. W
INV.=848.84
EX. YARD INLET #691
T.C.=853.38
12" R.C.P. E
INV.=849.96
EX. OUTLET
CTRL. STR. #693
T.C.=853.31
12" R.C.P. W
INV.=850.85
EX. END SECTION #678
15" R.C.P. N
INV.=853.02
EX. END SECTION #802
12" R.C.P. E
INV.=851.92
EX. END SECTION #695
12" R.C.P. SW
INV.=849.46
EX. END SECTION #694
12" R.C.P. E
INV.=850.69
EX. END SECTION #684
12" R.C.P. NE
INV.=850.84
C.A. #29
EX. BMP 15A EX. BMP 15B
EX. BMP 15CEX. BMP 14B
EX. BMP 14C
C.A. #29
C.A. #29
5'SIDEWALK
807
803
324 L.F. 12" R.C.P. @ 0.41%
245 L.F. 15" R.C.P. @ 0.45%
684
676
677
30 L.F. 12" R.C.P. @ 0.34%
678181 L.F. 15" R.C.P. @ 1.33%806
805
237 L.F. 12" R.C.P. @ 0.30%
275 L.F. 12" R.C.P. @ 0.37%WWWWWWWWWWWWWWWWWWWWWWWWWWW
W W W
WWWWWWW804
164 L.F. 21" R.C.P. @ 0.37%40'
B
.
L
.
40' B.L.
40' B.L.40' B.L.40' B.L.40' B.L.40' B.L.VAR. B.L.VA
R
.
B
.
L
.
VAR. B.L.VAR. B.L.40'
B
.L
.
VAR. D.U.&S.S.E.5' B.L.20' D.&U.E.20' D.&U.E.
35' D.&U.E.
20'
D
.
&
U
.
E
.
30' D.&U.E.
VAR. D.U.&S.S.E.VAR. D.U.&S.S.E.20' D.U.&S.S.E.30' D.U.&S.S.E.40'
D
.U
.&S
.S
.E
.VAR. D.U.&S.S.E.VAR. D.U.&S.S.E.VA
R
.
D
.
U
.
&
S
.
S
.
E
.
20' T.O.B.S.L.&R.D.E.&U.E.&B.M.P.E.20' T.O.B.S.L.&R.D.E.&U.E.&B.M.P.E.15' R.D.E.15' R.D.E.30' D.E.30' D.E.30' T.P.E.&L.B.30' T.P.E.&L.B.30' T.P.E.&L.B.30' T.P.E.&L.B.30' T.P.E.&L.B.30' T.P.E.&L.B.VAR. B.L.VAR. D.U.&S.S.E.857
858
859856857858859860860857858859683
30' D.&U.E.30' D.&U.E.30' D.&U.E.30' D.&U.E.JG714
JG713
JG712
JG711
JG601
JG710ALMOND CREEK DRIVE(PRIVATE)A L MOND CREEK
D
RIV
E (
P
R
I
V
A
ALMOND CREEK DRIVE (PRIVATE)
328 329
321
322
326
319
332
331330
327
323
325
324
320 317318
C.A. #37
VAR. B.M.P.E.&R.D.E.&U.E
145 L.F. 15" R.C.P. @ 0.32%C.O.5' SIDEWALK
5' SIDEWALK5' SIDEWALK5' SIDEWALK5'SIDEW
ALK244 L.F. 12" R.C.P. @ 2.52%74 L.F. 12" R.C.P. @ 0.80%
810
809
808
30' D.&U.E.
5' T.P.E.&L.B.5' T.P.E.&L.B.5' T.P.E.&L.B.50' I.E.E.&D.U.&S.S.E.50' I.E.E.&D.U.&S.S.E.50' I.E.E.&
D.U.&S.S.E.
50' I.E.E.&
D.U.&S.S.E.30' B-BSTA. 1
0
+
0
5.
2
0
100-Yr.
E
L.
8
5
2.
3
5
SCALE: 1"=50' HOR.
1"=5' VERT.
845
850
860
845
850
860YARD INLET #809STA. 0+74TC=855.8324" x 24" BOXEND SECTION #808STA. 0+00(w/ DEBRIS GUARD)YARD INLET #810STA. 3+18TC=861.5624" x 24" BOX0+00 +25 +50 +75 1+00 +25 +50 +75 2+00 +25 +50 +75 3+00 +25
244 L.F.
2
.
5
2
%
1
2
"
R
.
C
.
P
.
C
L
A
S
S
I
I
I
851.71
857.87
74 L.F. 0.80%
12" R.C.P. CLASS III
UP INV.=851.61
DOWN INV.=851.01
I.E. 858.9
6" SSD
I.E. 851.5
6" SSD
PROPOSED
GRADE
EXISTING
GRADE DATEMARKREVISIONSBYCERTIFIED:S & A JOB NO.
SHEET NO.
DRAWN BY:CHECKED BY:S T O E P P E L W E R T HA L W A Y S O N7965 East 106th Street, Fishers, IN 46038-2505phone: 317.849.5935 fax: 317.849.5942THIS DRAWING IS NOT INTENDED TO BE REPRESENTED AS A RETRACEMENT OR ORIGINAL BOUNDARY SURVEY, A ROUTE SURVEY OR A SURVEYOR LOCATIONREPORT.STORM SEWER PLAN & PROFILESC601
60160REP-S7
PDR BKR CARMEL, CLAY TOWNSHIPHAMILTON COUNTY, INDIANA12/18/19File Name:S:\60160REP-S7\DWG\C600 - Storm Plan & Profile.dwg - C601Modified / By:July 7, 2020 9:54:03 AM / dmetzPlotted / By:September 2, 2020 8:00:17 AM / Brian RobinsonJACKSON'S GRANT ON WILLIAMS CREEKSECTION 703/09/20REVISED PER TAC COMMENTSDSM07/15/20REVISED PER TRICO COMMENTSDSMLEGEND
EXISTING SANITARY SEWER
EXISTING STORM SEWER
EXISTING WATER LINE
PROPOSED SANITARY SEWER
PROPOSED STORM SEWER
PROPOSED WATER LINE
DENOTES FULL DEPTH GRANULAR BACKFILL
(SEE TRENCH DETAIL 10-31 ON SHEET C80X)
NOTES
ALL STORM STRUCTURES TO RECEIVE SOLID LID CASTINGS ARE TO BE
CONSTRUCTED TO PROVIDE ONE 4" RISER RING NO MORE, NO LESS TO
ACHIEVE PLAN RIM GRADE.
ALL YARD INLETS ARE TO BE CONSTRUCTED AT A TOLERANCE OF +0.00'
TO -0.20' OF PLAN GRADE.
ALL STORM SEWER CASTINGS SHALL BE LABELED "DUMP NO
WASTE-DRAINS TO WATERWAY"
ALL SSD'S (SUBSURFACE DRAINS) WILL NEED TO BE DOUBLE WALL
SMOOTH BORE PERFORATED (HDPE) PIPE.
DEBRIS GUARDS ARE TO BE INSTALLED ON ALL OPEN ENDED INLETS.
FOR STORM STRUCTURE SIZING AND CASTING TABLE SEE STANDARD
PLAN D-18 ON SHEET C801A.
ALL STORM SEWERS WITHIN PUBLIC RIGHT-OF-WAY SHALL BE RCP
CLASS III.
FOR INSTALLATION OF STORM UNDER CITY STREETS AND COVER
REQUIREMENTS, SEE STANDARD DRAWING 10-31 ON SHEET C801A.
ALL TOP OF CASTING ELEVATIONS FOR STORM SEWERS SHALL BE
CONSTRUCTED WITH A TOLERANCE OF 0.10 FT±.
STORM SEWERS FOR THIS DEVELOPMENT WILL BE PUBLIC.
MINIMUM COVER FOR PIPE CROSSINGS OF CITY STREETS:
THE MINIMUM COVER FROM THE TOP OF THE INSTALLED PAVEMENT TO
THE TOP OF THE INSTALLED PIPE SHALL BE THE PAVEMENT SECTION,
THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE
SUBGRADE) PLUS 1'-0", BUT UNDER NO CIRCUMSTANCES SHALL THE
COVER ALONG ANY PART OF THE PIPE FROM THE FINAL PAVEMENT
ELEVATION TO THE TOP OF THE PIPE BE LESS THAN 2.5 FEET.
THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN
SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL
APPROVED CONSTRUCTION PLANS. DESIGN SPECIFIED AND AS
APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED
CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN
SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR
DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD
APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OR
CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN
ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE
INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS
SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED
DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR
LESS AND 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL
REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION,
PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO
AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO
ENSURE COMPLIANCE WITH THE DESIGN PLANS, AND AS APPROVED BY
THE CITY OF CARMEL.
UTILITY CROSSINGS
CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE
UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY
CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS.
CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE
CONTRACTOR'S RESPONSIBILITY.
GRAPHIC SCALE
( IN FEET )
1" = 50 FT
APPROXIMATE LIMITS OF FLOODWAY,
AS SCALED FROM FIRM MAP
PANEL NOS.: 18057C0206G / 208G
DATED: NOVEMBER 19, 2014
APPROXIMATE LIMITS OF FLOODWAY FRINGE,
AS SCALED FROM FIRM MAP
PANEL NOS.: 18057C0206G / 208G
DATED: NOVEMBER 19, 2014
FWF(FIRM)
FWF(FIRM)
Floodplain Zone AE scaled from
FIRM Panel No. 18057C0206G / 208G
Dated November 19, 2014