PLOTTED: August 10, 2020 / Kamlesh Bisht / 3007-IN-MEPP.DWG First Floor Electrical Plan6.10\pxql,t1;{\T0.9;ALL ELECTRICAL INSTALLATION SHALL MEET THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE (N.E.C.). ALL MATERIAL AND EQUIPMENT SHALL BEAR THE LABEL OF APPROVAL OF THE UNDERWRITERS LABORATORIES, INC. AND MEET THE REQUIREMENTS OF THE N.E.C..\P\P1. STAIRWAYS WITHIN DWELLING UNITS SHALL HAVE AN ILLUMINATION LEVEL ON THE TREAD RUNS OF NOT LESS THAN 1 FOOTCANDLE. PROVIDE LIGHTING CONTROL AT EACH LEVEL. EXTERIOR STAIRWAYS SERVING A DWELLING UNIT SHALL HAVE A LIGHT IN THE IMMEDIATE VICINITY OF THE STAIR LANDING CLOSEST TO THE DWELLING UNIT. \P\P2. GFI PROTECTION SHALL BE PROVIDED FOR ALL 125 VOLT, SINGLE PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED IN THE FOLLOWING LOCATIONS:\P - BATHROOMS\P - GARAGE\P - OUTDOORS: BALCONIES, DECKS, AND PORCHES (INCLUDING INSIDE SCREENED ENCLOSURES)\P - UNFINISHED BASEMENT AREAS AND CRAWL SPACES, EXCEPT FOR LAUNDRY CIRCUIT AND SINGLE RECEPTACLE DEDICATED TO SUMP PUMPS\P - RECEPTACLES INTENDED TO SERVE KITCHEN COUNTER TOP SURFACES\P - RECEPTACUTILITY NOTESElectrical Schedule TableSymbol
Type
Additional Notes
S/CS PCR 220VDWGFIPHTVWP/GFISDISPS3SDETECTOR - SMOKE/CARBON MONOXIDE COMBINATIONDETECTOR - SMOKEFAN - CEILING W/ LIGHTFAN - EXHAUSTFAN - EXHAUST W/ LIGHTFAN - EXHAUST-VENT TO EXTERIORLIGHT-CEILING-PULLCHAINLIGHT - CEILINGLIGHT - RECESSEDLIGHT - WALLOUTLET - 220VOUTLET - DISHWASHEROUTLET - DUPLEXOUTLET - DUPLEX-SPLIT WIREDOUTLET - GFIOUTLET - PHONEOUTLET - TVOUTLET - WATERPROOF-GFISWITCH - DISPOSALSWITCH - LIGHTSWITCH - THREE WAY
UL APPROVED CEILING MOUNTED SMOKE /CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER R314.4)110V W/ BATTERY BACKUP\PINTERCONNECTEDFAN BOX PER NEC. PROVIDE 4-WIRE CABLE FROM SWITCH(ES) (CLG FAN OPTIONAL)50 CFM MIN INTERMITTENT FAN EXHAUST TO EXTERIORCAT 5ERG-6
\A1;2'-3"
\A1;2'-10{\H0.750000x;\S1#2;}"
\A1;5"
\A1;6{\H0.750000x;\S1#2;}"
\A1;14'-2"
\A1;11'-8{\H0.750000x;\S1#2;}"
\A1;12'-0"\A1;5'-9{\H0.750000x;\S1#2;}"
\A1;1'-7{\H0.750000x;\S1#2;}"
\A1;15'-0"
\A1;1'-3{\H0.750000x;\S1#2;}"
\A1;2'-0"
\A1;3'-0{\H0.750000x;\S1#2;}"
\A1;6'-2{\H0.750000x;\S1#2;}"
\A1;1'-10{\H0.750000x;\S3#4;}"
\A1;2'-0"
\A1;2'-0"
\A1;4'-1"
\A1;4'-2"
\A1;6'-7{\H0.750000x;\S1#2;}"\A1;1'-10"\A1;1'-3{\H0.750000x;\S1#2;}"\A1;2'-9"
\A1;5'-9{\H0.750000x;\S1#2;}"
\A1;2'-0"FIRST FLOOR ELECTRICAL PLAN1/4" = 1'-0"
SFAN/LIGHT, VENT \PTO EXT.
RWP\PGFI
3S
220V
GFI
WP/GFIS3S
R
TO LIGHT ABOVE
S
SSGFI
FAN, VENT TO EXT.
GFI GFI
S
GFI
S
SFAN, VENT \PTO EXT.
SSS
RS
S
S
3S
R 3S3S
S
S
R RR
R RR
3S
3S3S
R
3S
3S
TO LIGHT ABOVE
3S
3S
3S
R
R
R
TV
TV
PH S/C
GFIS
RR
S3
S
GFI
GDOGDO
3S
R
S
R
WP/GFI
S R
R
S
DWGFISDISPS
DED.
GFI
GFI
GFI GFIGFIGFIGFIGFI
DED.
DED.
PHR
09/04/20