Loading...
HomeMy WebLinkAboutA101 FLOOR PLAN1. UNLESS OTHERWISE NOTED OR KEYED ON FLOOR PLAN, ALL NEW WALLS TO BE TYPE F3S. 2. CLEAN EXISTING EXTERIOR WINDOW BLINDS. REPAIR DAMAGED BLINDS WITH NEW TO MATCH BUILDING STANDARD. 3. PROVIDE BRACING AND FIRE-TREATED BLOCKING AS REQUIRED IN WALLS SUPPORTING CASEWORK, TACKBOARDS/MARKERBOARDS, RESTROOM ACCESSORIES, EQUIPMENT, OR ANY OTHER MISC. ITEM REQUIRING ADDITIONAL SUPPORT. 4. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 5. WHERE PLAN INDICATES EXPOSED DECK AT EXTERIOR WALLS, CONTRACTOR TO INCLUDE PROVIDING, INSTALLING, AND FINISHING THE DRYWALL ABOVE THE WINDOW HEADER AT THE EXTERIOR PERIMETER WALLS AS REQUIRED. 6. PROVIDE PLYWOOD BLOCKING BEFORE DRYWALL INSTALLATION IN ALL OFFICES FOR 4' X 6' WALL MOUNTED GLASS BOARDS. GLASS BOARDS TO BE INSTALLED AT 60" A.F.F. TO CENTER UNLESS NOTED OTHERWISE. CONFIRM LOCATIONS AND INSTALL HEIGHT WITH TENANT PRIOR TO INSTALLATION. 7. ALL APPLIANCES TO BE PROVIDED BY TENANT. APPLIANCES FOR BASIS OF DESIGN ONLY, TENANT TO CONFIRM AND COORDINATE FINAL APPLIANCE SELECTIONS. GENERAL NOTES KEYED NOTES ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. REFRENCE A004 FOR WALL TYPE DESCRIPTION. NOT ALL WALL TYPES LISTED ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. WALL TYPES B6S B6S OFFICE 205 OFFICE 206 RICH 207 OFFICE 208 OFFICE 209 OFFICE 210 OFFICE 211 OFFICE 212 OFFICE 213 GENE 214 HUDDLE 215 FILES/IT/STRG. 217 CONFERENCE 219 BREAK/COPY 221 RECEPTION 200 OFFICE 202 OFFICE 201 COPY 204 205206207208 201 202200 209 210 211 219212 213 217215 214 1/A5003/A500A500 5 4 4 3 2 FE1 A3S A3S A3S A3S A3S A3S A3S A3S A3S A3S A3S A3S A3S A3S 11/A500 10/A5002/A5004/A50010/A500LEGEND NEW CONSTRUCTION EXISTING TO REMAIN X1 DOOR AND FRAME (SEE DOOR SCHEDULE) NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. DOOR AND FRAME WALLWALL AREA NOT IN CONTRACT AREA OF WORK PLUMBING RISER DIAGRAM TYPICAL ALL SINGLE LOCATIONS NOT TO SCALE MA I N BL D G . W A STE 2" W A S T E TO C.O.2" V.SINK MAIN BLDG. VENT 2" VENT TO [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502020.19007.22.2020BWSB & BDSTRATEGIC CAPITAL PARTNERSINDIANAPOLIS, INDIANA 46240280 E 96TH STREET, SUITE 250A101 FLOOR PLAN 1 PROVIDE NEW SEMI-RECESSED FIRE EXTINGUISHER CABINETS.WHERE FIRE EXTINGUISHERS ARE SHOWN ON EXISTING WALLS, PROVIDE WALL HUNG UNITS. PLACEMENT IS FOR GENERAL REFERENCE. ALL EXTINGUISHERS SHALL BE PLACED IN ACCORDANCE WITH NFPA 10. 2 PROVIDE WATER LINE FOR WATER COOLER AND REFRIGERATOR. CONFIRM LOCATION WITH TENANT. 3 PROVIDE SINGLE BOWL STAINLESS STEEL UNDERMOUNT SINK AND FAUCET. PROVIDE GARBAGE DISPOSAL, LIGHT COMMERCIAL MODEL. PROVIDE PUSH BUTTON ON/OFF AT SINK/COUNTER FOR GARBAGE DISPOSAL IN LIEU OF SWITCH. SINK- ELKAY, CROSSTOWN #ECTRU24179R (STAINLESS STEEL) FAUCET- MOEN SLEEK WITH MOTION SENSE WAVE SPOT RESISTENT STAINLESS KITCHEN FAUCET #7864EWSRS (OR EQUAL). 4 FIXED WALL MOUNTED TELEVISION SUPPLIED BY TENANT. CONTRACTOR INSTALLED. COORDINATE EXACT LOCATION WITH TENANT. 1/8" = 1'-0" FLOOR PLAN 1 REVISION SCHEDULEMARK DATE DESCRIPTION09/09/20