Loading...
HomeMy WebLinkAboutA110 DOOR SCHEDULESDOOR HARDWARE AFB AUTOMATIC FLUSH BOLT CH COAT HOOK CR CARD READER BY TENANT (N.I.C.) CL CLOSER DB DEADBOLT DL DUMMY LEVER ES ELECTRIC STRIKE BY TENANT (N.I.C.) H HOLD OPEN KS KICK STOP KF KEY FOB KP KICK PLATE KS KICK STOP ML MAGNETIC LOCK OL OFFICE LOCKSET PH PANIC HARDWARE PL PRIVACY LOCKSET PP PUSH/PULL PS PASSAGE LATCHSET PV PIVOT HINGE RL ROLLER LATCHES SL STOREROOM LOCKSET TS TOP STRIKES DOOR FRAME 1. CONTRACTOR TO VERIFY THAT NO HOLES/OPENINGS ARE IN EXISTING DOOR DUE TO HARDWARE CHANGES. IF HOLES ARE PRESENT THAT WILL NOT BE FILLED BY NEW HARDWARE, CONTRACTORS TO CONTACT PARALLEL DESIGN GROUP TO CONFIRM ON HOW TO MOVE FORWARD. 2. PROVIDE NEW BUILDING STANDARD DOORS MATCHING EXISTING VENEER AS REQUIRED. STAIN NEW DOORS. PRE- MACHINE NEW DOORS FOR CYLINDRICAL LOCKSETS. 3. PROVIDE NEW HARDWARE ON NEW DOORS. REUSE EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE. FOR NEW DOOR HARDWARE, PROVIDE BUILDING STANDARD. PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND LATCHSETS. 4. PROVIDE NEW FRAMES AS REQUIRED. 5. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL CORNERS UNLESS OTHERWISE NOTED ON PLAN. 6. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND LOCKSETS. 7. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES. ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS. 8. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS: · 7'-0" HT. TO HAVE 3 HINGES · GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES · FINISH TO MATCH HARDWARE SET 9. PROVIDE 1 SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE NOTED. 10. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL STOP. 11. PROVIDE COAT HOOK ON THE BACK OF ALL RESTROOM AND OFFICE DOORS UNLESS NOTED OTHERWISE. DOOR TYPES FRAME TYPES 1/4" TEMPERED GLASS F1 F2 F3 D1D2 2"SEE SCHEDULE 2"SEE SCHED.2" 2' - 0" 2" 2" SEE SCHEDULE 2" SEE SCHED. 2"SEE SCHEDULESEE SCHED.SEE SCHEDULESEE SCHED. SEE SCHEDULESEE SCHED. F4 SEE SCHED. SEE SCHEDULEEQ. EQ. EQ. 3/8" TEMPERED GLASS, BUTT-JOINTED WITH CLEAR POLYMER STRIPS U CHANNEL FINISH TBD U CHANNEL FINISH TBD [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502020.19007.22.2020BWSB & BDSTRATEGIC CAPITAL PARTNERSINDIANAPOLIS, INDIANA 46240280 E 96TH STREET, SUITE 250A110 DOOR SCHEDULES DOOR SCHEDULE DOOR NUMBER ROOM PAIR POWER REQUIRED DOOR FRAME COMMENTSWIDTH x HEIGHT x THICKNESS TYPE MATERIAL FINISH TYPE MATERIAL FINISH HARDWARE SET 200 RECEPTION Yes Yes 3' - 0" x 8' - 0" x1/2" D2 GLASS - F3 DRYWALL - CL,CR,ML,PP 1 201 OFFICE 3' - 0" x 8' - 0" x1 3/4" D1 SOLID CORE WOOD BLDG. STD. F2 BUILDING STANDARD TBD PS 202 OFFICE 3' - 0" x 8' - 0" x1 3/4" D1 SOLID CORE WOOD BLDG. STD. F2 BUILDING STANDARD TBD PS 205 OFFICE 3' - 0" x 8' - 0" x1 3/4" D1 SOLID CORE WOOD BLDG. STD. F2 BUILDING STANDARD TBD PS 206 OFFICE 3' - 0" x 8' - 0" x1 3/4" D1 SOLID CORE WOOD BLDG. STD. F2 BUILDING STANDARD TBD PS 207 RICH 3' - 0" x 8' - 0" x1 3/4" D1 SOLID CORE WOOD BLDG. STD. F1 BUILDING STANDARD TBD PS 208 OFFICE 3' - 0" x 8' - 0" x1 3/4" D1 SOLID CORE WOOD BLDG. STD. F2 BUILDING STANDARD TBD PS 209 OFFICE 3' - 0" x 8' - 0" x1 3/4" D1 SOLID CORE WOOD BLDG. STD. F2 BUILDING STANDARD TBD PS 210 OFFICE 3' - 0" x 8' - 0" x1 3/4" D1 SOLID CORE WOOD BLDG. STD. F2 BUILDING STANDARD TBD PS 211 OFFICE 3' - 0" x 8' - 0" x1 3/4" D1 SOLID CORE WOOD BLDG. STD. F2 BUILDING STANDARD TBD PS 212 OFFICE 3' - 0" x 8' - 0" x1 3/4" D1 SOLID CORE WOOD BLDG. STD. F2 BUILDING STANDARD TBD PS 213 OFFICE 3' - 0" x 8' - 0" x1 3/4" D1 SOLID CORE WOOD BLDG. STD. F2 BUILDING STANDARD TBD PS 214 GENE 3' - 0" x 8' - 0" x1 3/4" D1 SOLID CORE WOOD BLDG. STD. F2 BUILDING STANDARD TBD PS 215 HUDDLE 3' - 0" x 8' - 0" x1 3/4" D1 SOLID CORE WOOD BLDG. STD. F2 BUILDING STANDARD TBD PS 217 FILES/IT/STRG. 3' - 0" x 8' - 0" x1 3/4" D1 SOLID CORE WOOD BLDG. STD. F1 BUILDING STANDARD TBD PS 219 CONFERENCE 3' - 0" x 8' - 0" x1/2" D2 GLASS - F4 -- -- CL,HO,PP 1 REMARKS 1. CONFIRM PUSH/PULL HARDWARE (BOTH SIDES OF DOOR) WITH TENANT, LANDLORD AND DESIGNER. MFG: ROCKWOOD STYLE: FINISH: SIZE:REVISION SCHEDULEMARK DATE DESCRIPTION09/09/20