HomeMy WebLinkAboutA201 REFLECTED CEILING PLAND DDD DD1. REUSE EXISTING CEILING GRID UNLESS OTHERWISE NOTED. EXISTING GRID IS 2'x2' AT 9'-0" A.F.F. REPAIR ANY DAMAGED GRID AND PAINT GRID WHITE AS REQUIRED. 2. REPLACE ALL DAMAGED OR DIRTY CEILING TILES WITH NEW TO MATCH EXISTING. PROVIDE LIKE TILES IN INDIVIDUAL ROOMS TO CREATE UNIFORM LOOK. 3. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE COVERPLATE. 4. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 5. LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE ONLY AND ARE TO BE PROVIDED BY LIGHTING CONSULTANT AND ELECTRICIAN. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT LAY-OUT AND TOTAL WATTAGE MEETS ASHRAE 90.1 STANDARDS AND LIGHT LEVELS ARE APPROPRIATE FOR THE USE OF EACH SPACE. OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 6. UNLESS NOTED OTHERWISE ALL NEW SWITCHES MUST BE AN OCCUPANCY SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 7. CAN LIGHT FIXTURES TO BE SWITCHED SEPARATELY AND HAVE DIMMERS. 8. ALL EXPOSED ACOUSTICAL CEILING TILE EDGES TO BE FINISHED WITH 4" WHITE AXIOM TRIM UNLESS NOTED OTHERWISE. 9. ALL DEVICES AND COVERS TO BE WHITE. 10. ALL EXPOSED DECK (INCLUDING SPRINKLERS PIPES) TO BE PAINTED PT1 UNLESS NOTED OTHERWISE. 11. ALL DRYWALL CEILINGS TO BE PAINTED PT1 UNLESS NOTED OTHERWISE. 12. PAINT 10' BEYOND PERIMETER OF CEILINGS WHERE OPEN DECK IS EXPOSED BEYOND AND WHERE IT TRANSITIONS FROM OPEN DECK TO ACOUSTICAL TILE. PAINT EXPOSED DECK WITH DRYFALL PAINT. 13. WHERE PLAN INDICATES EXPOSED DECK AT EXTERIOR WALLS, CONTRACTOR TO INCLUDE PROVIDING, INSTALLING, AND FINISHING THE DRYWALL ABOVE THE WINDOW HEADER AT THE EXTERIOR PERIMETER WALLS AS REQUIRED. 14. DECORATIVE FIXTURE(S) SPECIFIED ARE TO BE PURCHASED THRU LOCAL COMMERCIAL VENDOR TO INSURE COMMERICAL WARRANTIES. PURCHASING FROM OTHER VENDORS OR AVENUES IS AT THE SUPPLIER'S / EC'S RISK NOT, THE PARALLEL DESIGN GROUP'S, OWNER'S, OR TENANT'S. 15. IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. GENERAL NOTESLEGEND MECHANICAL NOTES KEYED NOTES 1. SCOPE INTENT IS FOR EXISTNG MECHANICAL SYSTEMS TO REMAIN. EXISTING FLEX DUCT AND DIFFUSERS BEING RELOCATED AS NECESSARY PER WALL LAYOUT. NO MAIN DUCTWORK BEING RELOCATED. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR NOTIFYING APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED. 2. DIFFUSER LOCATIONS ARE SHOWN ON PLAN FOR REFERENCE ONLY, CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS REQUIRED BY CODE. 3. FIRE STOP ANY EXISTING DECK PENETRATIONS AS REQUIRED. 4. LOCATE THERMOSTATS WHERE APPROPRIATE PER MECHANICAL DESIGN. ALL THERMOSTATS TO HAVE LED DISPLAY WITH LOCKOUT CAPABILITY AND LOCK BOX. VERIFY LOCATIONS WITH TENANT BEFORE INSTALLING. 5. WHERE EXPOSED DECK IS SHOWN, VERIFY WITH DESIGNER AND TENANT IF DUCT WORK SHOULD BE SPIRAL DUCT. DIFFUSER, LAY-IN, 2'x2' DIFFUSER, LAY-IN, 1'x4' DIFFUSER, LAY-IN, 4"X4' NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. X X' -X" CEILING TYPE CEILING HEIGHT 2' x 2' ACOUSTICAL CEILING (EXISTING TO REMAIN) MFG: ARMSTRONG TYPE: DUNE EXPOSED DECK-PAINT PT1, DRY WALL PAINT A INDICATES NIGHT LIGHT LOCATIONNL EXIT LIGHT FIXTURE EMERGENCY LIGHT FIXTURE NEW CEILING GRID, SUSPENDED, 2'x2' NEW GYPSUM BOARD CEILING EXISTING CEILING GRID, SUSPENDED, 2'x2' LIGHT SWITCH LIGHT SWITCH, 3-WAY LIGHT SWITCH, 4-WAY LIGHT SWITCH, DIMMER LIGHT CIRCUIT 3 4 D EL EXISTING GYPSUM BOARD CEILING LIGHT FIXTURE, WHITE LUMENWERX VIA3 LINEAR WALL WASH LED, LENGTHS VARY; SEE SIZES INDICATED ON PLAN D1 LIGHT FIXTURE, PENDANT FIXTURE, LED MFG: TECH LIGHTING MFG ID: 700FJPPRSS-LEDS930 MODEL: TLG67148 FINISH: SATIN NICKEL P1 LIGHT FIXTURE, 24" DIAMETER PENDANT FIXTURE MFG: ET2 MFG ID: E31256-BBK MODEL: 23.5" ET2813708 FINISH: BRUSHED BLACK P2 LIGHT FIXTURE, 2'X4', LED MFG: COOPER LIGHTING STYLE: 2X4 METALUX LED LIGHT FIXTURE LED UNDER CABINET LIGHTINGL1 LIGHT FIXTURE, WHITE LUMENWERX VIA3 LINEAR SUSPENDED LED DIRECT/INDIRECT, LENGTHS VARY; SEE SIZES INDICATED ON PLAN D2 B LIGHT FIXTURE WALL SCONCE MFG: BETACALCO MODEL: STRIPE FINISH: POWDER COATED L2 D2 - 12'-0" D2 - 12'-0" P1 P2 P2 D1 - 18'-0"D1 - 18'-0" P1 P2 D2 -7' -0"D2 -7'-0"D2 -7' -0"D2 -7'-0"D2 -7' -0"D2 -7'-0"1 1 1 1 D2 - 12'-0" L1 L1L1EL EL ELL2 L2 L2 2 AREA NOT IN CONTRACT AREA OF WORK MECHANICAL DIFFUSER RELOCATION1NOT TO SCALE *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION RELOCATE DIFFUSERS AND FLEX DUCT IF REQUIRED VAV/ HEAT PUMPEXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502020.19007.22.2020BWSB & BDSTRATEGIC CAPITAL PARTNERSINDIANAPOLIS, INDIANA 46240280 E 96TH STREET, SUITE 250A201 REFLECTED CEILING PLAN 1 PAINT DECK AND DUCT WORK WHITE. 2 PROVIDE SOUND BOOT WITH 2'X2', LAY-IN DIFFUSER. 1/8" = 1'-0" REFLECTED CEILING PLAN 1 REVISION SCHEDULEMARK DATE DESCRIPTION09/09/20