Loading...
HomeMy WebLinkAboutA001 LIFE SAFETY PLANALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING • BUILDING CODE 2014 INDIANA BUILDING CODE (2012 IBC WITH STATE AMENDMENTS) • STRUCTURAL CODE 2008 INDIANA BUILDING (2006 IBC, ASCE-7-2005) • PLUMBING CODE 2012 INDIANA PLUMBING CODE • MECHANICAL CODE 2014 INDIANA MECHANICAL CODE (2012 IMC WITH STATE AMENDMENTS) • ELECTRICAL CODE 2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMENDMENTS) • FIRE/LIFE SAFETY CODE 2014 INDIANA FIRE CODE (2012 IFC WITH STATE AMENDMENTS) • ACCESSIBILITY CODE 2014 INDIANA BUILDING CODE, CH11-ACCESSIBILITY, ANSI A-117.1 STANDARD, ADA ACCESSIBILITY GUIDELINES - 2009 EDITION • ENERGY CODE 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007) WITH INDIANA AMMENDMENTS • GENERAL ADMINISTRATIVE RULES 2ND EDITION. CODE SUMMARY GENERAL NOTES 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). 3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP, IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 6. REFER TO SHEET A100 FOR WALL TYPE AND CONSTRUCTION DETAILS 7. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. APPLICABLE BUILDING CODES OCCUPANCY LOADS EXISTING ELECTRICAL PANEL LOCATION EXISTING EXIT -BUILDING EXIT LOCATION FIRE EXTINGUISHER EXIT SIGNAGE EMERGENCY LIGHTING NIGHT LIGHT/EMERGENCY LIGHTING, REFERENCE A200 FOR LOCATION. LEGEND EX FE EL NL EP ASSEMBLY OCCUPANY REGION(S) STORAGE AREA REGION(S) AREA NOT IN CONTRACT AREA OF WORK COMMON PATH OF EGRESS EXIT ACCESS TRAVEL DISTANCE EX EX EL EL ELFE EP 170 SF HUDDLE 215 175 SF FILES/IT/STRG. 217 379 SF CONFERENCE 219 OFFICE 213 OFFICE 212 OFFICE 211 OFFICE 210 OFFICE 209 OFFICE 208 RICH 207 OFFICE 206 OFFICE 205 OFFICE 202 OFFICE 201 COPY 204 RECEPTION 200 BREAK/COPY 221 GENE 214 COMMON PATH OF EGRESS = 96'EXIT ACCESS TRAVEL = 197'EXIT ACCESS TRAVEL = 129'[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502020.19007.22.2020BWSB & BDSTRATEGIC CAPITAL PARTNERSINDIANAPOLIS, INDIANA 46240280 E 96TH STREET, SUITE 250A001 LIFE SAFETY PLAN CHANGE OF OCCUPANCY CLASS: No SPRINKLER SYSTEM (YES/NO): Yes TOTAL BUILDING SQ FT: 89,178 SCOPE OF WORK: OFFICE SPACE BUILD-OUT REMODEL TO PREVIOUSLY BUILT-OUT OFFICE. FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS: No 3/32" = 1'-0" LIFE SAFETY PLAN1 OCCUPANCY: (B)USINESS EXIT TRAVEL DISTANCE (FEET): 300 COMMON TRAVEL PATH OF EGRESS (FEET): 100 USABLE AREA SQ FT: 3970 TOTAL AREA ON FLOOR: 29,726 OCC KEY Space Type OCC Classification Area SF PER OCCUPANT OCCUPANT LOAD (B)USINESS IBC Business areas 3,796 SF 100 38.0 (B)USINESS IBC Mercantile - Storage, stock, shipping areas 175 SF 300 0.6 Total Project Area / Total Project Occupant Load 3,970 SF 38.5 NUMBER OF REQUIRED EXITS: 1 REVISION SCHEDULEMARK DATE DESCRIPTION09/09/20