HomeMy WebLinkAboutS001UPGR REFER TO DETAIL SHEET D2.0 FOR GARAGE SLAB REBAR REQUIREMENT NOTE: 08 D2.1 D B C 08 D2.1 3 A 08 D2.1 WP01 A1.14'-612"TO ℄ SINK27"x27"x12" C.I.P. CONCRETE COLUMN FOOTING - HOLD T/FT'G. DOWN 3 12" FROM T/SLAB 33"x33"x15" C.I.P. CONCRETE COLUMN FOOTING - HOLD T/FT'G. DOWN 3 12" FROM T/SLAB VERTICAL CONTROL JOINT -DTL. 01/D2.1 12'-578"TO℄ TOILET DRAIN10'-10" 3'-1112" TO NOSING 512"10" GROUNDING ROD - PREF. LOCATION - KY ONLY1'-0" FURNACE HOLD T/ GARAGE SLAB DOWN 1" FROM T/ FDN. & SLOPE TO O.H. DOOR 3"Ø, 11 Ga. ADJUSTABLE STEEL COLUMN 9'-838"TO℄ SHOWER DRAINROUGH-IN FULL BATH 9'-914" 31'-712" 16'-2"9'-914"2x4 NOTCH IN WALL SLOPE 3" FROM REAR WALL TOWARD GARAGE DOOR DETAIL - 10/D2.1 9'-8" LINE OF LANDING ABOVE 10"18'-6" 10"10"19'-5"17'-512"TO ℄ STEEL BEAM8" x 20" C.I.P. CONCRETE FOOTINGS 8" x 20" C.I.P. CONCRETE FOOTINGS-HOLD T/ WINDOW 16"BELOW T/ FDN. WALLEGRESS WINDOW WELL- w/ DRAIN5040 SL19'-012" 10" 13'-512" TO ℄ STEEL COLUMN 19'-4" TO NOSING (ABOVE) 10"11'-4" TO ℄ STEEL COLUMN W8 x 18 STEEL BEAM W8 x 18 STEEL BEAM 3"Ø, 11 Ga. ADJUSTABLE STEEL COLUMN 42" x 42" x 18" COLUMN FOOTING - HOLD DOWN 3 12" 24" x 24" x 12" COLUMN FOOTING - HOLD DOWN 3 12"10" x 8" x 8 18" BEAM LEDGE 3'-5"4'-10"10" 1'-412"10" 14'-112" TO ℄ FLOOR DRAIN 10" C.I.P. CONCRETE FOUNDATION WALLS 10" C.I.P. CONCRETE FOUNDATION WALLS10"7'-612"TO ℄ STEEL BEAMCONTROL JOINT 3" Ø STEEL COLUMN 17'-2"℄ STEEL BEAM11'-4" 19'-712" 10" 3'-5" 10"CONTROL JOINTBEARING WALL - DBL. 2x4 STUDS @ 19.2" o.c. - ALIGN w/ JOIST's ABOVE - NO DRYWALL BELOW JOIST - ATTACH GUARDRAILS TO STUDS 110V SMOKE DETECTOR TO SWITCH ABOVE RADON PIPE - DETAIL 03/D2.1 WH GUARDRAIL HANDRAIL - ONE SIDE 3'-7" 12'-0" BEARING WALLCONTROL JOINTW8 x 18 STEEL BEAM 9'-8" ℄ STEEL COLUMN BASEMENT UNEXCAVATED 9'-0" FOUNDATION 8"d. x 18"w. C.I.P CONCRETE FOOTING - SEE DTL. 04/D2.1 19'-912" 10" 10" 3"Ø SCHEDULE 40 STEEL COLUMN 8" 4'-8"HOLD T/ WALL DOWN 1 12" FROM T/ FOUNDATION CONTROL JOINT LINE OF PORCH ABOVE #4 RE-BAR @ 18" o.c. - FRONT TO BACK 8" 33'-912"5'-4"FULL HEIGHT FDN WALL6'-0" FULL HEIGHT FDN WALL 28'-512" STEP FOOTING TO MATCH GARAGE HEIGHT EJECTOR LOC. TBD IN FIELD WATER SOFTENER LOCATION DEDICATED OUTLET FOR SUMPSUMP LOC. TBD IN FIELD DEDICATED OUTLET FOR SUMP NOTE: MINIMUM 6 12" DEEP BRICK CURBING AS REQUIRED PER COMMUNITY FEATURES - STEP LOCATIONS AND DEPTH PER STANDARDS AND GUIDELINES ON DTL. SHT. D2.3 18'-0" 16'-6" 20'-83 4" 35'-0" 12'-8" 8'-11" 56'-7"29'-10" 6'-512"16'-2" 36'-312" 7'-11"60'-412"33'-1114" 16'-3" 6'-43 4" 56'-7"6" 15'-0" 6"2'-0" 2'-512" 16'-0" 1'-4" 9'-0" 21'-8" 7'-11"60'-412"Xref ..\..\Constructs\Solved\Finished Basement - solved.dwg WILLIAML.KAUFH O L Z A RCHITECTFOUNDATION DIAGONALS A B A 0" A 36'-3 1/2" B 36'-3 1/2" B 0" C 67'-2 21/32" C 56'-7" D 58'-3 31/32" D 75'-9 3/4" TALLYNS RIDGEREASON FOR PLOT: PLOT DATE:Job No. Sheet No.IN HOMESITE NO.OFFICE REVIEW:MASTER BY: DATE: C DATE: 3940 Olympic Blvd, suite 100Erlanger, KY 41018PH: (859) 341-4709FIELD SPEC HOTLINE: (859) 341-4709COPYRIGHT ALL RIGHTS RESERVEDFISCHER HOMES, Inc.JOB INFO:DATE: PERMIT: SIGN-OFF: CONSTRUCTION:REVISION:REVISION:REVISION:REVISION:HOME TYPE:PLAN:8/14/2020 3:08 PM# TLR010050000TLR010050000#2 * MARKET HOME *14397 TALLYN WAYSTANTON57-460-STANTON AMERICAN CLASSIC WITH BRICKCARMEL, IN5 05/2017------------------------------------------------Masterpiecefieldspecchange@fischerhomes.comREVISED BY:-------- ----SAPPHIRE TRADE SUPPORTsapphiretradepartners@fischerhomes.comFischer Homes Indianapolis II, LLCA2.0 SCALE = 1'-0" FOUNDATION PLAN 1/4"01 FOUNDATION PLAN NOTE: 1. FOUNDATION WALLS SHADED AS TO BE SET AT T/ FDN ELEVATION PER PLOT PLAN 2. FOUNDATION WALLS UNSHADED TO BE DROPPED AS NOTED ON FOUNDATION PLAN FLOOR PLAN NOTE: 1. ALL EXTERIOR WALLS SHALL BE FRAMED @ 16" o.c. 2. INTERIOR WALLS SHADED AS INDICATES INTERIOR LOAD BEARING WALL TO BE FRAMED @ 19.2" o.c. (UNLESS OTHERWISE NOTED ON PLAN) - ALIGN JOISTS w/ STUDS. 3. INTERIOR WALLS SHADED AS INDICATES INTERIOR WALLS TO BE FRAMED @ 16" o.c. 09/10/20