Loading...
HomeMy WebLinkAboutALB29 S200.0 Second Floor Framing PlanOWNER'S SUITE OWNER'S BATH W.I.C. BEDROOM #2 W.I.C. BEDROOM #3 LAUNDRY OPEN TO BELOW BEDROOM #4 W.I.C. BATH#3 W.I.C. (TYP.) 2'-6" TRAY CLG. 9'1" CLG. 10'1" CLG. BONUS ROOM 10'-3 1/8" CLG. 45'-3" 12'-0" 12'-8 1/2" 20'-6 1/2" 45'-3" 7'-0" 8'-11"2'4"2'4"2'0"2'6"2'4"2'4"2'4"2'4"2'6"2'8"2'6"3060 S/H 3060 S/H 3060 S/H 3060 S/H 3060 S/H12'-0 1/2" 5'-10"17'-9"8'-1 1/2"5 1/2"4'-5" 7'-0" 3'-7"9'-7 1/2" 5'-4 1/2" 4"3'-2" 11'-1" 2'-0" 5'-3"2'-0" 3'-10" 14'-0 1/2"5'-7 1/2"3'-8" 8'-1 1/2" 2'-10"5'-0" 5'-0" 12'-2"3'-10" 4'-11" 2'-9" 6'-4 1/2"2'-8 1/2" 6'-1 1/2" 2'-10" 5 1/2" 7'-9 1/2" 1'-11 1/2" 3'-10 1/2" 1'-11 1/2" 7'-9 1/2"5 1/2" 3'-1"15'-8 1/2"12'-1 1/2"11'-6 1/2"14'-2"4'-1" 1'-7" 7 1/2"5'-0"2'-10" 5'-8 1/2" 5'-2" 3'-1" 3 J&J BATH 2'-4" 9'-8" 6'-4" 6'-4 1/2"52'-3"46'-3"6'-0"2040 FIXED 3060 S/H14'-1" 5 1/2"3'-7"52'-3"28'-1 1/2"13'-5" 15'-11" 2040 FIXED2'4"2'4"2'4"2 16 12'-2"13'-9"3'-8"6'-1"3'-6" 3'-1" 7'-9" 3'-3" 4 1/2" 3'-1" 1'-10" 5'-3 1/2" 6'-7" 3'-10 1/2" 8'-0" 1 3 3 4 20'-3" 3'-10" 15'-0 1/2" 2'6"3'0"3'-7 1/2" 2'-0" 14'-0 1/2" 5'-2 1/2" 2'-3 1/2" 2'-3 1/2"6'-7" 46'-3"6'-0" 11'-1" 7'-0 1/2" 14 5'-2 1/2" 6 6 3'-7" 7'-8" 55 1 1 3'-8" 12'-8"3060 S/H 3060 S/H 6"6" 6"19'-0" 27'-3"3060 S/H3'-7" MUDBED 2'-7 1/2" RESIDENCE FOR:Sheet InformationHouse Name: Series: Plan No.: Job Number: Drawing Date: Coord Name: Coord Phone: Drawing Scale: 1/8" = 1'0" Drawn By: Copyright © 2019, (2019) The Drees Company. All Rights Reserved. Space for Architect Seal 900 East 96th Street, Suite 100, Indianapolis, IN 46240 Phone: [317] 347-7300 MARKET 3564 PERCIVAL DRIVE ALBANY PLACE ALB-0029-00 7/7/2020 M. HYATT SERIES_NM PLAN_NM 2.02F Elevation "B" Second Floor Framing Plan 859.578.4290 the LAYTON LJR General Notes: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DO NOT LOCATE TRUSS ABOVE PLUMBING WALL. TOP OF OPENING AT 8'-1" A.F.F. 36" HIGH WALL 1. REFER TO SHEET 0N.1 FOR GENERAL NOTES. 2. ALL SECOND FLOOR CEILINGS TO BE 9'-1" ABOVE SUBFLOOR UNLESS OTHERWISE NOTED 3. FRAME TOP OF ALL WINDOWS AT 1'-0 1/4" BELOW TOP OF PLATE UNLESS OTHERWISE NOTED. 4. ALL DROPPED, INTERIOR HEADERS (FALSE AND BEARING) ARE DROPPED 1'-0" FROM CEILING UNLESS CALCULATIONS REQUIRE LARGER HEADERS. 5. REFER TO SELECTION SHEETS FOR FLOORING MATERIAL PRIOR TO CONSTRUCTING STAIRS TO DETERMINE RISER HEIGHTS. 6. REFER TO SHEET 2.02S FOR STRUCTURAL INFORMATION. Key Notes: 4-1/2"H. CURB AT SHOWER BY PLUMBING CONTRACTOR 22-1/2"x32" ATTIC ACCESS FLOOR TO BE LOWERED 1'-2 1/8" BELOW MAIN SECOND FLOOR SUBFLOOR -PROVIDE (2) RISERS @ 7-1/16" HIGH EA SLOPED WALL WITH STAIR STRINGER (RAILING) 2x6 BALLOON FRAMED WALL REISSUED: 07/21/2020 09/10/20