Loading...
HomeMy WebLinkAboutALB10 Energy ReportIndiana 2�2� Perfarman�e �ompliance Praperty 14310 MARSDALE PLACE CARMEL, IN 4fi074 Madel: LANGDON 65T Ba5 9PL R Community: ALBANY PLACE 909aREIN ALBANY PLACE 1431D MARSDALE PLACE-LANGaON Performance-based compliance passes by 1.4°�6 Air Leakage Testing Area-weighted average fenestration SHGC Area-weighted a�erage fenestration Ll-Factor Annual Energy Cost Design Heating Cooling Water Heating Mechanical Ventilatian 5ubTotal - Used to determine �omplian�e Lights & Appliances wlout Ventilation �nsite generation Total Indiana 2020 Performance $1,524 $242 $219 $32 $2,�17 $1,0�1 $0 $3,�88 Inspe�tion 5tatus Results are projected This report is based an a proposed design and does not confirm field enforcement of design elements. Requirements � � � � � � � � 11D5 11 D2.4.12 11 D2.5 11 D2.5 11D4.1 Lighting Equipment Efficiency f�landatory Checklist �'�andatory code requirements that are not checked by Ekotrope must be met. 11D3.6 Mechanical Ventilation Rate 1103.6.1 hlechanical Ventilation Efficacy a Build Home 5enrices ENVIRCIN�IhENTSFOR J,�, f� As aesigned $1,489 $251 $219 $32 $1,99� $1,a71 $0 $3,D61 Air sealing is 5.00 AGH at 50 Pa. It must not exceed 5.0� ACH at 5a Pa. Design ex�eeds requirements fvr Indiana 202� Perfvrman�e compliance hy 1.4°Io. As a 3rd party extension of the code jurisdi�tion utilizing these reports, I certify that this energy code complian�e document has been created in accordan�e with the requirements of Chapter 4 of the adopted Intemational Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certiTy that the building design des�ribed herein is consistent with the building plans, specifications, and other �al�ulations submitted �tiith the permit application. If rating is Confirmed, I �ertiTy that the address referenced abo�e has been inspected.+tested and that the mandatory pro�isions of the IECC have 6een installed to meet or ex�eed the intent of the IECC or will be verified as such by another party. Name Organizatian ❑rganixatian TopBuild Home 5ervi�es, I Eric Bjerre 6uilder aREES HDMES Eric 8jerre TapBuild Home 5eruices. In� Signature: ��'�'G ���� ❑igitally sig��ed: 7;'8i2fl at 1fl:32 AM Ekotrope RATER - Vers�on 3.2.3.2479 Indiana 202� Perforinance compliance results calculated using Ekotrope RATER's energ}� and code compliance algorithm, including appropriate amendments. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are 6ased on data entered 6y Ekotrope users. Ekotrope disclaims all lia6ility for the information shown on this report. Energy �ode Inspectian Checklist Property ❑rganixatian 14310 MARSDALE PLACE TopBuild Home 5ervi�es, I CARMEL, IN 4fi074 Eric Bjerre Madel: LANGDON 65T Ba5 9PL R Community: ALBANY PLACE 6uilder aREES HDMES 909aREIN ALBANY PLACE 1431D MARSDALE PLACE-LANGaON �eneral Building Infvrmatian Canditioned Area �sq ft} Canditioned Valume (�ubic ft) Insulated Shell Area (sq ft� 5,9�6 56,271 1 a,193.96 Inspe�tion 5tatus Results are projected a Build Home 5enrices ENVIRCIN�IhENTSFOR J,�, f� The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will �hange in the field frorn what has been modeled. The inspection pro�ess should identify any �hanges and ensure that the home cantinues to meet the applicable energy code. 51ab � Name: SLAB(2,016 s.f., 2D4 ft. exterior perirneter} R-0 perimeter insulation, R-� under slab insulatian. Framed Flvar � Name: FDA �35 s.f.) R-0 continuous insulation, R-30 cavity insulation Insulatian Grade: I � Name: FDG (289 s.f.} R-0 continuous insulation, R-30 cavity insulatian Insulation Grade: I Fvundatian Wall � Name: BGIN RM6 (Exterior Perimeter [ft]: 169.33, Height Abo�e Grade [ft]: 1, ❑epth 6elaw Grade [ft]: 6.8} R: 11.00 Feet from top af wall to tap of insulation: 0, Feet from top of wall to battom of insulatian: 4 � Name: BGIN GAR �Exterior Perimeter [ft]: 3�.67, Height Above Grade [ft]: 1, ❑epth 6elaw Grade [ft]: 6.8} R: 11.00 Feet from top af wall to top of insulation: 0, Feet from top of wall to bottam of insulatian: 4 Above �rade Wall � Name: AMB [2,6�8.22 s.f.y R-0 continuous insulation, R-15 cavity insulatian Insulation Grade: I Energy �ode Inspectian Checklist Property ❑rganixatian 14310 MARSDALE PLACE TopBuild Home 5ervi�es, I CARMEL, IN 4fi074 Eric Bjerre Madel: LANGDON 65T Ba5 9PL R Community: ALBANY PLACE 6uilder aREES HDMES 909aREIN ALBANY PLACE 1431D MARSDALE PLACE-LANGaON � Name: AMB 2iC6 (439.04 s.f.} R-0 continuous insulation, R-19 cavity insulatian Insulation Grade: I � Name: GAR (314.8 s.f.} R-a continuous insulation, R-15 cavity insulatian Insulation Grade: I � Name: ATT � 141 s.f. } R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Jaist � Name: AMB (336.G s.f.} R: 15.00 � Name: ATT �42 s.f.y R: 15.00 Ceiling 1 Ravf � Name: FLAT �2,241 s.f.} R-27 continuous insulatian, R-13 cavity insulation Insulation Grade: I � Name: SL�PEa (100.1 s.f.} R-25.�5 eontinuaus insulati�n, R-12.95 �avity insulatian Insulation Grade: I ❑paque Daar � Name: FR�NT (20 s.f.} U: 0.227 � Name: GARAGE (17.8 s.f.J U: 0.227 �lazing Inspe�tion 5tatus Results are projected a Build Home 5enrices ENVIRCIN�IhENTSFOR J,�, f� 2 Energy �ode Inspectian Checklist Property ❑rganixatian Inspe�tion 5tatus 14310 MARSDALE PLACE TopBuild Home 5ervi�es, I Results are projected CARMEL, IN 4fi074 Eric Bjerre Madel: LANGDON 65T Ba5 9PL R Community: ALBANY PLACE 6uilder aREES HDMES 909aREIN ALBANY PLACE 1431D MARSDALE PLACE-LANGaON � Name: BAGK B5T EGR (16 s.f.}, U: �.320, SHGC: 0.�, �rientatian: SDIJTH � Name: FR�NT RIGHT 1ST �10 s.f.y, lJ: 0.32�, SHGC: D.4, Drientatian: N�RTH � Name: FR�NT 1 ST (24 s.f.), U: 0.320, SHGC: 0.4, Drientatian: hIDRTH � Name: FR�NT LEFT 15T (10 s.f.}, U: D.320, SHGC: 0.4, �rientation: NDRTH � Name: FR�NT 1 ST (12 s.f.), U: 0.320, SHGC: 0.4, Drientation: IVDRTH � Name: FR�NT 1 ST (18 s.f.), U: 0.320, SHGC: 0.4, Orientatian: IVDRTH � Name: FR�NT 1 ST (18 s.f.), U: 0.320, SHGC: 0.4, Orientatian: IVDRTH � Name: FR�NT 1ST (4.� s.f.y, U: �.32Q, SHGC: 0.4, ❑rientation: NDRTH � Name: LEFT 15T (8 s.f.}, U: 0.320, SHGC: 0.4, Drientation: EAST � Name: BAGK 15T (36 s.f.J, U: 0.320, SHGC: 0.4, Drientation: S�UTH � Name: BAGK 15T 2X6 (36 s.f.}, U: D.320, SHGC: 0.4, �rientation: SDUTH � Name: BAGK 1STSGa (48 s.f.}, U: 0.320, SHGC: 0.4, Drientation: S�IJTH � Name: BAGK 1ST (24 s.f.), U: 0.320, SHGC: 0.4, Drientation: S�UTH � Name: BAGK 1 ST (8 s.f.}, U: 0.320, SHGC: 0.4, Drientation: S�IJTH � Name: RIGHT 1ST (6 s.f.}, U: D.32D, SHGC: 0.4, �rientatian: WEST � Name: FR�NT 2ND �22 s.f.}, lJ: 0.320, SHGC: 0.4, ❑rientation: N�RTH � Name: FR�NT 2ND �12 s.f.}, lJ: 0.320, SHGC: 0.4, ❑rientati�n: N�RTH a Build Home 5enrices ENVIRCIN�IhENTSFOR J,�, f� 3 Energy �ode Inspectian Checklist Property ❑rganixatian Inspe�tion 5tatus 14310 MARSDALE PLACE TopBuild Home 5ervi�es, I Results are projected CARMEL, IN 4fi074 Eric Bjerre Madel: LANGDON 65T Ba5 9PL R Community: ALBANY PLACE 6uilder aREES HDMES 909aREIN ALBANY PLACE 1431D MARSDALE PLACE-LANGaON � Name: FR�NT 2ND �8 s.f.y, lJ: 0.320, SHGC: D.4, ❑rientation: NDRTH � Name: LEFT �ND �30 s.f.}, U: 0.320, SHGC: �.4, ❑rientatian: EAST � Name: LEFT 21VD �16 s.f.}, U: 0.320, SHGC: �.4, ❑rientatian: EAST � Name: BAGK 2ND �16 s.f.}, U: 0.32a, SHGC: 0.�, ❑rientation: 50L1TH � Name: BAGK 2ND �36 s.f.}, U: 0.32a, SHGC: 0.4, ❑rientation: 50L1TH � Name: BAGK 2ND �15 s.f.}, U: 0.32a, SHGC: 0.�, ❑rientation: 50L1TH � � � � Name: BACK 2ND �15 s.f.}, U: 0.32a, SHGC: 0.�, ❑rientation: 50L1TH Name: BAGK 2ND �1� s.f.}, U: 0.32a, SHGC: Q.�, ❑rientation: SDUTH Name: RIGHT 2Na (15 s.f.}, U: 0.320, SHGC: 0.4, �rientatian: WEST Name: RIGHT 2Na (15 s.f.J, U: 0.320, SHGC: 0.4, �rientatian: WEST Skylight Nane Present Mechanical Ventilativn � Mechanical ventilation system rated for, and capable of, providing cantinuous �entilation. System shall include automatic timing controls. System type: Exhaust �nly, 6 hrsJday, 146.3 lNatts Me�hanical Equiprnent � Fuel-fired air distribution {1 }• Natural Gas • 50°Io Heating Laad a� 93 AFUE � Fuel-fired air distribution {2} • Natural Gas • 50°Io Heating Load a� 93 AFUE a Build Home 5enrices ENVIRCIN�IhENTSFOR J,�, f� 4 Energy �ode Inspectian Checklist Property ❑rganixatian 14310 MARSDALE PLACE TopBuild Home 5ervi�es, I CARMEL, IN 4fi074 Eric Bjerre Madel: LANGDON 65T Ba5 9PL R Community: ALBANY PLACE 6uilder aREES HDMES 909aREIN ALBANY PLACE 1431D MARSDALE PLACE-LANGaON � � � Air conditioner (3} • Electric • 5D°/o Coaling Load [�7a 13 SEER Air conditioner (4} • Electric • 5D°/o Coaling Load [�7a 13 SEER Inspe�tion 5tatus Results are projected Water Heating • Natural Gas • 100°Io Hot Water Load a� 0.65 Energy Fa�tar Air Leakage Cvntrol � Test Status: 6lawer-door tested House is air-sealed as to achieve 4,G89 CFM50 �5.00 AGH50] or less at final blQwer-door test. Infiltration Requirements for IECC in Climate Zone 5 2a09 IECC Infiltration limit for the design hame is 7 ACHS�. 2�12 IECC Infiltration limit for the design hame is 3 ACHS�. 2a15 IECC Infiltration limit for the design home is 3 ACHS�. 2a18 IECC Infiltration limit f�r the design hame is 3 ACHS�. Duct Leakage Duct 5ystem 1 All ducts and equipment within conditianed space Leakage to ❑utside spe�ified as: � CFM25 ! 1 DD ftZ Total Leakage spe�ified as: 4 CFM251 1D� ft2 �Post-Constru�tion} Duct 5ystem 2 All ducts and equipment within conditianed space Leakage to ❑utside spe�ified as: � CFM25 ! 10a ftZ Total Leakage spe�ified as: 4 CFM251 1D� ft2 �Post-Constru�tion} a Build Home 5enrices ENVIRCIN�IhENTSFOR J,�, f� 5 Energy �ode Inspectian Checklist Property ❑rganixatian 14310 MARSDALE PLACE TopBuild Home 5ervi�es, I CARMEL, IN 4fi074 Eric Bjerre Madel: LANGDON 65T Ba5 9PL R Community: ALBANY PLACE 6uilder aREES HDMES 909aREIN ALBANY PLACE 1431D MARSDALE PLACE-LANGaON Duct Leakage Cvde Requirements fvr IECC 20fl9 IECC: Inspe�tion 5tatus Results are projected Postconstruction Leakage Test: auct Leakage to Dutdoors �= 8 CFM251 100 sq ft CFR. Rough in Test with AHU: Tatal auct Leakage �= 6 CFM251 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage �= 4 CFM251 1 a0 sq ft CFA. 2a12 IECC and 2015 IECC Prescripti�e Path: PQstconstruction Leakage Test: Tatal au�t Leaka�e �= 4 CFM25 ! 100 sq ft CFA. Rough in Test with AHU: Total auct Leakage �= 4 CFM251 100 sq ft CFA. Raugh in Test without AHU: Total Duct Leakage �= 3 CFM25 1 100 sq ft CFA. 2015 Performance Path �Cost Campliance}: a Build Home 5enrices ENVIRCIN�IhENTSFOR J,�, f� Leakage testing is required UNLESS all ducts and air handlers are lo�ated entirely within the thermal envelope. There is no passlfail threshold for duct leakage on the performance path. Praject Nates oR� ID: 7752 ACC#: 909DREIN BUILDER NAME: DREES HOMES PR�]ECT ID: 32037 SUBDIVISI�N: ALBANY PLACE PLAN ID: 857887 PLAN NAME: 14310 MARSDALE REVISI�N DATE: 07�081ZQZQ PRQGRAM: HER5�1009��CH5:N� CREATED QN: 07�0$J2020 PLACE-LANGDQN 65T 6�5 9PL R-CC [�