HomeMy WebLinkAboutA-103A - GENERAL NOTES FOR NEW WORK & NEW WORK PLAN NOTESGENERAL NOTES FOR NEW WORK 1. ALL WORK SHALL BE DONE IN WORKMAN LIKE MANNER AND IN CONFORMANCE WITH MANUFACTURER'S INSTALLATION AND WARRANTV REQUIREMENTS. 2. ALL WORK TO BE DONE IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND FEDER4L AUTHORITIES, RULES, REGULATIONS & CODES. 3. ALL DIMENSIONS AND FIELD CONDITIONS SHALL BE VERIFIED. ANY DISCREPANCIES IN DIMENSIONS, CONDITIONS, OR DOCUMENTS SHALL BE BROUGHT IMMEDIATELY TO THE ARCHITECT'S ATTENTION. 4. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT ALL EXISTING MATERIALS, SURFACES, & EQUIPMENT TO REMAIN. 5. CONTRACTOR SHALL BE LIABLE FOR, AND TAKE ALL PRECAUTIONS NECESSARY TO PROTECT ALL EQUIPMENT AND BUILDING FROM DUST, VIBRATIONS AND WATER DAMAGE. 6. ANY UNFORESEEN OR UNCLEAR CONDITIONS SHALL BE REPORTED TO THE ARCHITECT AND OWNER PRIOR TO PROCEEDING WITH WORK. 7. REMOVE ALL DEBRIS PROPERLY FROM SITE. ALL DEMOLISHED MATERIAL, EXCEPT THAT LISTED OR MARKED BY ARCHITECT FOR RETENTION, SHALL BECOME THE PROPERTY OF THE CONTRACTOR. LOAD DEMOLISHED MATERIAL DIRECTLY ON TRUCKS OR INTO DUMPSTER, DISPOSE OF DEBRIS LEGALLY. DO NOT BURN ON SITE. DO NOT ALLOW DEBRIS TO ENTER SEWERS OR ROOF DRAINS. DO NOT LET PILED DEBRIS ENDANGER STRUCTURE, BLOCK EXITS, OR ROADWAYS. UPON DISCOVERY OF ANY HAZARDOUS MATERIALS, NOTIFY THE OWNER OF TYPE, LOCATION, AND EXTENT OF SAME. S. ALL ELECTRIC AND MECHANICAL WORK SHALL BE PROVIDED BY PERSONNEL LICENSED IN THE STATE OF INDIANA IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL CODES. 9. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, REQUIRED BY ALL AGENCIES AND AUTHORITIES HAVING JURISDICTION FOR THE WORK INCLUDED IN THIS CONTRACT. PERMIT SHALL BE CONSPICUOUSLY POSTED AT JOB SITE. 10. THE CONTRACTOR IS SPECIFICALLY RESPONSIBLE FOR ALL MEANS AND METHODS OF JOB SITE SAFETY. 11. CONTRACTOR SHALL ENSURE THAT NUMBER NOTES ARE READ IN CONJUNCTION WITH A NUMBER NOTE EXPLANATION, I.E., EACH SHEET SHOULD NOT BE READ IN ISOLATION BY THE CONTRACTOR'S WORKMEN OR HIS SUBCONTRACTORS. 12. ANY CONFLICTS IN THE DRAWINGS OR SPECIFICATIONS, OR BETWEEN DRAWINGS AND SPECIFICATIONS, SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. THE CONTRACTOR SHALL NOT PROCEED WITH WORK UNTIL WRITTEN CLARIFICATION OF CONFLICTS IS RECENED FROM THE ARCHITECT. 13. ALL EXISTING RATED WALLS, FLOORS, CEILINGS, OR SHAFTS MUST BE MAINTAINED THROUGHOUT NEW CONSTRUCTION, AND ANY PENETRATIONS OR INTERRUPTIONS MADE TO THESE RATED SYSTEMS MUST BE REPAIRED TO MAINTAIN RATING. 14. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL TRADES, FOR COORDINATION OF ALL TESTING AND INSPECTIONS NECESSARY, AND FOR DELIVERY & STORAGE OF ALL MATERIALS NECESSARY TO COMPLETE THE PROJECT. 15. THE CONTRACTOR SHALL CLEAN SITE AFTER CONSTRUCTION IN A MANNER CONSISTENT WITH THE CONDITIONS THAT EXISTED PRIOR TO CONSTRUCTION. 16. THE OWNER ASSUMES NO RESPONSIBILITY FOR THE CONDITIONS OF EXISTING MATERIALS THAT ARE TO BE REMOVED OR DEMOLISHED. NEW WORK PLAN NOTES 4: STONE 4.01 CONTRACTOR SHALL PROVIDE & INSTALL NEW STONE COUNTER TOPS & BACKSPLASH WHERE INDICATED IN FABRICATION OR OTHER DRAWINGS. FULLY ADHERE TOPS TO STABLE SUBSTRATES, FULLY ADHERE BACKSPLASH TO GYP. BRD. SUBSTRATES. TYPICAL EDGE DETAIL IS SQUARE WITH EASED EDGES. PROVIDE & INSTALL CONTINUOUS CLEAR SILICONE BEAD AT ALL STONE INTERSECTIONS, AND BETWEEN STONE AND V.W.0 OR OTHER WALL FINISH. 7: THERMAL & MOISTURE PROTECTION 7.01 TYPICAL AT ALL WALL COVERING INSTALLATIONS: PROVIDE & INSTALL CONTINUOUS JOINT SEALANT AT THE INTERSECTION OF NEW VINYL WALLCOVERING AND ALL OTHER MATERIALS / SURFACES, INCLUDING BUT NOT LIMITED TO: CEILINGS, BULKHEADS, DOOR FRAMES, ELEVATOR FRAMES, FIRE EXTINGUISHER CABIN ETS, SURFACE MOUNTED & RECESSED HEATING UNITS, MASONRY WALLS, THERMO-PLASTIC WALL COVERING. TYPICAL: USE ONE-PART NON-SAG ACRYLIC LATEX TYPE SEALANT COMPLYING WITH ASTM C834, COLOR TO MATCH WALL SURFACE, BY "TREMCO / 216-292-5000" OR EQUAL. AT TOP OF VENDING ROOM TILE BASE I WALLCOVERING USE MILDEW RESISTANT, ONE PART, SILICONE SEALANT "786 - DOW CORNING CORP / 517-496-4000" OR EQUAL. FOLLOW ALL MANUFACTURERS RECOMMENDATIONS. 8: DOORS & HARDWARE & WINDOWS & GLASS 8.07 CONTRACTOR SHALL PROVIDE & INSTALL GLASS DOOR AND / OR WINDOW FILM ON WINDOWS INDICATED ON I.D. DRAWINGS. WINDOW FILM T.B.D. 9: FINISHES & WALL FRAMING 9.01 PROVIDE & INSTALL NEW GYP. BRD. FINISH WALLS TO THE EXTENT INDICATED ON DRAWINGS (TYPICALLY "SHADED" UNLESS OTHERWISE NOTED). SEE WALL SCHEDULE FOR FRAMING TYPE, SIZE & GAGE. FRAMING SHALL INCLUDE TOP AND BOTTOM TRACKS WHICH SHALL BE BOLTED TO STRUCTURE @ CEILING & FLOOR. PROVIDE AND INSTALL CONTINUOUS DOUBLE STUDS AT DOOR JAMBS. REMOVE AREA OF CARPETMG BELOW NEW FLOOR TRACK PRIOR TO INSTALLATION OF FLOOR TRACK. TAPE AND SPACKLE WALL SMOOTH FOR RECEIPT OF NEW VINYL WALL COVERING. PROVIDE & INSTALL CONT. CORNER BEADS AT ALL EXTERIOR GYP. BRD. CORNERS, TAPE ALL JOINTS BETWEEN GYP. BRD. PANELS, SKIM COAT ALL GYP. BRD. SURFACES TP PROVIDE FLUSH, SMOOTH, CRACK FREE SUBSTRATE (SEE FINISH INDEX FOR FINISH MATERIAL). AREAS TO INCLUDE ALL GYP. BRD. WALLS, CEILINGS AND BULKHEADS. COMPLY WITH ASTM C587 USE "DIAMOND FINISH PLASTER" BY US GYPSUM CO. (312-321-4000) OR EQUAL. � CONTRACTOR TO INSTALL ALL NEW OWNER PROVIDED CARPETING AND CARPET PAD (AS DESIGNED / SELECTED BY CAUHAUS INC., PER SEAMWG DIAGRAMS BY MANUFACTURER). CONTRACTOR I INSTALLER SHALL ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY "MARRIOTT INC." FOR INSTALLATION OF CARPETING /PADDING SYSTEMS. AT CARPET INSTALLATIONS OVER AREAS OF SEVERELY DAMAGED OR UN-EVEN FLOORING CONTRACTOR SHALL PROVIDE AND INSTALL SKIM COAT OF "LATICRETE 816 - RAPID UNDERLAYMENT" OVER 100% OF DAMAGED OR UN-EVEN FLOOR SURFACE. INSTALL UNDERLAYMENT PER ALL REQUIRED SPEGFICATIONS OF "LATICRETE SYSTEMS". NEW CARPETING SHALL BE CONTINUOUS UNDER OVERHANGS & RELEA5E0 FOR CONSTRUCTION 'EWORK. CARPETING SHALL NOT RUN BANQUETTE SEATING. Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel `�y,:a���'.�`� �,�:;vaYa/„1��. ez•im.�a_�au�n�yr_���uam�arc���n�a DATE: 06�30�20 THINSET TILES TO SUBSTRATE, GROUT AND COMPACT ALL JOINTS FULL WITH SANDED EPDXY GROUT. MAXIMUN JOINT SIZE TO BE 1/8". SUBMIT GROUT COLOR SAMPLES FOR APPROVAL BY DESIGNER (MAPEI OR EQ.). CLEAN ALL HAZE AND GROUT FROM TILE SURFACE WITH APPROVED CLEANER. 9.11 CONTRACTOR SHALL SUPPLY AND INSTALL NEW WOOD WALL BASE TO MATCH EXISTING WOOD WALL BASE IN HEIGHT, THICKESS, AND PROFILE , WHERE INDICATED ON I.D. DRAWINGS. CONTRACTOR SHALL REMOVE SMALL ADJACENT WALL BASE PIECES, WHERE NECESSARY, TO PROVIDE SEAMLESS, CONTINUOUS WALL BASE PIECES. INSTALLATION TO BE WITH RECESSED FINISH NAILS. 9.14 CONTRACTOR SHALL PROVIDE AND INSTALL ALL TYPICAL & ACCENT VINYL WALLCOVERING ON ALL EXISTING & NEW GYP. BRD. WALLS (UNLESS OTHER FINISH IS SPECIFIED). PREP 100% OF WALL SUBSTRATES TO PROVIDE SMOOTH, CONTINUOUS, ADHESIVE AND DIRT FREE SURFACE TO RECEIVE NEW WALL COVERING. CONTRACTOR/INSTALLER SHALL ASSURE THAT THERE ARE NO VERTICAL SEAMS WITHIN 6" OF ANY CORNERS AND NO HORIZONTAL SEAMING. SEE FINISH SCHEDULE FOR WALL COVER TYPES, LOCATIONS, WIDTHS, REPEATS AND ROLL SIZES. CONTRACTOR/INSTALLER SHALL ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY "MARRIOTT INC." FOR INSTALLATION OF VINYL WALLCOVERING SYSTEMS. 9: PAINTING AND STAINING FINISHES 9.50 CLEAN AND TOUCH UP STAIN ALL WOOD FINISH DOORS, EXISITNG WOOD MILLWORK, WOOD PIERS, WOOD BASE AND WOOD TRIM SURFACES TO PROVIDE NICK 8 SCRATCH FREE, CONSISTENT STAIN COLOR AND TONE SURFACES, TREATMENT NOT TO EXCEED 50 % OF ALL SURFACES. TREAT ALL SURFACES WITH LIGHT MINERAL SPIRIT SOLVENT TO REMOVE DIRT, DUST AND GREASE. ALLOW DOORS TO DRY, AND LIGHTLY SAND WITH "FINAL STRIPPING PADS", CLEAN RESIDUE WITH "TACK CLOTH". TOUCH UP DOOR SURFACES AND EDGES WITH MATCHING STAIN COLOR. FILL NICKS AND DENTS WITH MATCHING WOOD PUTTY, SMOOTHED AND SANDED TO BE FLUSH. APPLY A COAT OF CLEAR SATIN MINWAX "POLYACRYLIC PROTECTIVE FINISH" USE A FOAM APPLICATOR TYPE BRUSH, ALLOW 8 HOURS TO DRY. DOOR LEVER HARDWARE TO REMAIN IN PLACE DURING REFINISHING, PROTECT DOOR HARDWARE FROM RECEIVING STAIN OR FINISH. 9.52 APPLY NEW THREE COAT PAINTING SYSTEM (PRIMER & TWO FINISH COATS) TO ALL GYP. BRD. / PLASTER FINISH CEILINGS (SEE FINISH SCHEDULE FOR COLORS AND SHEEN). CONTRACTOR / INSTALLER SHALL ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY "MARRIOTT INC." FOR APPLICATION OF PAINTING SYSTEMS. 9.58 APPLY NEW THREE COAT PAINTING SYSTEM (PRIMER & TWO FINISH COATS) TO ALL ALREADY PAINTED GYP. BRD. / PLASTER FINISH WALLS, SOFFITS, R BULKHEADS (SEE FINISH SCHEDULE FOR COLORS AND SHEEN). CONTRACTOR / INSTALLER SHALL ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY "MARRIOTT INC." FOR APPLICATION OF PAINTING SYSTEMS. 9.60 APPLY NEW THREE COAT PAINTING SYSTEM (PRIMER & TWO FINISH COATS) TO ALL EXISTING LOW WALLS AT RESTAURANT BANQUETTES (SEE FINISH SCHEDULE FOR COLORS AND SHEEN). CONTRACTOR / INSTALLER SHALL ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY "MARRIOTT INC." FOR APPLICATION OF PAINTING SYSTEMS. 10: SPECIALITIES 10.05 @ ALL TRANSITIONS BETWEEN NEW OR EXISTING CARPETING AND NEW FLOOR TILE SYSTEMS (PORCELAIN OR STONE), PROVIDE AND INSTALL CONTINUOUS FLOOR TRIMS "SCHIENE AE-125 IN MILLED SATIN ALUMINUM " BY "SCHLUTER" 1-800-472-4588 / 1-800-477-9783 FAX. MITER CORNERS & ANGLES. USE "SCHIENE - RADIUS - RAE 125" IN MILLED SATIN ALUMINUM AT ALL CURVES. INSTALL IN LONGEST LENGTHS WITH CLOSELY FITTED AND ALIGNED BUTT JOINTS. INSTALL W I HORIZONTAL LEG KEYED INTO TILE MORTAR BED. TOP EDGE SHALL BE SET FLUSH WITH FINISHED FLOOR TILE. CLEAN AND REMOVE ANY MORTAR STAINS. PROVIDE TRIMS FOR FULL LENGTHS OF TILE FLOORING ICARPET JUNCTIONS. INSTALL PER ALL RECOMMENDATIONS / REQUIREMENTS OF "SCHLUTER SYSTEMS". 11: EQUIPMENT 11.03 FLAT SCREEN TELEVISION (EXISTING / RELOCATED): CONTRACTOR SHALL REINSTALL FLAT SCREEN TELEVISIONS & TELEVISION MOUNTING DEVICES, WHERE INDICATED ON DRAWINGS, IN LOCATIONS WHERE THEY HAVE BEEN TEMPORARILY REMOVED OR RELOCATED IN ORDER TO PROVIDE SPACE TO CONSTRUCT NEW WORK, IN ACCORDANCE WITH NEW CONSTRUCTION DRAWINGS. CONTRACTOR SHALL PROVIDE ALL NECESSARY IN WALL BLOCKING TO SUPPORT TV & TV MOUNTING BRACKET IF EXISTING CONDITIONS DO NOT PROVIDE ADEQUATE SUPPORT. CONTRACTOR SHALL PROVIDE ALL NECESSARY ELECTRICAL CONNECTIONS REQUIRED FOR OPERATION / INSTALLATION OF EQUIPMENT. CONTRACTER SHALL COORDINATE RE-INSTALLATION WITH NEW & EXISTING WALL AND/OR CEILING FINISHES. CONTRACTOR SHALL COORDINATE WITH PROPERTY & HELP TO INSTALL AND CONNECT CABLE WIRING SYSTEMS TO ALL TELEVISIONS. 11.05 CONTRACTOR SHALL ASSIST PROPERTY IN RE-LOCATING EXISTING (EQUIPMENT) TO STORAGE LOCATION DESIGNATED BY PROPERTY DURING CONSTRUCTION, AND SHALL ASSIST PROPERTY IN MOVING (EQUIPMENT) TO FINAL LOCAL UPON COMPLETION OF RENOVATION WORK. 12: FURNISHINGS & FF&E 12.01 CONTRACTOR SHALL ASSIST PROPERTY IN INSTALLATION OF ALL OWNER PROVIDED FF&E ITEMS. 12.03 fF��P! CONTRACTOR SHALL REINSTALL ALL REFINISHED FF&E BUILT-IN BANQUETTE SEATING. CONTRACTOR SHALL COORDINATE AND INSTALL ALL SPECIFIED ANCHORING /CONNECTION DEVICES. (RESTAURANT BUFFET): CONTRACTOR SHALL PROVIDE & INSTALL NEW CURTAINS. PROTECT & REUSE ALL ASSOCIATED MOUNTING HARDWARE, IF APPLICABLE. 12.05 CONTRACTOR SHALL INSTALL OWNER-PROVIDED ROLLER SHADE WITH BLACKOUT AND SHEER SHADES WITH SIDE TRACKS, AND ALL ASSOCIATED HARDWARE, BY OWNER. CONTRACTOR TO CONFIRM ADEQUATE SUPPORT BLOCKING BEFORE INSTALLATION OF WINDOW SHADES. INSTALL SHADES PER MANUFACTURERSINSTALLATIONINSTRUCTIONS. f b'Abl xN:C1�l[N_1�I,lUPil:11�[H 15.01 (NOT IN USE) 15.02 CONTRACTOR SHALL COVER 6 PROTECT EXISTING FLOOR DRAINS FROM DAMAGE, DUST AND DEBRIS FOR THE DURATION OF THE RENOVATION /CONSTRUCTION WORK. 16: ELECTRICAL I LIGHTWG 16.01 PROVIDE & MSTALL NEW OUTLETS AND COVER PLATES AT ALL POWER , GFI, DATA, SWITCHING & DIMMER OUTLETS, AND PHONE JACKS. COLOR TO BE WHITE. 16.02 PROVIDE AND INSTALL NEW EDGE LIT EXIT SIGNS AS REQUIRED (SEE ELECTRICAL DRAWINGS). 16.03 (NOT IN USE) 16.04 (NOT IN USE) 16.06 CONTRACTOR SHALL INSTALL ALL "OWNER PROVIDED" DECORATIVE LIGHTING IN ACCORDANCE WITH LIGHT FIXTURE SCHEDULE AND / OR FF&E SPECIFICATION MANUAL (SEE ELECTRICAL DRAWINGS AS WELL). CONTRACTOR SHALL COORDINATE INSTALLATION WITH NEW CEILINGS, DUCTWORK, GRILLES, A/V EQUIPMENT, AND ALL OTHER CEILING ELEMENTS. CONTRACTOR SHALL VERIFY COMPATIBILITY OF ALL FIXTURES WITH PROPOSED CEILING TYPE (GYP. BRD., A.T.C., ETC.), AND SHALL PROVIDE ALL NECESSARY STRUCTURAL SUPPORTS / BLOCKWG TO SUPPORT DECORATIVE FIXTURES (WEIGHTS TO BE PROVIDED BY FABRICATORS). Q L N N - C ai� ��� Q _ � o D o��a 3 Y y���.�_ coNsu�rnrvrs _/ T � U 0 t �� O = U" � WU Q' w � L O m L R WLm� W W'o� Z A-`ui 3 -m � u d� Z � E � W in i� '" � V �� J(n ~p�M OzQ7 UQ�Z Zp�� �Z�w (�_�� wO�U KZ� i.0 U Z � Q J cf) w N � Q � Z w � ARCXITECT'S SEAL J Sq;q'o,� s;cRFo :Nso< ': a aE�EnsEOFoa� ❑ PRELIMINARY ONLY ❑sioowc � vERMirs ❑ corvsraucnory onTe�.oanszazo PROJECT NO'. 5052 DRAWN. LW oEscrvEn�w cHEcrc:reo sHeeT,ine. GENERFLNOTES FOR NEW WORKB NEW WORK PLAN NOTES sHEEr No: A.103A