HomeMy WebLinkAboutA-103A - GENERAL NOTES FOR NEW WORK & NEW WORK PLAN NOTESGENERAL NOTES FOR NEW WORK
1. ALL WORK SHALL BE DONE IN WORKMAN LIKE MANNER AND IN
CONFORMANCE WITH MANUFACTURER'S INSTALLATION AND
WARRANTV REQUIREMENTS.
2. ALL WORK TO BE DONE IN ACCORDANCE WITH ALL APPLICABLE
LOCAL, STATE, AND FEDER4L AUTHORITIES, RULES, REGULATIONS &
CODES.
3. ALL DIMENSIONS AND FIELD CONDITIONS SHALL BE VERIFIED. ANY
DISCREPANCIES IN DIMENSIONS, CONDITIONS, OR DOCUMENTS
SHALL BE BROUGHT IMMEDIATELY TO THE ARCHITECT'S ATTENTION.
4. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO
PROTECT ALL EXISTING MATERIALS, SURFACES, & EQUIPMENT TO
REMAIN.
5. CONTRACTOR SHALL BE LIABLE FOR, AND TAKE ALL PRECAUTIONS
NECESSARY TO PROTECT ALL EQUIPMENT AND BUILDING FROM
DUST, VIBRATIONS AND WATER DAMAGE.
6. ANY UNFORESEEN OR UNCLEAR CONDITIONS SHALL BE REPORTED
TO THE ARCHITECT AND OWNER PRIOR TO PROCEEDING WITH WORK.
7. REMOVE ALL DEBRIS PROPERLY FROM SITE. ALL DEMOLISHED
MATERIAL, EXCEPT THAT LISTED OR MARKED BY ARCHITECT FOR
RETENTION, SHALL BECOME THE PROPERTY OF THE CONTRACTOR.
LOAD DEMOLISHED MATERIAL DIRECTLY ON TRUCKS OR INTO
DUMPSTER, DISPOSE OF DEBRIS LEGALLY. DO NOT BURN ON SITE.
DO NOT ALLOW DEBRIS TO ENTER SEWERS OR ROOF DRAINS. DO
NOT LET PILED DEBRIS ENDANGER STRUCTURE, BLOCK EXITS, OR
ROADWAYS. UPON DISCOVERY OF ANY HAZARDOUS MATERIALS,
NOTIFY THE OWNER OF TYPE, LOCATION, AND EXTENT OF SAME.
S. ALL ELECTRIC AND MECHANICAL WORK SHALL BE PROVIDED BY
PERSONNEL LICENSED IN THE STATE OF INDIANA IN ACCORDANCE
WITH ALL LOCAL, STATE, AND FEDERAL CODES.
9. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS,
REQUIRED BY ALL AGENCIES AND AUTHORITIES HAVING
JURISDICTION FOR THE WORK INCLUDED IN THIS CONTRACT. PERMIT
SHALL BE CONSPICUOUSLY POSTED AT JOB SITE.
10. THE CONTRACTOR IS SPECIFICALLY RESPONSIBLE FOR ALL MEANS
AND METHODS OF JOB SITE SAFETY.
11. CONTRACTOR SHALL ENSURE THAT NUMBER NOTES ARE READ IN
CONJUNCTION WITH A NUMBER NOTE EXPLANATION, I.E., EACH
SHEET SHOULD NOT BE READ IN ISOLATION BY THE CONTRACTOR'S
WORKMEN OR HIS SUBCONTRACTORS.
12. ANY CONFLICTS IN THE DRAWINGS OR SPECIFICATIONS, OR BETWEEN
DRAWINGS AND SPECIFICATIONS, SHALL BE BROUGHT TO THE
IMMEDIATE ATTENTION OF THE ARCHITECT. THE CONTRACTOR
SHALL NOT PROCEED WITH WORK UNTIL WRITTEN CLARIFICATION OF
CONFLICTS IS RECENED FROM THE ARCHITECT.
13. ALL EXISTING RATED WALLS, FLOORS, CEILINGS, OR SHAFTS MUST BE
MAINTAINED THROUGHOUT NEW CONSTRUCTION, AND ANY
PENETRATIONS OR INTERRUPTIONS MADE TO THESE RATED
SYSTEMS MUST BE REPAIRED TO MAINTAIN RATING.
14. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL
TRADES, FOR COORDINATION OF ALL TESTING AND INSPECTIONS
NECESSARY, AND FOR DELIVERY & STORAGE OF ALL MATERIALS
NECESSARY TO COMPLETE THE PROJECT.
15. THE CONTRACTOR SHALL CLEAN SITE AFTER CONSTRUCTION IN A
MANNER CONSISTENT WITH THE CONDITIONS THAT EXISTED PRIOR
TO CONSTRUCTION.
16. THE OWNER ASSUMES NO RESPONSIBILITY FOR THE CONDITIONS OF
EXISTING MATERIALS THAT ARE TO BE REMOVED OR DEMOLISHED.
NEW WORK PLAN NOTES
4: STONE
4.01 CONTRACTOR SHALL PROVIDE & INSTALL NEW STONE
COUNTER TOPS & BACKSPLASH WHERE INDICATED IN
FABRICATION OR OTHER DRAWINGS. FULLY ADHERE TOPS TO
STABLE SUBSTRATES, FULLY ADHERE BACKSPLASH TO GYP.
BRD. SUBSTRATES. TYPICAL EDGE DETAIL IS SQUARE WITH
EASED EDGES. PROVIDE & INSTALL CONTINUOUS CLEAR
SILICONE BEAD AT ALL STONE INTERSECTIONS, AND BETWEEN
STONE AND V.W.0 OR OTHER WALL FINISH.
7: THERMAL & MOISTURE PROTECTION
7.01 TYPICAL AT ALL WALL COVERING INSTALLATIONS: PROVIDE &
INSTALL CONTINUOUS JOINT SEALANT AT THE INTERSECTION
OF NEW VINYL WALLCOVERING AND ALL OTHER MATERIALS /
SURFACES, INCLUDING BUT NOT LIMITED TO: CEILINGS,
BULKHEADS, DOOR FRAMES, ELEVATOR FRAMES, FIRE
EXTINGUISHER CABIN ETS, SURFACE MOUNTED & RECESSED
HEATING UNITS, MASONRY WALLS, THERMO-PLASTIC WALL
COVERING. TYPICAL: USE ONE-PART NON-SAG ACRYLIC LATEX
TYPE SEALANT COMPLYING WITH ASTM C834, COLOR TO
MATCH WALL SURFACE, BY "TREMCO / 216-292-5000" OR
EQUAL. AT TOP OF VENDING ROOM TILE BASE I
WALLCOVERING USE MILDEW RESISTANT, ONE PART,
SILICONE SEALANT "786 - DOW CORNING CORP / 517-496-4000"
OR EQUAL. FOLLOW ALL MANUFACTURERS
RECOMMENDATIONS.
8: DOORS & HARDWARE & WINDOWS & GLASS
8.07 CONTRACTOR SHALL PROVIDE & INSTALL GLASS DOOR AND /
OR WINDOW FILM ON WINDOWS INDICATED ON I.D. DRAWINGS.
WINDOW FILM T.B.D.
9: FINISHES & WALL FRAMING
9.01 PROVIDE & INSTALL NEW GYP. BRD. FINISH WALLS TO THE
EXTENT INDICATED ON DRAWINGS (TYPICALLY "SHADED"
UNLESS OTHERWISE NOTED). SEE WALL SCHEDULE FOR
FRAMING TYPE, SIZE & GAGE. FRAMING SHALL INCLUDE TOP
AND BOTTOM TRACKS WHICH SHALL BE BOLTED TO
STRUCTURE @ CEILING & FLOOR. PROVIDE AND INSTALL
CONTINUOUS DOUBLE STUDS AT DOOR JAMBS. REMOVE
AREA OF CARPETMG BELOW NEW FLOOR TRACK PRIOR TO
INSTALLATION OF FLOOR TRACK. TAPE AND SPACKLE WALL
SMOOTH FOR RECEIPT OF NEW VINYL WALL COVERING.
PROVIDE & INSTALL CONT. CORNER BEADS AT ALL EXTERIOR
GYP. BRD. CORNERS, TAPE ALL JOINTS BETWEEN GYP. BRD.
PANELS, SKIM COAT ALL GYP. BRD. SURFACES TP PROVIDE
FLUSH, SMOOTH, CRACK FREE SUBSTRATE (SEE FINISH INDEX
FOR FINISH MATERIAL). AREAS TO INCLUDE ALL GYP. BRD.
WALLS, CEILINGS AND BULKHEADS. COMPLY WITH ASTM C587
USE "DIAMOND FINISH PLASTER" BY US GYPSUM CO.
(312-321-4000) OR EQUAL.
�
CONTRACTOR TO INSTALL ALL NEW OWNER PROVIDED
CARPETING AND CARPET PAD (AS DESIGNED / SELECTED BY
CAUHAUS INC., PER SEAMWG DIAGRAMS BY MANUFACTURER).
CONTRACTOR I INSTALLER SHALL ADHERE TO ALL
SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY
"MARRIOTT INC." FOR INSTALLATION OF CARPETING /PADDING
SYSTEMS. AT CARPET INSTALLATIONS OVER AREAS OF
SEVERELY DAMAGED OR UN-EVEN FLOORING CONTRACTOR
SHALL PROVIDE AND INSTALL SKIM COAT OF "LATICRETE 816 -
RAPID UNDERLAYMENT" OVER 100% OF DAMAGED OR
UN-EVEN FLOOR SURFACE. INSTALL UNDERLAYMENT PER ALL
REQUIRED SPEGFICATIONS OF "LATICRETE SYSTEMS". NEW
CARPETING SHALL BE CONTINUOUS UNDER OVERHANGS &
RELEA5E0 FOR CONSTRUCTION 'EWORK. CARPETING SHALL NOT RUN
BANQUETTE SEATING.
Suhjec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
`�y,:a���'.�`� �,�:;vaYa/„1��.
ez•im.�a_�au�n�yr_���uam�arc���n�a
DATE: 06�30�20
THINSET TILES TO SUBSTRATE, GROUT AND COMPACT ALL
JOINTS FULL WITH SANDED EPDXY GROUT. MAXIMUN JOINT
SIZE TO BE 1/8". SUBMIT GROUT COLOR SAMPLES FOR
APPROVAL BY DESIGNER (MAPEI OR EQ.). CLEAN ALL HAZE
AND GROUT FROM TILE SURFACE WITH APPROVED CLEANER.
9.11 CONTRACTOR SHALL SUPPLY AND INSTALL NEW WOOD WALL
BASE TO MATCH EXISTING WOOD WALL BASE IN HEIGHT,
THICKESS, AND PROFILE , WHERE INDICATED ON I.D.
DRAWINGS. CONTRACTOR SHALL REMOVE SMALL ADJACENT
WALL BASE PIECES, WHERE NECESSARY, TO PROVIDE
SEAMLESS, CONTINUOUS WALL BASE PIECES. INSTALLATION
TO BE WITH RECESSED FINISH NAILS.
9.14 CONTRACTOR SHALL PROVIDE AND INSTALL ALL TYPICAL &
ACCENT VINYL WALLCOVERING ON ALL EXISTING & NEW GYP.
BRD. WALLS (UNLESS OTHER FINISH IS SPECIFIED). PREP 100%
OF WALL SUBSTRATES TO PROVIDE SMOOTH, CONTINUOUS,
ADHESIVE AND DIRT FREE SURFACE TO RECEIVE NEW WALL
COVERING. CONTRACTOR/INSTALLER SHALL ASSURE THAT
THERE ARE NO VERTICAL SEAMS WITHIN 6" OF ANY CORNERS
AND NO HORIZONTAL SEAMING. SEE FINISH SCHEDULE FOR
WALL COVER TYPES, LOCATIONS, WIDTHS, REPEATS AND
ROLL SIZES. CONTRACTOR/INSTALLER SHALL ADHERE TO ALL
SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY
"MARRIOTT INC." FOR INSTALLATION OF VINYL WALLCOVERING
SYSTEMS.
9: PAINTING AND STAINING FINISHES
9.50 CLEAN AND TOUCH UP STAIN ALL WOOD FINISH DOORS,
EXISITNG WOOD MILLWORK, WOOD PIERS, WOOD BASE AND
WOOD TRIM SURFACES TO PROVIDE NICK 8 SCRATCH FREE,
CONSISTENT STAIN COLOR AND TONE SURFACES,
TREATMENT NOT TO EXCEED 50 % OF ALL SURFACES. TREAT
ALL SURFACES WITH LIGHT MINERAL SPIRIT SOLVENT TO
REMOVE DIRT, DUST AND GREASE. ALLOW DOORS TO DRY,
AND LIGHTLY SAND WITH "FINAL STRIPPING PADS", CLEAN
RESIDUE WITH "TACK CLOTH". TOUCH UP DOOR SURFACES
AND EDGES WITH MATCHING STAIN COLOR. FILL NICKS AND
DENTS WITH MATCHING WOOD PUTTY, SMOOTHED AND
SANDED TO BE FLUSH. APPLY A COAT OF CLEAR SATIN
MINWAX "POLYACRYLIC PROTECTIVE FINISH" USE A FOAM
APPLICATOR TYPE BRUSH, ALLOW 8 HOURS TO DRY. DOOR
LEVER HARDWARE TO REMAIN IN PLACE DURING REFINISHING,
PROTECT DOOR HARDWARE FROM RECEIVING STAIN OR
FINISH.
9.52 APPLY NEW THREE COAT PAINTING SYSTEM (PRIMER & TWO
FINISH COATS) TO ALL GYP. BRD. / PLASTER FINISH CEILINGS
(SEE FINISH SCHEDULE FOR COLORS AND SHEEN).
CONTRACTOR / INSTALLER SHALL ADHERE TO ALL
SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY
"MARRIOTT INC." FOR APPLICATION OF PAINTING SYSTEMS.
9.58 APPLY NEW THREE COAT PAINTING SYSTEM (PRIMER & TWO
FINISH COATS) TO ALL ALREADY PAINTED GYP. BRD. / PLASTER
FINISH WALLS, SOFFITS, R BULKHEADS (SEE FINISH SCHEDULE
FOR COLORS AND SHEEN). CONTRACTOR / INSTALLER SHALL
ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS
PROVIDED BY "MARRIOTT INC." FOR APPLICATION OF PAINTING
SYSTEMS.
9.60 APPLY NEW THREE COAT PAINTING SYSTEM (PRIMER & TWO
FINISH COATS) TO ALL EXISTING LOW WALLS AT RESTAURANT
BANQUETTES (SEE FINISH SCHEDULE FOR COLORS AND
SHEEN). CONTRACTOR / INSTALLER SHALL ADHERE TO ALL
SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY
"MARRIOTT INC." FOR APPLICATION OF PAINTING SYSTEMS.
10: SPECIALITIES
10.05 @ ALL TRANSITIONS BETWEEN NEW OR EXISTING CARPETING
AND NEW FLOOR TILE SYSTEMS (PORCELAIN OR STONE),
PROVIDE AND INSTALL CONTINUOUS FLOOR TRIMS
"SCHIENE AE-125 IN MILLED SATIN ALUMINUM " BY "SCHLUTER"
1-800-472-4588 /
1-800-477-9783 FAX. MITER CORNERS & ANGLES. USE
"SCHIENE - RADIUS - RAE 125" IN MILLED SATIN ALUMINUM AT
ALL CURVES. INSTALL IN LONGEST LENGTHS WITH CLOSELY
FITTED AND ALIGNED BUTT JOINTS. INSTALL W I HORIZONTAL
LEG KEYED INTO TILE MORTAR BED. TOP EDGE SHALL BE SET
FLUSH WITH FINISHED FLOOR TILE. CLEAN AND REMOVE ANY
MORTAR STAINS. PROVIDE TRIMS FOR FULL LENGTHS OF TILE
FLOORING ICARPET JUNCTIONS. INSTALL PER ALL
RECOMMENDATIONS / REQUIREMENTS OF
"SCHLUTER SYSTEMS".
11: EQUIPMENT
11.03 FLAT SCREEN TELEVISION (EXISTING / RELOCATED):
CONTRACTOR SHALL REINSTALL FLAT SCREEN TELEVISIONS &
TELEVISION MOUNTING DEVICES, WHERE INDICATED ON
DRAWINGS, IN LOCATIONS WHERE THEY HAVE BEEN
TEMPORARILY REMOVED OR RELOCATED IN ORDER TO
PROVIDE SPACE TO CONSTRUCT NEW WORK, IN ACCORDANCE
WITH NEW CONSTRUCTION DRAWINGS. CONTRACTOR SHALL
PROVIDE ALL NECESSARY IN WALL BLOCKING TO SUPPORT TV
& TV MOUNTING BRACKET IF EXISTING CONDITIONS DO NOT
PROVIDE ADEQUATE SUPPORT. CONTRACTOR SHALL PROVIDE
ALL NECESSARY ELECTRICAL CONNECTIONS REQUIRED FOR
OPERATION / INSTALLATION OF EQUIPMENT. CONTRACTER
SHALL COORDINATE RE-INSTALLATION WITH NEW & EXISTING
WALL AND/OR CEILING FINISHES. CONTRACTOR SHALL
COORDINATE WITH PROPERTY & HELP TO INSTALL AND
CONNECT CABLE WIRING SYSTEMS TO ALL TELEVISIONS.
11.05 CONTRACTOR SHALL ASSIST PROPERTY IN RE-LOCATING
EXISTING (EQUIPMENT) TO STORAGE LOCATION DESIGNATED
BY PROPERTY DURING CONSTRUCTION, AND SHALL ASSIST
PROPERTY IN MOVING (EQUIPMENT) TO FINAL LOCAL UPON
COMPLETION OF RENOVATION WORK.
12: FURNISHINGS & FF&E
12.01 CONTRACTOR SHALL ASSIST PROPERTY IN INSTALLATION OF
ALL OWNER PROVIDED FF&E ITEMS.
12.03
fF��P!
CONTRACTOR SHALL REINSTALL ALL REFINISHED FF&E
BUILT-IN BANQUETTE SEATING. CONTRACTOR SHALL
COORDINATE AND INSTALL ALL SPECIFIED ANCHORING
/CONNECTION DEVICES.
(RESTAURANT BUFFET): CONTRACTOR SHALL PROVIDE &
INSTALL NEW CURTAINS. PROTECT & REUSE ALL ASSOCIATED
MOUNTING HARDWARE, IF APPLICABLE.
12.05 CONTRACTOR SHALL INSTALL OWNER-PROVIDED ROLLER
SHADE WITH BLACKOUT AND SHEER SHADES WITH SIDE
TRACKS, AND ALL ASSOCIATED HARDWARE, BY OWNER.
CONTRACTOR TO CONFIRM ADEQUATE SUPPORT BLOCKING
BEFORE INSTALLATION OF WINDOW SHADES. INSTALL
SHADES PER MANUFACTURERSINSTALLATIONINSTRUCTIONS.
f b'Abl xN:C1�l[N_1�I,lUPil:11�[H
15.01 (NOT IN USE)
15.02 CONTRACTOR SHALL COVER 6 PROTECT EXISTING FLOOR
DRAINS FROM DAMAGE, DUST AND DEBRIS FOR THE DURATION
OF THE RENOVATION /CONSTRUCTION WORK.
16: ELECTRICAL I LIGHTWG
16.01 PROVIDE & MSTALL NEW OUTLETS AND COVER PLATES AT ALL
POWER , GFI, DATA, SWITCHING & DIMMER OUTLETS, AND
PHONE JACKS. COLOR TO BE WHITE.
16.02 PROVIDE AND INSTALL NEW EDGE LIT EXIT SIGNS AS
REQUIRED (SEE ELECTRICAL DRAWINGS).
16.03 (NOT IN USE)
16.04 (NOT IN USE)
16.06 CONTRACTOR SHALL INSTALL ALL "OWNER PROVIDED"
DECORATIVE LIGHTING IN ACCORDANCE WITH LIGHT FIXTURE
SCHEDULE AND / OR FF&E SPECIFICATION MANUAL (SEE
ELECTRICAL DRAWINGS AS WELL). CONTRACTOR SHALL
COORDINATE INSTALLATION WITH NEW CEILINGS, DUCTWORK,
GRILLES, A/V EQUIPMENT, AND ALL OTHER CEILING ELEMENTS.
CONTRACTOR SHALL VERIFY COMPATIBILITY OF ALL FIXTURES
WITH PROPOSED CEILING TYPE (GYP. BRD., A.T.C., ETC.), AND
SHALL PROVIDE ALL NECESSARY STRUCTURAL SUPPORTS /
BLOCKWG TO SUPPORT DECORATIVE FIXTURES (WEIGHTS TO
BE PROVIDED BY FABRICATORS).
Q
L
N
N -
C
ai� ���
Q _ � o
D o��a
3
Y
y���.�_
coNsu�rnrvrs
_/
T
�
U
0 t
��
O =
U"
�
WU
Q' w
� L
O m
L
R
WLm�
W W'o�
Z A-`ui
3 -m
� u d�
Z � E �
W in i� '"
� V
��
J(n
~p�M
OzQ7
UQ�Z
Zp��
�Z�w
(�_��
wO�U
KZ�
i.0
U
Z
� Q J
cf) w
N �
Q �
Z
w
�
ARCXITECT'S SEAL
J Sq;q'o,�
s;cRFo :Nso<
': a
aE�EnsEOFoa�
❑ PRELIMINARY ONLY
❑sioowc
� vERMirs
❑ corvsraucnory
onTe�.oanszazo
PROJECT NO'. 5052
DRAWN. LW
oEscrvEn�w
cHEcrc:reo
sHeeT,ine.
GENERFLNOTES FOR
NEW WORKB
NEW WORK PLAN NOTES
sHEEr No:
A.103A